Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
| Split |
Close |
| Expand all |
| Collapse all |
--- old/usr/src/cmd/fm/dicts/SUN4V.po
+++ new/usr/src/cmd/fm/dicts/SUN4V.po
1 1 #
2 2 # Copyright 2009 Sun Microsystems, Inc. All rights reserved.
3 3 # Use is subject to license terms.
4 4 #
5 5 # CDDL HEADER START
6 6 #
7 7 # The contents of this file are subject to the terms of the
8 8 # Common Development and Distribution License (the "License").
9 9 # You may not use this file except in compliance with the License.
10 10 #
11 11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 12 # or http://www.opensolaris.org/os/licensing.
13 13 # See the License for the specific language governing permissions
14 14 # and limitations under the License.
15 15 #
16 16 # When distributing Covered Code, include this CDDL HEADER in each
17 17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 18 # If applicable, add the following below this CDDL HEADER, with the
19 19 # fields enclosed by brackets "[]" replaced with your own identifying
20 20 # information: Portions Copyright [yyyy] [name of copyright owner]
21 21 #
22 22 # CDDL HEADER END
23 23 #
24 24 # DO NOT EDIT -- this file is generated by the Event Registry.
25 25 #
26 26 #
27 27 # code: SUN4V-8000-1S
28 28 # keys: fault.cpu.ultraSPARC-T1.ireg
29 29 #
30 30 msgid "SUN4V-8000-1S.type"
31 31 msgstr "Fault"
32 32 msgid "SUN4V-8000-1S.severity"
33 33 msgstr "Minor"
34 34 msgid "SUN4V-8000-1S.description"
35 35 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
36 36 msgid "SUN4V-8000-1S.response"
37 37 msgstr "The fault manager will attempt to remove the affected CPU from service."
38 38 msgid "SUN4V-8000-1S.impact"
39 39 msgstr "System performance may be affected."
40 40 msgid "SUN4V-8000-1S.action"
41 41 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
42 42 #
43 43 # code: SUN4V-8000-2A
44 44 # keys: fault.cpu.ultraSPARC-T1.freg
45 45 #
46 46 msgid "SUN4V-8000-2A.type"
47 47 msgstr "Fault"
48 48 msgid "SUN4V-8000-2A.severity"
49 49 msgstr "Major"
50 50 msgid "SUN4V-8000-2A.description"
51 51 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
52 52 msgid "SUN4V-8000-2A.response"
53 53 msgstr "None"
54 54 msgid "SUN4V-8000-2A.impact"
55 55 msgstr "System performance may be affected."
56 56 msgid "SUN4V-8000-2A.action"
57 57 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
58 58 #
59 59 # code: SUN4V-8000-3P
60 60 # keys: fault.cpu.ultraSPARC-T1.itlb
61 61 #
62 62 msgid "SUN4V-8000-3P.type"
63 63 msgstr "Fault"
64 64 msgid "SUN4V-8000-3P.severity"
65 65 msgstr "Minor"
66 66 msgid "SUN4V-8000-3P.description"
67 67 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
68 68 msgid "SUN4V-8000-3P.response"
69 69 msgstr "The fault manager will attempt to remove the affected CPU from service."
70 70 msgid "SUN4V-8000-3P.impact"
71 71 msgstr "System performance may be affected.\n"
72 72 msgid "SUN4V-8000-3P.action"
73 73 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
74 74 #
75 75 # code: SUN4V-8000-4D
76 76 # keys: fault.cpu.ultraSPARC-T1.dtlb
77 77 #
78 78 msgid "SUN4V-8000-4D.type"
79 79 msgstr "Fault"
80 80 msgid "SUN4V-8000-4D.severity"
81 81 msgstr "Minor"
82 82 msgid "SUN4V-8000-4D.description"
83 83 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
84 84 msgid "SUN4V-8000-4D.response"
85 85 msgstr "The fault manager will attempt to remove the affected CPU from service."
86 86 msgid "SUN4V-8000-4D.impact"
87 87 msgstr "System performance may be affected.\n"
88 88 msgid "SUN4V-8000-4D.action"
89 89 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
90 90 #
91 91 # code: SUN4V-8000-5H
92 92 # keys: fault.cpu.ultraSPARC-T1.icache
93 93 #
94 94 msgid "SUN4V-8000-5H.type"
95 95 msgstr "Fault"
96 96 msgid "SUN4V-8000-5H.severity"
97 97 msgstr "Minor"
98 98 msgid "SUN4V-8000-5H.description"
99 99 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
100 100 msgid "SUN4V-8000-5H.response"
101 101 msgstr "The fault manager will attempt to remove the affected CPU from service."
102 102 msgid "SUN4V-8000-5H.impact"
103 103 msgstr "System performance may be affected.\n"
104 104 msgid "SUN4V-8000-5H.action"
105 105 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
106 106 #
107 107 # code: SUN4V-8000-63
108 108 # keys: fault.cpu.ultraSPARC-T1.dcache
109 109 #
110 110 msgid "SUN4V-8000-63.type"
111 111 msgstr "Fault"
112 112 msgid "SUN4V-8000-63.severity"
113 113 msgstr "Minor"
114 114 msgid "SUN4V-8000-63.description"
115 115 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
116 116 msgid "SUN4V-8000-63.response"
117 117 msgstr "The fault manager will attempt to remove the affected CPU from service."
118 118 msgid "SUN4V-8000-63.impact"
119 119 msgstr "System performance may be affected.\n"
120 120 msgid "SUN4V-8000-63.action"
121 121 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
122 122 #
123 123 # code: SUN4V-8000-7Y
124 124 # keys: fault.cpu.ultraSPARC-T1.mau
125 125 #
126 126 msgid "SUN4V-8000-7Y.type"
127 127 msgstr "Fault"
128 128 msgid "SUN4V-8000-7Y.severity"
129 129 msgstr "Major"
130 130 msgid "SUN4V-8000-7Y.description"
131 131 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
132 132 msgid "SUN4V-8000-7Y.response"
133 133 msgstr "None"
134 134 msgid "SUN4V-8000-7Y.impact"
135 135 msgstr "System performance may be affected.\n"
136 136 msgid "SUN4V-8000-7Y.action"
137 137 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
138 138 #
139 139 # code: SUN4V-8000-8Q
140 140 # keys: fault.cpu.ultraSPARC-T1.l2cachedata
141 141 #
142 142 msgid "SUN4V-8000-8Q.type"
143 143 msgstr "Fault"
144 144 msgid "SUN4V-8000-8Q.severity"
145 145 msgstr "Critical"
146 146 msgid "SUN4V-8000-8Q.description"
147 147 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
148 148 msgid "SUN4V-8000-8Q.response"
149 149 msgstr "None"
150 150 msgid "SUN4V-8000-8Q.impact"
151 151 msgstr "System performance may be affected.\n"
152 152 msgid "SUN4V-8000-8Q.action"
153 153 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
154 154 #
155 155 # code: SUN4V-8000-9C
156 156 # keys: fault.cpu.ultraSPARC-T1.l2cachetag
157 157 #
158 158 msgid "SUN4V-8000-9C.type"
159 159 msgstr "Fault"
160 160 msgid "SUN4V-8000-9C.severity"
161 161 msgstr "Critical"
162 162 msgid "SUN4V-8000-9C.description"
163 163 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
164 164 msgid "SUN4V-8000-9C.response"
165 165 msgstr "None"
166 166 msgid "SUN4V-8000-9C.impact"
167 167 msgstr "System performance may be affected.\n"
168 168 msgid "SUN4V-8000-9C.action"
169 169 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
170 170 #
171 171 # code: SUN4V-8000-AR
172 172 # keys: fault.cpu.ultraSPARC-T1.l2cachectl
173 173 #
174 174 msgid "SUN4V-8000-AR.type"
175 175 msgstr "Fault"
176 176 msgid "SUN4V-8000-AR.severity"
177 177 msgstr "Critical"
178 178 msgid "SUN4V-8000-AR.description"
179 179 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
180 180 msgid "SUN4V-8000-AR.response"
181 181 msgstr "None"
182 182 msgid "SUN4V-8000-AR.impact"
183 183 msgstr "System performance may be affected.\n"
184 184 msgid "SUN4V-8000-AR.action"
185 185 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
186 186 #
187 187 # code: SUN4V-8000-C4
188 188 # keys: fault.memory.page
189 189 #
190 190 msgid "SUN4V-8000-C4.type"
191 191 msgstr "Fault"
192 192 msgid "SUN4V-8000-C4.severity"
193 193 msgstr "Minor"
194 194 msgid "SUN4V-8000-C4.description"
195 195 msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information."
