Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>

Split Close
Expand all
Collapse all
          --- old/usr/src/cmd/fm/dicts/SUNOS.po
          +++ new/usr/src/cmd/fm/dicts/SUNOS.po
↓ open down ↓ 26 lines elided ↑ open up ↑
  27   27  # code: SUNOS-8000-0G
  28   28  # keys: ereport.sunos.unix.fm_panic
  29   29  #
  30   30  msgid "SUNOS-8000-0G.type"
  31   31  msgstr "Error"
  32   32  msgid "SUNOS-8000-0G.severity"
  33   33  msgstr "Major"
  34   34  msgid "SUNOS-8000-0G.description"
  35   35  msgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
  36   36  msgid "SUNOS-8000-0G.response"
  37      -msgstr "Solaris will attempt to save and diagnose the error telemetry"
       37 +msgstr "illumos will attempt to save and diagnose the error telemetry"
  38   38  msgid "SUNOS-8000-0G.impact"
  39   39  msgstr "The system will sync files, save a crash dump if needed, and reboot"
  40   40  msgid "SUNOS-8000-0G.action"
  41   41  msgstr "Save the error summary below in case telemetry cannot be saved"
  42   42  #
  43   43  # code: SUNOS-8000-1L
  44   44  # keys: defect.sunos.eft.undiagnosable_problem
  45   45  #
  46   46  msgid "SUNOS-8000-1L.type"
  47   47  msgstr "Defect"
  48   48  msgid "SUNOS-8000-1L.severity"
  49   49  msgstr "Minor"
  50   50  msgid "SUNOS-8000-1L.description"
  51   51  msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
  52   52  msgid "SUNOS-8000-1L.response"
  53      -msgstr "Error reports from the component will be logged for examination by Sun."
       53 +msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
  54   54  msgid "SUNOS-8000-1L.impact"
  55   55  msgstr "Automated diagnosis and response for these events will not occur."
  56   56  msgid "SUNOS-8000-1L.action"
  57      -msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support."
       57 +msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
  58   58  #
  59   59  # code: SUNOS-8000-20
  60   60  # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
  61   61  #
  62   62  msgid "SUNOS-8000-20.type"
  63   63  msgstr "Fault"
  64   64  msgid "SUNOS-8000-20.severity"
  65   65  msgstr "Critical"
  66   66  msgid "SUNOS-8000-20.description"
  67   67  msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
  68   68  msgid "SUNOS-8000-20.response"
  69   69  msgstr "One or more of device instances may be disabled"
  70   70  msgid "SUNOS-8000-20.impact"
  71   71  msgstr "Loss of services provided by the device instances associated with this fault"
  72   72  msgid "SUNOS-8000-20.action"
  73      -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
       73 +msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
  74   74  #
  75   75  # code: SUNOS-8000-3V
  76   76  # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
  77   77  #
  78   78  msgid "SUNOS-8000-3V.type"
  79   79  msgstr "Fault"
  80   80  msgid "SUNOS-8000-3V.severity"
  81   81  msgstr "Critical"
  82   82  msgid "SUNOS-8000-3V.description"
  83   83  msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
  84   84  msgid "SUNOS-8000-3V.response"
  85   85  msgstr "One or more of device instances may be disabled"
  86   86  msgid "SUNOS-8000-3V.impact"
  87   87  msgstr "Loss of services provided by the device instances associated with this fault"
  88   88  msgid "SUNOS-8000-3V.action"
  89      -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
       89 +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
  90   90  #
  91   91  # code: SUNOS-8000-46
  92   92  # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
  93   93  #
  94   94  msgid "SUNOS-8000-46.type"
  95   95  msgstr "Fault"
  96   96  msgid "SUNOS-8000-46.severity"
  97   97  msgstr "Critical"
  98   98  msgid "SUNOS-8000-46.description"
  99   99  msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
 100  100  msgid "SUNOS-8000-46.response"
 101  101  msgstr "One or more of device instances may be disabled"
 102  102  msgid "SUNOS-8000-46.impact"
 103  103  msgstr "Loss of services provided by the device instances associated with this fault"
 104  104  msgid "SUNOS-8000-46.action"
 105      -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
      105 +msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
 106  106  #
 107  107  # code: SUNOS-8000-5T
 108  108  # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
 109  109  #
 110  110  msgid "SUNOS-8000-5T.type"
 111  111  msgstr "Fault"
 112  112  msgid "SUNOS-8000-5T.severity"
 113  113  msgstr "Critical"
 114  114  msgid "SUNOS-8000-5T.description"
 115  115  msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
 116  116  msgid "SUNOS-8000-5T.response"
 117  117  msgstr "One or more of device instances may be disabled"
 118  118  msgid "SUNOS-8000-5T.impact"
 119  119  msgstr "Loss of services provided by the device instances associated with this fault"
 120  120  msgid "SUNOS-8000-5T.action"
 121      -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
      121 +msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
 122  122  #
 123  123  # code: SUNOS-8000-69
 124  124  # keys: defect.Deprecated fault.io.pci.device
 125  125  #
 126  126  msgid "SUNOS-8000-69.type"
 127  127  msgstr "Fault"
 128  128  msgid "SUNOS-8000-69.severity"
 129  129  msgstr "Critical"
 130  130  msgid "SUNOS-8000-69.description"
 131  131  msgstr "A problem was detected for a PCI controller  Refer to %s for more information."
 132  132  msgid "SUNOS-8000-69.response"
 133  133  msgstr "One or more of device instances may be disabled"
 134  134  msgid "SUNOS-8000-69.impact"
 135  135  msgstr "Loss of services provided by the device instances associated with this fault."
 136  136  msgid "SUNOS-8000-69.action"
 137      -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
      137 +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
 138  138  #
 139  139  # code: SUNOS-8000-7N
 140  140  # keys: defect.Deprecated fault.io.pci.bus
 141  141  #
 142  142  msgid "SUNOS-8000-7N.type"
 143  143  msgstr "Fault"
 144  144  msgid "SUNOS-8000-7N.severity"
 145  145  msgstr "Critical"
 146  146  msgid "SUNOS-8000-7N.description"
 147  147  msgstr "A problem was detected for a PCI bus  Refer to %s for more information."
 148  148  msgid "SUNOS-8000-7N.response"
 149  149  msgstr "One or more of device instances may be disabled"
 150  150  msgid "SUNOS-8000-7N.impact"
 151  151  msgstr "Loss of services provided by the device instances associated with this fault."
 152  152  msgid "SUNOS-8000-7N.action"
 153      -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
      153 +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
 154  154  #
 155  155  # code: SUNOS-8000-8W
 156  156  # keys: defect.Deprecated defect.io.pci.driver
 157  157  #
 158  158  msgid "SUNOS-8000-8W.type"
 159  159  msgstr "Fault"
 160  160  msgid "SUNOS-8000-8W.severity"
 161  161  msgstr "Critical"
 162  162  msgid "SUNOS-8000-8W.description"
 163  163  msgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
 164  164  msgid "SUNOS-8000-8W.response"
 165  165  msgstr "One or more of device instances may be disabled"
 166  166  msgid "SUNOS-8000-8W.impact"
 167  167  msgstr "Loss of services provided by the device instances associated with this fault."
 168  168  msgid "SUNOS-8000-8W.action"
 169      -msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
      169 +msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
 170  170  #
 171  171  # code: SUNOS-8000-91
 172  172  # keys: defect.sunos.zones.upgrade
 173  173  #
 174  174  msgid "SUNOS-8000-91.type"
 175  175  msgstr "Defect"
 176  176  msgid "SUNOS-8000-91.severity"
 177  177  msgstr "Minor"
 178  178  msgid "SUNOS-8000-91.description"
 179      -msgstr "\n      The Solaris system or boot environment that is being upgraded\n has non-global zones installed.  The current version of Live\n  Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n        Refer to %s for more information."
      179 +msgstr "\n      The illumos system or boot environment that is being upgraded\n has non-global zones installed.  The current version of Live\n  Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n        Refer to %s for more information."
 180  180  msgid "SUNOS-8000-91.response"
 181  181  msgstr "The upgrade procedure has been terminated."
 182  182  msgid "SUNOS-8000-91.impact"
 183      -msgstr "The Solaris system or boot environment is not upgraded."
      183 +msgstr "The illumos system or boot environment is not upgraded."
 184  184  msgid "SUNOS-8000-91.action"
 185      -msgstr "\n      Evaluate each of the choices below and select the one that is\n best for your needs.  Contact Sun for support.\n        "
      185 +msgstr "\n      Evaluate each of the choices below and select the one that is\n best for your needs.  Contact your illumos distribution team for support.\n     "
 186  186  #
 187  187  # code: SUNOS-8000-AK
 188  188  # keys: ereport.sunos.boot.upgrade.menu_lst
 189  189  #
 190  190  msgid "SUNOS-8000-AK.type"
 191  191  msgstr "Error"
 192  192  msgid "SUNOS-8000-AK.severity"
 193  193  msgstr "Critical"
 194  194  msgid "SUNOS-8000-AK.description"
 195      -msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
      195 +msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
 196  196  msgid "SUNOS-8000-AK.response"
 197  197  msgstr "No automated response."
 198  198  msgid "SUNOS-8000-AK.impact"
 199  199  msgstr "Future reboots could fail until this problem is corrected."
 200  200  msgid "SUNOS-8000-AK.action"
 201  201  msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
 202  202  #
 203  203  # code: SUNOS-8000-CF
 204  204  # keys: ereport.sunos.boot.upgrade.menu_lst_bfu
 205  205  #
 206  206  msgid "SUNOS-8000-CF.type"
 207  207  msgstr "Error"
 208  208  msgid "SUNOS-8000-CF.severity"
 209  209  msgstr "Critical"
 210  210  msgid "SUNOS-8000-CF.description"
 211      -msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
      211 +msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
 212  212  msgid "SUNOS-8000-CF.response"
 213  213  msgstr "No automated response."
 214  214  msgid "SUNOS-8000-CF.impact"
 215  215  msgstr "Future reboots could fail until this problem is corrected."
 216  216  msgid "SUNOS-8000-CF.action"
 217  217  msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
 218  218  #
 219  219  # code: SUNOS-8000-DM
 220  220  # keys: defect.sunos.smf.svc.maintenance
 221  221  #
↓ open down ↓ 13 lines elided ↑ open up ↑
 235  235  # code: SUNOS-8000-E8
 236  236  # keys: defect.sunos.eft.undiag.checkpoint
 237  237  #
 238  238  msgid "SUNOS-8000-E8.type"
 239  239  msgstr "Defect"
 240  240  msgid "SUNOS-8000-E8.severity"
 241  241  msgstr "Minor"
 242  242  msgid "SUNOS-8000-E8.description"
 243  243  msgstr "The diagnosis engine encountered an error while resuming diagnosis.  Refer to %s for more information."
 244  244  msgid "SUNOS-8000-E8.response"
 245      -msgstr "Error reports have been logged for examination by Sun."
      245 +msgstr "Error reports have been logged for examination by your illumos distribution team."
 246  246  msgid "SUNOS-8000-E8.impact"
 247  247  msgstr "Automated diagnosis and response for these events will not occur."
 248  248  msgid "SUNOS-8000-E8.action"
 249  249  msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager."
 250  250  #
 251  251  # code: SUNOS-8000-FU
 252  252  # keys: defect.sunos.eft.undiag.fme
 253  253  #
 254  254  msgid "SUNOS-8000-FU.type"
 255  255  msgstr "Defect"
 256  256  msgid "SUNOS-8000-FU.severity"
 257  257  msgstr "Major"
 258  258  msgid "SUNOS-8000-FU.description"
 259  259  msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
 260  260  msgid "SUNOS-8000-FU.response"
 261      -msgstr "Error reports have been logged for examination by Sun."
      261 +msgstr "Error reports have been logged for examination by your illumos distribution team."
 262  262  msgid "SUNOS-8000-FU.impact"
 263  263  msgstr "Automated diagnosis and response for these events will not occur."
 264  264  msgid "SUNOS-8000-FU.action"
 265      -msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed."
      265 +msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
 266  266  #
 267  267  # code: SUNOS-8000-G7
 268  268  # keys: defect.sunos.eft.undiag.limit
 269  269  #
 270  270  msgid "SUNOS-8000-G7.type"
 271  271  msgstr "Defect"
 272  272  msgid "SUNOS-8000-G7.severity"
 273  273  msgstr "Minor"
 274  274  msgid "SUNOS-8000-G7.description"
 275  275  msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis.  Refer to %s for more information."
 276  276  msgid "SUNOS-8000-G7.response"
 277      -msgstr "Error reports have been logged for examination by Sun."
      277 +msgstr "Error reports have been logged for examination by your illumos distribution team."
 278  278  msgid "SUNOS-8000-G7.impact"
 279  279  msgstr "Automated diagnosis and response for these events will not occur."
 280  280  msgid "SUNOS-8000-G7.action"
 281  281  msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
 282  282  #
 283  283  # code: SUNOS-8000-HV
 284  284  # keys: defect.sunos.eft.undiag.unknown
 285  285  #
 286  286  msgid "SUNOS-8000-HV.type"
 287  287  msgstr "Defect"
 288  288  msgid "SUNOS-8000-HV.severity"
 289  289  msgstr "Minor"
 290  290  msgid "SUNOS-8000-HV.description"
 291  291  msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
 292  292  msgid "SUNOS-8000-HV.response"
 293      -msgstr "Error reports have been logged for examination by Sun."
      293 +msgstr "Error reports have been logged for examination by your illumos distribution team."
 294  294  msgid "SUNOS-8000-HV.impact"
 295  295  msgstr "Automated diagnosis and response for these events will not occur."
 296  296  msgid "SUNOS-8000-HV.action"
 297      -msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed."
      297 +msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
 298  298  #
 299  299  # code: SUNOS-8000-J0
 300  300  # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry
 301  301  #
 302  302  msgid "SUNOS-8000-J0.type"
 303  303  msgstr "Fault"
 304  304  msgid "SUNOS-8000-J0.severity"
 305  305  msgstr "Major"
 306  306  msgid "SUNOS-8000-J0.description"
 307  307  msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n  Refer to %s for more information.  Refer to %s for more information."
 308  308  msgid "SUNOS-8000-J0.response"
 309      -msgstr "Error reports have been logged for examination by Sun.\n"
      309 +msgstr "Error reports have been logged for examination by your illumos distribution team.\n"
 310  310  msgid "SUNOS-8000-J0.impact"
 311  311  msgstr "Automated diagnosis and response for these events will not occur.\n"
 312  312  msgid "SUNOS-8000-J0.action"
 313      -msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed.\n"
      313 +msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n"
 314  314  #
 315  315  # code: SUNOS-8000-KL
 316  316  # keys: defect.sunos.kernel.panic
 317  317  #
 318  318  msgid "SUNOS-8000-KL.type"
 319  319  msgstr "Defect"
 320  320  msgid "SUNOS-8000-KL.severity"
 321  321  msgstr "Major"
 322  322  msgid "SUNOS-8000-KL.description"
 323  323  msgstr "The system has rebooted after a kernel panic.  Refer to %s for more information."
 324  324  msgid "SUNOS-8000-KL.response"
 325  325  msgstr "The failed system image was dumped to the dump device.  If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>."
 326  326  msgid "SUNOS-8000-KL.impact"
 327  327  msgstr "There may be some performance impact while the panic is copied to the savecore directory.  Disk space usage by panics can be substantial."
 328  328  msgid "SUNOS-8000-KL.action"
 329  329  msgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail.  Please refer to the knowledge article for additional information."
    
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX