Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
| Split |
Close |
| Expand all |
| Collapse all |
--- old/usr/src/cmd/fm/dicts/SUN4U.po
+++ new/usr/src/cmd/fm/dicts/SUN4U.po
1 1 #
2 2 # Copyright 2009 Sun Microsystems, Inc. All rights reserved.
3 3 # Use is subject to license terms.
4 4 #
5 5 # CDDL HEADER START
6 6 #
7 7 # The contents of this file are subject to the terms of the
8 8 # Common Development and Distribution License (the "License").
9 9 # You may not use this file except in compliance with the License.
10 10 #
11 11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 12 # or http://www.opensolaris.org/os/licensing.
13 13 # See the License for the specific language governing permissions
14 14 # and limitations under the License.
15 15 #
16 16 # When distributing Covered Code, include this CDDL HEADER in each
17 17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 18 # If applicable, add the following below this CDDL HEADER, with the
19 19 # fields enclosed by brackets "[]" replaced with your own identifying
20 20 # information: Portions Copyright [yyyy] [name of copyright owner]
21 21 #
22 22 # CDDL HEADER END
23 23 #
24 24 #
25 25 # DO NOT EDIT -- this file is generated by the Event Registry.
26 26 #
27 27 #
28 28 # code: SUN4U-8000-1A
29 29 # keys: fault.memory.page
30 30 #
31 31 msgid "SUN4U-8000-1A.type"
32 32 msgstr "Fault"
33 33 msgid "SUN4U-8000-1A.severity"
34 34 msgstr "Minor"
35 35 msgid "SUN4U-8000-1A.description"
36 36 msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information."
37 37 msgid "SUN4U-8000-1A.response"
38 38 msgstr "An attempt will be made to remove this memory page from service."
39 39 msgid "SUN4U-8000-1A.impact"
40 40 msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
41 41 msgid "SUN4U-8000-1A.action"
42 42 msgstr "No repair action is recommended at this time."
43 43 #
44 44 # code: SUN4U-8000-2S
45 45 # keys: fault.memory.dimm
46 46 #
47 47 msgid "SUN4U-8000-2S.type"
48 48 msgstr "Fault"
49 49 msgid "SUN4U-8000-2S.severity"
50 50 msgstr "Major"
51 51 msgid "SUN4U-8000-2S.description"
52 52 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information."
53 53 msgid "SUN4U-8000-2S.response"
54 54 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
55 55 msgid "SUN4U-8000-2S.impact"
56 56 msgstr "Total system memory capacity has been reduced."
57 57 msgid "SUN4U-8000-2S.action"
58 58 msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
59 59 #
60 60 # code: SUN4U-8000-35
61 61 # keys: fault.memory.bank
62 62 #
63 63 msgid "SUN4U-8000-35.type"
64 64 msgstr "Fault"
65 65 msgid "SUN4U-8000-35.severity"
66 66 msgstr "Critical"
67 67 msgid "SUN4U-8000-35.description"
68 68 msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information."
69 69 msgid "SUN4U-8000-35.response"
70 70 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
71 71 msgid "SUN4U-8000-35.impact"
72 72 msgstr "Total system memory capacity will be reduced as pages are retired."
73 73 msgid "SUN4U-8000-35.action"
74 74 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
75 75 #
76 76 # code: SUN4U-8000-4Y
77 77 # keys: fault.cpu.ultraSPARC-III.dcache
78 78 #
79 79 msgid "SUN4U-8000-4Y.type"
80 80 msgstr "Fault"
81 81 msgid "SUN4U-8000-4Y.severity"
82 82 msgstr "Major"
83 83 msgid "SUN4U-8000-4Y.description"
84 84 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
85 85 msgid "SUN4U-8000-4Y.response"
86 86 msgstr "The fault manager will attempt to remove the affected CPU from service."
87 87 msgid "SUN4U-8000-4Y.impact"
88 88 msgstr "System performance may be affected."
89 89 msgid "SUN4U-8000-4Y.action"
90 90 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
91 91 #
92 92 # code: SUN4U-8000-53
93 93 # keys: fault.cpu.ultraSPARC-III.icache
94 94 #
95 95 msgid "SUN4U-8000-53.type"
96 96 msgstr "Fault"
97 97 msgid "SUN4U-8000-53.severity"
98 98 msgstr "Major"
99 99 msgid "SUN4U-8000-53.description"
100 100 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
101 101 msgid "SUN4U-8000-53.response"
102 102 msgstr "The fault manager will attempt to remove the affected CPU from service."
103 103 msgid "SUN4U-8000-53.impact"
104 104 msgstr "System performance may be affected."
105 105 msgid "SUN4U-8000-53.action"
106 106 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
107 107 #
108 108 # code: SUN4U-8000-6H
109 109 # keys: fault.cpu.ultraSPARC-III.l2cachedata
110 110 #
111 111 msgid "SUN4U-8000-6H.type"
112 112 msgstr "Fault"
113 113 msgid "SUN4U-8000-6H.severity"
114 114 msgstr "Major"
115 115 msgid "SUN4U-8000-6H.description"
116 116 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
117 117 msgid "SUN4U-8000-6H.response"
118 118 msgstr "The fault manager will attempt to remove the affected CPU from service."
119 119 msgid "SUN4U-8000-6H.impact"
120 120 msgstr "System performance may be affected."
121 121 msgid "SUN4U-8000-6H.action"
122 122 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
123 123 #
124 124 # code: SUN4U-8000-7D
125 125 # keys: fault.cpu.ultraSPARC-III.l2cachetag
126 126 #
127 127 msgid "SUN4U-8000-7D.type"
128 128 msgstr "Fault"
129 129 msgid "SUN4U-8000-7D.severity"
130 130 msgstr "Major"
131 131 msgid "SUN4U-8000-7D.description"
132 132 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
133 133 msgid "SUN4U-8000-7D.response"
134 134 msgstr "The fault manager will attempt to remove the affected CPU from service."
135 135 msgid "SUN4U-8000-7D.impact"
136 136 msgstr "System performance may be affected."
137 137 msgid "SUN4U-8000-7D.action"
138 138 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
139 139 #
140 140 # code: SUN4U-8000-84
141 141 # keys: fault.cpu.ultraSPARC-IIIi.dcache
142 142 #
143 143 msgid "SUN4U-8000-84.type"
144 144 msgstr "Fault"
145 145 msgid "SUN4U-8000-84.severity"
146 146 msgstr "Major"
147 147 msgid "SUN4U-8000-84.description"
148 148 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
149 149 msgid "SUN4U-8000-84.response"
150 150 msgstr "The fault manager will attempt to remove the affected CPU from service."
151 151 msgid "SUN4U-8000-84.impact"
152 152 msgstr "System performance system may be affected."
153 153 msgid "SUN4U-8000-84.action"
154 154 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
155 155 #
156 156 # code: SUN4U-8000-9R
157 157 # keys: fault.cpu.ultraSPARC-IIIi.icache
158 158 #
159 159 msgid "SUN4U-8000-9R.type"
160 160 msgstr "Fault"
161 161 msgid "SUN4U-8000-9R.severity"
162 162 msgstr "Major"
163 163 msgid "SUN4U-8000-9R.description"
164 164 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
165 165 msgid "SUN4U-8000-9R.response"
166 166 msgstr "The fault manager will attempt to remove the affected CPU from service."
167 167 msgid "SUN4U-8000-9R.impact"
168 168 msgstr "System performance may be affected."
169 169 msgid "SUN4U-8000-9R.action"
170 170 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
171 171 #
172 172 # code: SUN4U-8000-AC
173 173 # keys: fault.cpu.ultraSPARC-IIIi.l2cachedata
174 174 #
175 175 msgid "SUN4U-8000-AC.type"
176 176 msgstr "Fault"
177 177 msgid "SUN4U-8000-AC.severity"
178 178 msgstr "Major"
179 179 msgid "SUN4U-8000-AC.description"
180 180 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
181 181 msgid "SUN4U-8000-AC.response"
182 182 msgstr "The fault manager will attempt to remove the affected CPU from service."
183 183 msgid "SUN4U-8000-AC.impact"
184 184 msgstr "System performance may be affected."
185 185 msgid "SUN4U-8000-AC.action"
186 186 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
187 187 #
188 188 # code: SUN4U-8000-CQ
189 189 # keys: fault.cpu.ultraSPARC-IIIi.l2cachetag
190 190 #
191 191 msgid "SUN4U-8000-CQ.type"
192 192 msgstr "Fault"
193 193 msgid "SUN4U-8000-CQ.severity"
194 194 msgstr "Major"
195 195 msgid "SUN4U-8000-CQ.description"
196 196 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
197 197 msgid "SUN4U-8000-CQ.response"
198 198 msgstr "The fault manager will attempt to remove the affected CPU from service."
199 199 msgid "SUN4U-8000-CQ.impact"
200 200 msgstr "System performance may be affected."
201 201 msgid "SUN4U-8000-CQ.action"
202 202 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
203 203 #
204 204 # code: SUN4U-8000-DE
205 205 # keys: fault.cpu.ultraSPARC-IIIplus.dcache
206 206 #
207 207 msgid "SUN4U-8000-DE.type"
208 208 msgstr "Fault"
209 209 msgid "SUN4U-8000-DE.severity"
210 210 msgstr "Major"
211 211 msgid "SUN4U-8000-DE.description"
212 212 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
213 213 msgid "SUN4U-8000-DE.response"
214 214 msgstr "The fault manager will attempt to remove the affected CPU from service."
215 215 msgid "SUN4U-8000-DE.impact"
216 216 msgstr "System performance may be affected."
217 217 msgid "SUN4U-8000-DE.action"
218 218 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
219 219 #
220 220 # code: SUN4U-8000-EJ
221 221 # keys: fault.cpu.ultraSPARC-IIIplus.icache
222 222 #
223 223 msgid "SUN4U-8000-EJ.type"
224 224 msgstr "Fault"
225 225 msgid "SUN4U-8000-EJ.severity"
226 226 msgstr "Major"
227 227 msgid "SUN4U-8000-EJ.description"
228 228 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
229 229 msgid "SUN4U-8000-EJ.response"
230 230 msgstr "The fault manager will attempt to remove the affected CPU from service."
231 231 msgid "SUN4U-8000-EJ.impact"
232 232 msgstr "System performance may be affected."
233 233 msgid "SUN4U-8000-EJ.action"
234 234 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
235 235 #
236 236 # code: SUN4U-8000-F2
237 237 # keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata
238 238 #
239 239 msgid "SUN4U-8000-F2.type"
240 240 msgstr "Fault"
241 241 msgid "SUN4U-8000-F2.severity"
242 242 msgstr "Major"
243 243 msgid "SUN4U-8000-F2.description"
244 244 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
245 245 msgid "SUN4U-8000-F2.response"
246 246 msgstr "The fault manager will attempt to remove the affected CPU from service."
247 247 msgid "SUN4U-8000-F2.impact"
248 248 msgstr "System performance may be affected."
249 249 msgid "SUN4U-8000-F2.action"
250 250 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
251 251 #
252 252 # code: SUN4U-8000-GX
253 253 # keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag
254 254 #
255 255 msgid "SUN4U-8000-GX.type"
256 256 msgstr "Fault"
257 257 msgid "SUN4U-8000-GX.severity"
258 258 msgstr "Major"
259 259 msgid "SUN4U-8000-GX.description"
260 260 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
261 261 msgid "SUN4U-8000-GX.response"
262 262 msgstr "An attempt will be made to remove the affected CPU from service."
263 263 msgid "SUN4U-8000-GX.impact"
264 264 msgstr "System performance may be affected."
265 265 msgid "SUN4U-8000-GX.action"
266 266 msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u <EVENT_ID> to identify the CPU."
267 267 #
268 268 # code: SUN4U-8000-H5
269 269 # keys: fault.cpu.ultraSPARC-IV.dcache
270 270 #
271 271 msgid "SUN4U-8000-H5.type"
272 272 msgstr "Fault"
273 273 msgid "SUN4U-8000-H5.severity"
274 274 msgstr "Major"
275 275 msgid "SUN4U-8000-H5.description"
276 276 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
277 277 msgid "SUN4U-8000-H5.response"
278 278 msgstr "The fault manager will attempt to remove the affected CPU from service."
279 279 msgid "SUN4U-8000-H5.impact"
280 280 msgstr "System performance may be affected."
281 281 msgid "SUN4U-8000-H5.action"
282 282 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
283 283 #
284 284 # code: SUN4U-8000-JS
285 285 # keys: fault.cpu.ultraSPARC-IV.icache
286 286 #
287 287 msgid "SUN4U-8000-JS.type"
288 288 msgstr "Fault"
289 289 msgid "SUN4U-8000-JS.severity"
290 290 msgstr "Major"
291 291 msgid "SUN4U-8000-JS.description"
292 292 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
293 293 msgid "SUN4U-8000-JS.response"
294 294 msgstr "The fault manager will attempt to remove the affected CPU from service."
295 295 msgid "SUN4U-8000-JS.impact"
296 296 msgstr "System performance may be affected."
297 297 msgid "SUN4U-8000-JS.action"
298 298 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
299 299 #
300 300 # code: SUN4U-8000-KA
301 301 # keys: fault.cpu.ultraSPARC-IV.l2cachedata
302 302 #
303 303 msgid "SUN4U-8000-KA.type"
304 304 msgstr "Fault"
305 305 msgid "SUN4U-8000-KA.severity"
306 306 msgstr "Major"
307 307 msgid "SUN4U-8000-KA.description"
308 308 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
309 309 msgid "SUN4U-8000-KA.response"
310 310 msgstr "The fault manager will attempt to remove the affected CPU from service."
311 311 msgid "SUN4U-8000-KA.impact"
312 312 msgstr "System performance may be affected."
313 313 msgid "SUN4U-8000-KA.action"
314 314 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
315 315 #
316 316 # code: SUN4U-8000-LP
317 317 # keys: fault.cpu.ultraSPARC-IV.l2cachetag
318 318 #
319 319 msgid "SUN4U-8000-LP.type"
320 320 msgstr "Fault"
321 321 msgid "SUN4U-8000-LP.severity"
322 322 msgstr "Major"
323 323 msgid "SUN4U-8000-LP.description"
324 324 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
325 325 msgid "SUN4U-8000-LP.response"
326 326 msgstr "The fault manager will attempt to remove the affected CPU from service."
327 327 msgid "SUN4U-8000-LP.impact"
328 328 msgstr "System performance may be affected."
329 329 msgid "SUN4U-8000-LP.action"
330 330 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
331 331 #
332 332 # code: SUN4U-8000-MD
333 333 # keys: fault.cpu.ultraSPARC-III.fpu
334 334 #
335 335 msgid "SUN4U-8000-MD.type"
336 336 msgstr "Fault"
337 337 msgid "SUN4U-8000-MD.severity"
338 338 msgstr "Major"
339 339 msgid "SUN4U-8000-MD.description"
340 340 msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information."
341 341 msgid "SUN4U-8000-MD.response"
342 342 msgstr "The fault manager will attempt to remove the affected CPU from service."
343 343 msgid "SUN4U-8000-MD.impact"
344 344 msgstr "System performance may be affected."
345 345 msgid "SUN4U-8000-MD.action"
346 346 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
347 347 #
348 348 # code: SUN4U-8000-NH
349 349 # keys: fault.cpu.ultraSPARC-IIIi.fpu
350 350 #
351 351 msgid "SUN4U-8000-NH.type"
352 352 msgstr "Fault"
353 353 msgid "SUN4U-8000-NH.severity"
354 354 msgstr "Major"
355 355 msgid "SUN4U-8000-NH.description"
356 356 msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information."
357 357 msgid "SUN4U-8000-NH.response"
358 358 msgstr "The fault manager will attempt to remove the affected CPU from service."
359 359 msgid "SUN4U-8000-NH.impact"
360 360 msgstr "System performance may be affected."
361 361 msgid "SUN4U-8000-NH.action"
362 362 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
363 363 #
364 364 # code: SUN4U-8000-P3
365 365 # keys: fault.cpu.ultraSPARC-IIIplus.fpu
366 366 #
367 367 msgid "SUN4U-8000-P3.type"
368 368 msgstr "Fault"
369 369 msgid "SUN4U-8000-P3.severity"
370 370 msgstr "Major"
371 371 msgid "SUN4U-8000-P3.description"
372 372 msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information."
373 373 msgid "SUN4U-8000-P3.response"
374 374 msgstr "The fault manager will attempt to remove the affected CPU from service."
375 375 msgid "SUN4U-8000-P3.impact"
376 376 msgstr "System performance may be affected."
377 377 msgid "SUN4U-8000-P3.action"
378 378 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
379 379 #
380 380 # code: SUN4U-8000-QY
381 381 # keys: fault.cpu.ultraSPARC-IV.fpu
382 382 #
383 383 msgid "SUN4U-8000-QY.type"
384 384 msgstr "Fault"
385 385 msgid "SUN4U-8000-QY.severity"
386 386 msgstr "Major"
387 387 msgid "SUN4U-8000-QY.description"
388 388 msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information."
389 389 msgid "SUN4U-8000-QY.response"
390 390 msgstr "The fault manager will attempt to remove the affected CPU from service."
391 391 msgid "SUN4U-8000-QY.impact"
392 392 msgstr "System performance may be affected."
393 393 msgid "SUN4U-8000-QY.action"
394 394 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
395 395 #
396 396 # code: SUN4U-8000-RQ
397 397 # keys: fault.cpu.ultraSPARC-IVplus.fpu
398 398 #
399 399 msgid "SUN4U-8000-RQ.type"
400 400 msgstr "Fault"
401 401 msgid "SUN4U-8000-RQ.severity"
402 402 msgstr "Major"
403 403 msgid "SUN4U-8000-RQ.description"
404 404 msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information."
405 405 msgid "SUN4U-8000-RQ.response"
406 406 msgstr "The fault manager will attempt to remove the affected CPU from service."
407 407 msgid "SUN4U-8000-RQ.impact"
408 408 msgstr "System performance may be affected."
409 409 msgid "SUN4U-8000-RQ.action"
410 410 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
411 411 #
412 412 # code: SUN4U-8000-SC
413 413 # keys: fault.cpu.ultraSPARC-IVplus.dcache
414 414 #
415 415 msgid "SUN4U-8000-SC.type"
416 416 msgstr "Fault"
417 417 msgid "SUN4U-8000-SC.severity"
418 418 msgstr "Major"
419 419 msgid "SUN4U-8000-SC.description"
420 420 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
421 421 msgid "SUN4U-8000-SC.response"
422 422 msgstr "The fault manager will attempt to remove the affected CPU from service."
423 423 msgid "SUN4U-8000-SC.impact"
424 424 msgstr "System performance may be affected."
425 425 msgid "SUN4U-8000-SC.action"
426 426 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
427 427 #
428 428 # code: SUN4U-8000-TR
429 429 # keys: fault.cpu.ultraSPARC-IVplus.icache
430 430 #
431 431 msgid "SUN4U-8000-TR.type"
432 432 msgstr "Fault"
433 433 msgid "SUN4U-8000-TR.severity"
434 434 msgstr "Major"
435 435 msgid "SUN4U-8000-TR.description"
436 436 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
437 437 msgid "SUN4U-8000-TR.response"
438 438 msgstr "The fault manager will attempt to remove the affected CPU from service."
439 439 msgid "SUN4U-8000-TR.impact"
440 440 msgstr "System performance may be affected."
441 441 msgid "SUN4U-8000-TR.action"
442 442 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
443 443 #
444 444 # code: SUN4U-8000-U4
445 445 # keys: fault.cpu.ultraSPARC-IVplus.pcache
446 446 #
447 447 msgid "SUN4U-8000-U4.type"
448 448 msgstr "Fault"
449 449 msgid "SUN4U-8000-U4.severity"
450 450 msgstr "Major"
451 451 msgid "SUN4U-8000-U4.description"
452 452 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
453 453 msgid "SUN4U-8000-U4.response"
454 454 msgstr "The fault manager will attempt to remove the affected CPU from service."
455 455 msgid "SUN4U-8000-U4.impact"
456 456 msgstr "System performance may be affected."
457 457 msgid "SUN4U-8000-U4.action"
458 458 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
459 459 #
460 460 # code: SUN4U-8000-VX
461 461 # keys: fault.cpu.ultraSPARC-IVplus.dtlb
462 462 #
463 463 msgid "SUN4U-8000-VX.type"
464 464 msgstr "Fault"
465 465 msgid "SUN4U-8000-VX.severity"
466 466 msgstr "Major"
467 467 msgid "SUN4U-8000-VX.description"
468 468 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
469 469 msgid "SUN4U-8000-VX.response"
470 470 msgstr "The fault manager will attempt to remove the affected CPU from service."