196 196 msgid "SUN4V-8000-C4.response"
197 197 msgstr "An attempt will be made to remove this memory page from service."
198 198 msgid "SUN4V-8000-C4.impact"
199 199 msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
200 200 msgid "SUN4V-8000-C4.action"
201 201 msgstr "No repair action is recommended at this time."
202 202 #
203 203 # code: SUN4V-8000-DX
204 204 # keys: fault.memory.dimm
205 205 #
206 206 msgid "SUN4V-8000-DX.type"
207 207 msgstr "Fault"
208 208 msgid "SUN4V-8000-DX.severity"
209 209 msgstr "Major"
210 210 msgid "SUN4V-8000-DX.description"
211 211 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information."
212 212 msgid "SUN4V-8000-DX.response"
213 213 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
214 214 msgid "SUN4V-8000-DX.impact"
215 215 msgstr "Total system memory capacity has been reduced."
216 216 msgid "SUN4V-8000-DX.action"
217 217 msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
218 218 #
219 219 # code: SUN4V-8000-E2
220 220 # keys: fault.memory.bank
221 221 #
222 222 msgid "SUN4V-8000-E2.type"
223 223 msgstr "Fault"
224 224 msgid "SUN4V-8000-E2.severity"
225 225 msgstr "Critical"
226 226 msgid "SUN4V-8000-E2.description"
227 227 msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information."
228 228 msgid "SUN4V-8000-E2.response"
229 229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
230 230 msgid "SUN4V-8000-E2.impact"
231 231 msgstr "Total system memory capacity will be reduced as pages are retired."
232 232 msgid "SUN4V-8000-E2.action"
233 233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
234 234 #
235 235 # code: SUN4V-8000-FJ
236 236 # keys: fault.memory.link-c
237 237 #
238 238 msgid "SUN4V-8000-FJ.type"
|
↓ open down ↓ |
238 lines elided |
↑ open up ↑ |
239 239 msgstr "Fault"
240 240 msgid "SUN4V-8000-FJ.severity"
241 241 msgstr "Major"
242 242 msgid "SUN4V-8000-FJ.description"
243 243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
244 244 msgid "SUN4V-8000-FJ.response"
245 245 msgstr "No automated response.\n"
246 246 msgid "SUN4V-8000-FJ.impact"
247 247 msgstr "System performance may be impacted.\n"
248 248 msgid "SUN4V-8000-FJ.action"
249 -msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n"
249 +msgstr "At a convenient time, try reseating the memory module(s). If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
250 250 #
251 251 # code: SUN4V-8000-GE
252 252 # keys: fault.cpu.ultraSPARC-T2.ireg
253 253 #
254 254 msgid "SUN4V-8000-GE.type"
255 255 msgstr "Fault"
256 256 msgid "SUN4V-8000-GE.severity"
257 257 msgstr "Minor"
258 258 msgid "SUN4V-8000-GE.description"
259 259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
260 260 msgid "SUN4V-8000-GE.response"
261 261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
262 262 msgid "SUN4V-8000-GE.impact"
263 263 msgstr "System performance may be affected. \n"
264 264 msgid "SUN4V-8000-GE.action"
265 265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
266 266 #
267 267 # code: SUN4V-8000-HP
268 268 # keys: fault.cpu.ultraSPARC-T2.freg
269 269 #
270 270 msgid "SUN4V-8000-HP.type"
271 271 msgstr "Fault"
272 272 msgid "SUN4V-8000-HP.severity"
273 273 msgstr "Minor"
274 274 msgid "SUN4V-8000-HP.description"
275 275 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
276 276 msgid "SUN4V-8000-HP.response"
277 277 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
278 278 msgid "SUN4V-8000-HP.impact"
279 279 msgstr "System performance may be affected. \n"
280 280 msgid "SUN4V-8000-HP.action"
281 281 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
282 282 #
283 283 # code: SUN4V-8000-JA
284 284 # keys: fault.cpu.ultraSPARC-T2.misc_reg
285 285 #
286 286 msgid "SUN4V-8000-JA.type"
287 287 msgstr "Fault"
288 288 msgid "SUN4V-8000-JA.severity"
289 289 msgstr "Minor"
290 290 msgid "SUN4V-8000-JA.description"
291 291 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
292 292 msgid "SUN4V-8000-JA.response"
293 293 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
294 294 msgid "SUN4V-8000-JA.impact"
295 295 msgstr "System performance may be affected. \n"
296 296 msgid "SUN4V-8000-JA.action"
297 297 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
298 298 #
299 299 # code: SUN4V-8000-KS
300 300 # keys: fault.cpu.ultraSPARC-T2.itlb
301 301 #
302 302 msgid "SUN4V-8000-KS.type"
303 303 msgstr "Fault"
304 304 msgid "SUN4V-8000-KS.severity"
305 305 msgstr "Major"
306 306 msgid "SUN4V-8000-KS.description"
307 307 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
308 308 msgid "SUN4V-8000-KS.response"
309 309 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
310 310 msgid "SUN4V-8000-KS.impact"
311 311 msgstr "System performance is likely to be affected. \n"
312 312 msgid "SUN4V-8000-KS.action"
313 313 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
314 314 #
315 315 # code: SUN4V-8000-L5
316 316 # keys: fault.cpu.ultraSPARC-T2.dtlb
317 317 #
318 318 msgid "SUN4V-8000-L5.type"
319 319 msgstr "Fault"
320 320 msgid "SUN4V-8000-L5.severity"
321 321 msgstr "Major"
322 322 msgid "SUN4V-8000-L5.description"
323 323 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
324 324 msgid "SUN4V-8000-L5.response"
325 325 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
326 326 msgid "SUN4V-8000-L5.impact"
327 327 msgstr "System performance is likely to be affected. \n"
328 328 msgid "SUN4V-8000-L5.action"
329 329 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
330 330 #
331 331 # code: SUN4V-8000-MY
332 332 # keys: fault.cpu.ultraSPARC-T2.icache
333 333 #
334 334 msgid "SUN4V-8000-MY.type"
335 335 msgstr "Fault"
336 336 msgid "SUN4V-8000-MY.severity"
337 337 msgstr "Major"
338 338 msgid "SUN4V-8000-MY.description"
339 339 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
340 340 msgid "SUN4V-8000-MY.response"
341 341 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
342 342 msgid "SUN4V-8000-MY.impact"
343 343 msgstr "System performance is likely to be affected. \n"
344 344 msgid "SUN4V-8000-MY.action"
345 345 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
346 346 #
347 347 # code: SUN4V-8000-N3
348 348 # keys: fault.cpu.ultraSPARC-T2.dcache
349 349 #
350 350 msgid "SUN4V-8000-N3.type"
351 351 msgstr "Fault"
352 352 msgid "SUN4V-8000-N3.severity"
353 353 msgstr "Major"
354 354 msgid "SUN4V-8000-N3.description"
355 355 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
356 356 msgid "SUN4V-8000-N3.response"
357 357 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
358 358 msgid "SUN4V-8000-N3.impact"
359 359 msgstr "System performance is likely to be affected. \n"
360 360 msgid "SUN4V-8000-N3.action"
361 361 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
362 362 #
363 363 # code: SUN4V-8000-PH
364 364 # keys: fault.cpu.ultraSPARC-T2.mau
365 365 #
366 366 msgid "SUN4V-8000-PH.type"
367 367 msgstr "Fault"
368 368 msgid "SUN4V-8000-PH.severity"
369 369 msgstr "Major"
370 370 msgid "SUN4V-8000-PH.description"
371 371 msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n Refer to %s for more information."
372 372 msgid "SUN4V-8000-PH.response"
373 373 msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
374 374 msgid "SUN4V-8000-PH.impact"
375 375 msgstr "System performance is likely to be affected. \n"
376 376 msgid "SUN4V-8000-PH.action"
377 377 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
378 378 #
379 379 # code: SUN4V-8000-QD
380 380 # keys: fault.cpu.ultraSPARC-T2.l2data-c
381 381 #
382 382 msgid "SUN4V-8000-QD.type"
383 383 msgstr "Fault"
384 384 msgid "SUN4V-8000-QD.severity"
385 385 msgstr "Critical"
386 386 msgid "SUN4V-8000-QD.description"
387 387 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information."
388 388 msgid "SUN4V-8000-QD.response"
389 389 msgstr "No automated response.\n"
390 390 msgid "SUN4V-8000-QD.impact"
391 391 msgstr "System performance is likely to be affected. \n"
392 392 msgid "SUN4V-8000-QD.action"
393 393 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
394 394 #
395 395 # code: SUN4V-8000-R4
396 396 # keys: fault.cpu.ultraSPARC-T2.l2cachetag
397 397 #
398 398 msgid "SUN4V-8000-R4.type"
399 399 msgstr "Fault"
400 400 msgid "SUN4V-8000-R4.severity"
401 401 msgstr "Critical"
402 402 msgid "SUN4V-8000-R4.description"
403 403 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information."
404 404 msgid "SUN4V-8000-R4.response"
405 405 msgstr "No automated response.\n"
406 406 msgid "SUN4V-8000-R4.impact"
407 407 msgstr "System performance is likely to be affected. \n"
408 408 msgid "SUN4V-8000-R4.action"
409 409 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
410 410 #
411 411 # code: SUN4V-8000-SR
412 412 # keys: fault.cpu.ultraSPARC-T2.l2cachectl
413 413 #
414 414 msgid "SUN4V-8000-SR.type"
415 415 msgstr "Fault"
416 416 msgid "SUN4V-8000-SR.severity"
417 417 msgstr "Critical"
418 418 msgid "SUN4V-8000-SR.description"
419 419 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information."
420 420 msgid "SUN4V-8000-SR.response"
421 421 msgstr "No automated response.\n"
422 422 msgid "SUN4V-8000-SR.impact"
423 423 msgstr "System performance is likely to be affected. System may be unstable.\n"
424 424 msgid "SUN4V-8000-SR.action"
425 425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
426 426 #
427 427 # code: SUN4V-8000-TC
428 428 # keys: fault.memory.link-u
429 429 #
430 430 msgid "SUN4V-8000-TC.type"
|
↓ open down ↓ |
171 lines elided |
↑ open up ↑ |
431 431 msgstr "Fault"
432 432 msgid "SUN4V-8000-TC.severity"
433 433 msgstr "Critical"
434 434 msgid "SUN4V-8000-TC.description"
435 435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
436 436 msgid "SUN4V-8000-TC.response"
437 437 msgstr "No automated response.\n"
438 438 msgid "SUN4V-8000-TC.impact"
439 439 msgstr "System performance may be impacted.\n"
440 440 msgid "SUN4V-8000-TC.action"
441 -msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n"
441 +msgstr "At a convenient time, try reseating the memory module. If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
442 442 #
443 443 # code: SUN4V-8000-UQ
444 444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
445 445 #
446 446 msgid "SUN4V-8000-UQ.type"
447 447 msgstr "Fault"
448 448 msgid "SUN4V-8000-UQ.severity"
449 449 msgstr "Critical"
450 450 msgid "SUN4V-8000-UQ.description"
451 451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
452 452 msgid "SUN4V-8000-UQ.response"
453 453 msgstr "No automated response.\n"
454 454 msgid "SUN4V-8000-UQ.impact"
455 455 msgstr "System performance is likely to be affected. \n"
456 456 msgid "SUN4V-8000-UQ.action"
457 457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
458 458 #
459 459 # code: SUN4V-8000-VE
460 460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
461 461 #
462 462 msgid "SUN4V-8000-VE.type"
463 463 msgstr "Fault"
464 464 msgid "SUN4V-8000-VE.severity"
465 465 msgstr "Critical"
466 466 msgid "SUN4V-8000-VE.description"
467 467 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information."
468 468 msgid "SUN4V-8000-VE.response"
469 469 msgstr "No automated response.\n"
470 470 msgid "SUN4V-8000-VE.impact"
471 471 msgstr "System performance is likely to be affected. \n"
472 472 msgid "SUN4V-8000-VE.action"
473 473 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
474 474 #
475 475 # code: SUN4V-8000-WJ
476 476 # keys: fault.cpu.ultraSPARC-T1.l2data-u
477 477 #
478 478 msgid "SUN4V-8000-WJ.type"
479 479 msgstr "Fault"
480 480 msgid "SUN4V-8000-WJ.severity"
481 481 msgstr "Critical"
482 482 msgid "SUN4V-8000-WJ.description"
483 483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
484 484 msgid "SUN4V-8000-WJ.response"
485 485 msgstr "No automated response.\n"
486 486 msgid "SUN4V-8000-WJ.impact"
487 487 msgstr "System performance is likely to be affected. \n"
488 488 msgid "SUN4V-8000-WJ.action"
489 489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
490 490 #
|
↓ open down ↓ |
39 lines elided |
↑ open up ↑ |
491 491 # code: SUN4V-8000-X2
492 492 # keys: fault.memory.datapath
493 493 #
494 494 msgid "SUN4V-8000-X2.type"
495 495 msgstr "Fault"
496 496 msgid "SUN4V-8000-X2.severity"
497 497 msgstr "Major"
498 498 msgid "SUN4V-8000-X2.description"
499 499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information."
500 500 msgid "SUN4V-8000-X2.response"
501 -msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
501 +msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n"
502 502 msgid "SUN4V-8000-X2.impact"
503 503 msgstr "System performance and stability may be affected. \n"
504 504 msgid "SUN4V-8000-X2.action"
505 505 msgstr "Contact your service provider for further diagnosis.\n"
506 506 #
507 507 # code: SUN4V-8000-YX
508 508 # keys: fault.io.n2.ncu
509 509 #
510 510 msgid "SUN4V-8000-YX.type"
511 511 msgstr "Fault"
512 512 msgid "SUN4V-8000-YX.severity"
513 513 msgstr "Critical"
514 514 msgid "SUN4V-8000-YX.description"
515 515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information."
516 516 msgid "SUN4V-8000-YX.response"
517 517 msgstr "One or more device instances may be disabled\n"
518 518 msgid "SUN4V-8000-YX.impact"
519 519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
520 520 msgid "SUN4V-8000-YX.action"
521 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
521 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n"
522 522 #
523 523 # code: SUN4V-8001-02
524 524 # keys: fault.io.n2.dmu
525 525 #
526 526 msgid "SUN4V-8001-02.type"
527 527 msgstr "Fault"
528 528 msgid "SUN4V-8001-02.severity"
529 529 msgstr "Critical"
530 530 msgid "SUN4V-8001-02.description"
531 531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information."
532 532 msgid "SUN4V-8001-02.response"
533 533 msgstr "One or more device instances may be disabled\n"
534 534 msgid "SUN4V-8001-02.impact"
535 535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
536 536 msgid "SUN4V-8001-02.action"
537 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
537 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
538 538 #
539 539 # code: SUN4V-8001-1X
540 540 # keys: fault.io.n2.niu
541 541 #
542 542 msgid "SUN4V-8001-1X.type"
543 543 msgstr "Fault"
544 544 msgid "SUN4V-8001-1X.severity"
545 545 msgstr "Critical"
546 546 msgid "SUN4V-8001-1X.description"
547 547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information."
548 548 msgid "SUN4V-8001-1X.response"
549 549 msgstr "One or more device instances may be disabled\n"
550 550 msgid "SUN4V-8001-1X.impact"
551 551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
552 552 msgid "SUN4V-8001-1X.action"
553 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
553 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
554 554 #
555 555 # code: SUN4V-8001-2E
556 556 # keys: fault.io.n2.siu
557 557 #
558 558 msgid "SUN4V-8001-2E.type"
559 559 msgstr "Fault"
560 560 msgid "SUN4V-8001-2E.severity"
561 561 msgstr "Critical"
562 562 msgid "SUN4V-8001-2E.description"
563 563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information."
564 564 msgid "SUN4V-8001-2E.response"
565 565 msgstr "One or more device instances may be disabled\n"
566 566 msgid "SUN4V-8001-2E.impact"
567 567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
568 568 msgid "SUN4V-8001-2E.action"
569 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
569 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
570 570 #
571 571 # code: SUN4V-8001-3J
572 572 # keys: fault.io.n2.soc
573 573 #
574 574 msgid "SUN4V-8001-3J.type"
575 575 msgstr "Fault"
576 576 msgid "SUN4V-8001-3J.severity"
577 577 msgstr "Critical"
578 578 msgid "SUN4V-8001-3J.description"
579 579 msgstr "A problem was detected in N2's SOC\n Refer to %s for more information."
580 580 msgid "SUN4V-8001-3J.response"
581 581 msgstr "One or more device instances may be disabled\n"
582 582 msgid "SUN4V-8001-3J.impact"
583 583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
584 584 msgid "SUN4V-8001-3J.action"
585 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
585 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
586 586 #
587 587 # code: SUN4V-8001-4C
588 588 # keys: fault.io.n2.crossbar
589 589 #
590 590 msgid "SUN4V-8001-4C.type"
591 591 msgstr "Fault"
592 592 msgid "SUN4V-8001-4C.severity"
593 593 msgstr "Critical"
594 594 msgid "SUN4V-8001-4C.description"
595 595 msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information."
596 596 msgid "SUN4V-8001-4C.response"
597 597 msgstr "One or more device instances may be disabled\n"
598 598 msgid "SUN4V-8001-4C.impact"
599 599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
600 600 msgid "SUN4V-8001-4C.action"
601 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
601 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
602 602 #
603 603 # code: SUN4V-8001-5Q
604 604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
605 605 #
606 606 msgid "SUN4V-8001-5Q.type"
607 607 msgstr "Fault"
608 608 msgid "SUN4V-8001-5Q.severity"
609 609 msgstr "Critical"
610 610 msgid "SUN4V-8001-5Q.description"
611 611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n Refer to %s for more information."
612 612 msgid "SUN4V-8001-5Q.response"
613 613 msgstr "One or more device instances may be disabled\n"
614 614 msgid "SUN4V-8001-5Q.impact"
615 615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
616 616 msgid "SUN4V-8001-5Q.action"
617 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
617 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
618 618 #
619 619 # code: SUN4V-8001-64
620 620 # keys: fault.io.vf.ncx
621 621 #
622 622 msgid "SUN4V-8001-64.type"
623 623 msgstr "Fault"
624 624 msgid "SUN4V-8001-64.severity"
625 625 msgstr "Critical"
626 626 msgid "SUN4V-8001-64.description"
627 627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n Refer to %s for more information."
628 628 msgid "SUN4V-8001-64.response"
629 629 msgstr "One or more device instances may be disabled\n"
630 630 msgid "SUN4V-8001-64.impact"
631 631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
632 632 msgid "SUN4V-8001-64.action"
633 -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
633 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
634 634 #
635 635 # code: SUN4V-8001-7R
636 636 # keys: fault.memory.link-f
637 637 #
638 638 msgid "SUN4V-8001-7R.type"
639 639 msgstr "Fault"
640 640 msgid "SUN4V-8001-7R.severity"
641 641 msgstr "Major"
642 642 msgid "SUN4V-8001-7R.description"
643 643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. A lane failover has taken place.\n Refer to %s for more information."
644 644 msgid "SUN4V-8001-7R.response"
645 645 msgstr "No automated response.\n"
646 646 msgid "SUN4V-8001-7R.impact"
647 647 msgstr "System performance may be impacted.\n"
648 648 msgid "SUN4V-8001-7R.action"
649 -msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n"
649 +msgstr "At a convenient time, try reseating the memory module(s). If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
650 650 #
651 651 # code: SUN4V-8001-8H
652 652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
653 653 #
654 654 msgid "SUN4V-8001-8H.type"
655 655 msgstr "Fault"
656 656 msgid "SUN4V-8001-8H.severity"
657 657 msgstr "Minor"
658 658 msgid "SUN4V-8001-8H.description"
659 659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
660 660 msgid "SUN4V-8001-8H.response"
661 661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
662 662 msgid "SUN4V-8001-8H.impact"
663 663 msgstr "System performance may be affected. \n"
664 664 msgid "SUN4V-8001-8H.action"
665 665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
666 666 #
667 667 # code: SUN4V-8001-9D
668 668 # keys: fault.cpu.ultraSPARC-T2plus.freg
669 669 #
670 670 msgid "SUN4V-8001-9D.type"
671 671 msgstr "Fault"
672 672 msgid "SUN4V-8001-9D.severity"
673 673 msgstr "Minor"
674 674 msgid "SUN4V-8001-9D.description"
675 675 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
676 676 msgid "SUN4V-8001-9D.response"
677 677 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
678 678 msgid "SUN4V-8001-9D.impact"
679 679 msgstr "System performance may be affected. \n"
680 680 msgid "SUN4V-8001-9D.action"
681 681 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
682 682 #
683 683 # code: SUN4V-8001-AY
684 684 # keys: fault.cpu.ultraSPARC-T2plus.misc_reg
685 685 #
686 686 msgid "SUN4V-8001-AY.type"
687 687 msgstr "Fault"
688 688 msgid "SUN4V-8001-AY.severity"
689 689 msgstr "Minor"
690 690 msgid "SUN4V-8001-AY.description"
691 691 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
692 692 msgid "SUN4V-8001-AY.response"
693 693 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
694 694 msgid "SUN4V-8001-AY.impact"
695 695 msgstr "System performance may be affected. \n"
696 696 msgid "SUN4V-8001-AY.action"
697 697 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
698 698 #
699 699 # code: SUN4V-8001-C3
700 700 # keys: fault.cpu.ultraSPARC-T2plus.itlb
701 701 #
702 702 msgid "SUN4V-8001-C3.type"
703 703 msgstr "Fault"
704 704 msgid "SUN4V-8001-C3.severity"
705 705 msgstr "Major"
706 706 msgid "SUN4V-8001-C3.description"
707 707 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
708 708 msgid "SUN4V-8001-C3.response"
709 709 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
710 710 msgid "SUN4V-8001-C3.impact"
711 711 msgstr "System performance is likely to be affected. \n"
712 712 msgid "SUN4V-8001-C3.action"
713 713 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
714 714 #
715 715 # code: SUN4V-8001-DS
716 716 # keys: fault.cpu.ultraSPARC-T2plus.dtlb
717 717 #
718 718 msgid "SUN4V-8001-DS.type"
719 719 msgstr "Fault"
720 720 msgid "SUN4V-8001-DS.severity"
721 721 msgstr "Major"
722 722 msgid "SUN4V-8001-DS.description"
723 723 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
724 724 msgid "SUN4V-8001-DS.response"
725 725 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
726 726 msgid "SUN4V-8001-DS.impact"
727 727 msgstr "System performance is likely to be affected. \n"
728 728 msgid "SUN4V-8001-DS.action"
729 729 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
730 730 #
731 731 # code: SUN4V-8001-E5
732 732 # keys: fault.cpu.ultraSPARC-T2plus.icache
733 733 #
734 734 msgid "SUN4V-8001-E5.type"
735 735 msgstr "Fault"
736 736 msgid "SUN4V-8001-E5.severity"
737 737 msgstr "Major"
738 738 msgid "SUN4V-8001-E5.description"
739 739 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
740 740 msgid "SUN4V-8001-E5.response"
741 741 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
742 742 msgid "SUN4V-8001-E5.impact"
743 743 msgstr "System performance is likely to be affected. \n"
744 744 msgid "SUN4V-8001-E5.action"
745 745 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
746 746 #
747 747 # code: SUN4V-8001-FP
748 748 # keys: fault.cpu.ultraSPARC-T2plus.dcache
749 749 #
750 750 msgid "SUN4V-8001-FP.type"
751 751 msgstr "Fault"
752 752 msgid "SUN4V-8001-FP.severity"
753 753 msgstr "Major"
754 754 msgid "SUN4V-8001-FP.description"
755 755 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
756 756 msgid "SUN4V-8001-FP.response"
757 757 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
758 758 msgid "SUN4V-8001-FP.impact"
759 759 msgstr "System performance is likely to be affected. \n"
760 760 msgid "SUN4V-8001-FP.action"
761 761 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
762 762 #
763 763 # code: SUN4V-8001-GA
764 764 # keys: fault.cpu.ultraSPARC-T2plus.mau
765 765 #
766 766 msgid "SUN4V-8001-GA.type"
767 767 msgstr "Fault"
768 768 msgid "SUN4V-8001-GA.severity"
769 769 msgstr "Major"
770 770 msgid "SUN4V-8001-GA.description"
771 771 msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
772 772 msgid "SUN4V-8001-GA.response"
773 773 msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
774 774 msgid "SUN4V-8001-GA.impact"
775 775 msgstr "System performance is likely to be affected. \n"
776 776 msgid "SUN4V-8001-GA.action"
777 777 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
778 778 #
779 779 # code: SUN4V-8001-HJ
780 780 # keys: fault.cpu.ultraSPARC-T2plus.l2data-c
781 781 #
782 782 msgid "SUN4V-8001-HJ.type"
783 783 msgstr "Fault"
784 784 msgid "SUN4V-8001-HJ.severity"
785 785 msgstr "Critical"
786 786 msgid "SUN4V-8001-HJ.description"
787 787 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information."
788 788 msgid "SUN4V-8001-HJ.response"
789 789 msgstr "No automated response.\n"
790 790 msgid "SUN4V-8001-HJ.impact"
791 791 msgstr "System performance is likely to be affected. \n"
792 792 msgid "SUN4V-8001-HJ.action"
793 793 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
794 794 #
795 795 # code: SUN4V-8001-JE
796 796 # keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
797 797 #
798 798 msgid "SUN4V-8001-JE.type"
799 799 msgstr "Fault"
800 800 msgid "SUN4V-8001-JE.severity"
801 801 msgstr "Critical"
802 802 msgid "SUN4V-8001-JE.description"
803 803 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information."
804 804 msgid "SUN4V-8001-JE.response"
805 805 msgstr "No automated response.\n"
806 806 msgid "SUN4V-8001-JE.impact"
807 807 msgstr "System performance is likely to be affected. \n"
808 808 msgid "SUN4V-8001-JE.action"
809 809 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
810 810 #
811 811 # code: SUN4V-8001-KX
812 812 # keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
813 813 #
814 814 msgid "SUN4V-8001-KX.type"
815 815 msgstr "Fault"
816 816 msgid "SUN4V-8001-KX.severity"
817 817 msgstr "Critical"
818 818 msgid "SUN4V-8001-KX.description"
819 819 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information."
820 820 msgid "SUN4V-8001-KX.response"
821 821 msgstr "No automated response.\n"
822 822 msgid "SUN4V-8001-KX.impact"
823 823 msgstr "System performance is likely to be affected. System may be unstable.\n"
824 824 msgid "SUN4V-8001-KX.action"
825 825 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
826 826 #
827 827 # code: SUN4V-8001-L2
828 828 # keys: fault.cpu.ultraSPARC-T2plus.l2data-u
829 829 #
830 830 msgid "SUN4V-8001-L2.type"
831 831 msgstr "Fault"
832 832 msgid "SUN4V-8001-L2.severity"
833 833 msgstr "Critical"
834 834 msgid "SUN4V-8001-L2.description"
835 835 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
836 836 msgid "SUN4V-8001-L2.response"
837 837 msgstr "No automated response.\n"
838 838 msgid "SUN4V-8001-L2.impact"
839 839 msgstr "System performance is likely to be affected. \n"
840 840 msgid "SUN4V-8001-L2.action"
841 841 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
842 842 #
843 843 # code: SUN4V-8001-MR
844 844 # keys: fault.cpu.ultraSPARC-T2plus.lfu-f
845 845 #
846 846 msgid "SUN4V-8001-MR.type"
847 847 msgstr "Fault"
848 848 msgid "SUN4V-8001-MR.severity"
849 849 msgstr "Major"
850 850 msgid "SUN4V-8001-MR.description"
851 851 msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n Refer to %s for more information."
852 852 msgid "SUN4V-8001-MR.response"
853 853 msgstr "No other automated response.\n"
854 854 msgid "SUN4V-8001-MR.impact"
855 855 msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
856 856 msgid "SUN4V-8001-MR.action"
857 857 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
858 858 #
859 859 # code: SUN4V-8001-N4
860 860 # keys: fault.cpu.ultraSPARC-T2plus.lfu-p
861 861 #
862 862 msgid "SUN4V-8001-N4.type"
863 863 msgstr "Fault"
864 864 msgid "SUN4V-8001-N4.severity"
865 865 msgstr "Major"
866 866 msgid "SUN4V-8001-N4.description"
867 867 msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n Refer to %s for more information."
868 868 msgid "SUN4V-8001-N4.response"
869 869 msgstr "No automated response.\n"
870 870 msgid "SUN4V-8001-N4.impact"
871 871 msgstr "The system has most likely taken a fatal reset.\n"
872 872 msgid "SUN4V-8001-N4.action"
873 873 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
874 874 #
875 875 # code: SUN4V-8001-PQ
876 876 # keys: fault.cpu.ultraSPARC-T2plus.lfu-u
877 877 #
878 878 msgid "SUN4V-8001-PQ.type"
879 879 msgstr "Fault"
880 880 msgid "SUN4V-8001-PQ.severity"
881 881 msgstr "Major"
882 882 msgid "SUN4V-8001-PQ.description"
883 883 msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n Refer to %s for more information."
884 884 msgid "SUN4V-8001-PQ.response"
885 885 msgstr "No automated response.\n"
886 886 msgid "SUN4V-8001-PQ.impact"
887 887 msgstr "The system's integrity is seriously compromised.\n"
888 888 msgid "SUN4V-8001-PQ.action"
889 889 msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
890 890 #
891 891 # code: SUN4V-8001-QC
892 892 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
893 893 #
894 894 msgid "SUN4V-8001-QC.type"
895 895 msgstr "Fault"
896 896 msgid "SUN4V-8001-QC.severity"
897 897 msgstr "Critical"
898 898 msgid "SUN4V-8001-QC.description"
899 899 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n Refer to %s for more information."
900 900 msgid "SUN4V-8001-QC.response"
901 901 msgstr "No automated reponse.\n"
902 902 msgid "SUN4V-8001-QC.impact"
903 903 msgstr "The system's integrity is compromised.\n"
904 904 msgid "SUN4V-8001-QC.action"
905 905 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
906 906 #
907 907 # code: SUN4V-8001-R3
908 908 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
909 909 #
910 910 msgid "SUN4V-8001-R3.type"
911 911 msgstr "Fault"
912 912 msgid "SUN4V-8001-R3.severity"
913 913 msgstr "Major"
914 914 msgid "SUN4V-8001-R3.description"
915 915 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n Refer to %s for more information."
916 916 msgid "SUN4V-8001-R3.response"
917 917 msgstr "No automated reponse.\n"
918 918 msgid "SUN4V-8001-R3.impact"
919 919 msgstr "The system's integrity is compromised.\n"
920 920 msgid "SUN4V-8001-R3.action"
921 921 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
922 922 #
923 923 # code: SUN4V-8001-SY
924 924 # keys: fault.cpu.ultraSPARC-T2plus.chip
925 925 #
926 926 msgid "SUN4V-8001-SY.type"
927 927 msgstr "Fault"
928 928 msgid "SUN4V-8001-SY.severity"
929 929 msgstr "Critical"
930 930 msgid "SUN4V-8001-SY.description"
931 931 msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n Refer to %s for more information."
932 932 msgid "SUN4V-8001-SY.response"
933 933 msgstr "No automated reponse.\n"
934 934 msgid "SUN4V-8001-SY.impact"
935 935 msgstr "The system's integrity is seriously compromised.\n"
936 936 msgid "SUN4V-8001-SY.action"
937 937 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
938 938 #
939 939 # code: SUN4V-8001-TD
940 940 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
941 941 #
942 942 msgid "SUN4V-8001-TD.type"
943 943 msgstr "Fault"
944 944 msgid "SUN4V-8001-TD.severity"
945 945 msgstr "Minor"
946 946 msgid "SUN4V-8001-TD.description"
947 947 msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n Refer to %s for more information."
948 948 msgid "SUN4V-8001-TD.response"
949 949 msgstr "No automated reponse.\n"
950 950 msgid "SUN4V-8001-TD.impact"
951 951 msgstr "The system's integrity is seriously compromised.\n"
952 952 msgid "SUN4V-8001-TD.action"
953 953 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
954 954 #
955 955 # code: SUN4V-8001-UH
956 956 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
957 957 #
958 958 msgid "SUN4V-8001-UH.type"
959 959 msgstr "Fault"
960 960 msgid "SUN4V-8001-UH.severity"
961 961 msgstr "Major"
962 962 msgid "SUN4V-8001-UH.description"
963 963 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n Refer to %s for more information."
964 964 msgid "SUN4V-8001-UH.response"
965 965 msgstr "No automated reponse.\n"
966 966 msgid "SUN4V-8001-UH.impact"
967 967 msgstr "The system's performance may be impacted.\n"
968 968 msgid "SUN4V-8001-UH.action"
969 969 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
970 970 #
971 971 # code: SUN4V-8001-VA
972 972 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
973 973 #
974 974 msgid "SUN4V-8001-VA.type"
975 975 msgstr "Fault"
976 976 msgid "SUN4V-8001-VA.severity"
977 977 msgstr "Critical"
978 978 msgid "SUN4V-8001-VA.description"
979 979 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n Refer to %s for more information."
980 980 msgid "SUN4V-8001-VA.response"
981 981 msgstr "No automated reponse.\n"
982 982 msgid "SUN4V-8001-VA.impact"
983 983 msgstr "The system's integrity is seriously compromised.\n"
984 984 msgid "SUN4V-8001-VA.action"
985 985 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
986 986 #
987 987 # code: SUN4V-8001-WP
988 988 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
989 989 #
990 990 msgid "SUN4V-8001-WP.type"
991 991 msgstr "Fault"
992 992 msgid "SUN4V-8001-WP.severity"
993 993 msgstr "Critical"
994 994 msgid "SUN4V-8001-WP.description"
995 995 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n Refer to %s for more information."
996 996 msgid "SUN4V-8001-WP.response"
997 997 msgstr "No automated reponse.\n"
998 998 msgid "SUN4V-8001-WP.impact"
999 999 msgstr "The system's integrity is seriously compromised.\n"
1000 1000 msgid "SUN4V-8001-WP.action"
1001 1001 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1002 1002 #
1003 1003 # code: SUN4V-8001-X5
1004 1004 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
1005 1005 #
1006 1006 msgid "SUN4V-8001-X5.type"
1007 1007 msgstr "Fault"
1008 1008 msgid "SUN4V-8001-X5.severity"
1009 1009 msgstr "Critical"
1010 1010 msgid "SUN4V-8001-X5.description"
1011 1011 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n Refer to %s for more information."
1012 1012 msgid "SUN4V-8001-X5.response"
1013 1013 msgstr "No automated reponse.\n"
1014 1014 msgid "SUN4V-8001-X5.impact"
1015 1015 msgstr "The system's performance may be compromised.\n"
1016 1016 msgid "SUN4V-8001-X5.action"
1017 1017 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1018 1018 #
1019 1019 # code: SUN4V-8001-YS
1020 1020 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
1021 1021 #
1022 1022 msgid "SUN4V-8001-YS.type"
1023 1023 msgstr "Fault"
1024 1024 msgid "SUN4V-8001-YS.severity"
1025 1025 msgstr "Major"
1026 1026 msgid "SUN4V-8001-YS.description"
1027 1027 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n Refer to %s for more information."
1028 1028 msgid "SUN4V-8001-YS.response"
1029 1029 msgstr "No automated reponse.\n"
1030 1030 msgid "SUN4V-8001-YS.impact"
1031 1031 msgstr "The system's integrity may be seriously compromised.\n"
1032 1032 msgid "SUN4V-8001-YS.action"
1033 1033 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1034 1034 #
1035 1035 # code: SUN4V-8002-0C
1036 1036 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1037 1037 #
1038 1038 msgid "SUN4V-8002-0C.type"
1039 1039 msgstr "Fault"
1040 1040 msgid "SUN4V-8002-0C.severity"
1041 1041 msgstr "Major"
1042 1042 msgid "SUN4V-8002-0C.description"
1043 1043 msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n Refer to %s for more information."
1044 1044 msgid "SUN4V-8002-0C.response"
1045 1045 msgstr "No automated reponse.\n"
1046 1046 msgid "SUN4V-8002-0C.impact"
1047 1047 msgstr "The system's performance may be impacted.\n"
1048 1048 msgid "SUN4V-8002-0C.action"
1049 1049 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1050 1050 #
1051 1051 # code: SUN4V-8002-1Q
1052 1052 # keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1053 1053 #
1054 1054 msgid "SUN4V-8002-1Q.type"
1055 1055 msgstr "Fault"
1056 1056 msgid "SUN4V-8002-1Q.severity"
1057 1057 msgstr "Major"
1058 1058 msgid "SUN4V-8002-1Q.description"
1059 1059 msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n Refer to %s for more information."
1060 1060 msgid "SUN4V-8002-1Q.response"
1061 1061 msgstr "No automated reponse.\n"
1062 1062 msgid "SUN4V-8002-1Q.impact"
1063 1063 msgstr "The system's performance may be impacted.\n"
1064 1064 msgid "SUN4V-8002-1Q.action"
1065 1065 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1066 1066 #
1067 1067 # code: SUN4V-8002-24
1068 1068 # keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
1069 1069 #
1070 1070 msgid "SUN4V-8002-24.type"
1071 1071 msgstr "Fault"
1072 1072 msgid "SUN4V-8002-24.severity"
1073 1073 msgstr "Critical"
1074 1074 msgid "SUN4V-8002-24.description"
1075 1075 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n Refer to %s for more information."
1076 1076 msgid "SUN4V-8002-24.response"
1077 1077 msgstr "No automated reponse.\n"
1078 1078 msgid "SUN4V-8002-24.impact"
1079 1079 msgstr "The system's integrity is seriously compromised.\n"
1080 1080 msgid "SUN4V-8002-24.action"
1081 1081 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1082 1082 #
1083 1083 # code: SUN4V-8002-3R
1084 1084 # keys: fault.memory.dimm-page-retires-excessive
1085 1085 #
1086 1086 msgid "SUN4V-8002-3R.type"
1087 1087 msgstr "Fault"
1088 1088 msgid "SUN4V-8002-3R.severity"
1089 1089 msgstr "Major"
1090 1090 msgid "SUN4V-8002-3R.description"
1091 1091 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n Refer to %s for more information."
1092 1092 msgid "SUN4V-8002-3R.response"
1093 1093 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
1094 1094 msgid "SUN4V-8002-3R.impact"
1095 1095 msgstr "Total system memory capacity has been reduced.\n"
1096 1096 msgid "SUN4V-8002-3R.action"
1097 1097 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1098 1098 #
1099 1099 # code: SUN4V-8002-42
1100 1100 # keys: fault.memory.dimm-ue-imminent
1101 1101 #
1102 1102 msgid "SUN4V-8002-42.type"
1103 1103 msgstr "Fault"
1104 1104 msgid "SUN4V-8002-42.severity"
1105 1105 msgstr "Critical"
1106 1106 msgid "SUN4V-8002-42.description"
1107 1107 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information."
1108 1108 msgid "SUN4V-8002-42.response"
1109 1109 msgstr "None at this time.\n"
1110 1110 msgid "SUN4V-8002-42.impact"
1111 1111 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1112 1112 msgid "SUN4V-8002-42.action"
1113 1113 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1114 1114 #
1115 1115 # code: SUN4V-8002-5X
1116 1116 # keys: fault.memory.dram-ue-imminent
1117 1117 #
1118 1118 msgid "SUN4V-8002-5X.type"
1119 1119 msgstr "Fault"
1120 1120 msgid "SUN4V-8002-5X.severity"
1121 1121 msgstr "Critical"
1122 1122 msgid "SUN4V-8002-5X.description"
1123 1123 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information."
1124 1124 msgid "SUN4V-8002-5X.response"
1125 1125 msgstr "None at this time.\n"
1126 1126 msgid "SUN4V-8002-5X.impact"
1127 1127 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1128 1128 msgid "SUN4V-8002-5X.action"
1129 1129 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1130 1130 #
1131 1131 # code: SUN4V-8002-6E
1132 1132 # keys: fault.cpu.generic-sparc.strand
1133 1133 #
1134 1134 msgid "SUN4V-8002-6E.type"
1135 1135 msgstr "Fault"
1136 1136 msgid "SUN4V-8002-6E.severity"
1137 1137 msgstr "Major"
1138 1138 msgid "SUN4V-8002-6E.description"
1139 1139 msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n Refer to %s for more information."
1140 1140 msgid "SUN4V-8002-6E.response"
1141 1141 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1142 1142 msgid "SUN4V-8002-6E.impact"
1143 1143 msgstr "System performance may be affected. \n"
1144 1144 msgid "SUN4V-8002-6E.action"
1145 1145 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1146 1146 #
1147 1147 # code: SUN4V-8002-7J
1148 1148 # keys: fault.cpu.generic-sparc.strand-nr
1149 1149 #
1150 1150 msgid "SUN4V-8002-7J.type"
1151 1151 msgstr "Fault"
1152 1152 msgid "SUN4V-8002-7J.severity"
1153 1153 msgstr "Major"
1154 1154 msgid "SUN4V-8002-7J.description"
1155 1155 msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n Refer to %s for more information."
1156 1156 msgid "SUN4V-8002-7J.response"
1157 1157 msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n"
1158 1158 msgid "SUN4V-8002-7J.impact"
1159 1159 msgstr "System performance may be affected. \n"
1160 1160 msgid "SUN4V-8002-7J.action"
1161 1161 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1162 1162 #
1163 1163 # code: SUN4V-8002-8S
1164 1164 # keys: fault.cpu.generic-sparc.strand-uc
1165 1165 #
1166 1166 msgid "SUN4V-8002-8S.type"
1167 1167 msgstr "Fault"
1168 1168 msgid "SUN4V-8002-8S.severity"
1169 1169 msgstr "Critical"
1170 1170 msgid "SUN4V-8002-8S.description"
1171 1171 msgstr "This strand has encountered an uncorrectable error.\n Refer to %s for more information."
1172 1172 msgid "SUN4V-8002-8S.response"
1173 1173 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1174 1174 msgid "SUN4V-8002-8S.impact"
1175 1175 msgstr "System performance may be affected. \n"
1176 1176 msgid "SUN4V-8002-8S.action"
1177 1177 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1178 1178 #
1179 1179 # code: SUN4V-8002-95
1180 1180 # keys: fault.cpu.generic-sparc.strand-uc-nr
1181 1181 #
1182 1182 msgid "SUN4V-8002-95.type"
1183 1183 msgstr "Fault"
1184 1184 msgid "SUN4V-8002-95.severity"
1185 1185 msgstr "Critical"
1186 1186 msgid "SUN4V-8002-95.description"
1187 1187 msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n Refer to %s for more information."
1188 1188 msgid "SUN4V-8002-95.response"
1189 1189 msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n"
1190 1190 msgid "SUN4V-8002-95.impact"
1191 1191 msgstr "System performance may be affected. \n"
1192 1192 msgid "SUN4V-8002-95.action"
1193 1193 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1194 1194 #
1195 1195 # code: SUN4V-8002-AP
1196 1196 # keys: fault.cpu.generic-sparc.core
1197 1197 #
1198 1198 msgid "SUN4V-8002-AP.type"
1199 1199 msgstr "Fault"
1200 1200 msgid "SUN4V-8002-AP.severity"
1201 1201 msgstr "Major"
1202 1202 msgid "SUN4V-8002-AP.description"
1203 1203 msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n Refer to %s for more information."
1204 1204 msgid "SUN4V-8002-AP.response"
1205 1205 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1206 1206 msgid "SUN4V-8002-AP.impact"
1207 1207 msgstr "System performance may be affected. \n"
1208 1208 msgid "SUN4V-8002-AP.action"
1209 1209 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1210 1210 #
1211 1211 # code: SUN4V-8002-CA
1212 1212 # keys: fault.cpu.generic-sparc.core-nr
1213 1213 #
1214 1214 msgid "SUN4V-8002-CA.type"
1215 1215 msgstr "Fault"
1216 1216 msgid "SUN4V-8002-CA.severity"
1217 1217 msgstr "Major"
1218 1218 msgid "SUN4V-8002-CA.description"
1219 1219 msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n Refer to %s for more information."
1220 1220 msgid "SUN4V-8002-CA.response"
1221 1221 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1222 1222 msgid "SUN4V-8002-CA.impact"
1223 1223 msgstr "System performance may be affected. \n"
1224 1224 msgid "SUN4V-8002-CA.action"
1225 1225 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1226 1226 #
1227 1227 # code: SUN4V-8002-DH
1228 1228 # keys: fault.cpu.generic-sparc.core-uc
1229 1229 #
1230 1230 msgid "SUN4V-8002-DH.type"
1231 1231 msgstr "Fault"
1232 1232 msgid "SUN4V-8002-DH.severity"
1233 1233 msgstr "Critical"
1234 1234 msgid "SUN4V-8002-DH.description"
1235 1235 msgstr "This core has encountered an uncorrectable error.\n Refer to %s for more information."
1236 1236 msgid "SUN4V-8002-DH.response"
1237 1237 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1238 1238 msgid "SUN4V-8002-DH.impact"
1239 1239 msgstr "System performance may be affected. \n"
1240 1240 msgid "SUN4V-8002-DH.action"
1241 1241 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1242 1242 #
1243 1243 # code: SUN4V-8002-ED
1244 1244 # keys: fault.cpu.generic-sparc.core-uc-nr
1245 1245 #
1246 1246 msgid "SUN4V-8002-ED.type"
1247 1247 msgstr "Fault"
1248 1248 msgid "SUN4V-8002-ED.severity"
1249 1249 msgstr "Critical"
1250 1250 msgid "SUN4V-8002-ED.description"
1251 1251 msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n Refer to %s for more information."
1252 1252 msgid "SUN4V-8002-ED.response"
1253 1253 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1254 1254 msgid "SUN4V-8002-ED.impact"
1255 1255 msgstr "System performance may be affected. \n"
1256 1256 msgid "SUN4V-8002-ED.action"
1257 1257 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1258 1258 #
1259 1259 # code: SUN4V-8002-FY
1260 1260 # keys: fault.cpu.generic-sparc.chip
1261 1261 #
1262 1262 msgid "SUN4V-8002-FY.type"
1263 1263 msgstr "Fault"
1264 1264 msgid "SUN4V-8002-FY.severity"
1265 1265 msgstr "Critical"
1266 1266 msgid "SUN4V-8002-FY.description"
1267 1267 msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n Refer to %s for more information."
1268 1268 msgid "SUN4V-8002-FY.response"
1269 1269 msgstr "No automated response.\n"
1270 1270 msgid "SUN4V-8002-FY.impact"
1271 1271 msgstr "System performance may be affected. \n"
1272 1272 msgid "SUN4V-8002-FY.action"
1273 1273 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1274 1274 #
1275 1275 # code: SUN4V-8002-G3
1276 1276 # keys: fault.cpu.generic-sparc.chip-nr
1277 1277 #
1278 1278 msgid "SUN4V-8002-G3.type"
1279 1279 msgstr "Fault"
1280 1280 msgid "SUN4V-8002-G3.severity"
1281 1281 msgstr "Critical"
1282 1282 msgid "SUN4V-8002-G3.description"
1283 1283 msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n Refer to %s for more information."
1284 1284 msgid "SUN4V-8002-G3.response"
1285 1285 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1286 1286 msgid "SUN4V-8002-G3.impact"
1287 1287 msgstr "System performance may be affected. \n"
1288 1288 msgid "SUN4V-8002-G3.action"
1289 1289 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1290 1290 #
1291 1291 # code: SUN4V-8002-HR
1292 1292 # keys: fault.cpu.generic-sparc.chip-uc
1293 1293 #
1294 1294 msgid "SUN4V-8002-HR.type"
1295 1295 msgstr "Fault"
1296 1296 msgid "SUN4V-8002-HR.severity"
1297 1297 msgstr "Critical"
1298 1298 msgid "SUN4V-8002-HR.description"
1299 1299 msgstr "This chip has encountered a chip-level uncorrectable error.\n Refer to %s for more information."
1300 1300 msgid "SUN4V-8002-HR.response"
1301 1301 msgstr "The system will attempt to retire all strands in this chip.\n"
1302 1302 msgid "SUN4V-8002-HR.impact"
1303 1303 msgstr "System performance may be affected. \n"
1304 1304 msgid "SUN4V-8002-HR.action"
1305 1305 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1306 1306 #
1307 1307 # code: SUN4V-8002-J4
1308 1308 # keys: fault.cpu.generic-sparc.chip-uc-nr
1309 1309 #
1310 1310 msgid "SUN4V-8002-J4.type"
1311 1311 msgstr "Fault"
1312 1312 msgid "SUN4V-8002-J4.severity"
1313 1313 msgstr "Critical"
1314 1314 msgid "SUN4V-8002-J4.description"
1315 1315 msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n Refer to %s for more information."
1316 1316 msgid "SUN4V-8002-J4.response"
1317 1317 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1318 1318 msgid "SUN4V-8002-J4.impact"
1319 1319 msgstr "System performance may be affected. \n"
1320 1320 msgid "SUN4V-8002-J4.action"
1321 1321 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1322 1322 #
1323 1323 # code: SUN4V-8002-KQ
1324 1324 # keys: fault.cpu.generic-sparc.c2c
1325 1325 #
1326 1326 msgid "SUN4V-8002-KQ.type"
1327 1327 msgstr "Fault"
1328 1328 msgid "SUN4V-8002-KQ.severity"
1329 1329 msgstr "Major"
1330 1330 msgid "SUN4V-8002-KQ.description"
1331 1331 msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n Refer to %s for more information."
1332 1332 msgid "SUN4V-8002-KQ.response"
1333 1333 msgstr "No automated response.\n"
1334 1334 msgid "SUN4V-8002-KQ.impact"
1335 1335 msgstr "System performance may be affected.\n"
1336 1336 msgid "SUN4V-8002-KQ.action"
1337 1337 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1338 1338 #
1339 1339 # code: SUN4V-8002-LC
1340 1340 # keys: fault.cpu.generic-sparc.c2c-failover
1341 1341 #
1342 1342 msgid "SUN4V-8002-LC.type"
1343 1343 msgstr "Fault"
1344 1344 msgid "SUN4V-8002-LC.severity"
1345 1345 msgstr "Major"
1346 1346 msgid "SUN4V-8002-LC.description"
1347 1347 msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n Refer to %s for more information."
1348 1348 msgid "SUN4V-8002-LC.response"
1349 1349 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1350 1350 msgid "SUN4V-8002-LC.impact"
1351 1351 msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n"
1352 1352 msgid "SUN4V-8002-LC.action"
1353 1353 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1354 1354 #
1355 1355 # code: SUN4V-8002-MJ
1356 1356 # keys: fault.cpu.generic-sparc.c2c-uc
1357 1357 #
1358 1358 msgid "SUN4V-8002-MJ.type"
1359 1359 msgstr "Fault"
1360 1360 msgid "SUN4V-8002-MJ.severity"
1361 1361 msgstr "Critical"
1362 1362 msgid "SUN4V-8002-MJ.description"
1363 1363 msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n Refer to %s for more information."
1364 1364 msgid "SUN4V-8002-MJ.response"
1365 1365 msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n"
1366 1366 msgid "SUN4V-8002-MJ.impact"
1367 1367 msgstr "The system halts and must be restarted. The integrity of this system has\nbeen compromised.\n"
1368 1368 msgid "SUN4V-8002-MJ.action"
1369 1369 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1370 1370 #
1371 1371 # code: SUN4V-8002-NE
1372 1372 # keys: fault.memory.memlink
1373 1373 #
1374 1374 msgid "SUN4V-8002-NE.type"
1375 1375 msgstr "Fault"
1376 1376 msgid "SUN4V-8002-NE.severity"
1377 1377 msgstr "Major"
1378 1378 msgid "SUN4V-8002-NE.description"
1379 1379 msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller. No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n Refer to %s for more information."
1380 1380 msgid "SUN4V-8002-NE.response"
1381 1381 msgstr "The system has recovered from the CRC errors.\n"
1382 1382 msgid "SUN4V-8002-NE.impact"
1383 1383 msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n"
1384 1384 msgid "SUN4V-8002-NE.action"
1385 1385 msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1386 1386 #
1387 1387 # code: SUN4V-8002-PX
1388 1388 # keys: fault.memory.memlink-failover
1389 1389 #
1390 1390 msgid "SUN4V-8002-PX.type"
1391 1391 msgstr "Fault"
1392 1392 msgid "SUN4V-8002-PX.severity"
1393 1393 msgstr "Major"
1394 1394 msgid "SUN4V-8002-PX.description"
1395 1395 msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller. While no data has been lost, a lane failover\nhas taken place.\n Refer to %s for more information."
1396 1396 msgid "SUN4V-8002-PX.response"
1397 1397 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1398 1398 msgid "SUN4V-8002-PX.impact"
1399 1399 msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n"
1400 1400 msgid "SUN4V-8002-PX.action"
1401 1401 msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n"
1402 1402 #
1403 1403 # code: SUN4V-8002-Q2
1404 1404 # keys: fault.memory.memlink-uc
1405 1405 #
1406 1406 msgid "SUN4V-8002-Q2.type"
1407 1407 msgstr "Fault"
1408 1408 msgid "SUN4V-8002-Q2.severity"
1409 1409 msgstr "Critical"
1410 1410 msgid "SUN4V-8002-Q2.description"
1411 1411 msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n Refer to %s for more information."
1412 1412 msgid "SUN4V-8002-Q2.response"
1413 1413 msgstr "The system crashed to prevent data corruption. Memory in the affected\npartition may have been deconfigured. (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n"
1414 1414 msgid "SUN4V-8002-Q2.impact"
1415 1415 msgstr "If memory has been deconfigured, system performance may be impacted. \n"
1416 1416 msgid "SUN4V-8002-Q2.action"
1417 1417 msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n"
1418 1418 #
1419 1419 # code: SUN4V-8002-RA
1420 1420 # keys: defect.fw.generic-sparc.addr-oob
1421 1421 #
1422 1422 msgid "SUN4V-8002-RA.type"
1423 1423 msgstr "Fault"
1424 1424 msgid "SUN4V-8002-RA.severity"
1425 1425 msgstr "Critical"
1426 1426 msgid "SUN4V-8002-RA.description"
1427 1427 msgstr "An address-out-of-bounds error has occurred.\n Refer to %s for more information."
1428 1428 msgid "SUN4V-8002-RA.response"
1429 1429 msgstr "No automated response.\n"
1430 1430 msgid "SUN4V-8002-RA.impact"
1431 1431 msgstr "The system may have taken a fatal reset.\n"
1432 1432 msgid "SUN4V-8002-RA.action"
1433 1433 msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n"
1434 1434 #
1435 1435 # code: SUN4V-8002-SP
1436 1436 # keys: defect.fw.generic-sparc.erpt-gen
1437 1437 #
1438 1438 msgid "SUN4V-8002-SP.type"
1439 1439 msgstr "Fault"
1440 1440 msgid "SUN4V-8002-SP.severity"
1441 1441 msgstr "Major"
1442 1442 msgid "SUN4V-8002-SP.description"
1443 1443 msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n Refer to %s for more information."
1444 1444 msgid "SUN4V-8002-SP.response"
1445 1445 msgstr "No automated response.\n"
1446 1446 msgid "SUN4V-8002-SP.impact"
1447 1447 msgstr "This error does not affect system operation. The error which\ncould not be reported may have more serious impact which cannot be determined.\n"
1448 1448 msgid "SUN4V-8002-SP.action"
1449 1449 msgstr "Call your service provider to determine if your system requires a firmware\nupgrade. Please retain the error log file.\n"
1450 1450 #
1451 1451 # code: SUN4V-8002-T5
1452 1452 # keys: fault.cpu.generic-sparc.bootbus
1453 1453 #
1454 1454 msgid "SUN4V-8002-T5.type"
1455 1455 msgstr "Fault"
1456 1456 msgid "SUN4V-8002-T5.severity"
1457 1457 msgstr "Critical"
1458 1458 msgid "SUN4V-8002-T5.description"
1459 1459 msgstr "A system boot bus error has occurred.\n Refer to %s for more information."
1460 1460 msgid "SUN4V-8002-T5.response"
1461 1461 msgstr "No automated response.\n"
1462 1462 msgid "SUN4V-8002-T5.impact"
1463 1463 msgstr "The system's integrity is seriously compromised. Processor chip(s)\nmay be unavailable.\n"
1464 1464 msgid "SUN4V-8002-T5.action"
1465 1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 1466 #
1467 1467 # code: SUN4V-8002-US
1468 1468 # keys: fault.sp.failed
1469 1469 #
1470 1470 msgid "SUN4V-8002-US.type"
|
↓ open down ↓ |
811 lines elided |
↑ open up ↑ |
1471 1471 msgstr "Fault"
1472 1472 msgid "SUN4V-8002-US.severity"
1473 1473 msgstr "Critical"
1474 1474 msgid "SUN4V-8002-US.description"
1475 1475 msgstr "The Service Processor failed.\n Refer to %s for more information."
1476 1476 msgid "SUN4V-8002-US.response"
1477 1477 msgstr "No automated response.\n"
1478 1478 msgid "SUN4V-8002-US.impact"
1479 1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 1480 msgid "SUN4V-8002-US.action"
1481 -msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"
1481 +msgstr "Schedule a repair procedure for the Service Processor, or contact your illumos distribution team for support.\n"
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX