8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>

Split Close
Expand all
Collapse all
          --- old/usr/src/cmd/fm/dicts/SUN4V.po
          +++ new/usr/src/cmd/fm/dicts/SUN4V.po
↓ open down ↓ 238 lines elided ↑ open up ↑
 239  239  msgstr "Fault"
 240  240  msgid "SUN4V-8000-FJ.severity"
 241  241  msgstr "Major"
 242  242  msgid "SUN4V-8000-FJ.description"
 243  243  msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 244  244  msgid "SUN4V-8000-FJ.response"
 245  245  msgstr "No automated response.\n"
 246  246  msgid "SUN4V-8000-FJ.impact"
 247  247  msgstr "System performance may be impacted.\n"
 248  248  msgid "SUN4V-8000-FJ.action"
 249      -msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
      249 +msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 250  250  #
 251  251  # code: SUN4V-8000-GE
 252  252  # keys: fault.cpu.ultraSPARC-T2.ireg
 253  253  #
 254  254  msgid "SUN4V-8000-GE.type"
 255  255  msgstr "Fault"
 256  256  msgid "SUN4V-8000-GE.severity"
 257  257  msgstr "Minor"
 258  258  msgid "SUN4V-8000-GE.description"
 259  259  msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
↓ open down ↓ 171 lines elided ↑ open up ↑
 431  431  msgstr "Fault"
 432  432  msgid "SUN4V-8000-TC.severity"
 433  433  msgstr "Critical"
 434  434  msgid "SUN4V-8000-TC.description"
 435  435  msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 436  436  msgid "SUN4V-8000-TC.response"
 437  437  msgstr "No automated response.\n"
 438  438  msgid "SUN4V-8000-TC.impact"
 439  439  msgstr "System performance may be impacted.\n"
 440  440  msgid "SUN4V-8000-TC.action"
 441      -msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
      441 +msgstr "At a convenient time, try reseating the memory module.  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 442  442  #
 443  443  # code: SUN4V-8000-UQ
 444  444  # keys: fault.cpu.ultraSPARC-T2.l2data-u
 445  445  #
 446  446  msgid "SUN4V-8000-UQ.type"
 447  447  msgstr "Fault"
 448  448  msgid "SUN4V-8000-UQ.severity"
 449  449  msgstr "Critical"
 450  450  msgid "SUN4V-8000-UQ.description"
 451  451  msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
↓ open down ↓ 39 lines elided ↑ open up ↑
 491  491  # code: SUN4V-8000-X2
 492  492  # keys: fault.memory.datapath
 493  493  #
 494  494  msgid "SUN4V-8000-X2.type"
 495  495  msgstr "Fault"
 496  496  msgid "SUN4V-8000-X2.severity"
 497  497  msgstr "Major"
 498  498  msgid "SUN4V-8000-X2.description"
 499  499  msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
 500  500  msgid "SUN4V-8000-X2.response"
 501      -msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
      501 +msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n"
 502  502  msgid "SUN4V-8000-X2.impact"
 503  503  msgstr "System performance and stability may be affected. \n"
 504  504  msgid "SUN4V-8000-X2.action"
 505  505  msgstr "Contact your service provider for further diagnosis.\n"
 506  506  #
 507  507  # code: SUN4V-8000-YX
 508  508  # keys: fault.io.n2.ncu
 509  509  #
 510  510  msgid "SUN4V-8000-YX.type"
 511  511  msgstr "Fault"
 512  512  msgid "SUN4V-8000-YX.severity"
 513  513  msgstr "Critical"
 514  514  msgid "SUN4V-8000-YX.description"
 515  515  msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
 516  516  msgid "SUN4V-8000-YX.response"
 517  517  msgstr "One or more device instances may be disabled\n"
 518  518  msgid "SUN4V-8000-YX.impact"
 519  519  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 520  520  msgid "SUN4V-8000-YX.action"
 521      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      521 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n"
 522  522  #
 523  523  # code: SUN4V-8001-02
 524  524  # keys: fault.io.n2.dmu
 525  525  #
 526  526  msgid "SUN4V-8001-02.type"
 527  527  msgstr "Fault"
 528  528  msgid "SUN4V-8001-02.severity"
 529  529  msgstr "Critical"
 530  530  msgid "SUN4V-8001-02.description"
 531  531  msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
 532  532  msgid "SUN4V-8001-02.response"
 533  533  msgstr "One or more device instances may be disabled\n"
 534  534  msgid "SUN4V-8001-02.impact"
 535  535  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 536  536  msgid "SUN4V-8001-02.action"
 537      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      537 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 538  538  #
 539  539  # code: SUN4V-8001-1X
 540  540  # keys: fault.io.n2.niu
 541  541  #
 542  542  msgid "SUN4V-8001-1X.type"
 543  543  msgstr "Fault"
 544  544  msgid "SUN4V-8001-1X.severity"
 545  545  msgstr "Critical"
 546  546  msgid "SUN4V-8001-1X.description"
 547  547  msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
 548  548  msgid "SUN4V-8001-1X.response"
 549  549  msgstr "One or more device instances may be disabled\n"
 550  550  msgid "SUN4V-8001-1X.impact"
 551  551  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 552  552  msgid "SUN4V-8001-1X.action"
 553      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      553 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 554  554  #
 555  555  # code: SUN4V-8001-2E
 556  556  # keys: fault.io.n2.siu
 557  557  #
 558  558  msgid "SUN4V-8001-2E.type"
 559  559  msgstr "Fault"
 560  560  msgid "SUN4V-8001-2E.severity"
 561  561  msgstr "Critical"
 562  562  msgid "SUN4V-8001-2E.description"
 563  563  msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
 564  564  msgid "SUN4V-8001-2E.response"
 565  565  msgstr "One or more device instances may be disabled\n"
 566  566  msgid "SUN4V-8001-2E.impact"
 567  567  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 568  568  msgid "SUN4V-8001-2E.action"
 569      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      569 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 570  570  #
 571  571  # code: SUN4V-8001-3J
 572  572  # keys: fault.io.n2.soc
 573  573  #
 574  574  msgid "SUN4V-8001-3J.type"
 575  575  msgstr "Fault"
 576  576  msgid "SUN4V-8001-3J.severity"
 577  577  msgstr "Critical"
 578  578  msgid "SUN4V-8001-3J.description"
 579  579  msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
 580  580  msgid "SUN4V-8001-3J.response"
 581  581  msgstr "One or more device instances may be disabled\n"
 582  582  msgid "SUN4V-8001-3J.impact"
 583  583  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 584  584  msgid "SUN4V-8001-3J.action"
 585      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      585 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 586  586  #
 587  587  # code: SUN4V-8001-4C
 588  588  # keys: fault.io.n2.crossbar
 589  589  #
 590  590  msgid "SUN4V-8001-4C.type"
 591  591  msgstr "Fault"
 592  592  msgid "SUN4V-8001-4C.severity"
 593  593  msgstr "Critical"
 594  594  msgid "SUN4V-8001-4C.description"
 595  595  msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
 596  596  msgid "SUN4V-8001-4C.response"
 597  597  msgstr "One or more device instances may be disabled\n"
 598  598  msgid "SUN4V-8001-4C.impact"
 599  599  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 600  600  msgid "SUN4V-8001-4C.action"
 601      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      601 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 602  602  #
 603  603  # code: SUN4V-8001-5Q
 604  604  # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
 605  605  #
 606  606  msgid "SUN4V-8001-5Q.type"
 607  607  msgstr "Fault"
 608  608  msgid "SUN4V-8001-5Q.severity"
 609  609  msgstr "Critical"
 610  610  msgid "SUN4V-8001-5Q.description"
 611  611  msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
 612  612  msgid "SUN4V-8001-5Q.response"
 613  613  msgstr "One or more device instances may be disabled\n"
 614  614  msgid "SUN4V-8001-5Q.impact"
 615  615  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 616  616  msgid "SUN4V-8001-5Q.action"
 617      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      617 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 618  618  #
 619  619  # code: SUN4V-8001-64
 620  620  # keys: fault.io.vf.ncx
 621  621  #
 622  622  msgid "SUN4V-8001-64.type"
 623  623  msgstr "Fault"
 624  624  msgid "SUN4V-8001-64.severity"
 625  625  msgstr "Critical"
 626  626  msgid "SUN4V-8001-64.description"
 627  627  msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
 628  628  msgid "SUN4V-8001-64.response"
 629  629  msgstr "One or more device instances may be disabled\n"
 630  630  msgid "SUN4V-8001-64.impact"
 631  631  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 632  632  msgid "SUN4V-8001-64.action"
 633      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      633 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 634  634  #
 635  635  # code: SUN4V-8001-7R
 636  636  # keys: fault.memory.link-f
 637  637  #
 638  638  msgid "SUN4V-8001-7R.type"
 639  639  msgstr "Fault"
 640  640  msgid "SUN4V-8001-7R.severity"
 641  641  msgstr "Major"
 642  642  msgid "SUN4V-8001-7R.description"
 643  643  msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
 644  644  msgid "SUN4V-8001-7R.response"
 645  645  msgstr "No automated response.\n"
 646  646  msgid "SUN4V-8001-7R.impact"
 647  647  msgstr "System performance may be impacted.\n"
 648  648  msgid "SUN4V-8001-7R.action"
 649      -msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
      649 +msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 650  650  #
 651  651  # code: SUN4V-8001-8H
 652  652  # keys: fault.cpu.ultraSPARC-T2plus.ireg
 653  653  #
 654  654  msgid "SUN4V-8001-8H.type"
 655  655  msgstr "Fault"
 656  656  msgid "SUN4V-8001-8H.severity"
 657  657  msgstr "Minor"
 658  658  msgid "SUN4V-8001-8H.description"
 659  659  msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
↓ open down ↓ 811 lines elided ↑ open up ↑
1471 1471  msgstr "Fault"
1472 1472  msgid "SUN4V-8002-US.severity"
1473 1473  msgstr "Critical"
1474 1474  msgid "SUN4V-8002-US.description"
1475 1475  msgstr "The Service Processor failed.\n  Refer to %s for more information."
1476 1476  msgid "SUN4V-8002-US.response"
1477 1477  msgstr "No automated response.\n"
1478 1478  msgid "SUN4V-8002-US.impact"
1479 1479  msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 1480  msgid "SUN4V-8002-US.action"
1481      -msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"
     1481 +msgstr "Schedule a repair procedure for the Service Processor, or contact your illumos distribution team for support.\n"
    