471 471 msgid "SUN4U-8000-VX.impact"
472 472 msgstr "System performance may be affected."
473 473 msgid "SUN4U-8000-VX.action"
474 474 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
475 475 #
476 476 # code: SUN4U-8000-W2
477 477 # keys: fault.cpu.ultraSPARC-IVplus.itlb
478 478 #
479 479 msgid "SUN4U-8000-W2.type"
480 480 msgstr "Fault"
481 481 msgid "SUN4U-8000-W2.severity"
482 482 msgstr "Major"
483 483 msgid "SUN4U-8000-W2.description"
484 484 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
485 485 msgid "SUN4U-8000-W2.response"
486 486 msgstr "The fault manager will attempt to remove the affected CPU from service."
487 487 msgid "SUN4U-8000-W2.impact"
488 488 msgstr "System performance may be affected."
489 489 msgid "SUN4U-8000-W2.action"
490 490 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
491 491 #
492 492 # code: SUN4U-8000-XJ
493 493 # keys: fault.cpu.ultraSPARC-IVplus.l2cachedata
494 494 #
495 495 msgid "SUN4U-8000-XJ.type"
496 496 msgstr "Fault"
497 497 msgid "SUN4U-8000-XJ.severity"
498 498 msgstr "Major"
499 499 msgid "SUN4U-8000-XJ.description"
500 500 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
501 501 msgid "SUN4U-8000-XJ.response"
502 502 msgstr "The fault manager will attempt to remove the affected CPU from service."
503 503 msgid "SUN4U-8000-XJ.impact"
504 504 msgstr "System performance may be affected."
505 505 msgid "SUN4U-8000-XJ.action"
506 506 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
507 507 #
508 508 # code: SUN4U-8000-YE
509 509 # keys: fault.cpu.ultraSPARC-IVplus.l2cachetag
510 510 #
511 511 msgid "SUN4U-8000-YE.type"
512 512 msgstr "Fault"
513 513 msgid "SUN4U-8000-YE.severity"
514 514 msgstr "Major"
515 515 msgid "SUN4U-8000-YE.description"
516 516 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
517 517 msgid "SUN4U-8000-YE.response"
518 518 msgstr "The fault manager will attempt to remove the affected CPU from service."
519 519 msgid "SUN4U-8000-YE.impact"
520 520 msgstr "System performance may be affected."
521 521 msgid "SUN4U-8000-YE.action"
522 522 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
523 523 #
524 524 # code: SUN4U-8001-0J
525 525 # keys: fault.cpu.ultraSPARC-IVplus.l3cachedata
526 526 #
527 527 msgid "SUN4U-8001-0J.type"
528 528 msgstr "Fault"
529 529 msgid "SUN4U-8001-0J.severity"
530 530 msgstr "Major"
531 531 msgid "SUN4U-8001-0J.description"
532 532 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
533 533 msgid "SUN4U-8001-0J.response"
534 534 msgstr "The fault manager will attempt to remove the affected CPU from service."
535 535 msgid "SUN4U-8001-0J.impact"
536 536 msgstr "System performance may be affected."
537 537 msgid "SUN4U-8001-0J.action"
538 538 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
539 539 #
540 540 # code: SUN4U-8001-1E
541 541 # keys: fault.cpu.ultraSPARC-IVplus.l3cachetag
542 542 #
543 543 msgid "SUN4U-8001-1E.type"
544 544 msgstr "Fault"
545 545 msgid "SUN4U-8001-1E.severity"
546 546 msgstr "Major"
547 547 msgid "SUN4U-8001-1E.description"
548 548 msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information."
549 549 msgid "SUN4U-8001-1E.response"
550 550 msgstr "The fault manager will attempt to remove the affected CPU from service."
551 551 msgid "SUN4U-8001-1E.impact"
552 552 msgstr "System performance may be affected."
553 553 msgid "SUN4U-8001-1E.action"
|
↓ open down ↓ |
553 lines elided |
↑ open up ↑ |
554 554 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
555 555 #
556 556 # code: SUN4U-8001-2X
557 557 # keys: defect.ultraSPARC-II.memory.nodiag
558 558 #
559 559 msgid "SUN4U-8001-2X.type"
560 560 msgstr "Defect"
561 561 msgid "SUN4U-8001-2X.severity"
562 562 msgstr "Minor"
563 563 msgid "SUN4U-8001-2X.description"
564 -msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information."
564 +msgstr "The illumos Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information."
565 565 msgid "SUN4U-8001-2X.response"
566 -msgstr "The error information has been saved for examination by Sun."
566 +msgstr "The error information has been saved for examination by your illumos distribution team."
567 567 msgid "SUN4U-8001-2X.impact"
568 568 msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
569 569 msgid "SUN4U-8001-2X.action"
570 570 msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors."
571 571 #
572 572 # code: SUN4U-8001-32
573 573 # keys: fault.memory.datapath
574 574 #
575 575 msgid "SUN4U-8001-32.type"
576 576 msgstr "Fault"
577 577 msgid "SUN4U-8001-32.severity"
578 578 msgstr "Major"
579 579 msgid "SUN4U-8001-32.description"
580 580 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information."
581 581 msgid "SUN4U-8001-32.response"
582 -msgstr "Error reports from the affected components will be logged for examination by Sun."
582 +msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team."
583 583 msgid "SUN4U-8001-32.impact"
584 584 msgstr "System performance and stability may be affected."
585 585 msgid "SUN4U-8001-32.action"
586 586 msgstr "Contact your service provider for further diagnosis."
587 587 #
588 588 # code: SUN4U-8001-4R
589 589 # keys: fault.io.datapath
590 590 #
591 591 msgid "SUN4U-8001-4R.type"
592 592 msgstr "Fault"
593 593 msgid "SUN4U-8001-4R.severity"
594 594 msgstr "Critical"
595 595 msgid "SUN4U-8001-4R.description"
596 596 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
597 597 msgid "SUN4U-8001-4R.response"
598 598 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
599 599 msgid "SUN4U-8001-4R.impact"
600 600 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
601 601 msgid "SUN4U-8001-4R.action"
602 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
602 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
603 603 #
604 604 # code: SUN4U-8001-54
605 605 # keys: defect.io.pci.driver fault.io.datapath
606 606 #
607 607 msgid "SUN4U-8001-54.type"
608 608 msgstr "Fault"
609 609 msgid "SUN4U-8001-54.severity"
610 610 msgstr "Critical"
611 611 msgid "SUN4U-8001-54.description"
612 612 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
613 613 msgid "SUN4U-8001-54.response"
614 614 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
615 615 msgid "SUN4U-8001-54.impact"
616 616 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
617 617 msgid "SUN4U-8001-54.action"
618 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
618 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
619 619 #
620 620 # code: SUN4U-8001-6Q
621 621 # keys: fault.io.datapath fault.io.pci.bus
622 622 #
623 623 msgid "SUN4U-8001-6Q.type"
624 624 msgstr "Fault"
625 625 msgid "SUN4U-8001-6Q.severity"
626 626 msgstr "Critical"
627 627 msgid "SUN4U-8001-6Q.description"
628 628 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
629 629 msgid "SUN4U-8001-6Q.response"
630 630 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
631 631 msgid "SUN4U-8001-6Q.impact"
632 632 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
633 633 msgid "SUN4U-8001-6Q.action"
634 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
634 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
635 635 #
636 636 # code: SUN4U-8001-7C
637 637 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus
638 638 #
639 639 msgid "SUN4U-8001-7C.type"
640 640 msgstr "Fault"
641 641 msgid "SUN4U-8001-7C.severity"
642 642 msgstr "Critical"
643 643 msgid "SUN4U-8001-7C.description"
644 644 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
645 645 msgid "SUN4U-8001-7C.response"
646 646 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
647 647 msgid "SUN4U-8001-7C.impact"
648 648 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
649 649 msgid "SUN4U-8001-7C.action"
650 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
650 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
651 651 #
652 652 # code: SUN4U-8001-83
653 653 # keys: fault.io.datapath fault.io.pci.device
654 654 #
655 655 msgid "SUN4U-8001-83.type"
656 656 msgstr "Fault"
657 657 msgid "SUN4U-8001-83.severity"
658 658 msgstr "Critical"
659 659 msgid "SUN4U-8001-83.description"
660 660 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
661 661 msgid "SUN4U-8001-83.response"
662 662 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
663 663 msgid "SUN4U-8001-83.impact"
664 664 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
665 665 msgid "SUN4U-8001-83.action"
666 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
666 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
667 667 #
668 668 # code: SUN4U-8001-9Y
669 669 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device
670 670 #
671 671 msgid "SUN4U-8001-9Y.type"
672 672 msgstr "Fault"
673 673 msgid "SUN4U-8001-9Y.severity"
674 674 msgstr "Critical"
675 675 msgid "SUN4U-8001-9Y.description"
676 676 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
677 677 msgid "SUN4U-8001-9Y.response"
678 678 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
679 679 msgid "SUN4U-8001-9Y.impact"
680 680 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
681 681 msgid "SUN4U-8001-9Y.action"
682 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
682 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
683 683 #
684 684 # code: SUN4U-8001-AD
685 685 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device
686 686 #
687 687 msgid "SUN4U-8001-AD.type"
688 688 msgstr "Fault"
689 689 msgid "SUN4U-8001-AD.severity"
690 690 msgstr "Critical"
691 691 msgid "SUN4U-8001-AD.description"
692 692 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
693 693 msgid "SUN4U-8001-AD.response"
694 694 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
695 695 msgid "SUN4U-8001-AD.impact"
696 696 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
697 697 msgid "SUN4U-8001-AD.action"
698 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
698 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
699 699 #
700 700 # code: SUN4U-8001-CH
701 701 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device
702 702 #
703 703 msgid "SUN4U-8001-CH.type"
704 704 msgstr "Fault"
705 705 msgid "SUN4U-8001-CH.severity"
706 706 msgstr "Critical"
707 707 msgid "SUN4U-8001-CH.description"
708 708 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
709 709 msgid "SUN4U-8001-CH.response"
710 710 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
711 711 msgid "SUN4U-8001-CH.impact"
712 712 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
713 713 msgid "SUN4U-8001-CH.action"
714 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
714 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
715 715 #
716 716 # code: SUN4U-8001-DA
717 717 # keys: fault.io.hbus
718 718 #
719 719 msgid "SUN4U-8001-DA.type"
720 720 msgstr "Fault"
721 721 msgid "SUN4U-8001-DA.severity"
722 722 msgstr "Critical"
723 723 msgid "SUN4U-8001-DA.description"
724 724 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
725 725 msgid "SUN4U-8001-DA.response"
726 726 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
727 727 msgid "SUN4U-8001-DA.impact"
728 728 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
729 729 msgid "SUN4U-8001-DA.action"
730 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
730 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
731 731 #
732 732 # code: SUN4U-8001-EP
733 733 # keys: defect.io.pci.driver fault.io.hbus
734 734 #
735 735 msgid "SUN4U-8001-EP.type"
736 736 msgstr "Fault"
737 737 msgid "SUN4U-8001-EP.severity"
738 738 msgstr "Critical"
739 739 msgid "SUN4U-8001-EP.description"
740 740 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
741 741 msgid "SUN4U-8001-EP.response"
742 742 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
743 743 msgid "SUN4U-8001-EP.impact"
744 744 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
745 745 msgid "SUN4U-8001-EP.action"
746 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
746 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
747 747 #
748 748 # code: SUN4U-8001-F5
749 749 # keys: fault.io.hbus fault.io.pci.bus
750 750 #
751 751 msgid "SUN4U-8001-F5.type"
752 752 msgstr "Fault"
753 753 msgid "SUN4U-8001-F5.severity"
754 754 msgstr "Critical"
755 755 msgid "SUN4U-8001-F5.description"
756 756 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
757 757 msgid "SUN4U-8001-F5.response"
758 758 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
759 759 msgid "SUN4U-8001-F5.impact"
760 760 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
761 761 msgid "SUN4U-8001-F5.action"
762 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
762 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
763 763 #
764 764 # code: SUN4U-8001-GS
765 765 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus
766 766 #
767 767 msgid "SUN4U-8001-GS.type"
768 768 msgstr "Fault"
769 769 msgid "SUN4U-8001-GS.severity"
770 770 msgstr "Critical"
771 771 msgid "SUN4U-8001-GS.description"
772 772 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
773 773 msgid "SUN4U-8001-GS.response"
774 774 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
775 775 msgid "SUN4U-8001-GS.impact"
776 776 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
777 777 msgid "SUN4U-8001-GS.action"
778 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
778 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
779 779 #
780 780 # code: SUN4U-8001-H2
781 781 # keys: fault.io.hbus fault.io.pci.device
782 782 #
783 783 msgid "SUN4U-8001-H2.type"
784 784 msgstr "Fault"
785 785 msgid "SUN4U-8001-H2.severity"
786 786 msgstr "Critical"
787 787 msgid "SUN4U-8001-H2.description"
788 788 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
789 789 msgid "SUN4U-8001-H2.response"
790 790 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
791 791 msgid "SUN4U-8001-H2.impact"
792 792 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
793 793 msgid "SUN4U-8001-H2.action"
794 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
794 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
795 795 #
796 796 # code: SUN4U-8001-JX
797 797 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device
798 798 #
799 799 msgid "SUN4U-8001-JX.type"
800 800 msgstr "Fault"
801 801 msgid "SUN4U-8001-JX.severity"
802 802 msgstr "Critical"
803 803 msgid "SUN4U-8001-JX.description"
804 804 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
805 805 msgid "SUN4U-8001-JX.response"
806 806 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
807 807 msgid "SUN4U-8001-JX.impact"
808 808 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
809 809 msgid "SUN4U-8001-JX.action"
810 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
810 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
811 811 #
812 812 # code: SUN4U-8001-KE
813 813 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device
814 814 #
815 815 msgid "SUN4U-8001-KE.type"
816 816 msgstr "Fault"
817 817 msgid "SUN4U-8001-KE.severity"
818 818 msgstr "Critical"
819 819 msgid "SUN4U-8001-KE.description"
820 820 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
821 821 msgid "SUN4U-8001-KE.response"
822 822 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
823 823 msgid "SUN4U-8001-KE.impact"
824 824 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
825 825 msgid "SUN4U-8001-KE.action"
826 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
826 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
827 827 #
828 828 # code: SUN4U-8001-LJ
829 829 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device
830 830 #
831 831 msgid "SUN4U-8001-LJ.type"
832 832 msgstr "Fault"
833 833 msgid "SUN4U-8001-LJ.severity"
834 834 msgstr "Critical"
835 835 msgid "SUN4U-8001-LJ.description"
836 836 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
837 837 msgid "SUN4U-8001-LJ.response"
838 838 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
839 839 msgid "SUN4U-8001-LJ.impact"
840 840 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
841 841 msgid "SUN4U-8001-LJ.action"
842 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
842 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
843 843 #
844 844 # code: SUN4U-8001-MC
845 845 # keys: fault.io.datapath fault.io.hbus
846 846 #
847 847 msgid "SUN4U-8001-MC.type"
848 848 msgstr "Fault"
849 849 msgid "SUN4U-8001-MC.severity"
850 850 msgstr "Critical"
851 851 msgid "SUN4U-8001-MC.description"
852 852 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
853 853 msgid "SUN4U-8001-MC.response"
854 854 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
855 855 msgid "SUN4U-8001-MC.impact"
856 856 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
857 857 msgid "SUN4U-8001-MC.action"
858 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
858 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
859 859 #
860 860 # code: SUN4U-8001-NQ
861 861 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus
862 862 #
863 863 msgid "SUN4U-8001-NQ.type"
864 864 msgstr "Fault"
865 865 msgid "SUN4U-8001-NQ.severity"
866 866 msgstr "Critical"
867 867 msgid "SUN4U-8001-NQ.description"
868 868 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
869 869 msgid "SUN4U-8001-NQ.response"
870 870 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
871 871 msgid "SUN4U-8001-NQ.impact"
872 872 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
873 873 msgid "SUN4U-8001-NQ.action"
874 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
874 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
875 875 #
876 876 # code: SUN4U-8001-P4
877 877 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus
878 878 #
879 879 msgid "SUN4U-8001-P4.type"
880 880 msgstr "Fault"
881 881 msgid "SUN4U-8001-P4.severity"
882 882 msgstr "Critical"
883 883 msgid "SUN4U-8001-P4.description"
884 884 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
885 885 msgid "SUN4U-8001-P4.response"
886 886 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
887 887 msgid "SUN4U-8001-P4.impact"
888 888 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
889 889 msgid "SUN4U-8001-P4.action"
890 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
890 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
891 891 #
892 892 # code: SUN4U-8001-QR
893 893 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus
894 894 #
895 895 msgid "SUN4U-8001-QR.type"
896 896 msgstr "Fault"
897 897 msgid "SUN4U-8001-QR.severity"
898 898 msgstr "Critical"
899 899 msgid "SUN4U-8001-QR.description"
900 900 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
901 901 msgid "SUN4U-8001-QR.response"
902 902 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
903 903 msgid "SUN4U-8001-QR.impact"
904 904 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
905 905 msgid "SUN4U-8001-QR.action"
906 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
906 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
907 907 #
908 908 # code: SUN4U-8001-RH
909 909 # keys: fault.io.datapath fault.io.hbus fault.io.pci.device
910 910 #
911 911 msgid "SUN4U-8001-RH.type"
912 912 msgstr "Fault"
913 913 msgid "SUN4U-8001-RH.severity"
914 914 msgstr "Critical"
915 915 msgid "SUN4U-8001-RH.description"
916 916 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
917 917 msgid "SUN4U-8001-RH.response"
918 918 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
919 919 msgid "SUN4U-8001-RH.impact"
920 920 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
921 921 msgid "SUN4U-8001-RH.action"
922 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
922 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
923 923 #
924 924 # code: SUN4U-8001-SD
925 925 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device
926 926 #
927 927 msgid "SUN4U-8001-SD.type"
928 928 msgstr "Fault"
929 929 msgid "SUN4U-8001-SD.severity"
930 930 msgstr "Critical"
931 931 msgid "SUN4U-8001-SD.description"
932 932 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
933 933 msgid "SUN4U-8001-SD.response"
934 934 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
935 935 msgid "SUN4U-8001-SD.impact"
936 936 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
937 937 msgid "SUN4U-8001-SD.action"
938 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
938 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
939 939 #
940 940 # code: SUN4U-8001-TY
941 941 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
942 942 #
943 943 msgid "SUN4U-8001-TY.type"
944 944 msgstr "Fault"
945 945 msgid "SUN4U-8001-TY.severity"
946 946 msgstr "Critical"
947 947 msgid "SUN4U-8001-TY.description"
948 948 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
949 949 msgid "SUN4U-8001-TY.response"
950 950 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
951 951 msgid "SUN4U-8001-TY.impact"
952 952 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
953 953 msgid "SUN4U-8001-TY.action"
954 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
954 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
955 955 #
956 956 # code: SUN4U-8001-U3
957 957 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
958 958 #
959 959 msgid "SUN4U-8001-U3.type"
960 960 msgstr "Fault"
961 961 msgid "SUN4U-8001-U3.severity"
962 962 msgstr "Critical"
963 963 msgid "SUN4U-8001-U3.description"
964 964 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
965 965 msgid "SUN4U-8001-U3.response"
966 966 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
967 967 msgid "SUN4U-8001-U3.impact"
968 968 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
969 969 msgid "SUN4U-8001-U3.action"
970 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
970 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
971 971 #
972 972 # code: SUN4U-8001-VS
973 973 # keys: fault.io.schizo
974 974 #
975 975 msgid "SUN4U-8001-VS.type"
976 976 msgstr "Fault"
977 977 msgid "SUN4U-8001-VS.severity"
978 978 msgstr "Critical"
979 979 msgid "SUN4U-8001-VS.description"
980 980 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
981 981 msgid "SUN4U-8001-VS.response"
982 982 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
983 983 msgid "SUN4U-8001-VS.impact"
984 984 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
985 985 msgid "SUN4U-8001-VS.action"
986 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
986 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
987 987 #
988 988 # code: SUN4U-8001-W5
989 989 # keys: defect.io.pci.driver fault.io.schizo
990 990 #
991 991 msgid "SUN4U-8001-W5.type"
992 992 msgstr "Fault"
993 993 msgid "SUN4U-8001-W5.severity"
994 994 msgstr "Critical"
995 995 msgid "SUN4U-8001-W5.description"
996 996 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
997 997 msgid "SUN4U-8001-W5.response"
998 998 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
999 999 msgid "SUN4U-8001-W5.impact"
1000 1000 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1001 1001 msgid "SUN4U-8001-W5.action"
1002 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1002 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1003 1003 #
1004 1004 # code: SUN4U-8001-XP
1005 1005 # keys: fault.io.pci.bus fault.io.schizo
1006 1006 #
1007 1007 msgid "SUN4U-8001-XP.type"
1008 1008 msgstr "Fault"
1009 1009 msgid "SUN4U-8001-XP.severity"
1010 1010 msgstr "Critical"
1011 1011 msgid "SUN4U-8001-XP.description"
1012 1012 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1013 1013 msgid "SUN4U-8001-XP.response"
1014 1014 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1015 1015 msgid "SUN4U-8001-XP.impact"
1016 1016 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1017 1017 msgid "SUN4U-8001-XP.action"
1018 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1018 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1019 1019 #
1020 1020 # code: SUN4U-8001-YA
1021 1021 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo
1022 1022 #
1023 1023 msgid "SUN4U-8001-YA.type"
1024 1024 msgstr "Fault"
1025 1025 msgid "SUN4U-8001-YA.severity"
1026 1026 msgstr "Critical"
1027 1027 msgid "SUN4U-8001-YA.description"
1028 1028 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1029 1029 msgid "SUN4U-8001-YA.response"
1030 1030 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1031 1031 msgid "SUN4U-8001-YA.impact"
1032 1032 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1033 1033 msgid "SUN4U-8001-YA.action"
1034 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1034 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1035 1035 #
1036 1036 # code: SUN4U-8002-0R
1037 1037 # keys: fault.io.pci.device fault.io.schizo
1038 1038 #
1039 1039 msgid "SUN4U-8002-0R.type"
1040 1040 msgstr "Fault"
1041 1041 msgid "SUN4U-8002-0R.severity"
1042 1042 msgstr "Critical"
1043 1043 msgid "SUN4U-8002-0R.description"
1044 1044 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1045 1045 msgid "SUN4U-8002-0R.response"
1046 1046 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1047 1047 msgid "SUN4U-8002-0R.impact"
1048 1048 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1049 1049 msgid "SUN4U-8002-0R.action"
1050 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1050 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1051 1051 #
1052 1052 # code: SUN4U-8002-14
1053 1053 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo
1054 1054 #
1055 1055 msgid "SUN4U-8002-14.type"
1056 1056 msgstr "Fault"
1057 1057 msgid "SUN4U-8002-14.severity"
1058 1058 msgstr "Critical"
1059 1059 msgid "SUN4U-8002-14.description"
1060 1060 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1061 1061 msgid "SUN4U-8002-14.response"
1062 1062 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1063 1063 msgid "SUN4U-8002-14.impact"
1064 1064 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1065 1065 msgid "SUN4U-8002-14.action"
1066 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1066 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1067 1067 #
1068 1068 # code: SUN4U-8002-2Q
1069 1069 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo
1070 1070 #
1071 1071 msgid "SUN4U-8002-2Q.type"
1072 1072 msgstr "Fault"
1073 1073 msgid "SUN4U-8002-2Q.severity"
1074 1074 msgstr "Critical"
1075 1075 msgid "SUN4U-8002-2Q.description"
1076 1076 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1077 1077 msgid "SUN4U-8002-2Q.response"
1078 1078 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1079 1079 msgid "SUN4U-8002-2Q.impact"
1080 1080 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1081 1081 msgid "SUN4U-8002-2Q.action"
1082 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1082 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1083 1083 #
1084 1084 # code: SUN4U-8002-3C
1085 1085 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo
1086 1086 #
1087 1087 msgid "SUN4U-8002-3C.type"
1088 1088 msgstr "Fault"
1089 1089 msgid "SUN4U-8002-3C.severity"
1090 1090 msgstr "Critical"
1091 1091 msgid "SUN4U-8002-3C.description"
1092 1092 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1093 1093 msgid "SUN4U-8002-3C.response"
1094 1094 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1095 1095 msgid "SUN4U-8002-3C.impact"
1096 1096 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1097 1097 msgid "SUN4U-8002-3C.action"
1098 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1098 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1099 1099 #
1100 1100 # code: SUN4U-8002-4J
1101 1101 # keys: fault.io.datapath fault.io.schizo
1102 1102 #
1103 1103 msgid "SUN4U-8002-4J.type"
1104 1104 msgstr "Fault"
1105 1105 msgid "SUN4U-8002-4J.severity"
1106 1106 msgstr "Critical"
1107 1107 msgid "SUN4U-8002-4J.description"
1108 1108 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1109 1109 msgid "SUN4U-8002-4J.response"
1110 1110 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1111 1111 msgid "SUN4U-8002-4J.impact"
1112 1112 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1113 1113 msgid "SUN4U-8002-4J.action"
1114 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1114 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1115 1115 #
1116 1116 # code: SUN4U-8002-5E
1117 1117 # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo
1118 1118 #
1119 1119 msgid "SUN4U-8002-5E.type"
1120 1120 msgstr "Fault"
1121 1121 msgid "SUN4U-8002-5E.severity"
1122 1122 msgstr "Critical"
1123 1123 msgid "SUN4U-8002-5E.description"
1124 1124 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1125 1125 msgid "SUN4U-8002-5E.response"
1126 1126 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1127 1127 msgid "SUN4U-8002-5E.impact"
1128 1128 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1129 1129 msgid "SUN4U-8002-5E.action"
1130 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1130 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1131 1131 #
1132 1132 # code: SUN4U-8002-6X
1133 1133 # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo
1134 1134 #
1135 1135 msgid "SUN4U-8002-6X.type"
1136 1136 msgstr "Fault"
1137 1137 msgid "SUN4U-8002-6X.severity"
1138 1138 msgstr "Critical"
1139 1139 msgid "SUN4U-8002-6X.description"
1140 1140 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1141 1141 msgid "SUN4U-8002-6X.response"
1142 1142 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1143 1143 msgid "SUN4U-8002-6X.impact"
1144 1144 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1145 1145 msgid "SUN4U-8002-6X.action"
1146 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1146 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1147 1147 #
1148 1148 # code: SUN4U-8002-72
1149 1149 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo
1150 1150 #
1151 1151 msgid "SUN4U-8002-72.type"
1152 1152 msgstr "Fault"
1153 1153 msgid "SUN4U-8002-72.severity"
1154 1154 msgstr "Critical"
1155 1155 msgid "SUN4U-8002-72.description"
1156 1156 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1157 1157 msgid "SUN4U-8002-72.response"
1158 1158 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1159 1159 msgid "SUN4U-8002-72.impact"
1160 1160 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1161 1161 msgid "SUN4U-8002-72.action"
1162 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1162 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1163 1163 #
1164 1164 # code: SUN4U-8002-8A
1165 1165 # keys: fault.io.datapath fault.io.pci.device fault.io.schizo
1166 1166 #
1167 1167 msgid "SUN4U-8002-8A.type"
1168 1168 msgstr "Fault"
1169 1169 msgid "SUN4U-8002-8A.severity"
1170 1170 msgstr "Critical"
1171 1171 msgid "SUN4U-8002-8A.description"
1172 1172 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1173 1173 msgid "SUN4U-8002-8A.response"
1174 1174 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1175 1175 msgid "SUN4U-8002-8A.impact"
1176 1176 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1177 1177 msgid "SUN4U-8002-8A.action"
1178 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1178 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1179 1179 #
1180 1180 # code: SUN4U-8002-9P
1181 1181 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo
1182 1182 #
1183 1183 msgid "SUN4U-8002-9P.type"
1184 1184 msgstr "Fault"
1185 1185 msgid "SUN4U-8002-9P.severity"
1186 1186 msgstr "Critical"
1187 1187 msgid "SUN4U-8002-9P.description"
1188 1188 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1189 1189 msgid "SUN4U-8002-9P.response"
1190 1190 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1191 1191 msgid "SUN4U-8002-9P.impact"
1192 1192 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1193 1193 msgid "SUN4U-8002-9P.action"
1194 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1194 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1195 1195 #
1196 1196 # code: SUN4U-8002-A5
1197 1197 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1198 1198 #
1199 1199 msgid "SUN4U-8002-A5.type"
1200 1200 msgstr "Fault"
1201 1201 msgid "SUN4U-8002-A5.severity"
1202 1202 msgstr "Critical"
1203 1203 msgid "SUN4U-8002-A5.description"
1204 1204 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1205 1205 msgid "SUN4U-8002-A5.response"
1206 1206 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1207 1207 msgid "SUN4U-8002-A5.impact"
1208 1208 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1209 1209 msgid "SUN4U-8002-A5.action"
1210 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1210 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1211 1211 #
1212 1212 # code: SUN4U-8002-CS
1213 1213 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1214 1214 #
1215 1215 msgid "SUN4U-8002-CS.type"
1216 1216 msgstr "Fault"
1217 1217 msgid "SUN4U-8002-CS.severity"
1218 1218 msgstr "Critical"
1219 1219 msgid "SUN4U-8002-CS.description"
1220 1220 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1221 1221 msgid "SUN4U-8002-CS.response"
1222 1222 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1223 1223 msgid "SUN4U-8002-CS.impact"
1224 1224 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1225 1225 msgid "SUN4U-8002-CS.action"
1226 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1226 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1227 1227 #
1228 1228 # code: SUN4U-8002-D3
1229 1229 # keys: fault.io.hbus fault.io.schizo
1230 1230 #
1231 1231 msgid "SUN4U-8002-D3.type"
1232 1232 msgstr "Fault"
1233 1233 msgid "SUN4U-8002-D3.severity"
1234 1234 msgstr "Critical"
1235 1235 msgid "SUN4U-8002-D3.description"
1236 1236 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1237 1237 msgid "SUN4U-8002-D3.response"
1238 1238 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1239 1239 msgid "SUN4U-8002-D3.impact"
1240 1240 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1241 1241 msgid "SUN4U-8002-D3.action"
1242 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1242 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1243 1243 #
1244 1244 # code: SUN4U-8002-EY
1245 1245 # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo
1246 1246 #
1247 1247 msgid "SUN4U-8002-EY.type"
1248 1248 msgstr "Fault"
1249 1249 msgid "SUN4U-8002-EY.severity"
1250 1250 msgstr "Critical"
1251 1251 msgid "SUN4U-8002-EY.description"
1252 1252 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1253 1253 msgid "SUN4U-8002-EY.response"
1254 1254 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1255 1255 msgid "SUN4U-8002-EY.impact"
1256 1256 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1257 1257 msgid "SUN4U-8002-EY.action"
1258 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1258 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1259 1259 #
1260 1260 # code: SUN4U-8002-FD
1261 1261 # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo
1262 1262 #
1263 1263 msgid "SUN4U-8002-FD.type"
1264 1264 msgstr "Fault"
1265 1265 msgid "SUN4U-8002-FD.severity"
1266 1266 msgstr "Critical"
1267 1267 msgid "SUN4U-8002-FD.description"
1268 1268 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1269 1269 msgid "SUN4U-8002-FD.response"
1270 1270 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1271 1271 msgid "SUN4U-8002-FD.impact"
1272 1272 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1273 1273 msgid "SUN4U-8002-FD.action"
1274 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1274 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1275 1275 #
1276 1276 # code: SUN4U-8002-GH
1277 1277 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo
1278 1278 #
1279 1279 msgid "SUN4U-8002-GH.type"
1280 1280 msgstr "Fault"
1281 1281 msgid "SUN4U-8002-GH.severity"
1282 1282 msgstr "Critical"
1283 1283 msgid "SUN4U-8002-GH.description"
1284 1284 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1285 1285 msgid "SUN4U-8002-GH.response"
1286 1286 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1287 1287 msgid "SUN4U-8002-GH.impact"
1288 1288 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1289 1289 msgid "SUN4U-8002-GH.action"
1290 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1290 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1291 1291 #
1292 1292 # code: SUN4U-8002-HC
1293 1293 # keys: fault.io.hbus fault.io.pci.device fault.io.schizo
1294 1294 #
1295 1295 msgid "SUN4U-8002-HC.type"
1296 1296 msgstr "Fault"
1297 1297 msgid "SUN4U-8002-HC.severity"
1298 1298 msgstr "Critical"
1299 1299 msgid "SUN4U-8002-HC.description"
1300 1300 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1301 1301 msgid "SUN4U-8002-HC.response"
1302 1302 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1303 1303 msgid "SUN4U-8002-HC.impact"
1304 1304 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1305 1305 msgid "SUN4U-8002-HC.action"
1306 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1306 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1307 1307 #
1308 1308 # code: SUN4U-8002-JQ
1309 1309 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo
1310 1310 #
1311 1311 msgid "SUN4U-8002-JQ.type"
1312 1312 msgstr "Fault"
1313 1313 msgid "SUN4U-8002-JQ.severity"
1314 1314 msgstr "Critical"
1315 1315 msgid "SUN4U-8002-JQ.description"
1316 1316 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1317 1317 msgid "SUN4U-8002-JQ.response"
1318 1318 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1319 1319 msgid "SUN4U-8002-JQ.impact"
1320 1320 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1321 1321 msgid "SUN4U-8002-JQ.action"
1322 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1322 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1323 1323 #
1324 1324 # code: SUN4U-8002-K4
1325 1325 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1326 1326 #
1327 1327 msgid "SUN4U-8002-K4.type"
1328 1328 msgstr "Fault"
1329 1329 msgid "SUN4U-8002-K4.severity"
1330 1330 msgstr "Critical"
1331 1331 msgid "SUN4U-8002-K4.description"
1332 1332 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1333 1333 msgid "SUN4U-8002-K4.response"
1334 1334 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1335 1335 msgid "SUN4U-8002-K4.impact"
1336 1336 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1337 1337 msgid "SUN4U-8002-K4.action"
1338 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1338 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1339 1339 #
1340 1340 # code: SUN4U-8002-LR
1341 1341 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1342 1342 #
1343 1343 msgid "SUN4U-8002-LR.type"
1344 1344 msgstr "Fault"
1345 1345 msgid "SUN4U-8002-LR.severity"
1346 1346 msgstr "Critical"
1347 1347 msgid "SUN4U-8002-LR.description"
1348 1348 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1349 1349 msgid "SUN4U-8002-LR.response"
1350 1350 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1351 1351 msgid "SUN4U-8002-LR.impact"
1352 1352 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1353 1353 msgid "SUN4U-8002-LR.action"
1354 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1354 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1355 1355 #
1356 1356 # code: SUN4U-8002-M2
1357 1357 # keys: fault.io.datapath fault.io.hbus fault.io.schizo
1358 1358 #
1359 1359 msgid "SUN4U-8002-M2.type"
1360 1360 msgstr "Fault"
1361 1361 msgid "SUN4U-8002-M2.severity"
1362 1362 msgstr "Critical"
1363 1363 msgid "SUN4U-8002-M2.description"
1364 1364 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1365 1365 msgid "SUN4U-8002-M2.response"
1366 1366 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1367 1367 msgid "SUN4U-8002-M2.impact"
1368 1368 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1369 1369 msgid "SUN4U-8002-M2.action"
1370 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1370 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1371 1371 #
1372 1372 # code: SUN4U-8002-NX
1373 1373 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo
1374 1374 #
1375 1375 msgid "SUN4U-8002-NX.type"
1376 1376 msgstr "Fault"
1377 1377 msgid "SUN4U-8002-NX.severity"
1378 1378 msgstr "Critical"
1379 1379 msgid "SUN4U-8002-NX.description"
1380 1380 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1381 1381 msgid "SUN4U-8002-NX.response"
1382 1382 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1383 1383 msgid "SUN4U-8002-NX.impact"
1384 1384 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1385 1385 msgid "SUN4U-8002-NX.action"
1386 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1386 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1387 1387 #
1388 1388 # code: SUN4U-8002-PE
1389 1389 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1390 1390 #
1391 1391 msgid "SUN4U-8002-PE.type"
1392 1392 msgstr "Fault"
1393 1393 msgid "SUN4U-8002-PE.severity"
1394 1394 msgstr "Critical"
1395 1395 msgid "SUN4U-8002-PE.description"
1396 1396 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1397 1397 msgid "SUN4U-8002-PE.response"
1398 1398 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1399 1399 msgid "SUN4U-8002-PE.impact"
1400 1400 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1401 1401 msgid "SUN4U-8002-PE.action"
1402 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1402 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1403 1403 #
1404 1404 # code: SUN4U-8002-QJ
1405 1405 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1406 1406 #
1407 1407 msgid "SUN4U-8002-QJ.type"
1408 1408 msgstr "Fault"
1409 1409 msgid "SUN4U-8002-QJ.severity"
1410 1410 msgstr "Critical"
1411 1411 msgid "SUN4U-8002-QJ.description"
1412 1412 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1413 1413 msgid "SUN4U-8002-QJ.response"
1414 1414 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1415 1415 msgid "SUN4U-8002-QJ.impact"
1416 1416 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1417 1417 msgid "SUN4U-8002-QJ.action"
1418 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1418 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1419 1419 #
1420 1420 # code: SUN4U-8002-RS
1421 1421 # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1422 1422 #
1423 1423 msgid "SUN4U-8002-RS.type"
1424 1424 msgstr "Fault"
1425 1425 msgid "SUN4U-8002-RS.severity"
1426 1426 msgstr "Critical"
1427 1427 msgid "SUN4U-8002-RS.description"
1428 1428 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1429 1429 msgid "SUN4U-8002-RS.response"
1430 1430 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1431 1431 msgid "SUN4U-8002-RS.impact"
1432 1432 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1433 1433 msgid "SUN4U-8002-RS.action"
1434 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1434 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1435 1435 #
1436 1436 # code: SUN4U-8002-S5
1437 1437 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1438 1438 #
1439 1439 msgid "SUN4U-8002-S5.type"
1440 1440 msgstr "Fault"
1441 1441 msgid "SUN4U-8002-S5.severity"
1442 1442 msgstr "Critical"
1443 1443 msgid "SUN4U-8002-S5.description"
1444 1444 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1445 1445 msgid "SUN4U-8002-S5.response"
1446 1446 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1447 1447 msgid "SUN4U-8002-S5.impact"
1448 1448 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1449 1449 msgid "SUN4U-8002-S5.action"
1450 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1450 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1451 1451 #
1452 1452 # code: SUN4U-8002-TP
1453 1453 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1454 1454 #
1455 1455 msgid "SUN4U-8002-TP.type"
1456 1456 msgstr "Fault"
1457 1457 msgid "SUN4U-8002-TP.severity"
1458 1458 msgstr "Critical"
1459 1459 msgid "SUN4U-8002-TP.description"
1460 1460 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1461 1461 msgid "SUN4U-8002-TP.response"
1462 1462 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1463 1463 msgid "SUN4U-8002-TP.impact"
1464 1464 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1465 1465 msgid "SUN4U-8002-TP.action"
1466 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1466 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1467 1467 #
1468 1468 # code: SUN4U-8002-UA
1469 1469 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1470 1470 #
1471 1471 msgid "SUN4U-8002-UA.type"
1472 1472 msgstr "Fault"
1473 1473 msgid "SUN4U-8002-UA.severity"
1474 1474 msgstr "Critical"
1475 1475 msgid "SUN4U-8002-UA.description"
1476 1476 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1477 1477 msgid "SUN4U-8002-UA.response"
1478 1478 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1479 1479 msgid "SUN4U-8002-UA.impact"
1480 1480 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1481 1481 msgid "SUN4U-8002-UA.action"
1482 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1482 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1483 1483 #
1484 1484 # code: SUN4U-8002-VH
1485 1485 # keys: fault.io.xmits
1486 1486 #
1487 1487 msgid "SUN4U-8002-VH.type"
1488 1488 msgstr "Fault"
1489 1489 msgid "SUN4U-8002-VH.severity"
1490 1490 msgstr "Critical"
1491 1491 msgid "SUN4U-8002-VH.description"
1492 1492 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1493 1493 msgid "SUN4U-8002-VH.response"
1494 1494 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1495 1495 msgid "SUN4U-8002-VH.impact"
1496 1496 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1497 1497 msgid "SUN4U-8002-VH.action"
1498 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1498 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1499 1499 #
1500 1500 # code: SUN4U-8002-WD
1501 1501 # keys: defect.io.pci.driver fault.io.xmits
1502 1502 #
1503 1503 msgid "SUN4U-8002-WD.type"
1504 1504 msgstr "Fault"
1505 1505 msgid "SUN4U-8002-WD.severity"
1506 1506 msgstr "Critical"
1507 1507 msgid "SUN4U-8002-WD.description"
1508 1508 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1509 1509 msgid "SUN4U-8002-WD.response"
1510 1510 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1511 1511 msgid "SUN4U-8002-WD.impact"
1512 1512 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1513 1513 msgid "SUN4U-8002-WD.action"
1514 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1514 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1515 1515 #
1516 1516 # code: SUN4U-8002-XY
1517 1517 # keys: fault.io.pci.bus fault.io.xmits
1518 1518 #
1519 1519 msgid "SUN4U-8002-XY.type"
1520 1520 msgstr "Fault"
1521 1521 msgid "SUN4U-8002-XY.severity"
1522 1522 msgstr "Critical"
1523 1523 msgid "SUN4U-8002-XY.description"
1524 1524 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1525 1525 msgid "SUN4U-8002-XY.response"
1526 1526 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1527 1527 msgid "SUN4U-8002-XY.impact"
1528 1528 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1529 1529 msgid "SUN4U-8002-XY.action"
1530 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1530 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1531 1531 #
1532 1532 # code: SUN4U-8002-Y3
1533 1533 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits
1534 1534 #
1535 1535 msgid "SUN4U-8002-Y3.type"
1536 1536 msgstr "Fault"
1537 1537 msgid "SUN4U-8002-Y3.severity"
1538 1538 msgstr "Critical"
1539 1539 msgid "SUN4U-8002-Y3.description"
1540 1540 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1541 1541 msgid "SUN4U-8002-Y3.response"
1542 1542 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1543 1543 msgid "SUN4U-8002-Y3.impact"
1544 1544 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1545 1545 msgid "SUN4U-8002-Y3.action"
1546 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1546 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1547 1547 #
1548 1548 # code: SUN4U-8003-0Y
1549 1549 # keys: fault.io.pci.device fault.io.xmits
1550 1550 #
1551 1551 msgid "SUN4U-8003-0Y.type"
1552 1552 msgstr "Fault"
1553 1553 msgid "SUN4U-8003-0Y.severity"
1554 1554 msgstr "Critical"
1555 1555 msgid "SUN4U-8003-0Y.description"
1556 1556 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1557 1557 msgid "SUN4U-8003-0Y.response"
1558 1558 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1559 1559 msgid "SUN4U-8003-0Y.impact"
1560 1560 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1561 1561 msgid "SUN4U-8003-0Y.action"
1562 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1562 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1563 1563 #
1564 1564 # code: SUN4U-8003-13
1565 1565 # keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits
1566 1566 #
1567 1567 msgid "SUN4U-8003-13.type"
1568 1568 msgstr "Fault"
1569 1569 msgid "SUN4U-8003-13.severity"
1570 1570 msgstr "Critical"
1571 1571 msgid "SUN4U-8003-13.description"
1572 1572 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1573 1573 msgid "SUN4U-8003-13.response"
1574 1574 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1575 1575 msgid "SUN4U-8003-13.impact"
1576 1576 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1577 1577 msgid "SUN4U-8003-13.action"
1578 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1578 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1579 1579 #
1580 1580 # code: SUN4U-8003-2H
1581 1581 # keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits
1582 1582 #
1583 1583 msgid "SUN4U-8003-2H.type"
1584 1584 msgstr "Fault"
1585 1585 msgid "SUN4U-8003-2H.severity"
1586 1586 msgstr "Critical"
1587 1587 msgid "SUN4U-8003-2H.description"
1588 1588 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1589 1589 msgid "SUN4U-8003-2H.response"
1590 1590 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1591 1591 msgid "SUN4U-8003-2H.impact"
1592 1592 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1593 1593 msgid "SUN4U-8003-2H.action"
1594 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1594 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1595 1595 #
1596 1596 # code: SUN4U-8003-3D
1597 1597 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits
1598 1598 #
1599 1599 msgid "SUN4U-8003-3D.type"
1600 1600 msgstr "Fault"
1601 1601 msgid "SUN4U-8003-3D.severity"
1602 1602 msgstr "Critical"
1603 1603 msgid "SUN4U-8003-3D.description"
1604 1604 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1605 1605 msgid "SUN4U-8003-3D.response"
1606 1606 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1607 1607 msgid "SUN4U-8003-3D.impact"
1608 1608 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1609 1609 msgid "SUN4U-8003-3D.action"
1610 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1610 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1611 1611 #
1612 1612 # code: SUN4U-8003-4P
1613 1613 # keys: fault.io.datapath fault.io.xmits
1614 1614 #
1615 1615 msgid "SUN4U-8003-4P.type"
1616 1616 msgstr "Fault"
1617 1617 msgid "SUN4U-8003-4P.severity"
1618 1618 msgstr "Critical"
1619 1619 msgid "SUN4U-8003-4P.description"
1620 1620 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1621 1621 msgid "SUN4U-8003-4P.response"
1622 1622 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1623 1623 msgid "SUN4U-8003-4P.impact"
1624 1624 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1625 1625 msgid "SUN4U-8003-4P.action"
1626 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1626 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1627 1627 #
1628 1628 # code: SUN4U-8003-5A
1629 1629 # keys: defect.io.pci.driver fault.io.datapath fault.io.xmits
1630 1630 #
1631 1631 msgid "SUN4U-8003-5A.type"
1632 1632 msgstr "Fault"
1633 1633 msgid "SUN4U-8003-5A.severity"
1634 1634 msgstr "Critical"
1635 1635 msgid "SUN4U-8003-5A.description"
1636 1636 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1637 1637 msgid "SUN4U-8003-5A.response"
1638 1638 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1639 1639 msgid "SUN4U-8003-5A.impact"
1640 1640 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1641 1641 msgid "SUN4U-8003-5A.action"
1642 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1642 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1643 1643 #
1644 1644 # code: SUN4U-8003-6S
1645 1645 # keys: fault.io.datapath fault.io.pci.bus fault.io.xmits
1646 1646 #
1647 1647 msgid "SUN4U-8003-6S.type"
1648 1648 msgstr "Fault"
1649 1649 msgid "SUN4U-8003-6S.severity"
1650 1650 msgstr "Critical"
1651 1651 msgid "SUN4U-8003-6S.description"
1652 1652 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1653 1653 msgid "SUN4U-8003-6S.response"
1654 1654 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1655 1655 msgid "SUN4U-8003-6S.impact"
1656 1656 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1657 1657 msgid "SUN4U-8003-6S.action"
1658 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1658 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1659 1659 #
1660 1660 # code: SUN4U-8003-75
1661 1661 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits
1662 1662 #
1663 1663 msgid "SUN4U-8003-75.type"
1664 1664 msgstr "Fault"
1665 1665 msgid "SUN4U-8003-75.severity"
1666 1666 msgstr "Critical"
1667 1667 msgid "SUN4U-8003-75.description"
1668 1668 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1669 1669 msgid "SUN4U-8003-75.response"
1670 1670 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1671 1671 msgid "SUN4U-8003-75.impact"
1672 1672 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1673 1673 msgid "SUN4U-8003-75.action"
1674 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1674 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1675 1675 #
1676 1676 # code: SUN4U-8003-8E
1677 1677 # keys: fault.io.datapath fault.io.pci.device fault.io.xmits
1678 1678 #
1679 1679 msgid "SUN4U-8003-8E.type"
1680 1680 msgstr "Fault"
1681 1681 msgid "SUN4U-8003-8E.severity"
1682 1682 msgstr "Critical"
1683 1683 msgid "SUN4U-8003-8E.description"
1684 1684 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1685 1685 msgid "SUN4U-8003-8E.response"
1686 1686 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1687 1687 msgid "SUN4U-8003-8E.impact"
1688 1688 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1689 1689 msgid "SUN4U-8003-8E.action"
1690 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1690 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1691 1691 #
1692 1692 # code: SUN4U-8003-9J
1693 1693 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits
1694 1694 #
1695 1695 msgid "SUN4U-8003-9J.type"
1696 1696 msgstr "Fault"
1697 1697 msgid "SUN4U-8003-9J.severity"
1698 1698 msgstr "Critical"
1699 1699 msgid "SUN4U-8003-9J.description"
1700 1700 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1701 1701 msgid "SUN4U-8003-9J.response"
1702 1702 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1703 1703 msgid "SUN4U-8003-9J.impact"
1704 1704 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1705 1705 msgid "SUN4U-8003-9J.action"
1706 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1706 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1707 1707 #
1708 1708 # code: SUN4U-8003-A2
1709 1709 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1710 1710 #
1711 1711 msgid "SUN4U-8003-A2.type"
1712 1712 msgstr "Fault"
1713 1713 msgid "SUN4U-8003-A2.severity"
1714 1714 msgstr "Critical"
1715 1715 msgid "SUN4U-8003-A2.description"
1716 1716 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1717 1717 msgid "SUN4U-8003-A2.response"
1718 1718 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1719 1719 msgid "SUN4U-8003-A2.impact"
1720 1720 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1721 1721 msgid "SUN4U-8003-A2.action"
1722 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1722 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1723 1723 #
1724 1724 # code: SUN4U-8003-CX
1725 1725 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1726 1726 #
1727 1727 msgid "SUN4U-8003-CX.type"
1728 1728 msgstr "Fault"
1729 1729 msgid "SUN4U-8003-CX.severity"
1730 1730 msgstr "Critical"
1731 1731 msgid "SUN4U-8003-CX.description"
1732 1732 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1733 1733 msgid "SUN4U-8003-CX.response"
1734 1734 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1735 1735 msgid "SUN4U-8003-CX.impact"
1736 1736 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1737 1737 msgid "SUN4U-8003-CX.action"
1738 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1738 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1739 1739 #
1740 1740 # code: SUN4U-8003-D4
1741 1741 # keys: fault.io.hbus fault.io.xmits
1742 1742 #
1743 1743 msgid "SUN4U-8003-D4.type"
1744 1744 msgstr "Fault"
1745 1745 msgid "SUN4U-8003-D4.severity"
1746 1746 msgstr "Critical"
1747 1747 msgid "SUN4U-8003-D4.description"
1748 1748 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1749 1749 msgid "SUN4U-8003-D4.response"
1750 1750 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1751 1751 msgid "SUN4U-8003-D4.impact"
1752 1752 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1753 1753 msgid "SUN4U-8003-D4.action"
1754 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1754 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1755 1755 #
1756 1756 # code: SUN4U-8003-ER
1757 1757 # keys: defect.io.pci.driver fault.io.hbus fault.io.xmits
1758 1758 #
1759 1759 msgid "SUN4U-8003-ER.type"
1760 1760 msgstr "Fault"
1761 1761 msgid "SUN4U-8003-ER.severity"
1762 1762 msgstr "Critical"
1763 1763 msgid "SUN4U-8003-ER.description"
1764 1764 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1765 1765 msgid "SUN4U-8003-ER.response"
1766 1766 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1767 1767 msgid "SUN4U-8003-ER.impact"
1768 1768 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1769 1769 msgid "SUN4U-8003-ER.action"
1770 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1770 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1771 1771 #
1772 1772 # code: SUN4U-8003-FC
1773 1773 # keys: fault.io.hbus fault.io.pci.bus fault.io.xmits
1774 1774 #
1775 1775 msgid "SUN4U-8003-FC.type"
1776 1776 msgstr "Fault"
1777 1777 msgid "SUN4U-8003-FC.severity"
1778 1778 msgstr "Critical"
1779 1779 msgid "SUN4U-8003-FC.description"
1780 1780 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1781 1781 msgid "SUN4U-8003-FC.response"
1782 1782 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1783 1783 msgid "SUN4U-8003-FC.impact"
1784 1784 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1785 1785 msgid "SUN4U-8003-FC.action"
1786 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1786 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1787 1787 #
1788 1788 # code: SUN4U-8003-GQ
1789 1789 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits
1790 1790 #
1791 1791 msgid "SUN4U-8003-GQ.type"
1792 1792 msgstr "Fault"
1793 1793 msgid "SUN4U-8003-GQ.severity"
1794 1794 msgstr "Critical"
1795 1795 msgid "SUN4U-8003-GQ.description"
1796 1796 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1797 1797 msgid "SUN4U-8003-GQ.response"
1798 1798 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1799 1799 msgid "SUN4U-8003-GQ.impact"
1800 1800 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1801 1801 msgid "SUN4U-8003-GQ.action"
1802 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1802 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1803 1803 #
1804 1804 # code: SUN4U-8003-HD
1805 1805 # keys: fault.io.hbus fault.io.pci.device fault.io.xmits
1806 1806 #
1807 1807 msgid "SUN4U-8003-HD.type"
1808 1808 msgstr "Fault"
1809 1809 msgid "SUN4U-8003-HD.severity"
1810 1810 msgstr "Critical"
1811 1811 msgid "SUN4U-8003-HD.description"
1812 1812 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1813 1813 msgid "SUN4U-8003-HD.response"
1814 1814 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1815 1815 msgid "SUN4U-8003-HD.impact"
1816 1816 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1817 1817 msgid "SUN4U-8003-HD.action"
1818 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1818 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1819 1819 #
1820 1820 # code: SUN4U-8003-JH
1821 1821 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits
1822 1822 #
1823 1823 msgid "SUN4U-8003-JH.type"
1824 1824 msgstr "Fault"
1825 1825 msgid "SUN4U-8003-JH.severity"
1826 1826 msgstr "Critical"
1827 1827 msgid "SUN4U-8003-JH.description"
1828 1828 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1829 1829 msgid "SUN4U-8003-JH.response"
1830 1830 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1831 1831 msgid "SUN4U-8003-JH.impact"
1832 1832 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1833 1833 msgid "SUN4U-8003-JH.action"
1834 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1834 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1835 1835 #
1836 1836 # code: SUN4U-8003-K3
1837 1837 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1838 1838 #
1839 1839 msgid "SUN4U-8003-K3.type"
1840 1840 msgstr "Fault"
1841 1841 msgid "SUN4U-8003-K3.severity"
1842 1842 msgstr "Critical"
1843 1843 msgid "SUN4U-8003-K3.description"
1844 1844 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1845 1845 msgid "SUN4U-8003-K3.response"
1846 1846 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1847 1847 msgid "SUN4U-8003-K3.impact"
1848 1848 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1849 1849 msgid "SUN4U-8003-K3.action"
1850 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1850 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1851 1851 #
1852 1852 # code: SUN4U-8003-LY
1853 1853 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1854 1854 #
1855 1855 msgid "SUN4U-8003-LY.type"
1856 1856 msgstr "Fault"
1857 1857 msgid "SUN4U-8003-LY.severity"
1858 1858 msgstr "Critical"
1859 1859 msgid "SUN4U-8003-LY.description"
1860 1860 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1861 1861 msgid "SUN4U-8003-LY.response"
1862 1862 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1863 1863 msgid "SUN4U-8003-LY.impact"
1864 1864 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1865 1865 msgid "SUN4U-8003-LY.action"
1866 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1866 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1867 1867 #
1868 1868 # code: SUN4U-8003-M5
1869 1869 # keys: fault.io.datapath fault.io.hbus fault.io.xmits
1870 1870 #
1871 1871 msgid "SUN4U-8003-M5.type"
1872 1872 msgstr "Fault"
1873 1873 msgid "SUN4U-8003-M5.severity"
1874 1874 msgstr "Critical"
1875 1875 msgid "SUN4U-8003-M5.description"
1876 1876 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1877 1877 msgid "SUN4U-8003-M5.response"
1878 1878 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1879 1879 msgid "SUN4U-8003-M5.impact"
1880 1880 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1881 1881 msgid "SUN4U-8003-M5.action"
1882 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1882 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1883 1883 #
1884 1884 # code: SUN4U-8003-NS
1885 1885 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits
1886 1886 #
1887 1887 msgid "SUN4U-8003-NS.type"
1888 1888 msgstr "Fault"
1889 1889 msgid "SUN4U-8003-NS.severity"
1890 1890 msgstr "Critical"
1891 1891 msgid "SUN4U-8003-NS.description"
1892 1892 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1893 1893 msgid "SUN4U-8003-NS.response"
1894 1894 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1895 1895 msgid "SUN4U-8003-NS.impact"
1896 1896 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1897 1897 msgid "SUN4U-8003-NS.action"
1898 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1898 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1899 1899 #
1900 1900 # code: SUN4U-8003-PA
1901 1901 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1902 1902 #
1903 1903 msgid "SUN4U-8003-PA.type"
1904 1904 msgstr "Fault"
1905 1905 msgid "SUN4U-8003-PA.severity"
1906 1906 msgstr "Critical"
1907 1907 msgid "SUN4U-8003-PA.description"
1908 1908 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1909 1909 msgid "SUN4U-8003-PA.response"
1910 1910 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1911 1911 msgid "SUN4U-8003-PA.impact"
1912 1912 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1913 1913 msgid "SUN4U-8003-PA.action"
1914 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1914 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1915 1915 #
1916 1916 # code: SUN4U-8003-QP
1917 1917 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1918 1918 #
1919 1919 msgid "SUN4U-8003-QP.type"
1920 1920 msgstr "Fault"
1921 1921 msgid "SUN4U-8003-QP.severity"
1922 1922 msgstr "Critical"
1923 1923 msgid "SUN4U-8003-QP.description"
1924 1924 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1925 1925 msgid "SUN4U-8003-QP.response"
1926 1926 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1927 1927 msgid "SUN4U-8003-QP.impact"
1928 1928 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1929 1929 msgid "SUN4U-8003-QP.action"
1930 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1930 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1931 1931 #
1932 1932 # code: SUN4U-8003-RX
1933 1933 # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1934 1934 #
1935 1935 msgid "SUN4U-8003-RX.type"
1936 1936 msgstr "Fault"
1937 1937 msgid "SUN4U-8003-RX.severity"
1938 1938 msgstr "Critical"
1939 1939 msgid "SUN4U-8003-RX.description"
1940 1940 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1941 1941 msgid "SUN4U-8003-RX.response"
1942 1942 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1943 1943 msgid "SUN4U-8003-RX.impact"
1944 1944 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1945 1945 msgid "SUN4U-8003-RX.action"
1946 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1946 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1947 1947 #
1948 1948 # code: SUN4U-8003-S2
1949 1949 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1950 1950 #
1951 1951 msgid "SUN4U-8003-S2.type"
1952 1952 msgstr "Fault"
1953 1953 msgid "SUN4U-8003-S2.severity"
1954 1954 msgstr "Critical"
1955 1955 msgid "SUN4U-8003-S2.description"
1956 1956 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1957 1957 msgid "SUN4U-8003-S2.response"
1958 1958 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1959 1959 msgid "SUN4U-8003-S2.impact"
1960 1960 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1961 1961 msgid "SUN4U-8003-S2.action"
1962 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1962 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1963 1963 #
1964 1964 # code: SUN4U-8003-TJ
1965 1965 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1966 1966 #
1967 1967 msgid "SUN4U-8003-TJ.type"
1968 1968 msgstr "Fault"
1969 1969 msgid "SUN4U-8003-TJ.severity"
1970 1970 msgstr "Critical"
1971 1971 msgid "SUN4U-8003-TJ.description"
1972 1972 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
1973 1973 msgid "SUN4U-8003-TJ.response"
1974 1974 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1975 1975 msgid "SUN4U-8003-TJ.impact"
1976 1976 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1977 1977 msgid "SUN4U-8003-TJ.action"
1978 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1978 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
1979 1979 #
1980 1980 # code: SUN4U-8003-UE
1981 1981 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1982 1982 #
1983 1983 msgid "SUN4U-8003-UE.type"
1984 1984 msgstr "Fault"
1985 1985 msgid "SUN4U-8003-UE.severity"
1986 1986 msgstr "Critical"
1987 1987 msgid "SUN4U-8003-UE.description"
1988 1988 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
1989 1989 msgid "SUN4U-8003-UE.response"
1990 1990 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1991 1991 msgid "SUN4U-8003-UE.impact"
1992 1992 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1993 1993 msgid "SUN4U-8003-UE.action"
1994 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1994 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
1995 1995 #
1996 1996 # code: SUN4U-8003-VQ
1997 1997 # keys: fault.io.schizo fault.io.xmits
1998 1998 #
1999 1999 msgid "SUN4U-8003-VQ.type"
2000 2000 msgstr "Fault"
2001 2001 msgid "SUN4U-8003-VQ.severity"
2002 2002 msgstr "Critical"
2003 2003 msgid "SUN4U-8003-VQ.description"
2004 2004 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2005 2005 msgid "SUN4U-8003-VQ.response"
2006 2006 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2007 2007 msgid "SUN4U-8003-VQ.impact"
2008 2008 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2009 2009 msgid "SUN4U-8003-VQ.action"
2010 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2010 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2011 2011 #
2012 2012 # code: SUN4U-8003-WC
2013 2013 # keys: defect.io.pci.driver fault.io.schizo fault.io.xmits
2014 2014 #
2015 2015 msgid "SUN4U-8003-WC.type"
2016 2016 msgstr "Fault"
2017 2017 msgid "SUN4U-8003-WC.severity"
2018 2018 msgstr "Critical"
2019 2019 msgid "SUN4U-8003-WC.description"
2020 2020 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2021 2021 msgid "SUN4U-8003-WC.response"
2022 2022 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2023 2023 msgid "SUN4U-8003-WC.impact"
2024 2024 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2025 2025 msgid "SUN4U-8003-WC.action"
2026 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2026 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2027 2027 #
2028 2028 # code: SUN4U-8003-XR
2029 2029 # keys: fault.io.pci.bus fault.io.schizo fault.io.xmits
2030 2030 #
2031 2031 msgid "SUN4U-8003-XR.type"
2032 2032 msgstr "Fault"
2033 2033 msgid "SUN4U-8003-XR.severity"
2034 2034 msgstr "Critical"
2035 2035 msgid "SUN4U-8003-XR.description"
2036 2036 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2037 2037 msgid "SUN4U-8003-XR.response"
2038 2038 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2039 2039 msgid "SUN4U-8003-XR.impact"
2040 2040 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2041 2041 msgid "SUN4U-8003-XR.action"
2042 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2042 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2043 2043 #
2044 2044 # code: SUN4U-8003-Y4
2045 2045 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits
2046 2046 #
2047 2047 msgid "SUN4U-8003-Y4.type"
2048 2048 msgstr "Fault"
2049 2049 msgid "SUN4U-8003-Y4.severity"
2050 2050 msgstr "Critical"
2051 2051 msgid "SUN4U-8003-Y4.description"
2052 2052 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2053 2053 msgid "SUN4U-8003-Y4.response"
2054 2054 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2055 2055 msgid "SUN4U-8003-Y4.impact"
2056 2056 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2057 2057 msgid "SUN4U-8003-Y4.action"
2058 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2058 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2059 2059 #
2060 2060 # code: SUN4U-8004-0A
2061 2061 # keys: fault.io.pci.device fault.io.schizo fault.io.xmits
2062 2062 #
2063 2063 msgid "SUN4U-8004-0A.type"
2064 2064 msgstr "Fault"
2065 2065 msgid "SUN4U-8004-0A.severity"
2066 2066 msgstr "Critical"
2067 2067 msgid "SUN4U-8004-0A.description"
2068 2068 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2069 2069 msgid "SUN4U-8004-0A.response"
2070 2070 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2071 2071 msgid "SUN4U-8004-0A.impact"
2072 2072 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2073 2073 msgid "SUN4U-8004-0A.action"
2074 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2074 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2075 2075 #
2076 2076 # code: SUN4U-8004-1P
2077 2077 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits
2078 2078 #
2079 2079 msgid "SUN4U-8004-1P.type"
2080 2080 msgstr "Fault"
2081 2081 msgid "SUN4U-8004-1P.severity"
2082 2082 msgstr "Critical"
2083 2083 msgid "SUN4U-8004-1P.description"
2084 2084 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2085 2085 msgid "SUN4U-8004-1P.response"
2086 2086 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2087 2087 msgid "SUN4U-8004-1P.impact"
2088 2088 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2089 2089 msgid "SUN4U-8004-1P.action"
2090 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2090 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2091 2091 #
2092 2092 # code: SUN4U-8004-25
2093 2093 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2094 2094 #
2095 2095 msgid "SUN4U-8004-25.type"
2096 2096 msgstr "Fault"
2097 2097 msgid "SUN4U-8004-25.severity"
2098 2098 msgstr "Critical"
2099 2099 msgid "SUN4U-8004-25.description"
2100 2100 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2101 2101 msgid "SUN4U-8004-25.response"
2102 2102 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2103 2103 msgid "SUN4U-8004-25.impact"
2104 2104 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2105 2105 msgid "SUN4U-8004-25.action"
2106 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2106 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2107 2107 #
2108 2108 # code: SUN4U-8004-3S
2109 2109 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2110 2110 #
2111 2111 msgid "SUN4U-8004-3S.type"
2112 2112 msgstr "Fault"
2113 2113 msgid "SUN4U-8004-3S.severity"
2114 2114 msgstr "Critical"
2115 2115 msgid "SUN4U-8004-3S.description"
2116 2116 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2117 2117 msgid "SUN4U-8004-3S.response"
2118 2118 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2119 2119 msgid "SUN4U-8004-3S.impact"
2120 2120 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2121 2121 msgid "SUN4U-8004-3S.action"
2122 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2122 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2123 2123 #
2124 2124 # code: SUN4U-8004-43
2125 2125 # keys: fault.io.datapath fault.io.schizo fault.io.xmits
2126 2126 #
2127 2127 msgid "SUN4U-8004-43.type"
2128 2128 msgstr "Fault"
2129 2129 msgid "SUN4U-8004-43.severity"
2130 2130 msgstr "Critical"
2131 2131 msgid "SUN4U-8004-43.description"
2132 2132 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2133 2133 msgid "SUN4U-8004-43.response"
2134 2134 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2135 2135 msgid "SUN4U-8004-43.impact"
2136 2136 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2137 2137 msgid "SUN4U-8004-43.action"
2138 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2138 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2139 2139 #
2140 2140 # code: SUN4U-8004-5Y
2141 2141 # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits
2142 2142 #
2143 2143 msgid "SUN4U-8004-5Y.type"
2144 2144 msgstr "Fault"
2145 2145 msgid "SUN4U-8004-5Y.severity"
2146 2146 msgstr "Critical"
2147 2147 msgid "SUN4U-8004-5Y.description"
2148 2148 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2149 2149 msgid "SUN4U-8004-5Y.response"
2150 2150 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2151 2151 msgid "SUN4U-8004-5Y.impact"
2152 2152 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2153 2153 msgid "SUN4U-8004-5Y.action"
2154 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2154 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2155 2155 #
2156 2156 # code: SUN4U-8004-6D
2157 2157 # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2158 2158 #
2159 2159 msgid "SUN4U-8004-6D.type"
2160 2160 msgstr "Fault"
2161 2161 msgid "SUN4U-8004-6D.severity"
2162 2162 msgstr "Critical"
2163 2163 msgid "SUN4U-8004-6D.description"
2164 2164 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2165 2165 msgid "SUN4U-8004-6D.response"
2166 2166 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2167 2167 msgid "SUN4U-8004-6D.impact"
2168 2168 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2169 2169 msgid "SUN4U-8004-6D.action"
2170 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2170 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2171 2171 #
2172 2172 # code: SUN4U-8004-7H
2173 2173 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2174 2174 #
2175 2175 msgid "SUN4U-8004-7H.type"
2176 2176 msgstr "Fault"
2177 2177 msgid "SUN4U-8004-7H.severity"
2178 2178 msgstr "Critical"
2179 2179 msgid "SUN4U-8004-7H.description"
2180 2180 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2181 2181 msgid "SUN4U-8004-7H.response"
2182 2182 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2183 2183 msgid "SUN4U-8004-7H.impact"
2184 2184 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2185 2185 msgid "SUN4U-8004-7H.action"
2186 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2186 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2187 2187 #
2188 2188 # code: SUN4U-8004-8R
2189 2189 # keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2190 2190 #
2191 2191 msgid "SUN4U-8004-8R.type"
2192 2192 msgstr "Fault"
2193 2193 msgid "SUN4U-8004-8R.severity"
2194 2194 msgstr "Critical"
2195 2195 msgid "SUN4U-8004-8R.description"
2196 2196 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2197 2197 msgid "SUN4U-8004-8R.response"
2198 2198 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2199 2199 msgid "SUN4U-8004-8R.impact"
2200 2200 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2201 2201 msgid "SUN4U-8004-8R.action"
2202 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2202 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2203 2203 #
2204 2204 # code: SUN4U-8004-94
2205 2205 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2206 2206 #
2207 2207 msgid "SUN4U-8004-94.type"
2208 2208 msgstr "Fault"
2209 2209 msgid "SUN4U-8004-94.severity"
2210 2210 msgstr "Critical"
2211 2211 msgid "SUN4U-8004-94.description"
2212 2212 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2213 2213 msgid "SUN4U-8004-94.response"
2214 2214 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2215 2215 msgid "SUN4U-8004-94.impact"
2216 2216 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2217 2217 msgid "SUN4U-8004-94.action"
2218 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2218 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2219 2219 #
2220 2220 # code: SUN4U-8004-AQ
2221 2221 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2222 2222 #
2223 2223 msgid "SUN4U-8004-AQ.type"
2224 2224 msgstr "Fault"
2225 2225 msgid "SUN4U-8004-AQ.severity"
2226 2226 msgstr "Critical"
2227 2227 msgid "SUN4U-8004-AQ.description"
2228 2228 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2229 2229 msgid "SUN4U-8004-AQ.response"
2230 2230 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2231 2231 msgid "SUN4U-8004-AQ.impact"
2232 2232 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2233 2233 msgid "SUN4U-8004-AQ.action"
2234 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2234 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2235 2235 #
2236 2236 # code: SUN4U-8004-CC
2237 2237 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2238 2238 #
2239 2239 msgid "SUN4U-8004-CC.type"
2240 2240 msgstr "Fault"
2241 2241 msgid "SUN4U-8004-CC.severity"
2242 2242 msgstr "Critical"
2243 2243 msgid "SUN4U-8004-CC.description"
2244 2244 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2245 2245 msgid "SUN4U-8004-CC.response"
2246 2246 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2247 2247 msgid "SUN4U-8004-CC.impact"
2248 2248 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2249 2249 msgid "SUN4U-8004-CC.action"
2250 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2250 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2251 2251 #
2252 2252 # code: SUN4U-8004-DJ
2253 2253 # keys: fault.io.hbus fault.io.schizo fault.io.xmits
2254 2254 #
2255 2255 msgid "SUN4U-8004-DJ.type"
2256 2256 msgstr "Fault"
2257 2257 msgid "SUN4U-8004-DJ.severity"
2258 2258 msgstr "Critical"
2259 2259 msgid "SUN4U-8004-DJ.description"
2260 2260 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2261 2261 msgid "SUN4U-8004-DJ.response"
2262 2262 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2263 2263 msgid "SUN4U-8004-DJ.impact"
2264 2264 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2265 2265 msgid "SUN4U-8004-DJ.action"
2266 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2266 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2267 2267 #
2268 2268 # code: SUN4U-8004-EE
2269 2269 # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits
2270 2270 #
2271 2271 msgid "SUN4U-8004-EE.type"
2272 2272 msgstr "Fault"
2273 2273 msgid "SUN4U-8004-EE.severity"
2274 2274 msgstr "Critical"
2275 2275 msgid "SUN4U-8004-EE.description"
2276 2276 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2277 2277 msgid "SUN4U-8004-EE.response"
2278 2278 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2279 2279 msgid "SUN4U-8004-EE.impact"
2280 2280 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2281 2281 msgid "SUN4U-8004-EE.action"
2282 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2282 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2283 2283 #
2284 2284 # code: SUN4U-8004-FX
2285 2285 # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2286 2286 #
2287 2287 msgid "SUN4U-8004-FX.type"
2288 2288 msgstr "Fault"
2289 2289 msgid "SUN4U-8004-FX.severity"
2290 2290 msgstr "Critical"
2291 2291 msgid "SUN4U-8004-FX.description"
2292 2292 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2293 2293 msgid "SUN4U-8004-FX.response"
2294 2294 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2295 2295 msgid "SUN4U-8004-FX.impact"
2296 2296 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2297 2297 msgid "SUN4U-8004-FX.action"
2298 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2298 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2299 2299 #
2300 2300 # code: SUN4U-8004-G2
2301 2301 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2302 2302 #
2303 2303 msgid "SUN4U-8004-G2.type"
2304 2304 msgstr "Fault"
2305 2305 msgid "SUN4U-8004-G2.severity"
2306 2306 msgstr "Critical"
2307 2307 msgid "SUN4U-8004-G2.description"
2308 2308 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2309 2309 msgid "SUN4U-8004-G2.response"
2310 2310 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2311 2311 msgid "SUN4U-8004-G2.impact"
2312 2312 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2313 2313 msgid "SUN4U-8004-G2.action"
2314 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2314 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2315 2315 #
2316 2316 # code: SUN4U-8004-HS
2317 2317 # keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2318 2318 #
2319 2319 msgid "SUN4U-8004-HS.type"
2320 2320 msgstr "Fault"
2321 2321 msgid "SUN4U-8004-HS.severity"
2322 2322 msgstr "Critical"
2323 2323 msgid "SUN4U-8004-HS.description"
2324 2324 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2325 2325 msgid "SUN4U-8004-HS.response"
2326 2326 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2327 2327 msgid "SUN4U-8004-HS.impact"
2328 2328 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2329 2329 msgid "SUN4U-8004-HS.action"
2330 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2330 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2331 2331 #
2332 2332 # code: SUN4U-8004-J5
2333 2333 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2334 2334 #
2335 2335 msgid "SUN4U-8004-J5.type"
2336 2336 msgstr "Fault"
2337 2337 msgid "SUN4U-8004-J5.severity"
2338 2338 msgstr "Critical"
2339 2339 msgid "SUN4U-8004-J5.description"
2340 2340 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2341 2341 msgid "SUN4U-8004-J5.response"
2342 2342 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2343 2343 msgid "SUN4U-8004-J5.impact"
2344 2344 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2345 2345 msgid "SUN4U-8004-J5.action"
2346 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2346 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2347 2347 #
2348 2348 # code: SUN4U-8004-KP
2349 2349 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2350 2350 #
2351 2351 msgid "SUN4U-8004-KP.type"
2352 2352 msgstr "Fault"
2353 2353 msgid "SUN4U-8004-KP.severity"
2354 2354 msgstr "Critical"
2355 2355 msgid "SUN4U-8004-KP.description"
2356 2356 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2357 2357 msgid "SUN4U-8004-KP.response"
2358 2358 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2359 2359 msgid "SUN4U-8004-KP.impact"
2360 2360 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2361 2361 msgid "SUN4U-8004-KP.action"
2362 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2362 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2363 2363 #
2364 2364 # code: SUN4U-8004-LA
2365 2365 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2366 2366 #
2367 2367 msgid "SUN4U-8004-LA.type"
2368 2368 msgstr "Fault"
2369 2369 msgid "SUN4U-8004-LA.severity"
2370 2370 msgstr "Critical"
2371 2371 msgid "SUN4U-8004-LA.description"
2372 2372 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2373 2373 msgid "SUN4U-8004-LA.response"
2374 2374 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2375 2375 msgid "SUN4U-8004-LA.impact"
2376 2376 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2377 2377 msgid "SUN4U-8004-LA.action"
2378 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2378 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2379 2379 #
2380 2380 # code: SUN4U-8004-MH
2381 2381 # keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2382 2382 #
2383 2383 msgid "SUN4U-8004-MH.type"
2384 2384 msgstr "Fault"
2385 2385 msgid "SUN4U-8004-MH.severity"
2386 2386 msgstr "Critical"
2387 2387 msgid "SUN4U-8004-MH.description"
2388 2388 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2389 2389 msgid "SUN4U-8004-MH.response"
2390 2390 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2391 2391 msgid "SUN4U-8004-MH.impact"
2392 2392 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2393 2393 msgid "SUN4U-8004-MH.action"
2394 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2394 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2395 2395 #
2396 2396 # code: SUN4U-8004-ND
2397 2397 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2398 2398 #
2399 2399 msgid "SUN4U-8004-ND.type"
2400 2400 msgstr "Fault"
2401 2401 msgid "SUN4U-8004-ND.severity"
2402 2402 msgstr "Critical"
2403 2403 msgid "SUN4U-8004-ND.description"
2404 2404 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2405 2405 msgid "SUN4U-8004-ND.response"
2406 2406 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2407 2407 msgid "SUN4U-8004-ND.impact"
2408 2408 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2409 2409 msgid "SUN4U-8004-ND.action"
2410 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2410 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2411 2411 #
2412 2412 # code: SUN4U-8004-PY
2413 2413 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2414 2414 #
2415 2415 msgid "SUN4U-8004-PY.type"
2416 2416 msgstr "Fault"
2417 2417 msgid "SUN4U-8004-PY.severity"
2418 2418 msgstr "Critical"
2419 2419 msgid "SUN4U-8004-PY.description"
2420 2420 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2421 2421 msgid "SUN4U-8004-PY.response"
2422 2422 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2423 2423 msgid "SUN4U-8004-PY.impact"
2424 2424 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2425 2425 msgid "SUN4U-8004-PY.action"
2426 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2426 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2427 2427 #
2428 2428 # code: SUN4U-8004-Q3
2429 2429 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2430 2430 #
2431 2431 msgid "SUN4U-8004-Q3.type"
2432 2432 msgstr "Fault"
2433 2433 msgid "SUN4U-8004-Q3.severity"
2434 2434 msgstr "Critical"
2435 2435 msgid "SUN4U-8004-Q3.description"
2436 2436 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2437 2437 msgid "SUN4U-8004-Q3.response"
2438 2438 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2439 2439 msgid "SUN4U-8004-Q3.impact"
2440 2440 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2441 2441 msgid "SUN4U-8004-Q3.action"
2442 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2442 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2443 2443 #
2444 2444 # code: SUN4U-8004-RC
2445 2445 # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2446 2446 #
2447 2447 msgid "SUN4U-8004-RC.type"
2448 2448 msgstr "Fault"
2449 2449 msgid "SUN4U-8004-RC.severity"
2450 2450 msgstr "Critical"
2451 2451 msgid "SUN4U-8004-RC.description"
2452 2452 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2453 2453 msgid "SUN4U-8004-RC.response"
2454 2454 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2455 2455 msgid "SUN4U-8004-RC.impact"
2456 2456 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2457 2457 msgid "SUN4U-8004-RC.action"
2458 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2458 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2459 2459 #
2460 2460 # code: SUN4U-8004-SQ
2461 2461 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2462 2462 #
2463 2463 msgid "SUN4U-8004-SQ.type"
2464 2464 msgstr "Fault"
2465 2465 msgid "SUN4U-8004-SQ.severity"
2466 2466 msgstr "Critical"
2467 2467 msgid "SUN4U-8004-SQ.description"
2468 2468 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2469 2469 msgid "SUN4U-8004-SQ.response"
2470 2470 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2471 2471 msgid "SUN4U-8004-SQ.impact"
2472 2472 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2473 2473 msgid "SUN4U-8004-SQ.action"
2474 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2474 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2475 2475 #
2476 2476 # code: SUN4U-8004-T4
2477 2477 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2478 2478 #
2479 2479 msgid "SUN4U-8004-T4.type"
2480 2480 msgstr "Fault"
2481 2481 msgid "SUN4U-8004-T4.severity"
2482 2482 msgstr "Critical"
2483 2483 msgid "SUN4U-8004-T4.description"
2484 2484 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2485 2485 msgid "SUN4U-8004-T4.response"
2486 2486 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2487 2487 msgid "SUN4U-8004-T4.impact"
2488 2488 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2489 2489 msgid "SUN4U-8004-T4.action"
2490 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2490 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2491 2491 #
2492 2492 # code: SUN4U-8004-UR
2493 2493 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2494 2494 #
2495 2495 msgid "SUN4U-8004-UR.type"
2496 2496 msgstr "Fault"
2497 2497 msgid "SUN4U-8004-UR.severity"
2498 2498 msgstr "Critical"
2499 2499 msgid "SUN4U-8004-UR.description"
2500 2500 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2501 2501 msgid "SUN4U-8004-UR.response"
2502 2502 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2503 2503 msgid "SUN4U-8004-UR.impact"
2504 2504 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2505 2505 msgid "SUN4U-8004-UR.action"
2506 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2506 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2507 2507 #
2508 2508 # code: SUN4U-8004-V2
2509 2509 # keys: fault.io.psycho
2510 2510 #
2511 2511 msgid "SUN4U-8004-V2.type"
2512 2512 msgstr "Fault"
2513 2513 msgid "SUN4U-8004-V2.severity"
2514 2514 msgstr "Critical"
2515 2515 msgid "SUN4U-8004-V2.description"
2516 2516 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2517 2517 msgid "SUN4U-8004-V2.response"
2518 2518 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2519 2519 msgid "SUN4U-8004-V2.impact"
2520 2520 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2521 2521 msgid "SUN4U-8004-V2.action"
2522 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2522 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2523 2523 #
2524 2524 # code: SUN4U-8004-WX
2525 2525 # keys: defect.io.pci.driver fault.io.psycho
2526 2526 #
2527 2527 msgid "SUN4U-8004-WX.type"
2528 2528 msgstr "Fault"
2529 2529 msgid "SUN4U-8004-WX.severity"
2530 2530 msgstr "Critical"
2531 2531 msgid "SUN4U-8004-WX.description"
2532 2532 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2533 2533 msgid "SUN4U-8004-WX.response"
2534 2534 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2535 2535 msgid "SUN4U-8004-WX.impact"
2536 2536 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2537 2537 msgid "SUN4U-8004-WX.action"
2538 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2538 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2539 2539 #
2540 2540 # code: SUN4U-8004-XE
2541 2541 # keys: fault.io.datapath fault.io.psycho
2542 2542 #
2543 2543 msgid "SUN4U-8004-XE.type"
2544 2544 msgstr "Fault"
2545 2545 msgid "SUN4U-8004-XE.severity"
2546 2546 msgstr "Critical"
2547 2547 msgid "SUN4U-8004-XE.description"
2548 2548 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2549 2549 msgid "SUN4U-8004-XE.response"
2550 2550 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2551 2551 msgid "SUN4U-8004-XE.impact"
2552 2552 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2553 2553 msgid "SUN4U-8004-XE.action"
2554 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2554 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2555 2555 #
2556 2556 # code: SUN4U-8004-YJ
2557 2557 # keys: defect.io.pci.driver fault.io.datapath fault.io.psycho
2558 2558 #
2559 2559 msgid "SUN4U-8004-YJ.type"
2560 2560 msgstr "Fault"
2561 2561 msgid "SUN4U-8004-YJ.severity"
2562 2562 msgstr "Critical"
2563 2563 msgid "SUN4U-8004-YJ.description"
2564 2564 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2565 2565 msgid "SUN4U-8004-YJ.response"
2566 2566 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2567 2567 msgid "SUN4U-8004-YJ.impact"
2568 2568 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2569 2569 msgid "SUN4U-8004-YJ.action"
2570 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2570 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2571 2571 #
2572 2572 # code: SUN4U-8005-0E
2573 2573 # keys: fault.io.hbus fault.io.psycho
2574 2574 #
2575 2575 msgid "SUN4U-8005-0E.type"
2576 2576 msgstr "Fault"
2577 2577 msgid "SUN4U-8005-0E.severity"
2578 2578 msgstr "Critical"
2579 2579 msgid "SUN4U-8005-0E.description"
2580 2580 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2581 2581 msgid "SUN4U-8005-0E.response"
2582 2582 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2583 2583 msgid "SUN4U-8005-0E.impact"
2584 2584 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2585 2585 msgid "SUN4U-8005-0E.action"
2586 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2586 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2587 2587 #
2588 2588 # code: SUN4U-8005-1J
2589 2589 # keys: defect.io.pci.driver fault.io.hbus fault.io.psycho
2590 2590 #
2591 2591 msgid "SUN4U-8005-1J.type"
2592 2592 msgstr "Fault"
2593 2593 msgid "SUN4U-8005-1J.severity"
2594 2594 msgstr "Critical"
2595 2595 msgid "SUN4U-8005-1J.description"
2596 2596 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2597 2597 msgid "SUN4U-8005-1J.response"
2598 2598 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2599 2599 msgid "SUN4U-8005-1J.impact"
2600 2600 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2601 2601 msgid "SUN4U-8005-1J.action"
2602 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2602 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2603 2603 #
2604 2604 # code: SUN4U-8005-22
2605 2605 # keys: fault.io.datapath fault.io.hbus fault.io.psycho
2606 2606 #
2607 2607 msgid "SUN4U-8005-22.type"
2608 2608 msgstr "Fault"
2609 2609 msgid "SUN4U-8005-22.severity"
2610 2610 msgstr "Critical"
2611 2611 msgid "SUN4U-8005-22.description"
2612 2612 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2613 2613 msgid "SUN4U-8005-22.response"
2614 2614 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2615 2615 msgid "SUN4U-8005-22.impact"
2616 2616 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2617 2617 msgid "SUN4U-8005-22.action"
2618 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2618 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2619 2619 #
2620 2620 # code: SUN4U-8005-3X
2621 2621 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho
2622 2622 #
2623 2623 msgid "SUN4U-8005-3X.type"
2624 2624 msgstr "Fault"
2625 2625 msgid "SUN4U-8005-3X.severity"
2626 2626 msgstr "Critical"
2627 2627 msgid "SUN4U-8005-3X.description"
2628 2628 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2629 2629 msgid "SUN4U-8005-3X.response"
2630 2630 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2631 2631 msgid "SUN4U-8005-3X.impact"
2632 2632 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2633 2633 msgid "SUN4U-8005-3X.action"
2634 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2634 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2635 2635 #
2636 2636 # code: SUN4U-8005-44
2637 2637 # keys: fault.io.pci.bus fault.io.psycho
2638 2638 #
2639 2639 msgid "SUN4U-8005-44.type"
2640 2640 msgstr "Fault"
2641 2641 msgid "SUN4U-8005-44.severity"
2642 2642 msgstr "Critical"
2643 2643 msgid "SUN4U-8005-44.description"
2644 2644 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2645 2645 msgid "SUN4U-8005-44.response"
2646 2646 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2647 2647 msgid "SUN4U-8005-44.impact"
2648 2648 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2649 2649 msgid "SUN4U-8005-44.action"
2650 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2650 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2651 2651 #
2652 2652 # code: SUN4U-8005-5R
2653 2653 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho
2654 2654 #
2655 2655 msgid "SUN4U-8005-5R.type"
2656 2656 msgstr "Fault"
2657 2657 msgid "SUN4U-8005-5R.severity"
2658 2658 msgstr "Critical"
2659 2659 msgid "SUN4U-8005-5R.description"
2660 2660 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2661 2661 msgid "SUN4U-8005-5R.response"
2662 2662 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2663 2663 msgid "SUN4U-8005-5R.impact"
2664 2664 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2665 2665 msgid "SUN4U-8005-5R.action"
2666 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2666 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2667 2667 #
2668 2668 # code: SUN4U-8005-6C
2669 2669 # keys: fault.io.datapath fault.io.pci.bus fault.io.psycho
2670 2670 #
2671 2671 msgid "SUN4U-8005-6C.type"
2672 2672 msgstr "Fault"
2673 2673 msgid "SUN4U-8005-6C.severity"
2674 2674 msgstr "Critical"
2675 2675 msgid "SUN4U-8005-6C.description"
2676 2676 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2677 2677 msgid "SUN4U-8005-6C.response"
2678 2678 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2679 2679 msgid "SUN4U-8005-6C.impact"
2680 2680 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2681 2681 msgid "SUN4U-8005-6C.action"
2682 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2682 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2683 2683 #
2684 2684 # code: SUN4U-8005-7Q
2685 2685 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho
2686 2686 #
2687 2687 msgid "SUN4U-8005-7Q.type"
2688 2688 msgstr "Fault"
2689 2689 msgid "SUN4U-8005-7Q.severity"
2690 2690 msgstr "Critical"
2691 2691 msgid "SUN4U-8005-7Q.description"
2692 2692 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2693 2693 msgid "SUN4U-8005-7Q.response"
2694 2694 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2695 2695 msgid "SUN4U-8005-7Q.impact"
2696 2696 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2697 2697 msgid "SUN4U-8005-7Q.action"
2698 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2698 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2699 2699 #
2700 2700 # code: SUN4U-8005-8Y
2701 2701 # keys: fault.io.hbus fault.io.pci.bus fault.io.psycho
2702 2702 #
2703 2703 msgid "SUN4U-8005-8Y.type"
2704 2704 msgstr "Fault"
2705 2705 msgid "SUN4U-8005-8Y.severity"
2706 2706 msgstr "Critical"
2707 2707 msgid "SUN4U-8005-8Y.description"
2708 2708 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2709 2709 msgid "SUN4U-8005-8Y.response"
2710 2710 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2711 2711 msgid "SUN4U-8005-8Y.impact"
2712 2712 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2713 2713 msgid "SUN4U-8005-8Y.action"
2714 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2714 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2715 2715 #
2716 2716 # code: SUN4U-8005-93
2717 2717 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho
2718 2718 #
2719 2719 msgid "SUN4U-8005-93.type"
2720 2720 msgstr "Fault"
2721 2721 msgid "SUN4U-8005-93.severity"
2722 2722 msgstr "Critical"
2723 2723 msgid "SUN4U-8005-93.description"
2724 2724 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2725 2725 msgid "SUN4U-8005-93.response"
2726 2726 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2727 2727 msgid "SUN4U-8005-93.impact"
2728 2728 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2729 2729 msgid "SUN4U-8005-93.action"
2730 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2730 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2731 2731 #
2732 2732 # code: SUN4U-8005-AH
2733 2733 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2734 2734 #
2735 2735 msgid "SUN4U-8005-AH.type"
2736 2736 msgstr "Fault"
2737 2737 msgid "SUN4U-8005-AH.severity"
2738 2738 msgstr "Critical"
2739 2739 msgid "SUN4U-8005-AH.description"
2740 2740 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2741 2741 msgid "SUN4U-8005-AH.response"
2742 2742 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2743 2743 msgid "SUN4U-8005-AH.impact"
2744 2744 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2745 2745 msgid "SUN4U-8005-AH.action"
2746 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2746 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2747 2747 #
2748 2748 # code: SUN4U-8005-CD
2749 2749 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2750 2750 #
2751 2751 msgid "SUN4U-8005-CD.type"
2752 2752 msgstr "Fault"
2753 2753 msgid "SUN4U-8005-CD.severity"
2754 2754 msgstr "Critical"
2755 2755 msgid "SUN4U-8005-CD.description"
2756 2756 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2757 2757 msgid "SUN4U-8005-CD.response"
2758 2758 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2759 2759 msgid "SUN4U-8005-CD.impact"
2760 2760 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2761 2761 msgid "SUN4U-8005-CD.action"
2762 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2762 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2763 2763 #
2764 2764 # code: SUN4U-8005-DP
2765 2765 # keys: fault.io.pci.device fault.io.psycho
2766 2766 #
2767 2767 msgid "SUN4U-8005-DP.type"
2768 2768 msgstr "Fault"
2769 2769 msgid "SUN4U-8005-DP.severity"
2770 2770 msgstr "Critical"
2771 2771 msgid "SUN4U-8005-DP.description"
2772 2772 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2773 2773 msgid "SUN4U-8005-DP.response"
2774 2774 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2775 2775 msgid "SUN4U-8005-DP.impact"
2776 2776 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2777 2777 msgid "SUN4U-8005-DP.action"
2778 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2778 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2779 2779 #
2780 2780 # code: SUN4U-8005-EA
2781 2781 # keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho
2782 2782 #
2783 2783 msgid "SUN4U-8005-EA.type"
2784 2784 msgstr "Fault"
2785 2785 msgid "SUN4U-8005-EA.severity"
2786 2786 msgstr "Critical"
2787 2787 msgid "SUN4U-8005-EA.description"
2788 2788 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2789 2789 msgid "SUN4U-8005-EA.response"
2790 2790 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2791 2791 msgid "SUN4U-8005-EA.impact"
2792 2792 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2793 2793 msgid "SUN4U-8005-EA.action"
2794 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2794 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2795 2795 #
2796 2796 # code: SUN4U-8005-FS
2797 2797 # keys: fault.io.datapath fault.io.pci.device fault.io.psycho
2798 2798 #
2799 2799 msgid "SUN4U-8005-FS.type"
2800 2800 msgstr "Fault"
2801 2801 msgid "SUN4U-8005-FS.severity"
2802 2802 msgstr "Critical"
2803 2803 msgid "SUN4U-8005-FS.description"
2804 2804 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2805 2805 msgid "SUN4U-8005-FS.response"
2806 2806 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2807 2807 msgid "SUN4U-8005-FS.impact"
2808 2808 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2809 2809 msgid "SUN4U-8005-FS.action"
2810 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2810 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2811 2811 #
2812 2812 # code: SUN4U-8005-G5
2813 2813 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho
2814 2814 #
2815 2815 msgid "SUN4U-8005-G5.type"
2816 2816 msgstr "Fault"
2817 2817 msgid "SUN4U-8005-G5.severity"
2818 2818 msgstr "Critical"
2819 2819 msgid "SUN4U-8005-G5.description"
2820 2820 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2821 2821 msgid "SUN4U-8005-G5.response"
2822 2822 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2823 2823 msgid "SUN4U-8005-G5.impact"
2824 2824 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2825 2825 msgid "SUN4U-8005-G5.action"
2826 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2826 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2827 2827 #
2828 2828 # code: SUN4U-8005-HX
2829 2829 # keys: fault.io.hbus fault.io.pci.device fault.io.psycho
2830 2830 #
2831 2831 msgid "SUN4U-8005-HX.type"
2832 2832 msgstr "Fault"
2833 2833 msgid "SUN4U-8005-HX.severity"
2834 2834 msgstr "Critical"
2835 2835 msgid "SUN4U-8005-HX.description"
2836 2836 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2837 2837 msgid "SUN4U-8005-HX.response"
2838 2838 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2839 2839 msgid "SUN4U-8005-HX.impact"
2840 2840 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2841 2841 msgid "SUN4U-8005-HX.action"
2842 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2842 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2843 2843 #
2844 2844 # code: SUN4U-8005-J2
2845 2845 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho
2846 2846 #
2847 2847 msgid "SUN4U-8005-J2.type"
2848 2848 msgstr "Fault"
2849 2849 msgid "SUN4U-8005-J2.severity"
2850 2850 msgstr "Critical"
2851 2851 msgid "SUN4U-8005-J2.description"
2852 2852 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2853 2853 msgid "SUN4U-8005-J2.response"
2854 2854 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2855 2855 msgid "SUN4U-8005-J2.impact"
2856 2856 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2857 2857 msgid "SUN4U-8005-J2.action"
2858 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2858 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2859 2859 #
2860 2860 # code: SUN4U-8005-KJ
2861 2861 # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2862 2862 #
2863 2863 msgid "SUN4U-8005-KJ.type"
2864 2864 msgstr "Fault"
2865 2865 msgid "SUN4U-8005-KJ.severity"
2866 2866 msgstr "Critical"
2867 2867 msgid "SUN4U-8005-KJ.description"
2868 2868 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2869 2869 msgid "SUN4U-8005-KJ.response"
2870 2870 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2871 2871 msgid "SUN4U-8005-KJ.impact"
2872 2872 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2873 2873 msgid "SUN4U-8005-KJ.action"
2874 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2874 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2875 2875 #
2876 2876 # code: SUN4U-8005-LE
2877 2877 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2878 2878 #
2879 2879 msgid "SUN4U-8005-LE.type"
2880 2880 msgstr "Fault"
2881 2881 msgid "SUN4U-8005-LE.severity"
2882 2882 msgstr "Critical"
2883 2883 msgid "SUN4U-8005-LE.description"
2884 2884 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2885 2885 msgid "SUN4U-8005-LE.response"
2886 2886 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2887 2887 msgid "SUN4U-8005-LE.impact"
2888 2888 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2889 2889 msgid "SUN4U-8005-LE.action"
2890 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2890 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2891 2891 #
2892 2892 # code: SUN4U-8005-MQ
2893 2893 # keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho
2894 2894 #
2895 2895 msgid "SUN4U-8005-MQ.type"
2896 2896 msgstr "Fault"
2897 2897 msgid "SUN4U-8005-MQ.severity"
2898 2898 msgstr "Critical"
2899 2899 msgid "SUN4U-8005-MQ.description"
2900 2900 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2901 2901 msgid "SUN4U-8005-MQ.response"
2902 2902 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2903 2903 msgid "SUN4U-8005-MQ.impact"
2904 2904 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2905 2905 msgid "SUN4U-8005-MQ.action"
2906 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2906 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2907 2907 #
2908 2908 # code: SUN4U-8005-NC
2909 2909 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho
2910 2910 #
2911 2911 msgid "SUN4U-8005-NC.type"
2912 2912 msgstr "Fault"
2913 2913 msgid "SUN4U-8005-NC.severity"
2914 2914 msgstr "Critical"
2915 2915 msgid "SUN4U-8005-NC.description"
2916 2916 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2917 2917 msgid "SUN4U-8005-NC.response"
2918 2918 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2919 2919 msgid "SUN4U-8005-NC.impact"
2920 2920 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2921 2921 msgid "SUN4U-8005-NC.action"
2922 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2922 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2923 2923 #
2924 2924 # code: SUN4U-8005-PR
2925 2925 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2926 2926 #
2927 2927 msgid "SUN4U-8005-PR.type"
2928 2928 msgstr "Fault"
2929 2929 msgid "SUN4U-8005-PR.severity"
2930 2930 msgstr "Critical"
2931 2931 msgid "SUN4U-8005-PR.description"
2932 2932 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2933 2933 msgid "SUN4U-8005-PR.response"
2934 2934 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2935 2935 msgid "SUN4U-8005-PR.impact"
2936 2936 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2937 2937 msgid "SUN4U-8005-PR.action"
2938 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2938 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2939 2939 #
2940 2940 # code: SUN4U-8005-Q4
2941 2941 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2942 2942 #
2943 2943 msgid "SUN4U-8005-Q4.type"
2944 2944 msgstr "Fault"
2945 2945 msgid "SUN4U-8005-Q4.severity"
2946 2946 msgstr "Critical"
2947 2947 msgid "SUN4U-8005-Q4.description"
2948 2948 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2949 2949 msgid "SUN4U-8005-Q4.response"
2950 2950 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2951 2951 msgid "SUN4U-8005-Q4.impact"
2952 2952 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2953 2953 msgid "SUN4U-8005-Q4.action"
2954 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2954 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2955 2955 #
2956 2956 # code: SUN4U-8005-RD
2957 2957 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2958 2958 #
2959 2959 msgid "SUN4U-8005-RD.type"
2960 2960 msgstr "Fault"
2961 2961 msgid "SUN4U-8005-RD.severity"
2962 2962 msgstr "Critical"
2963 2963 msgid "SUN4U-8005-RD.description"
2964 2964 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2965 2965 msgid "SUN4U-8005-RD.response"
2966 2966 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2967 2967 msgid "SUN4U-8005-RD.impact"
2968 2968 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2969 2969 msgid "SUN4U-8005-RD.action"
2970 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2970 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
2971 2971 #
2972 2972 # code: SUN4U-8005-SH
2973 2973 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2974 2974 #
2975 2975 msgid "SUN4U-8005-SH.type"
2976 2976 msgstr "Fault"
2977 2977 msgid "SUN4U-8005-SH.severity"
2978 2978 msgstr "Critical"
2979 2979 msgid "SUN4U-8005-SH.description"
2980 2980 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
2981 2981 msgid "SUN4U-8005-SH.response"
2982 2982 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2983 2983 msgid "SUN4U-8005-SH.impact"
2984 2984 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2985 2985 msgid "SUN4U-8005-SH.action"
2986 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2986 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
2987 2987 #
2988 2988 # code: SUN4U-8005-T3
2989 2989 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2990 2990 #
2991 2991 msgid "SUN4U-8005-T3.type"
2992 2992 msgstr "Fault"
2993 2993 msgid "SUN4U-8005-T3.severity"
2994 2994 msgstr "Critical"
2995 2995 msgid "SUN4U-8005-T3.description"
2996 2996 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
2997 2997 msgid "SUN4U-8005-T3.response"
2998 2998 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2999 2999 msgid "SUN4U-8005-T3.impact"
3000 3000 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3001 3001 msgid "SUN4U-8005-T3.action"
3002 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3002 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3003 3003 #
3004 3004 # code: SUN4U-8005-UY
3005 3005 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
3006 3006 #
3007 3007 msgid "SUN4U-8005-UY.type"
3008 3008 msgstr "Fault"
3009 3009 msgid "SUN4U-8005-UY.severity"
3010 3010 msgstr "Critical"
3011 3011 msgid "SUN4U-8005-UY.description"
3012 3012 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3013 3013 msgid "SUN4U-8005-UY.response"
3014 3014 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3015 3015 msgid "SUN4U-8005-UY.impact"
3016 3016 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3017 3017 msgid "SUN4U-8005-UY.action"
3018 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3018 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3019 3019 #
3020 3020 # code: SUN4U-8005-V5
3021 3021 # keys: fault.io.tomatillo
3022 3022 #
3023 3023 msgid "SUN4U-8005-V5.type"
3024 3024 msgstr "Fault"
3025 3025 msgid "SUN4U-8005-V5.severity"
3026 3026 msgstr "Critical"
3027 3027 msgid "SUN4U-8005-V5.description"
3028 3028 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3029 3029 msgid "SUN4U-8005-V5.response"
3030 3030 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3031 3031 msgid "SUN4U-8005-V5.impact"
3032 3032 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3033 3033 msgid "SUN4U-8005-V5.action"
3034 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3034 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3035 3035 #
3036 3036 # code: SUN4U-8005-WS
3037 3037 # keys: defect.io.pci.driver fault.io.tomatillo
3038 3038 #
3039 3039 msgid "SUN4U-8005-WS.type"
3040 3040 msgstr "Fault"
3041 3041 msgid "SUN4U-8005-WS.severity"
3042 3042 msgstr "Critical"
3043 3043 msgid "SUN4U-8005-WS.description"
3044 3044 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3045 3045 msgid "SUN4U-8005-WS.response"
3046 3046 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3047 3047 msgid "SUN4U-8005-WS.impact"
3048 3048 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3049 3049 msgid "SUN4U-8005-WS.action"
3050 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3050 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3051 3051 #
3052 3052 # code: SUN4U-8005-XA
3053 3053 # keys: fault.io.datapath fault.io.tomatillo
3054 3054 #
3055 3055 msgid "SUN4U-8005-XA.type"
3056 3056 msgstr "Fault"
3057 3057 msgid "SUN4U-8005-XA.severity"
3058 3058 msgstr "Critical"
3059 3059 msgid "SUN4U-8005-XA.description"
3060 3060 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3061 3061 msgid "SUN4U-8005-XA.response"
3062 3062 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3063 3063 msgid "SUN4U-8005-XA.impact"
3064 3064 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3065 3065 msgid "SUN4U-8005-XA.action"
3066 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3066 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3067 3067 #
3068 3068 # code: SUN4U-8005-YP
3069 3069 # keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo
3070 3070 #
3071 3071 msgid "SUN4U-8005-YP.type"
3072 3072 msgstr "Fault"
3073 3073 msgid "SUN4U-8005-YP.severity"
3074 3074 msgstr "Critical"
3075 3075 msgid "SUN4U-8005-YP.description"
3076 3076 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3077 3077 msgid "SUN4U-8005-YP.response"
3078 3078 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3079 3079 msgid "SUN4U-8005-YP.impact"
3080 3080 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3081 3081 msgid "SUN4U-8005-YP.action"
3082 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3082 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3083 3083 #
3084 3084 # code: SUN4U-8006-04
3085 3085 # keys: fault.io.hbus fault.io.tomatillo
3086 3086 #
3087 3087 msgid "SUN4U-8006-04.type"
3088 3088 msgstr "Fault"
3089 3089 msgid "SUN4U-8006-04.severity"
3090 3090 msgstr "Critical"
3091 3091 msgid "SUN4U-8006-04.description"
3092 3092 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3093 3093 msgid "SUN4U-8006-04.response"
3094 3094 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3095 3095 msgid "SUN4U-8006-04.impact"
3096 3096 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3097 3097 msgid "SUN4U-8006-04.action"
3098 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3098 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3099 3099 #
3100 3100 # code: SUN4U-8006-1R
3101 3101 # keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo
3102 3102 #
3103 3103 msgid "SUN4U-8006-1R.type"
3104 3104 msgstr "Fault"
3105 3105 msgid "SUN4U-8006-1R.severity"
3106 3106 msgstr "Critical"
3107 3107 msgid "SUN4U-8006-1R.description"
3108 3108 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3109 3109 msgid "SUN4U-8006-1R.response"
3110 3110 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3111 3111 msgid "SUN4U-8006-1R.impact"
3112 3112 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3113 3113 msgid "SUN4U-8006-1R.action"
3114 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3114 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3115 3115 #
3116 3116 # code: SUN4U-8006-2C
3117 3117 # keys: fault.io.datapath fault.io.hbus fault.io.tomatillo
3118 3118 #
3119 3119 msgid "SUN4U-8006-2C.type"
3120 3120 msgstr "Fault"
3121 3121 msgid "SUN4U-8006-2C.severity"
3122 3122 msgstr "Critical"
3123 3123 msgid "SUN4U-8006-2C.description"
3124 3124 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3125 3125 msgid "SUN4U-8006-2C.response"
3126 3126 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3127 3127 msgid "SUN4U-8006-2C.impact"
3128 3128 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3129 3129 msgid "SUN4U-8006-2C.action"
3130 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3130 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3131 3131 #
3132 3132 # code: SUN4U-8006-3Q
3133 3133 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo
3134 3134 #
3135 3135 msgid "SUN4U-8006-3Q.type"
3136 3136 msgstr "Fault"
3137 3137 msgid "SUN4U-8006-3Q.severity"
3138 3138 msgstr "Critical"
3139 3139 msgid "SUN4U-8006-3Q.description"
3140 3140 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3141 3141 msgid "SUN4U-8006-3Q.response"
3142 3142 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3143 3143 msgid "SUN4U-8006-3Q.impact"
3144 3144 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3145 3145 msgid "SUN4U-8006-3Q.action"
3146 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3146 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3147 3147 #
3148 3148 # code: SUN4U-8006-4E
3149 3149 # keys: fault.io.pci.bus fault.io.tomatillo
3150 3150 #
3151 3151 msgid "SUN4U-8006-4E.type"
3152 3152 msgstr "Fault"
3153 3153 msgid "SUN4U-8006-4E.severity"
3154 3154 msgstr "Critical"
3155 3155 msgid "SUN4U-8006-4E.description"
3156 3156 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3157 3157 msgid "SUN4U-8006-4E.response"
3158 3158 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3159 3159 msgid "SUN4U-8006-4E.impact"
3160 3160 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3161 3161 msgid "SUN4U-8006-4E.action"
3162 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3162 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3163 3163 #
3164 3164 # code: SUN4U-8006-5J
3165 3165 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo
3166 3166 #
3167 3167 msgid "SUN4U-8006-5J.type"
3168 3168 msgstr "Fault"
3169 3169 msgid "SUN4U-8006-5J.severity"
3170 3170 msgstr "Critical"
3171 3171 msgid "SUN4U-8006-5J.description"
3172 3172 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3173 3173 msgid "SUN4U-8006-5J.response"
3174 3174 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3175 3175 msgid "SUN4U-8006-5J.impact"
3176 3176 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3177 3177 msgid "SUN4U-8006-5J.action"
3178 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3178 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3179 3179 #
3180 3180 # code: SUN4U-8006-62
3181 3181 # keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3182 3182 #
3183 3183 msgid "SUN4U-8006-62.type"
3184 3184 msgstr "Fault"
3185 3185 msgid "SUN4U-8006-62.severity"
3186 3186 msgstr "Critical"
3187 3187 msgid "SUN4U-8006-62.description"
3188 3188 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3189 3189 msgid "SUN4U-8006-62.response"
3190 3190 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3191 3191 msgid "SUN4U-8006-62.impact"
3192 3192 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3193 3193 msgid "SUN4U-8006-62.action"
3194 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3194 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3195 3195 #
3196 3196 # code: SUN4U-8006-7X
3197 3197 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3198 3198 #
3199 3199 msgid "SUN4U-8006-7X.type"
3200 3200 msgstr "Fault"
3201 3201 msgid "SUN4U-8006-7X.severity"
3202 3202 msgstr "Critical"
3203 3203 msgid "SUN4U-8006-7X.description"
3204 3204 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3205 3205 msgid "SUN4U-8006-7X.response"
3206 3206 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3207 3207 msgid "SUN4U-8006-7X.impact"
3208 3208 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3209 3209 msgid "SUN4U-8006-7X.action"
3210 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3210 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3211 3211 #
3212 3212 # code: SUN4U-8006-8P
3213 3213 # keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3214 3214 #
3215 3215 msgid "SUN4U-8006-8P.type"
3216 3216 msgstr "Fault"
3217 3217 msgid "SUN4U-8006-8P.severity"
3218 3218 msgstr "Critical"
3219 3219 msgid "SUN4U-8006-8P.description"
3220 3220 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3221 3221 msgid "SUN4U-8006-8P.response"
3222 3222 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3223 3223 msgid "SUN4U-8006-8P.impact"
3224 3224 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3225 3225 msgid "SUN4U-8006-8P.action"
3226 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3226 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3227 3227 #
3228 3228 # code: SUN4U-8006-9A
3229 3229 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3230 3230 #
3231 3231 msgid "SUN4U-8006-9A.type"
3232 3232 msgstr "Fault"
3233 3233 msgid "SUN4U-8006-9A.severity"
3234 3234 msgstr "Critical"
3235 3235 msgid "SUN4U-8006-9A.description"
3236 3236 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3237 3237 msgid "SUN4U-8006-9A.response"
3238 3238 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3239 3239 msgid "SUN4U-8006-9A.impact"
3240 3240 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3241 3241 msgid "SUN4U-8006-9A.action"
3242 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3242 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3243 3243 #
3244 3244 # code: SUN4U-8006-AS
3245 3245 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3246 3246 #
3247 3247 msgid "SUN4U-8006-AS.type"
3248 3248 msgstr "Fault"
3249 3249 msgid "SUN4U-8006-AS.severity"
3250 3250 msgstr "Critical"
3251 3251 msgid "SUN4U-8006-AS.description"
3252 3252 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3253 3253 msgid "SUN4U-8006-AS.response"
3254 3254 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3255 3255 msgid "SUN4U-8006-AS.impact"
3256 3256 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3257 3257 msgid "SUN4U-8006-AS.action"
3258 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3258 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3259 3259 #
3260 3260 # code: SUN4U-8006-C5
3261 3261 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3262 3262 #
3263 3263 msgid "SUN4U-8006-C5.type"
3264 3264 msgstr "Fault"
3265 3265 msgid "SUN4U-8006-C5.severity"
3266 3266 msgstr "Critical"
3267 3267 msgid "SUN4U-8006-C5.description"
3268 3268 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3269 3269 msgid "SUN4U-8006-C5.response"
3270 3270 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3271 3271 msgid "SUN4U-8006-C5.impact"
3272 3272 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3273 3273 msgid "SUN4U-8006-C5.action"
3274 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3274 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3275 3275 #
3276 3276 # code: SUN4U-8006-DY
3277 3277 # keys: fault.io.pci.device fault.io.tomatillo
3278 3278 #
3279 3279 msgid "SUN4U-8006-DY.type"
3280 3280 msgstr "Fault"
3281 3281 msgid "SUN4U-8006-DY.severity"
3282 3282 msgstr "Critical"
3283 3283 msgid "SUN4U-8006-DY.description"
3284 3284 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3285 3285 msgid "SUN4U-8006-DY.response"
3286 3286 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3287 3287 msgid "SUN4U-8006-DY.impact"
3288 3288 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3289 3289 msgid "SUN4U-8006-DY.action"
3290 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3290 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3291 3291 #
3292 3292 # code: SUN4U-8006-E3
3293 3293 # keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo
3294 3294 #
3295 3295 msgid "SUN4U-8006-E3.type"
3296 3296 msgstr "Fault"
3297 3297 msgid "SUN4U-8006-E3.severity"
3298 3298 msgstr "Critical"
3299 3299 msgid "SUN4U-8006-E3.description"
3300 3300 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3301 3301 msgid "SUN4U-8006-E3.response"
3302 3302 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3303 3303 msgid "SUN4U-8006-E3.impact"
3304 3304 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3305 3305 msgid "SUN4U-8006-E3.action"
3306 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3306 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3307 3307 #
3308 3308 # code: SUN4U-8006-FH
3309 3309 # keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo
3310 3310 #
3311 3311 msgid "SUN4U-8006-FH.type"
3312 3312 msgstr "Fault"
3313 3313 msgid "SUN4U-8006-FH.severity"
3314 3314 msgstr "Critical"
3315 3315 msgid "SUN4U-8006-FH.description"
3316 3316 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3317 3317 msgid "SUN4U-8006-FH.response"
3318 3318 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3319 3319 msgid "SUN4U-8006-FH.impact"
3320 3320 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3321 3321 msgid "SUN4U-8006-FH.action"
3322 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3322 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3323 3323 #
3324 3324 # code: SUN4U-8006-GD
3325 3325 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo
3326 3326 #
3327 3327 msgid "SUN4U-8006-GD.type"
3328 3328 msgstr "Fault"
3329 3329 msgid "SUN4U-8006-GD.severity"
3330 3330 msgstr "Critical"
3331 3331 msgid "SUN4U-8006-GD.description"
3332 3332 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3333 3333 msgid "SUN4U-8006-GD.response"
3334 3334 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3335 3335 msgid "SUN4U-8006-GD.impact"
3336 3336 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3337 3337 msgid "SUN4U-8006-GD.action"
3338 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3338 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3339 3339 #
3340 3340 # code: SUN4U-8006-HQ
3341 3341 # keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo
3342 3342 #
3343 3343 msgid "SUN4U-8006-HQ.type"
3344 3344 msgstr "Fault"
3345 3345 msgid "SUN4U-8006-HQ.severity"
3346 3346 msgstr "Critical"
3347 3347 msgid "SUN4U-8006-HQ.description"
3348 3348 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3349 3349 msgid "SUN4U-8006-HQ.response"
3350 3350 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3351 3351 msgid "SUN4U-8006-HQ.impact"
3352 3352 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3353 3353 msgid "SUN4U-8006-HQ.action"
3354 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3354 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3355 3355 #
3356 3356 # code: SUN4U-8006-JC
3357 3357 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo
3358 3358 #
3359 3359 msgid "SUN4U-8006-JC.type"
3360 3360 msgstr "Fault"
3361 3361 msgid "SUN4U-8006-JC.severity"
3362 3362 msgstr "Critical"
3363 3363 msgid "SUN4U-8006-JC.description"
3364 3364 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3365 3365 msgid "SUN4U-8006-JC.response"
3366 3366 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3367 3367 msgid "SUN4U-8006-JC.impact"
3368 3368 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3369 3369 msgid "SUN4U-8006-JC.action"
3370 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3370 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3371 3371 #
3372 3372 # code: SUN4U-8006-KR
3373 3373 # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3374 3374 #
3375 3375 msgid "SUN4U-8006-KR.type"
3376 3376 msgstr "Fault"
3377 3377 msgid "SUN4U-8006-KR.severity"
3378 3378 msgstr "Critical"
3379 3379 msgid "SUN4U-8006-KR.description"
3380 3380 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3381 3381 msgid "SUN4U-8006-KR.response"
3382 3382 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3383 3383 msgid "SUN4U-8006-KR.impact"
3384 3384 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3385 3385 msgid "SUN4U-8006-KR.action"
3386 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3386 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3387 3387 #
3388 3388 # code: SUN4U-8006-L4
3389 3389 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3390 3390 #
3391 3391 msgid "SUN4U-8006-L4.type"
3392 3392 msgstr "Fault"
3393 3393 msgid "SUN4U-8006-L4.severity"
3394 3394 msgstr "Critical"
3395 3395 msgid "SUN4U-8006-L4.description"
3396 3396 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3397 3397 msgid "SUN4U-8006-L4.response"
3398 3398 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3399 3399 msgid "SUN4U-8006-L4.impact"
3400 3400 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3401 3401 msgid "SUN4U-8006-L4.action"
3402 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3402 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3403 3403 #
3404 3404 # code: SUN4U-8006-MX
3405 3405 # keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3406 3406 #
3407 3407 msgid "SUN4U-8006-MX.type"
3408 3408 msgstr "Fault"
3409 3409 msgid "SUN4U-8006-MX.severity"
3410 3410 msgstr "Critical"
3411 3411 msgid "SUN4U-8006-MX.description"
3412 3412 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3413 3413 msgid "SUN4U-8006-MX.response"
3414 3414 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3415 3415 msgid "SUN4U-8006-MX.impact"
3416 3416 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3417 3417 msgid "SUN4U-8006-MX.action"
3418 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3418 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3419 3419 #
3420 3420 # code: SUN4U-8006-N2
3421 3421 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3422 3422 #
3423 3423 msgid "SUN4U-8006-N2.type"
3424 3424 msgstr "Fault"
3425 3425 msgid "SUN4U-8006-N2.severity"
3426 3426 msgstr "Critical"
3427 3427 msgid "SUN4U-8006-N2.description"
3428 3428 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3429 3429 msgid "SUN4U-8006-N2.response"
3430 3430 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3431 3431 msgid "SUN4U-8006-N2.impact"
3432 3432 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3433 3433 msgid "SUN4U-8006-N2.action"
3434 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3434 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3435 3435 #
3436 3436 # code: SUN4U-8006-PJ
3437 3437 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3438 3438 #
3439 3439 msgid "SUN4U-8006-PJ.type"
3440 3440 msgstr "Fault"
3441 3441 msgid "SUN4U-8006-PJ.severity"
3442 3442 msgstr "Critical"
3443 3443 msgid "SUN4U-8006-PJ.description"
3444 3444 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3445 3445 msgid "SUN4U-8006-PJ.response"
3446 3446 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3447 3447 msgid "SUN4U-8006-PJ.impact"
3448 3448 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3449 3449 msgid "SUN4U-8006-PJ.action"
3450 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3450 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3451 3451 #
3452 3452 # code: SUN4U-8006-QE
3453 3453 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3454 3454 #
3455 3455 msgid "SUN4U-8006-QE.type"
3456 3456 msgstr "Fault"
3457 3457 msgid "SUN4U-8006-QE.severity"
3458 3458 msgstr "Critical"
3459 3459 msgid "SUN4U-8006-QE.description"
3460 3460 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3461 3461 msgid "SUN4U-8006-QE.response"
3462 3462 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3463 3463 msgid "SUN4U-8006-QE.impact"
3464 3464 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3465 3465 msgid "SUN4U-8006-QE.action"
3466 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3466 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3467 3467 #
3468 3468 # code: SUN4U-8006-R5
3469 3469 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3470 3470 #
3471 3471 msgid "SUN4U-8006-R5.type"
3472 3472 msgstr "Fault"
3473 3473 msgid "SUN4U-8006-R5.severity"
3474 3474 msgstr "Critical"
3475 3475 msgid "SUN4U-8006-R5.description"
3476 3476 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3477 3477 msgid "SUN4U-8006-R5.response"
3478 3478 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3479 3479 msgid "SUN4U-8006-R5.impact"
3480 3480 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3481 3481 msgid "SUN4U-8006-R5.action"
3482 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3482 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3483 3483 #
3484 3484 # code: SUN4U-8006-SS
3485 3485 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3486 3486 #
3487 3487 msgid "SUN4U-8006-SS.type"
3488 3488 msgstr "Fault"
3489 3489 msgid "SUN4U-8006-SS.severity"
3490 3490 msgstr "Critical"
3491 3491 msgid "SUN4U-8006-SS.description"
3492 3492 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3493 3493 msgid "SUN4U-8006-SS.response"
3494 3494 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3495 3495 msgid "SUN4U-8006-SS.impact"
3496 3496 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3497 3497 msgid "SUN4U-8006-SS.action"
3498 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3498 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3499 3499 #
3500 3500 # code: SUN4U-8006-TA
3501 3501 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3502 3502 #
3503 3503 msgid "SUN4U-8006-TA.type"
3504 3504 msgstr "Fault"
3505 3505 msgid "SUN4U-8006-TA.severity"
3506 3506 msgstr "Critical"
3507 3507 msgid "SUN4U-8006-TA.description"
3508 3508 msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information."
3509 3509 msgid "SUN4U-8006-TA.response"
3510 3510 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3511 3511 msgid "SUN4U-8006-TA.impact"
3512 3512 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3513 3513 msgid "SUN4U-8006-TA.action"
3514 -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3514 +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
3515 3515 #
3516 3516 # code: SUN4U-8006-UP
3517 3517 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3518 3518 #
3519 3519 msgid "SUN4U-8006-UP.type"
3520 3520 msgstr "Fault"
3521 3521 msgid "SUN4U-8006-UP.severity"
3522 3522 msgstr "Critical"
3523 3523 msgid "SUN4U-8006-UP.description"
3524 3524 msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information."
3525 3525 msgid "SUN4U-8006-UP.response"
3526 3526 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3527 3527 msgid "SUN4U-8006-UP.impact"
3528 3528 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3529 3529 msgid "SUN4U-8006-UP.action"
3530 -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3530 +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n"
3531 3531 #
3532 3532 # code: SUN4U-8006-VD
3533 3533 # keys: fault.cpu.ultraSPARC-IIIiplus.dcache
3534 3534 #
3535 3535 msgid "SUN4U-8006-VD.type"
3536 3536 msgstr "Fault"
3537 3537 msgid "SUN4U-8006-VD.severity"
3538 3538 msgstr "Major"
3539 3539 msgid "SUN4U-8006-VD.description"
3540 3540 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
3541 3541 msgid "SUN4U-8006-VD.response"
3542 3542 msgstr "The fault manager will attempt to remove the affected CPU from service."
3543 3543 msgid "SUN4U-8006-VD.impact"
3544 3544 msgstr "System performance may be affected."
3545 3545 msgid "SUN4U-8006-VD.action"
3546 3546 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3547 3547 #
3548 3548 # code: SUN4U-8006-WH
3549 3549 # keys: fault.cpu.ultraSPARC-IIIiplus.icache
3550 3550 #
3551 3551 msgid "SUN4U-8006-WH.type"
3552 3552 msgstr "Fault"
3553 3553 msgid "SUN4U-8006-WH.severity"
3554 3554 msgstr "Major"
3555 3555 msgid "SUN4U-8006-WH.description"
3556 3556 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
3557 3557 msgid "SUN4U-8006-WH.response"
3558 3558 msgstr "The fault manager will attempt to remove the affected CPU from service."
3559 3559 msgid "SUN4U-8006-WH.impact"
3560 3560 msgstr "System performance may be affected."
3561 3561 msgid "SUN4U-8006-WH.action"
3562 3562 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3563 3563 #
3564 3564 # code: SUN4U-8006-X3
3565 3565 # keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata
3566 3566 #
3567 3567 msgid "SUN4U-8006-X3.type"
3568 3568 msgstr "Fault"
3569 3569 msgid "SUN4U-8006-X3.severity"
3570 3570 msgstr "Major"
3571 3571 msgid "SUN4U-8006-X3.description"
3572 3572 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
3573 3573 msgid "SUN4U-8006-X3.response"
3574 3574 msgstr "The fault manager will attempt to remove the affected CPU from service."
3575 3575 msgid "SUN4U-8006-X3.impact"
3576 3576 msgstr "System performance may be affected."
3577 3577 msgid "SUN4U-8006-X3.action"
3578 3578 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3579 3579 #
3580 3580 # code: SUN4U-8006-YY
3581 3581 # keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag
3582 3582 #
3583 3583 msgid "SUN4U-8006-YY.type"
3584 3584 msgstr "Fault"
3585 3585 msgid "SUN4U-8006-YY.severity"
3586 3586 msgstr "Major"
3587 3587 msgid "SUN4U-8006-YY.description"
3588 3588 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
3589 3589 msgid "SUN4U-8006-YY.response"
3590 3590 msgstr "The fault manager will attempt to remove the affected CPU from service."
3591 3591 msgid "SUN4U-8006-YY.impact"
3592 3592 msgstr "System performance may be affected."
3593 3593 msgid "SUN4U-8006-YY.action"
3594 3594 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3595 3595 #
3596 3596 # code: SUN4U-8007-03
3597 3597 # keys: fault.cpu.ultraSPARC-IIIiplus.fpu
3598 3598 #
3599 3599 msgid "SUN4U-8007-03.type"
3600 3600 msgstr "Fault"
3601 3601 msgid "SUN4U-8007-03.severity"
3602 3602 msgstr "Major"
3603 3603 msgid "SUN4U-8007-03.description"
3604 3604 msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information."
3605 3605 msgid "SUN4U-8007-03.response"
3606 3606 msgstr "The fault manager will attempt to remove the affected CPU from service."
3607 3607 msgid "SUN4U-8007-03.impact"
3608 3608 msgstr "System performance may be affected."
3609 3609 msgid "SUN4U-8007-03.action"
3610 3610 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3611 3611 #
3612 3612 # code: SUN4U-8007-1Y
3613 3613 # keys: fault.asic.cds.dp
3614 3614 #
3615 3615 msgid "SUN4U-8007-1Y.type"
3616 3616 msgstr "Fault"
3617 3617 msgid "SUN4U-8007-1Y.severity"
3618 3618 msgstr "Critical"
3619 3619 msgid "SUN4U-8007-1Y.description"
3620 3620 msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information."
3621 3621 msgid "SUN4U-8007-1Y.response"
3622 3622 msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3623 3623 msgid "SUN4U-8007-1Y.impact"
3624 3624 msgstr "System performace may be affected.\n"
3625 3625 msgid "SUN4U-8007-1Y.action"
3626 3626 msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3627 3627 #
3628 3628 # code: SUN4U-8007-2D
3629 3629 # keys: fault.asic.dx.dp
3630 3630 #
3631 3631 msgid "SUN4U-8007-2D.type"
3632 3632 msgstr "Fault"
3633 3633 msgid "SUN4U-8007-2D.severity"
3634 3634 msgstr "Critical"
3635 3635 msgid "SUN4U-8007-2D.description"
3636 3636 msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information."
3637 3637 msgid "SUN4U-8007-2D.response"
3638 3638 msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3639 3639 msgid "SUN4U-8007-2D.impact"
3640 3640 msgstr "System performace may be affected.\n"
3641 3641 msgid "SUN4U-8007-2D.action"
3642 3642 msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3643 3643 #
3644 3644 # code: SUN4U-8007-3H
3645 3645 # keys: fault.asic.sdi.dp
3646 3646 #
3647 3647 msgid "SUN4U-8007-3H.type"
3648 3648 msgstr "Fault"
3649 3649 msgid "SUN4U-8007-3H.severity"
3650 3650 msgstr "Critical"
3651 3651 msgid "SUN4U-8007-3H.description"
3652 3652 msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information."
3653 3653 msgid "SUN4U-8007-3H.response"
3654 3654 msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3655 3655 msgid "SUN4U-8007-3H.impact"
3656 3656 msgstr "System performace may be affected.\n"
3657 3657 msgid "SUN4U-8007-3H.action"
3658 3658 msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3659 3659 #
3660 3660 # code: SUN4U-8007-4A
3661 3661 # keys: fault.asic.cp.dp
3662 3662 #
3663 3663 msgid "SUN4U-8007-4A.type"
3664 3664 msgstr "Fault"
3665 3665 msgid "SUN4U-8007-4A.severity"
3666 3666 msgstr "Critical"
3667 3667 msgid "SUN4U-8007-4A.description"
3668 3668 msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information."
3669 3669 msgid "SUN4U-8007-4A.response"
3670 3670 msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3671 3671 msgid "SUN4U-8007-4A.impact"
3672 3672 msgstr "System performace may be affected.\n"
3673 3673 msgid "SUN4U-8007-4A.action"
3674 3674 msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3675 3675 #
3676 3676 # code: SUN4U-8007-5P
3677 3677 # keys: fault.asic.rp.dp
3678 3678 #
3679 3679 msgid "SUN4U-8007-5P.type"
3680 3680 msgstr "Fault"
3681 3681 msgid "SUN4U-8007-5P.severity"
3682 3682 msgstr "Critical"
3683 3683 msgid "SUN4U-8007-5P.description"
3684 3684 msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information."
3685 3685 msgid "SUN4U-8007-5P.response"
3686 3686 msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3687 3687 msgid "SUN4U-8007-5P.impact"
3688 3688 msgstr "System performace may be affected.\n"
3689 3689 msgid "SUN4U-8007-5P.action"
3690 3690 msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3691 3691 #
3692 3692 # code: SUN4U-8007-65
3693 3693 # keys: fault.io.oberon
3694 3694 #
3695 3695 msgid "SUN4U-8007-65.type"
|
↓ open down ↓ |
155 lines elided |
↑ open up ↑ |
3696 3696 msgstr "Fault"
3697 3697 msgid "SUN4U-8007-65.severity"
3698 3698 msgstr "Critical"
3699 3699 msgid "SUN4U-8007-65.description"
3700 3700 msgstr "Oberon PCI-Express hostbridge fault\n Refer to %s for more information."
3701 3701 msgid "SUN4U-8007-65.response"
3702 3702 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3703 3703 msgid "SUN4U-8007-65.impact"
3704 3704 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3705 3705 msgid "SUN4U-8007-65.action"
3706 -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3706 +msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
3707 3707 #
3708 3708 # code: SUN4U-8007-7S
3709 3709 # keys: fault.cpu.SPARC64-VI.chip
3710 3710 #
3711 3711 msgid "SUN4U-8007-7S.type"
3712 3712 msgstr "Fault"
3713 3713 msgid "SUN4U-8007-7S.severity"
3714 3714 msgstr "Critical"
3715 3715 msgid "SUN4U-8007-7S.description"
3716 3716 msgstr "The number of errors associated with this CHIP has exceeded acceptable levels. Refer to %s for more information."
3717 3717 msgid "SUN4U-8007-7S.response"
3718 3718 msgstr "An attempt will be made to remove the affected CHIP from service."
3719 3719 msgid "SUN4U-8007-7S.impact"
3720 3720 msgstr "The system will not be functioning at the same performance level with the CHIP removal."
3721 3721 msgid "SUN4U-8007-7S.action"
3722 3722 msgstr "Schedule a repair procedure to replace the affected CHIP. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP."
3723 3723 #
3724 3724 # code: SUN4U-8007-8J
3725 3725 # keys: fault.cpu.SPARC64-VI.core
3726 3726 #
3727 3727 msgid "SUN4U-8007-8J.type"
3728 3728 msgstr "Fault"
3729 3729 msgid "SUN4U-8007-8J.severity"
3730 3730 msgstr "Critical"
3731 3731 msgid "SUN4U-8007-8J.description"
3732 3732 msgstr "The number of errors associated with this CORE has exceeded acceptable levels. Refer to %s for more information."
3733 3733 msgid "SUN4U-8007-8J.response"
3734 3734 msgstr "An attempt will be made to remove the affected CORE from service."
3735 3735 msgid "SUN4U-8007-8J.impact"
3736 3736 msgstr "The system will not be functioning at the same performance level with the CORE removal."
3737 3737 msgid "SUN4U-8007-8J.action"
3738 3738 msgstr "Schedule a repair procedure to replace the affected CORE. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n"
3739 3739 #
3740 3740 # code: SUN4U-8007-9E
3741 3741 # keys: fault.cpu.SPARC64-VI.strand
3742 3742 #
3743 3743 msgid "SUN4U-8007-9E.type"
3744 3744 msgstr "Fault"
3745 3745 msgid "SUN4U-8007-9E.severity"
3746 3746 msgstr "Critical"
3747 3747 msgid "SUN4U-8007-9E.description"
3748 3748 msgstr "The number of errors associated with this STRAND has exceeded acceptable levels. Refer to %s for more information."
3749 3749 msgid "SUN4U-8007-9E.response"
3750 3750 msgstr "An attempt will be made to remove the affected STRAND from service."
3751 3751 msgid "SUN4U-8007-9E.impact"
3752 3752 msgstr "The system will not be functioning at the same performance level with the STRAND removal."
3753 3753 msgid "SUN4U-8007-9E.action"
3754 3754 msgstr "Schedule a repair procedure to replace the affected STRAND. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n"
3755 3755 #
3756 3756 # code: SUN4U-8007-AX
3757 3757 # keys: fault.io.pci.device-invreq fault.io.tomatillo
3758 3758 #
3759 3759 msgid "SUN4U-8007-AX.type"
|
↓ open down ↓ |
43 lines elided |
↑ open up ↑ |
3760 3760 msgstr "Fault"
3761 3761 msgid "SUN4U-8007-AX.severity"
3762 3762 msgstr "Critical"
3763 3763 msgid "SUN4U-8007-AX.description"
3764 3764 msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information."
3765 3765 msgid "SUN4U-8007-AX.response"
3766 3766 msgstr "One or more device instances may be disabled\n"
3767 3767 msgid "SUN4U-8007-AX.impact"
3768 3768 msgstr "Loss of services provided by the device instances associated with this fault\n"
3769 3769 msgid "SUN4U-8007-AX.action"
3770 -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for support.\n"
3770 +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact your illumos distribution team for support.\n"
3771 3771 #
3772 3772 # code: SUN4U-8007-C2
3773 3773 # keys: fault.cpu.SPARC64-VII.chip
3774 3774 #
3775 3775 msgid "SUN4U-8007-C2.type"
3776 3776 msgstr "Fault"
3777 3777 msgid "SUN4U-8007-C2.severity"
3778 3778 msgstr "Critical"
3779 3779 msgid "SUN4U-8007-C2.description"
3780 3780 msgstr "The number of errors associated with this CHIP has exceeded acceptable levels. Refer to %s for more information."
3781 3781 msgid "SUN4U-8007-C2.response"
3782 3782 msgstr "An attempt will be made to remove the affected CHIP from service."
3783 3783 msgid "SUN4U-8007-C2.impact"
3784 3784 msgstr "The system will not be functioning at the same performance level with the CHIP removal."
3785 3785 msgid "SUN4U-8007-C2.action"
3786 3786 msgstr "Schedule a repair procedure to replace the affected CHIP. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP."
3787 3787 #
3788 3788 # code: SUN4U-8007-DR
3789 3789 # keys: fault.cpu.SPARC64-VII.core
3790 3790 #
3791 3791 msgid "SUN4U-8007-DR.type"
3792 3792 msgstr "Fault"
3793 3793 msgid "SUN4U-8007-DR.severity"
3794 3794 msgstr "Critical"
3795 3795 msgid "SUN4U-8007-DR.description"
3796 3796 msgstr "The number of errors associated with this CORE has exceeded acceptable levels. Refer to %s for more information."
3797 3797 msgid "SUN4U-8007-DR.response"
3798 3798 msgstr "An attempt will be made to remove the affected CORE from service."
3799 3799 msgid "SUN4U-8007-DR.impact"
3800 3800 msgstr "The system will not be functioning at the same performance level with the CORE removal."
3801 3801 msgid "SUN4U-8007-DR.action"
3802 3802 msgstr "Schedule a repair procedure to replace the affected CORE. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n"
3803 3803 #
3804 3804 # code: SUN4U-8007-E4
3805 3805 # keys: fault.cpu.SPARC64-VII.strand
3806 3806 #
3807 3807 msgid "SUN4U-8007-E4.type"
3808 3808 msgstr "Fault"
3809 3809 msgid "SUN4U-8007-E4.severity"
3810 3810 msgstr "Critical"
3811 3811 msgid "SUN4U-8007-E4.description"
3812 3812 msgstr "The number of errors associated with this STRAND has exceeded acceptable levels. Refer to %s for more information."
3813 3813 msgid "SUN4U-8007-E4.response"
3814 3814 msgstr "An attempt will be made to remove the affected STRAND from service."
3815 3815 msgid "SUN4U-8007-E4.impact"
3816 3816 msgstr "The system will not be functioning at the same performance level with the STRAND removal."
3817 3817 msgid "SUN4U-8007-E4.action"
|
↓ open down ↓ |
37 lines elided |
↑ open up ↑ |
3818 3818 msgstr "Schedule a repair procedure to replace the affected STRAND. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n"
3819 3819 #
3820 3820 # code: SUN4U-8007-FQ
3821 3821 # keys: fault.cpu.ultraSPARC-IVplus.l2cachedata-line
3822 3822 #
3823 3823 msgid "SUN4U-8007-FQ.type"
3824 3824 msgstr "Fault"
3825 3825 msgid "SUN4U-8007-FQ.severity"
3826 3826 msgstr "Minor"
3827 3827 msgid "SUN4U-8007-FQ.description"
3828 -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3828 +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3829 3829 msgid "SUN4U-8007-FQ.response"
3830 3830 msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3831 3831 msgid "SUN4U-8007-FQ.impact"
3832 3832 msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3833 3833 msgid "SUN4U-8007-FQ.action"
3834 3834 msgstr "No repair action is recommended at this time.\n"
3835 3835 #
3836 3836 # code: SUN4U-8007-GC
3837 3837 # keys: fault.cpu.ultraSPARC-IVplus.l3cachedata-line
3838 3838 #
3839 3839 msgid "SUN4U-8007-GC.type"
3840 3840 msgstr "Fault"
3841 3841 msgid "SUN4U-8007-GC.severity"
3842 3842 msgstr "Minor"
3843 3843 msgid "SUN4U-8007-GC.description"
3844 -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3844 +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3845 3845 msgid "SUN4U-8007-GC.response"
3846 3846 msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3847 3847 msgid "SUN4U-8007-GC.impact"
3848 3848 msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3849 3849 msgid "SUN4U-8007-GC.action"
3850 3850 msgstr "No repair action is recommended at this time.\n"
3851 3851 #
3852 3852 # code: SUN4U-8007-HH
3853 3853 # keys: fault.cpu.ultraSPARC-IVplus.l2cachetag-line
3854 3854 #
3855 3855 msgid "SUN4U-8007-HH.type"
3856 3856 msgstr "Fault"
3857 3857 msgid "SUN4U-8007-HH.severity"
3858 3858 msgstr "Minor"
3859 3859 msgid "SUN4U-8007-HH.description"
3860 -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3860 +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3861 3861 msgid "SUN4U-8007-HH.response"
3862 3862 msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3863 3863 msgid "SUN4U-8007-HH.impact"
3864 3864 msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3865 3865 msgid "SUN4U-8007-HH.action"
3866 3866 msgstr "No repair action is recommended at this time.\n"
3867 3867 #
3868 3868 # code: SUN4U-8007-JD
3869 3869 # keys: fault.cpu.ultraSPARC-IVplus.l3cachetag-line
3870 3870 #
3871 3871 msgid "SUN4U-8007-JD.type"
3872 3872 msgstr "Fault"
3873 3873 msgid "SUN4U-8007-JD.severity"
3874 3874 msgstr "Minor"
3875 3875 msgid "SUN4U-8007-JD.description"
3876 -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3876 +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information."
3877 3877 msgid "SUN4U-8007-JD.response"
3878 3878 msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3879 3879 msgid "SUN4U-8007-JD.impact"
3880 3880 msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3881 3881 msgid "SUN4U-8007-JD.action"
3882 3882 msgstr "No repair action is recommended at this time.\n"
3883 3883 #
3884 3884 # code: SUN4U-8007-KY
3885 3885 # keys: fault.memory.dimm-page-retires-excessive
3886 3886 #
3887 3887 msgid "SUN4U-8007-KY.type"
3888 3888 msgstr "Fault"
3889 3889 msgid "SUN4U-8007-KY.severity"
3890 3890 msgstr "Major"
3891 3891 msgid "SUN4U-8007-KY.description"
3892 3892 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n Refer to %s for more information."
3893 3893 msgid "SUN4U-8007-KY.response"
3894 3894 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
3895 3895 msgid "SUN4U-8007-KY.impact"
3896 3896 msgstr "Total system memory capacity has been reduced.\n"
3897 3897 msgid "SUN4U-8007-KY.action"
3898 3898 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
3899 3899 #
3900 3900 # code: SUN4U-8007-L3
3901 3901 # keys: fault.memory.dimm-ue-imminent
3902 3902 #
3903 3903 msgid "SUN4U-8007-L3.type"
3904 3904 msgstr "Fault"
3905 3905 msgid "SUN4U-8007-L3.severity"
3906 3906 msgstr "Critical"
3907 3907 msgid "SUN4U-8007-L3.description"
3908 3908 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information."
3909 3909 msgid "SUN4U-8007-L3.response"
3910 3910 msgstr "None at this time.\n"
3911 3911 msgid "SUN4U-8007-L3.impact"
3912 3912 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
3913 3913 msgid "SUN4U-8007-L3.action"
3914 3914 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
3915 3915 #
3916 3916 # code: SUN4U-8007-MS
3917 3917 # keys: fault.memory.dram-ue-imminent
3918 3918 #
3919 3919 msgid "SUN4U-8007-MS.type"
3920 3920 msgstr "Fault"
3921 3921 msgid "SUN4U-8007-MS.severity"
3922 3922 msgstr "Critical"
3923 3923 msgid "SUN4U-8007-MS.description"
3924 3924 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information."
3925 3925 msgid "SUN4U-8007-MS.response"
3926 3926 msgstr "None at this time.\n"
3927 3927 msgid "SUN4U-8007-MS.impact"
3928 3928 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
3929 3929 msgid "SUN4U-8007-MS.action"
3930 3930 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
|
↓ open down ↓ |
44 lines elided |
↑ open up ↑ |
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX