8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
    
      
        | Split | 
	Close | 
      
      | Expand all | 
      | Collapse all | 
    
    
          --- old/usr/src/cmd/fm/dicts/SUN4V.po
          +++ new/usr/src/cmd/fm/dicts/SUN4V.po
   1    1  #
   2    2  # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
   3    3  # Use is subject to license terms.
   4    4  #
   5    5  # CDDL HEADER START
   6    6  #
   7    7  # The contents of this file are subject to the terms of the
   8    8  # Common Development and Distribution License (the "License").
   9    9  # You may not use this file except in compliance with the License.
  10   10  #
  11   11  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12   12  # or http://www.opensolaris.org/os/licensing.
  13   13  # See the License for the specific language governing permissions
  14   14  # and limitations under the License.
  15   15  #
  16   16  # When distributing Covered Code, include this CDDL HEADER in each
  17   17  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18   18  # If applicable, add the following below this CDDL HEADER, with the
  19   19  # fields enclosed by brackets "[]" replaced with your own identifying
  20   20  # information: Portions Copyright [yyyy] [name of copyright owner]
  21   21  #
  22   22  # CDDL HEADER END
  23   23  #
  24   24  # DO NOT EDIT -- this file is generated by the Event Registry.
  25   25  #
  26   26  #
  27   27  # code: SUN4V-8000-1S
  28   28  # keys: fault.cpu.ultraSPARC-T1.ireg
  29   29  #
  30   30  msgid "SUN4V-8000-1S.type"
  31   31  msgstr "Fault"
  32   32  msgid "SUN4V-8000-1S.severity"
  33   33  msgstr "Minor"
  34   34  msgid "SUN4V-8000-1S.description"
  35   35  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  36   36  msgid "SUN4V-8000-1S.response"
  37   37  msgstr "The fault manager will attempt to remove the affected CPU from service."
  38   38  msgid "SUN4V-8000-1S.impact"
  39   39  msgstr "System performance may be affected."
  40   40  msgid "SUN4V-8000-1S.action"
  41   41  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  42   42  #
  43   43  # code: SUN4V-8000-2A
  44   44  # keys: fault.cpu.ultraSPARC-T1.freg
  45   45  #
  46   46  msgid "SUN4V-8000-2A.type"
  47   47  msgstr "Fault"
  48   48  msgid "SUN4V-8000-2A.severity"
  49   49  msgstr "Major"
  50   50  msgid "SUN4V-8000-2A.description"
  51   51  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  52   52  msgid "SUN4V-8000-2A.response"
  53   53  msgstr "None"
  54   54  msgid "SUN4V-8000-2A.impact"
  55   55  msgstr "System performance may be affected."
  56   56  msgid "SUN4V-8000-2A.action"
  57   57  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  58   58  #
  59   59  # code: SUN4V-8000-3P
  60   60  # keys: fault.cpu.ultraSPARC-T1.itlb
  61   61  #
  62   62  msgid "SUN4V-8000-3P.type"
  63   63  msgstr "Fault"
  64   64  msgid "SUN4V-8000-3P.severity"
  65   65  msgstr "Minor"
  66   66  msgid "SUN4V-8000-3P.description"
  67   67  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  68   68  msgid "SUN4V-8000-3P.response"
  69   69  msgstr "The fault manager will attempt to remove the affected CPU from service."
  70   70  msgid "SUN4V-8000-3P.impact"
  71   71  msgstr "System performance may be affected.\n"
  72   72  msgid "SUN4V-8000-3P.action"
  73   73  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  74   74  #
  75   75  # code: SUN4V-8000-4D
  76   76  # keys: fault.cpu.ultraSPARC-T1.dtlb
  77   77  #
  78   78  msgid "SUN4V-8000-4D.type"
  79   79  msgstr "Fault"
  80   80  msgid "SUN4V-8000-4D.severity"
  81   81  msgstr "Minor"
  82   82  msgid "SUN4V-8000-4D.description"
  83   83  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  84   84  msgid "SUN4V-8000-4D.response"
  85   85  msgstr "The fault manager will attempt to remove the affected CPU from service."
  86   86  msgid "SUN4V-8000-4D.impact"
  87   87  msgstr "System performance may be affected.\n"
  88   88  msgid "SUN4V-8000-4D.action"
  89   89  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  90   90  #
  91   91  # code: SUN4V-8000-5H
  92   92  # keys: fault.cpu.ultraSPARC-T1.icache
  93   93  #
  94   94  msgid "SUN4V-8000-5H.type"
  95   95  msgstr "Fault"
  96   96  msgid "SUN4V-8000-5H.severity"
  97   97  msgstr "Minor"
  98   98  msgid "SUN4V-8000-5H.description"
  99   99  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 100  100  msgid "SUN4V-8000-5H.response"
 101  101  msgstr "The fault manager will attempt to remove the affected CPU from service."
 102  102  msgid "SUN4V-8000-5H.impact"
 103  103  msgstr "System performance may be affected.\n"
 104  104  msgid "SUN4V-8000-5H.action"
 105  105  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 106  106  #
 107  107  # code: SUN4V-8000-63
 108  108  # keys: fault.cpu.ultraSPARC-T1.dcache
 109  109  #
 110  110  msgid "SUN4V-8000-63.type"
 111  111  msgstr "Fault"
 112  112  msgid "SUN4V-8000-63.severity"
 113  113  msgstr "Minor"
 114  114  msgid "SUN4V-8000-63.description"
 115  115  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 116  116  msgid "SUN4V-8000-63.response"
 117  117  msgstr "The fault manager will attempt to remove the affected CPU from service."
 118  118  msgid "SUN4V-8000-63.impact"
 119  119  msgstr "System performance may be affected.\n"
 120  120  msgid "SUN4V-8000-63.action"
 121  121  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 122  122  #
 123  123  # code: SUN4V-8000-7Y
 124  124  # keys: fault.cpu.ultraSPARC-T1.mau
 125  125  #
 126  126  msgid "SUN4V-8000-7Y.type"
 127  127  msgstr "Fault"
 128  128  msgid "SUN4V-8000-7Y.severity"
 129  129  msgstr "Major"
 130  130  msgid "SUN4V-8000-7Y.description"
 131  131  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 132  132  msgid "SUN4V-8000-7Y.response"
 133  133  msgstr "None"
 134  134  msgid "SUN4V-8000-7Y.impact"
 135  135  msgstr "System performance may be affected.\n"
 136  136  msgid "SUN4V-8000-7Y.action"
 137  137  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 138  138  #
 139  139  # code: SUN4V-8000-8Q
 140  140  # keys: fault.cpu.ultraSPARC-T1.l2cachedata
 141  141  #
 142  142  msgid "SUN4V-8000-8Q.type"
 143  143  msgstr "Fault"
 144  144  msgid "SUN4V-8000-8Q.severity"
 145  145  msgstr "Critical"
 146  146  msgid "SUN4V-8000-8Q.description"
 147  147  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 148  148  msgid "SUN4V-8000-8Q.response"
 149  149  msgstr "None"
 150  150  msgid "SUN4V-8000-8Q.impact"
 151  151  msgstr "System performance may be affected.\n"
 152  152  msgid "SUN4V-8000-8Q.action"
 153  153  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 154  154  #
 155  155  # code: SUN4V-8000-9C
 156  156  # keys: fault.cpu.ultraSPARC-T1.l2cachetag
 157  157  #
 158  158  msgid "SUN4V-8000-9C.type"
 159  159  msgstr "Fault"
 160  160  msgid "SUN4V-8000-9C.severity"
 161  161  msgstr "Critical"
 162  162  msgid "SUN4V-8000-9C.description"
 163  163  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 164  164  msgid "SUN4V-8000-9C.response"
 165  165  msgstr "None"
 166  166  msgid "SUN4V-8000-9C.impact"
 167  167  msgstr "System performance may be affected.\n"
 168  168  msgid "SUN4V-8000-9C.action"
 169  169  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 170  170  #
 171  171  # code: SUN4V-8000-AR
 172  172  # keys: fault.cpu.ultraSPARC-T1.l2cachectl
 173  173  #
 174  174  msgid "SUN4V-8000-AR.type"
 175  175  msgstr "Fault"
 176  176  msgid "SUN4V-8000-AR.severity"
 177  177  msgstr "Critical"
 178  178  msgid "SUN4V-8000-AR.description"
 179  179  msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 180  180  msgid "SUN4V-8000-AR.response"
 181  181  msgstr "None"
 182  182  msgid "SUN4V-8000-AR.impact"
 183  183  msgstr "System performance may be affected.\n"
 184  184  msgid "SUN4V-8000-AR.action"
 185  185  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 186  186  #
 187  187  # code: SUN4V-8000-C4
 188  188  # keys: fault.memory.page
 189  189  #
 190  190  msgid "SUN4V-8000-C4.type"
 191  191  msgstr "Fault"
 192  192  msgid "SUN4V-8000-C4.severity"
 193  193  msgstr "Minor"
 194  194  msgid "SUN4V-8000-C4.description"
 195  195  msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
 196  196  msgid "SUN4V-8000-C4.response"
 197  197  msgstr "An attempt will be made to remove this memory page from service."
 198  198  msgid "SUN4V-8000-C4.impact"
 199  199  msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
 200  200  msgid "SUN4V-8000-C4.action"
 201  201  msgstr "No repair action is recommended at this time."
 202  202  #
 203  203  # code: SUN4V-8000-DX
 204  204  # keys: fault.memory.dimm
 205  205  #
 206  206  msgid "SUN4V-8000-DX.type"
 207  207  msgstr "Fault"
 208  208  msgid "SUN4V-8000-DX.severity"
 209  209  msgstr "Major"
 210  210  msgid "SUN4V-8000-DX.description"
 211  211  msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
 212  212  msgid "SUN4V-8000-DX.response"
 213  213  msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
 214  214  msgid "SUN4V-8000-DX.impact"
 215  215  msgstr "Total system memory capacity has been reduced."
 216  216  msgid "SUN4V-8000-DX.action"
 217  217  msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
 218  218  #
 219  219  # code: SUN4V-8000-E2
 220  220  # keys: fault.memory.bank
 221  221  #
 222  222  msgid "SUN4V-8000-E2.type"
 223  223  msgstr "Fault"
 224  224  msgid "SUN4V-8000-E2.severity"
 225  225  msgstr "Critical"
 226  226  msgid "SUN4V-8000-E2.description"
 227  227  msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
 228  228  msgid "SUN4V-8000-E2.response"
 229  229  msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
 230  230  msgid "SUN4V-8000-E2.impact"
 231  231  msgstr "Total system memory capacity will be reduced as pages are retired."
 232  232  msgid "SUN4V-8000-E2.action"
 233  233  msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
 234  234  #
 235  235  # code: SUN4V-8000-FJ
 236  236  # keys: fault.memory.link-c
 237  237  #
 238  238  msgid "SUN4V-8000-FJ.type"
  
    | 
      ↓ open down ↓ | 
    238 lines elided | 
    
      ↑ open up ↑ | 
  
 239  239  msgstr "Fault"
 240  240  msgid "SUN4V-8000-FJ.severity"
 241  241  msgstr "Major"
 242  242  msgid "SUN4V-8000-FJ.description"
 243  243  msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 244  244  msgid "SUN4V-8000-FJ.response"
 245  245  msgstr "No automated response.\n"
 246  246  msgid "SUN4V-8000-FJ.impact"
 247  247  msgstr "System performance may be impacted.\n"
 248  248  msgid "SUN4V-8000-FJ.action"
 249      -msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
      249 +msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 250  250  #
 251  251  # code: SUN4V-8000-GE
 252  252  # keys: fault.cpu.ultraSPARC-T2.ireg
 253  253  #
 254  254  msgid "SUN4V-8000-GE.type"
 255  255  msgstr "Fault"
 256  256  msgid "SUN4V-8000-GE.severity"
 257  257  msgstr "Minor"
 258  258  msgid "SUN4V-8000-GE.description"
 259  259  msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 260  260  msgid "SUN4V-8000-GE.response"
 261  261  msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 262  262  msgid "SUN4V-8000-GE.impact"
 263  263  msgstr "System performance may be affected. \n"
 264  264  msgid "SUN4V-8000-GE.action"
 265  265  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 266  266  #
 267  267  # code: SUN4V-8000-HP
 268  268  # keys: fault.cpu.ultraSPARC-T2.freg
 269  269  #
 270  270  msgid "SUN4V-8000-HP.type"
 271  271  msgstr "Fault"
 272  272  msgid "SUN4V-8000-HP.severity"
 273  273  msgstr "Minor"
 274  274  msgid "SUN4V-8000-HP.description"
 275  275  msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 276  276  msgid "SUN4V-8000-HP.response"
 277  277  msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 278  278  msgid "SUN4V-8000-HP.impact"
 279  279  msgstr "System performance may be affected. \n"
 280  280  msgid "SUN4V-8000-HP.action"
 281  281  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 282  282  #
 283  283  # code: SUN4V-8000-JA
 284  284  # keys: fault.cpu.ultraSPARC-T2.misc_reg
 285  285  #
 286  286  msgid "SUN4V-8000-JA.type"
 287  287  msgstr "Fault"
 288  288  msgid "SUN4V-8000-JA.severity"
 289  289  msgstr "Minor"
 290  290  msgid "SUN4V-8000-JA.description"
 291  291  msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 292  292  msgid "SUN4V-8000-JA.response"
 293  293  msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 294  294  msgid "SUN4V-8000-JA.impact"
 295  295  msgstr "System performance may be affected. \n"
 296  296  msgid "SUN4V-8000-JA.action"
 297  297  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 298  298  #
 299  299  # code: SUN4V-8000-KS
 300  300  # keys: fault.cpu.ultraSPARC-T2.itlb
 301  301  #
 302  302  msgid "SUN4V-8000-KS.type"
 303  303  msgstr "Fault"
 304  304  msgid "SUN4V-8000-KS.severity"
 305  305  msgstr "Major"
 306  306  msgid "SUN4V-8000-KS.description"
 307  307  msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 308  308  msgid "SUN4V-8000-KS.response"
 309  309  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 310  310  msgid "SUN4V-8000-KS.impact"
 311  311  msgstr "System performance is likely to be affected. \n"
 312  312  msgid "SUN4V-8000-KS.action"
 313  313  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 314  314  #
 315  315  # code: SUN4V-8000-L5
 316  316  # keys: fault.cpu.ultraSPARC-T2.dtlb
 317  317  #
 318  318  msgid "SUN4V-8000-L5.type"
 319  319  msgstr "Fault"
 320  320  msgid "SUN4V-8000-L5.severity"
 321  321  msgstr "Major"
 322  322  msgid "SUN4V-8000-L5.description"
 323  323  msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 324  324  msgid "SUN4V-8000-L5.response"
 325  325  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 326  326  msgid "SUN4V-8000-L5.impact"
 327  327  msgstr "System performance is likely to be affected. \n"
 328  328  msgid "SUN4V-8000-L5.action"
 329  329  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 330  330  #
 331  331  # code: SUN4V-8000-MY
 332  332  # keys: fault.cpu.ultraSPARC-T2.icache
 333  333  #
 334  334  msgid "SUN4V-8000-MY.type"
 335  335  msgstr "Fault"
 336  336  msgid "SUN4V-8000-MY.severity"
 337  337  msgstr "Major"
 338  338  msgid "SUN4V-8000-MY.description"
 339  339  msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 340  340  msgid "SUN4V-8000-MY.response"
 341  341  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 342  342  msgid "SUN4V-8000-MY.impact"
 343  343  msgstr "System performance is likely to be affected. \n"
 344  344  msgid "SUN4V-8000-MY.action"
 345  345  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 346  346  #
 347  347  # code: SUN4V-8000-N3
 348  348  # keys: fault.cpu.ultraSPARC-T2.dcache
 349  349  #
 350  350  msgid "SUN4V-8000-N3.type"
 351  351  msgstr "Fault"
 352  352  msgid "SUN4V-8000-N3.severity"
 353  353  msgstr "Major"
 354  354  msgid "SUN4V-8000-N3.description"
 355  355  msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 356  356  msgid "SUN4V-8000-N3.response"
 357  357  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 358  358  msgid "SUN4V-8000-N3.impact"
 359  359  msgstr "System performance is likely to be affected. \n"
 360  360  msgid "SUN4V-8000-N3.action"
 361  361  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 362  362  #
 363  363  # code: SUN4V-8000-PH
 364  364  # keys: fault.cpu.ultraSPARC-T2.mau
 365  365  #
 366  366  msgid "SUN4V-8000-PH.type"
 367  367  msgstr "Fault"
 368  368  msgid "SUN4V-8000-PH.severity"
 369  369  msgstr "Major"
 370  370  msgid "SUN4V-8000-PH.description"
 371  371  msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n  Refer to %s for more information."
 372  372  msgid "SUN4V-8000-PH.response"
 373  373  msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
 374  374  msgid "SUN4V-8000-PH.impact"
 375  375  msgstr "System performance is likely to be affected. \n"
 376  376  msgid "SUN4V-8000-PH.action"
 377  377  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 378  378  #
 379  379  # code: SUN4V-8000-QD
 380  380  # keys: fault.cpu.ultraSPARC-T2.l2data-c
 381  381  #
 382  382  msgid "SUN4V-8000-QD.type"
 383  383  msgstr "Fault"
 384  384  msgid "SUN4V-8000-QD.severity"
 385  385  msgstr "Critical"
 386  386  msgid "SUN4V-8000-QD.description"
 387  387  msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 388  388  msgid "SUN4V-8000-QD.response"
 389  389  msgstr "No automated response.\n"
 390  390  msgid "SUN4V-8000-QD.impact"
 391  391  msgstr "System performance is likely to be affected. \n"
 392  392  msgid "SUN4V-8000-QD.action"
 393  393  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 394  394  #
 395  395  # code: SUN4V-8000-R4
 396  396  # keys: fault.cpu.ultraSPARC-T2.l2cachetag
 397  397  #
 398  398  msgid "SUN4V-8000-R4.type"
 399  399  msgstr "Fault"
 400  400  msgid "SUN4V-8000-R4.severity"
 401  401  msgstr "Critical"
 402  402  msgid "SUN4V-8000-R4.description"
 403  403  msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
 404  404  msgid "SUN4V-8000-R4.response"
 405  405  msgstr "No automated response.\n"
 406  406  msgid "SUN4V-8000-R4.impact"
 407  407  msgstr "System performance is likely to be affected. \n"
 408  408  msgid "SUN4V-8000-R4.action"
 409  409  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 410  410  #
 411  411  # code: SUN4V-8000-SR
 412  412  # keys: fault.cpu.ultraSPARC-T2.l2cachectl
 413  413  #
 414  414  msgid "SUN4V-8000-SR.type"
 415  415  msgstr "Fault"
 416  416  msgid "SUN4V-8000-SR.severity"
 417  417  msgstr "Critical"
 418  418  msgid "SUN4V-8000-SR.description"
 419  419  msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
 420  420  msgid "SUN4V-8000-SR.response"
 421  421  msgstr "No automated response.\n"
 422  422  msgid "SUN4V-8000-SR.impact"
 423  423  msgstr "System performance is likely to be affected. System may be unstable.\n"
 424  424  msgid "SUN4V-8000-SR.action"
 425  425  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 426  426  #
 427  427  # code: SUN4V-8000-TC
 428  428  # keys: fault.memory.link-u
 429  429  #
 430  430  msgid "SUN4V-8000-TC.type"
  
    | 
      ↓ open down ↓ | 
    171 lines elided | 
    
      ↑ open up ↑ | 
  
 431  431  msgstr "Fault"
 432  432  msgid "SUN4V-8000-TC.severity"
 433  433  msgstr "Critical"
 434  434  msgid "SUN4V-8000-TC.description"
 435  435  msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 436  436  msgid "SUN4V-8000-TC.response"
 437  437  msgstr "No automated response.\n"
 438  438  msgid "SUN4V-8000-TC.impact"
 439  439  msgstr "System performance may be impacted.\n"
 440  440  msgid "SUN4V-8000-TC.action"
 441      -msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
      441 +msgstr "At a convenient time, try reseating the memory module.  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 442  442  #
 443  443  # code: SUN4V-8000-UQ
 444  444  # keys: fault.cpu.ultraSPARC-T2.l2data-u
 445  445  #
 446  446  msgid "SUN4V-8000-UQ.type"
 447  447  msgstr "Fault"
 448  448  msgid "SUN4V-8000-UQ.severity"
 449  449  msgstr "Critical"
 450  450  msgid "SUN4V-8000-UQ.description"
 451  451  msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 452  452  msgid "SUN4V-8000-UQ.response"
 453  453  msgstr "No automated response.\n"
 454  454  msgid "SUN4V-8000-UQ.impact"
 455  455  msgstr "System performance is likely to be affected. \n"
 456  456  msgid "SUN4V-8000-UQ.action"
 457  457  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 458  458  #
 459  459  # code: SUN4V-8000-VE
 460  460  # keys: fault.cpu.ultraSPARC-T1.l2data-c
 461  461  #
 462  462  msgid "SUN4V-8000-VE.type"
 463  463  msgstr "Fault"
 464  464  msgid "SUN4V-8000-VE.severity"
 465  465  msgstr "Critical"
 466  466  msgid "SUN4V-8000-VE.description"
 467  467  msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 468  468  msgid "SUN4V-8000-VE.response"
 469  469  msgstr "No automated response.\n"
 470  470  msgid "SUN4V-8000-VE.impact"
 471  471  msgstr "System performance is likely to be affected. \n"
 472  472  msgid "SUN4V-8000-VE.action"
 473  473  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 474  474  #
 475  475  # code: SUN4V-8000-WJ
 476  476  # keys: fault.cpu.ultraSPARC-T1.l2data-u
 477  477  #
 478  478  msgid "SUN4V-8000-WJ.type"
 479  479  msgstr "Fault"
 480  480  msgid "SUN4V-8000-WJ.severity"
 481  481  msgstr "Critical"
 482  482  msgid "SUN4V-8000-WJ.description"
 483  483  msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 484  484  msgid "SUN4V-8000-WJ.response"
 485  485  msgstr "No automated response.\n"
 486  486  msgid "SUN4V-8000-WJ.impact"
 487  487  msgstr "System performance is likely to be affected. \n"
 488  488  msgid "SUN4V-8000-WJ.action"
 489  489  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 490  490  #
  
    | 
      ↓ open down ↓ | 
    39 lines elided | 
    
      ↑ open up ↑ | 
  
 491  491  # code: SUN4V-8000-X2
 492  492  # keys: fault.memory.datapath
 493  493  #
 494  494  msgid "SUN4V-8000-X2.type"
 495  495  msgstr "Fault"
 496  496  msgid "SUN4V-8000-X2.severity"
 497  497  msgstr "Major"
 498  498  msgid "SUN4V-8000-X2.description"
 499  499  msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
 500  500  msgid "SUN4V-8000-X2.response"
 501      -msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
      501 +msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n"
 502  502  msgid "SUN4V-8000-X2.impact"
 503  503  msgstr "System performance and stability may be affected. \n"
 504  504  msgid "SUN4V-8000-X2.action"
 505  505  msgstr "Contact your service provider for further diagnosis.\n"
 506  506  #
 507  507  # code: SUN4V-8000-YX
 508  508  # keys: fault.io.n2.ncu
 509  509  #
 510  510  msgid "SUN4V-8000-YX.type"
 511  511  msgstr "Fault"
 512  512  msgid "SUN4V-8000-YX.severity"
 513  513  msgstr "Critical"
 514  514  msgid "SUN4V-8000-YX.description"
 515  515  msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
 516  516  msgid "SUN4V-8000-YX.response"
 517  517  msgstr "One or more device instances may be disabled\n"
 518  518  msgid "SUN4V-8000-YX.impact"
 519  519  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 520  520  msgid "SUN4V-8000-YX.action"
 521      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      521 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n"
 522  522  #
 523  523  # code: SUN4V-8001-02
 524  524  # keys: fault.io.n2.dmu
 525  525  #
 526  526  msgid "SUN4V-8001-02.type"
 527  527  msgstr "Fault"
 528  528  msgid "SUN4V-8001-02.severity"
 529  529  msgstr "Critical"
 530  530  msgid "SUN4V-8001-02.description"
 531  531  msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
 532  532  msgid "SUN4V-8001-02.response"
 533  533  msgstr "One or more device instances may be disabled\n"
 534  534  msgid "SUN4V-8001-02.impact"
 535  535  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 536  536  msgid "SUN4V-8001-02.action"
 537      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      537 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 538  538  #
 539  539  # code: SUN4V-8001-1X
 540  540  # keys: fault.io.n2.niu
 541  541  #
 542  542  msgid "SUN4V-8001-1X.type"
 543  543  msgstr "Fault"
 544  544  msgid "SUN4V-8001-1X.severity"
 545  545  msgstr "Critical"
 546  546  msgid "SUN4V-8001-1X.description"
 547  547  msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
 548  548  msgid "SUN4V-8001-1X.response"
 549  549  msgstr "One or more device instances may be disabled\n"
 550  550  msgid "SUN4V-8001-1X.impact"
 551  551  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 552  552  msgid "SUN4V-8001-1X.action"
 553      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      553 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 554  554  #
 555  555  # code: SUN4V-8001-2E
 556  556  # keys: fault.io.n2.siu
 557  557  #
 558  558  msgid "SUN4V-8001-2E.type"
 559  559  msgstr "Fault"
 560  560  msgid "SUN4V-8001-2E.severity"
 561  561  msgstr "Critical"
 562  562  msgid "SUN4V-8001-2E.description"
 563  563  msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
 564  564  msgid "SUN4V-8001-2E.response"
 565  565  msgstr "One or more device instances may be disabled\n"
 566  566  msgid "SUN4V-8001-2E.impact"
 567  567  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 568  568  msgid "SUN4V-8001-2E.action"
 569      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      569 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 570  570  #
 571  571  # code: SUN4V-8001-3J
 572  572  # keys: fault.io.n2.soc
 573  573  #
 574  574  msgid "SUN4V-8001-3J.type"
 575  575  msgstr "Fault"
 576  576  msgid "SUN4V-8001-3J.severity"
 577  577  msgstr "Critical"
 578  578  msgid "SUN4V-8001-3J.description"
 579  579  msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
 580  580  msgid "SUN4V-8001-3J.response"
 581  581  msgstr "One or more device instances may be disabled\n"
 582  582  msgid "SUN4V-8001-3J.impact"
 583  583  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 584  584  msgid "SUN4V-8001-3J.action"
 585      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      585 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 586  586  #
 587  587  # code: SUN4V-8001-4C
 588  588  # keys: fault.io.n2.crossbar
 589  589  #
 590  590  msgid "SUN4V-8001-4C.type"
 591  591  msgstr "Fault"
 592  592  msgid "SUN4V-8001-4C.severity"
 593  593  msgstr "Critical"
 594  594  msgid "SUN4V-8001-4C.description"
 595  595  msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
 596  596  msgid "SUN4V-8001-4C.response"
 597  597  msgstr "One or more device instances may be disabled\n"
 598  598  msgid "SUN4V-8001-4C.impact"
 599  599  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 600  600  msgid "SUN4V-8001-4C.action"
 601      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      601 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 602  602  #
 603  603  # code: SUN4V-8001-5Q
 604  604  # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
 605  605  #
 606  606  msgid "SUN4V-8001-5Q.type"
 607  607  msgstr "Fault"
 608  608  msgid "SUN4V-8001-5Q.severity"
 609  609  msgstr "Critical"
 610  610  msgid "SUN4V-8001-5Q.description"
 611  611  msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
 612  612  msgid "SUN4V-8001-5Q.response"
 613  613  msgstr "One or more device instances may be disabled\n"
 614  614  msgid "SUN4V-8001-5Q.impact"
 615  615  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 616  616  msgid "SUN4V-8001-5Q.action"
 617      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      617 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 618  618  #
 619  619  # code: SUN4V-8001-64
 620  620  # keys: fault.io.vf.ncx
 621  621  #
 622  622  msgid "SUN4V-8001-64.type"
 623  623  msgstr "Fault"
 624  624  msgid "SUN4V-8001-64.severity"
 625  625  msgstr "Critical"
 626  626  msgid "SUN4V-8001-64.description"
 627  627  msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
 628  628  msgid "SUN4V-8001-64.response"
 629  629  msgstr "One or more device instances may be disabled\n"
 630  630  msgid "SUN4V-8001-64.impact"
 631  631  msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 632  632  msgid "SUN4V-8001-64.action"
 633      -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
      633 +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 634  634  #
 635  635  # code: SUN4V-8001-7R
 636  636  # keys: fault.memory.link-f
 637  637  #
 638  638  msgid "SUN4V-8001-7R.type"
 639  639  msgstr "Fault"
 640  640  msgid "SUN4V-8001-7R.severity"
 641  641  msgstr "Major"
 642  642  msgid "SUN4V-8001-7R.description"
 643  643  msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
 644  644  msgid "SUN4V-8001-7R.response"
 645  645  msgstr "No automated response.\n"
 646  646  msgid "SUN4V-8001-7R.impact"
 647  647  msgstr "System performance may be impacted.\n"
 648  648  msgid "SUN4V-8001-7R.action"
 649      -msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
      649 +msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 650  650  #
 651  651  # code: SUN4V-8001-8H
 652  652  # keys: fault.cpu.ultraSPARC-T2plus.ireg
 653  653  #
 654  654  msgid "SUN4V-8001-8H.type"
 655  655  msgstr "Fault"
 656  656  msgid "SUN4V-8001-8H.severity"
 657  657  msgstr "Minor"
 658  658  msgid "SUN4V-8001-8H.description"
 659  659  msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 660  660  msgid "SUN4V-8001-8H.response"
 661  661  msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 662  662  msgid "SUN4V-8001-8H.impact"
 663  663  msgstr "System performance may be affected. \n"
 664  664  msgid "SUN4V-8001-8H.action"
 665  665  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 666  666  #
 667  667  # code: SUN4V-8001-9D
 668  668  # keys: fault.cpu.ultraSPARC-T2plus.freg
 669  669  #
 670  670  msgid "SUN4V-8001-9D.type"
 671  671  msgstr "Fault"
 672  672  msgid "SUN4V-8001-9D.severity"
 673  673  msgstr "Minor"
 674  674  msgid "SUN4V-8001-9D.description"
 675  675  msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 676  676  msgid "SUN4V-8001-9D.response"
 677  677  msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 678  678  msgid "SUN4V-8001-9D.impact"
 679  679  msgstr "System performance may be affected. \n"
 680  680  msgid "SUN4V-8001-9D.action"
 681  681  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 682  682  #
 683  683  # code: SUN4V-8001-AY
 684  684  # keys: fault.cpu.ultraSPARC-T2plus.misc_reg
 685  685  #
 686  686  msgid "SUN4V-8001-AY.type"
 687  687  msgstr "Fault"
 688  688  msgid "SUN4V-8001-AY.severity"
 689  689  msgstr "Minor"
 690  690  msgid "SUN4V-8001-AY.description"
 691  691  msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 692  692  msgid "SUN4V-8001-AY.response"
 693  693  msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 694  694  msgid "SUN4V-8001-AY.impact"
 695  695  msgstr "System performance may be affected. \n"
 696  696  msgid "SUN4V-8001-AY.action"
 697  697  msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 698  698  #
 699  699  # code: SUN4V-8001-C3
 700  700  # keys: fault.cpu.ultraSPARC-T2plus.itlb
 701  701  #
 702  702  msgid "SUN4V-8001-C3.type"
 703  703  msgstr "Fault"
 704  704  msgid "SUN4V-8001-C3.severity"
 705  705  msgstr "Major"
 706  706  msgid "SUN4V-8001-C3.description"
 707  707  msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 708  708  msgid "SUN4V-8001-C3.response"
 709  709  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 710  710  msgid "SUN4V-8001-C3.impact"
 711  711  msgstr "System performance is likely to be affected. \n"
 712  712  msgid "SUN4V-8001-C3.action"
 713  713  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 714  714  #
 715  715  # code: SUN4V-8001-DS
 716  716  # keys: fault.cpu.ultraSPARC-T2plus.dtlb
 717  717  #
 718  718  msgid "SUN4V-8001-DS.type"
 719  719  msgstr "Fault"
 720  720  msgid "SUN4V-8001-DS.severity"
 721  721  msgstr "Major"
 722  722  msgid "SUN4V-8001-DS.description"
 723  723  msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 724  724  msgid "SUN4V-8001-DS.response"
 725  725  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 726  726  msgid "SUN4V-8001-DS.impact"
 727  727  msgstr "System performance is likely to be affected. \n"
 728  728  msgid "SUN4V-8001-DS.action"
 729  729  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 730  730  #
 731  731  # code: SUN4V-8001-E5
 732  732  # keys: fault.cpu.ultraSPARC-T2plus.icache
 733  733  #
 734  734  msgid "SUN4V-8001-E5.type"
 735  735  msgstr "Fault"
 736  736  msgid "SUN4V-8001-E5.severity"
 737  737  msgstr "Major"
 738  738  msgid "SUN4V-8001-E5.description"
 739  739  msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 740  740  msgid "SUN4V-8001-E5.response"
 741  741  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 742  742  msgid "SUN4V-8001-E5.impact"
 743  743  msgstr "System performance is likely to be affected. \n"
 744  744  msgid "SUN4V-8001-E5.action"
 745  745  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 746  746  #
 747  747  # code: SUN4V-8001-FP
 748  748  # keys: fault.cpu.ultraSPARC-T2plus.dcache
 749  749  #
 750  750  msgid "SUN4V-8001-FP.type"
 751  751  msgstr "Fault"
 752  752  msgid "SUN4V-8001-FP.severity"
 753  753  msgstr "Major"
 754  754  msgid "SUN4V-8001-FP.description"
 755  755  msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 756  756  msgid "SUN4V-8001-FP.response"
 757  757  msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 758  758  msgid "SUN4V-8001-FP.impact"
 759  759  msgstr "System performance is likely to be affected. \n"
 760  760  msgid "SUN4V-8001-FP.action"
 761  761  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 762  762  #
 763  763  # code: SUN4V-8001-GA
 764  764  # keys: fault.cpu.ultraSPARC-T2plus.mau
 765  765  #
 766  766  msgid "SUN4V-8001-GA.type"
 767  767  msgstr "Fault"
 768  768  msgid "SUN4V-8001-GA.severity"
 769  769  msgstr "Major"
 770  770  msgid "SUN4V-8001-GA.description"
 771  771  msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 772  772  msgid "SUN4V-8001-GA.response"
 773  773  msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
 774  774  msgid "SUN4V-8001-GA.impact"
 775  775  msgstr "System performance is likely to be affected. \n"
 776  776  msgid "SUN4V-8001-GA.action"
 777  777  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 778  778  #
 779  779  # code: SUN4V-8001-HJ
 780  780  # keys: fault.cpu.ultraSPARC-T2plus.l2data-c
 781  781  #
 782  782  msgid "SUN4V-8001-HJ.type"
 783  783  msgstr "Fault"
 784  784  msgid "SUN4V-8001-HJ.severity"
 785  785  msgstr "Critical"
 786  786  msgid "SUN4V-8001-HJ.description"
 787  787  msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 788  788  msgid "SUN4V-8001-HJ.response"
 789  789  msgstr "No automated response.\n"
 790  790  msgid "SUN4V-8001-HJ.impact"
 791  791  msgstr "System performance is likely to be affected. \n"
 792  792  msgid "SUN4V-8001-HJ.action"
 793  793  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 794  794  #
 795  795  # code: SUN4V-8001-JE
 796  796  # keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
 797  797  #
 798  798  msgid "SUN4V-8001-JE.type"
 799  799  msgstr "Fault"
 800  800  msgid "SUN4V-8001-JE.severity"
 801  801  msgstr "Critical"
 802  802  msgid "SUN4V-8001-JE.description"
 803  803  msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
 804  804  msgid "SUN4V-8001-JE.response"
 805  805  msgstr "No automated response.\n"
 806  806  msgid "SUN4V-8001-JE.impact"
 807  807  msgstr "System performance is likely to be affected. \n"
 808  808  msgid "SUN4V-8001-JE.action"
 809  809  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 810  810  #
 811  811  # code: SUN4V-8001-KX
 812  812  # keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
 813  813  #
 814  814  msgid "SUN4V-8001-KX.type"
 815  815  msgstr "Fault"
 816  816  msgid "SUN4V-8001-KX.severity"
 817  817  msgstr "Critical"
 818  818  msgid "SUN4V-8001-KX.description"
 819  819  msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
 820  820  msgid "SUN4V-8001-KX.response"
 821  821  msgstr "No automated response.\n"
 822  822  msgid "SUN4V-8001-KX.impact"
 823  823  msgstr "System performance is likely to be affected. System may be unstable.\n"
 824  824  msgid "SUN4V-8001-KX.action"
 825  825  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 826  826  #
 827  827  # code: SUN4V-8001-L2
 828  828  # keys: fault.cpu.ultraSPARC-T2plus.l2data-u
 829  829  #
 830  830  msgid "SUN4V-8001-L2.type"
 831  831  msgstr "Fault"
 832  832  msgid "SUN4V-8001-L2.severity"
 833  833  msgstr "Critical"
 834  834  msgid "SUN4V-8001-L2.description"
 835  835  msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 836  836  msgid "SUN4V-8001-L2.response"
 837  837  msgstr "No automated response.\n"
 838  838  msgid "SUN4V-8001-L2.impact"
 839  839  msgstr "System performance is likely to be affected. \n"
 840  840  msgid "SUN4V-8001-L2.action"
 841  841  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 842  842  #
 843  843  # code: SUN4V-8001-MR
 844  844  # keys: fault.cpu.ultraSPARC-T2plus.lfu-f
 845  845  #
 846  846  msgid "SUN4V-8001-MR.type"
 847  847  msgstr "Fault"
 848  848  msgid "SUN4V-8001-MR.severity"
 849  849  msgstr "Major"
 850  850  msgid "SUN4V-8001-MR.description"
 851  851  msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n  Refer to %s for more information."
 852  852  msgid "SUN4V-8001-MR.response"
 853  853  msgstr "No other automated response.\n"
 854  854  msgid "SUN4V-8001-MR.impact"
 855  855  msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
 856  856  msgid "SUN4V-8001-MR.action"
 857  857  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 858  858  #
 859  859  # code: SUN4V-8001-N4
 860  860  # keys: fault.cpu.ultraSPARC-T2plus.lfu-p
 861  861  #
 862  862  msgid "SUN4V-8001-N4.type"
 863  863  msgstr "Fault"
 864  864  msgid "SUN4V-8001-N4.severity"
 865  865  msgstr "Major"
 866  866  msgid "SUN4V-8001-N4.description"
 867  867  msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n  Refer to %s for more information."
 868  868  msgid "SUN4V-8001-N4.response"
 869  869  msgstr "No automated response.\n"
 870  870  msgid "SUN4V-8001-N4.impact"
 871  871  msgstr "The system has most likely taken a fatal reset.\n"
 872  872  msgid "SUN4V-8001-N4.action"
 873  873  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 874  874  #
 875  875  # code: SUN4V-8001-PQ
 876  876  # keys: fault.cpu.ultraSPARC-T2plus.lfu-u
 877  877  #
 878  878  msgid "SUN4V-8001-PQ.type"
 879  879  msgstr "Fault"
 880  880  msgid "SUN4V-8001-PQ.severity"
 881  881  msgstr "Major"
 882  882  msgid "SUN4V-8001-PQ.description"
 883  883  msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n  Refer to %s for more information."
 884  884  msgid "SUN4V-8001-PQ.response"
 885  885  msgstr "No automated response.\n"
 886  886  msgid "SUN4V-8001-PQ.impact"
 887  887  msgstr "The system's integrity is seriously compromised.\n"
 888  888  msgid "SUN4V-8001-PQ.action"
 889  889  msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 890  890  #
 891  891  # code: SUN4V-8001-QC
 892  892  # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
 893  893  #
 894  894  msgid "SUN4V-8001-QC.type"
 895  895  msgstr "Fault"
 896  896  msgid "SUN4V-8001-QC.severity"
 897  897  msgstr "Critical"
 898  898  msgid "SUN4V-8001-QC.description"
 899  899  msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n  Refer to %s for more information."
 900  900  msgid "SUN4V-8001-QC.response"
 901  901  msgstr "No automated reponse.\n"
 902  902  msgid "SUN4V-8001-QC.impact"
 903  903  msgstr "The system's integrity is compromised.\n"
 904  904  msgid "SUN4V-8001-QC.action"
 905  905  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 906  906  #
 907  907  # code: SUN4V-8001-R3
 908  908  # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
 909  909  #
 910  910  msgid "SUN4V-8001-R3.type"
 911  911  msgstr "Fault"
 912  912  msgid "SUN4V-8001-R3.severity"
 913  913  msgstr "Major"
 914  914  msgid "SUN4V-8001-R3.description"
 915  915  msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n  Refer to %s for more information."
 916  916  msgid "SUN4V-8001-R3.response"
 917  917  msgstr "No automated reponse.\n"
 918  918  msgid "SUN4V-8001-R3.impact"
 919  919  msgstr "The system's integrity is compromised.\n"
 920  920  msgid "SUN4V-8001-R3.action"
 921  921  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 922  922  #
 923  923  # code: SUN4V-8001-SY
 924  924  # keys: fault.cpu.ultraSPARC-T2plus.chip
 925  925  #
 926  926  msgid "SUN4V-8001-SY.type"
 927  927  msgstr "Fault"
 928  928  msgid "SUN4V-8001-SY.severity"
 929  929  msgstr "Critical"
 930  930  msgid "SUN4V-8001-SY.description"
 931  931  msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n  Refer to %s for more information."
 932  932  msgid "SUN4V-8001-SY.response"
 933  933  msgstr "No automated reponse.\n"
 934  934  msgid "SUN4V-8001-SY.impact"
 935  935  msgstr "The system's integrity is seriously compromised.\n"
 936  936  msgid "SUN4V-8001-SY.action"
 937  937  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 938  938  #
 939  939  # code: SUN4V-8001-TD
 940  940  # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
 941  941  #
 942  942  msgid "SUN4V-8001-TD.type"
 943  943  msgstr "Fault"
 944  944  msgid "SUN4V-8001-TD.severity"
 945  945  msgstr "Minor"
 946  946  msgid "SUN4V-8001-TD.description"
 947  947  msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n  Refer to %s for more information."
 948  948  msgid "SUN4V-8001-TD.response"
 949  949  msgstr "No automated reponse.\n"
 950  950  msgid "SUN4V-8001-TD.impact"
 951  951  msgstr "The system's integrity is seriously compromised.\n"
 952  952  msgid "SUN4V-8001-TD.action"
 953  953  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 954  954  #
 955  955  # code: SUN4V-8001-UH
 956  956  # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
 957  957  #
 958  958  msgid "SUN4V-8001-UH.type"
 959  959  msgstr "Fault"
 960  960  msgid "SUN4V-8001-UH.severity"
 961  961  msgstr "Major"
 962  962  msgid "SUN4V-8001-UH.description"
 963  963  msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n  Refer to %s for more information."
 964  964  msgid "SUN4V-8001-UH.response"
 965  965  msgstr "No automated reponse.\n"
 966  966  msgid "SUN4V-8001-UH.impact"
 967  967  msgstr "The system's performance may be impacted.\n"
 968  968  msgid "SUN4V-8001-UH.action"
 969  969  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 970  970  #
 971  971  # code: SUN4V-8001-VA
 972  972  # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
 973  973  #
 974  974  msgid "SUN4V-8001-VA.type"
 975  975  msgstr "Fault"
 976  976  msgid "SUN4V-8001-VA.severity"
 977  977  msgstr "Critical"
 978  978  msgid "SUN4V-8001-VA.description"
 979  979  msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n  Refer to %s for more information."
 980  980  msgid "SUN4V-8001-VA.response"
 981  981  msgstr "No automated reponse.\n"
 982  982  msgid "SUN4V-8001-VA.impact"
 983  983  msgstr "The system's integrity is seriously compromised.\n"
 984  984  msgid "SUN4V-8001-VA.action"
 985  985  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 986  986  #
 987  987  # code: SUN4V-8001-WP
 988  988  # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
 989  989  #
 990  990  msgid "SUN4V-8001-WP.type"
 991  991  msgstr "Fault"
 992  992  msgid "SUN4V-8001-WP.severity"
 993  993  msgstr "Critical"
 994  994  msgid "SUN4V-8001-WP.description"
 995  995  msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n  Refer to %s for more information."
 996  996  msgid "SUN4V-8001-WP.response"
 997  997  msgstr "No automated reponse.\n"
 998  998  msgid "SUN4V-8001-WP.impact"
 999  999  msgstr "The system's integrity is seriously compromised.\n"
1000 1000  msgid "SUN4V-8001-WP.action"
1001 1001  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1002 1002  #
1003 1003  # code: SUN4V-8001-X5
1004 1004  # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
1005 1005  #
1006 1006  msgid "SUN4V-8001-X5.type"
1007 1007  msgstr "Fault"
1008 1008  msgid "SUN4V-8001-X5.severity"
1009 1009  msgstr "Critical"
1010 1010  msgid "SUN4V-8001-X5.description"
1011 1011  msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n  Refer to %s for more information."
1012 1012  msgid "SUN4V-8001-X5.response"
1013 1013  msgstr "No automated reponse.\n"
1014 1014  msgid "SUN4V-8001-X5.impact"
1015 1015  msgstr "The system's performance may be compromised.\n"
1016 1016  msgid "SUN4V-8001-X5.action"
1017 1017  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1018 1018  #
1019 1019  # code: SUN4V-8001-YS
1020 1020  # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
1021 1021  #
1022 1022  msgid "SUN4V-8001-YS.type"
1023 1023  msgstr "Fault"
1024 1024  msgid "SUN4V-8001-YS.severity"
1025 1025  msgstr "Major"
1026 1026  msgid "SUN4V-8001-YS.description"
1027 1027  msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n  Refer to %s for more information."
1028 1028  msgid "SUN4V-8001-YS.response"
1029 1029  msgstr "No automated reponse.\n"
1030 1030  msgid "SUN4V-8001-YS.impact"
1031 1031  msgstr "The system's integrity may be seriously compromised.\n"
1032 1032  msgid "SUN4V-8001-YS.action"
1033 1033  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1034 1034  #
1035 1035  # code: SUN4V-8002-0C
1036 1036  # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1037 1037  #
1038 1038  msgid "SUN4V-8002-0C.type"
1039 1039  msgstr "Fault"
1040 1040  msgid "SUN4V-8002-0C.severity"
1041 1041  msgstr "Major"
1042 1042  msgid "SUN4V-8002-0C.description"
1043 1043  msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n  Refer to %s for more information."
1044 1044  msgid "SUN4V-8002-0C.response"
1045 1045  msgstr "No automated reponse.\n"
1046 1046  msgid "SUN4V-8002-0C.impact"
1047 1047  msgstr "The system's performance may be impacted.\n"
1048 1048  msgid "SUN4V-8002-0C.action"
1049 1049  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1050 1050  #
1051 1051  # code: SUN4V-8002-1Q
1052 1052  # keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1053 1053  #
1054 1054  msgid "SUN4V-8002-1Q.type"
1055 1055  msgstr "Fault"
1056 1056  msgid "SUN4V-8002-1Q.severity"
1057 1057  msgstr "Major"
1058 1058  msgid "SUN4V-8002-1Q.description"
1059 1059  msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n  Refer to %s for more information."
1060 1060  msgid "SUN4V-8002-1Q.response"
1061 1061  msgstr "No automated reponse.\n"
1062 1062  msgid "SUN4V-8002-1Q.impact"
1063 1063  msgstr "The system's performance may be impacted.\n"
1064 1064  msgid "SUN4V-8002-1Q.action"
1065 1065  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1066 1066  #
1067 1067  # code: SUN4V-8002-24
1068 1068  # keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
1069 1069  #
1070 1070  msgid "SUN4V-8002-24.type"
1071 1071  msgstr "Fault"
1072 1072  msgid "SUN4V-8002-24.severity"
1073 1073  msgstr "Critical"
1074 1074  msgid "SUN4V-8002-24.description"
1075 1075  msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n  Refer to %s for more information."
1076 1076  msgid "SUN4V-8002-24.response"
1077 1077  msgstr "No automated reponse.\n"
1078 1078  msgid "SUN4V-8002-24.impact"
1079 1079  msgstr "The system's integrity is seriously compromised.\n"
1080 1080  msgid "SUN4V-8002-24.action"
1081 1081  msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1082 1082  #
1083 1083  # code: SUN4V-8002-3R
1084 1084  # keys: fault.memory.dimm-page-retires-excessive
1085 1085  #
1086 1086  msgid "SUN4V-8002-3R.type"
1087 1087  msgstr "Fault"
1088 1088  msgid "SUN4V-8002-3R.severity"
1089 1089  msgstr "Major"
1090 1090  msgid "SUN4V-8002-3R.description"
1091 1091  msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n  Refer to %s for more information."
1092 1092  msgid "SUN4V-8002-3R.response"
1093 1093  msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
1094 1094  msgid "SUN4V-8002-3R.impact"
1095 1095  msgstr "Total system memory capacity has been reduced.\n"
1096 1096  msgid "SUN4V-8002-3R.action"
1097 1097  msgstr "Schedule a repair procedure to replace the DIMM.  Use fmadm faulty to identify the DIMM to replace.\n"
1098 1098  #
1099 1099  # code: SUN4V-8002-42
1100 1100  # keys: fault.memory.dimm-ue-imminent
1101 1101  #
1102 1102  msgid "SUN4V-8002-42.type"
1103 1103  msgstr "Fault"
1104 1104  msgid "SUN4V-8002-42.severity"
1105 1105  msgstr "Critical"
1106 1106  msgid "SUN4V-8002-42.description"
1107 1107  msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1108 1108  msgid "SUN4V-8002-42.response"
1109 1109  msgstr "None at this time.\n"
1110 1110  msgid "SUN4V-8002-42.impact"
1111 1111  msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1112 1112  msgid "SUN4V-8002-42.action"
1113 1113  msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1114 1114  #
1115 1115  # code: SUN4V-8002-5X
1116 1116  # keys: fault.memory.dram-ue-imminent
1117 1117  #
1118 1118  msgid "SUN4V-8002-5X.type"
1119 1119  msgstr "Fault"
1120 1120  msgid "SUN4V-8002-5X.severity"
1121 1121  msgstr "Critical"
1122 1122  msgid "SUN4V-8002-5X.description"
1123 1123  msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1124 1124  msgid "SUN4V-8002-5X.response"
1125 1125  msgstr "None at this time.\n"
1126 1126  msgid "SUN4V-8002-5X.impact"
1127 1127  msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1128 1128  msgid "SUN4V-8002-5X.action"
1129 1129  msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1130 1130  #
1131 1131  # code: SUN4V-8002-6E
1132 1132  # keys: fault.cpu.generic-sparc.strand
1133 1133  #
1134 1134  msgid "SUN4V-8002-6E.type"
1135 1135  msgstr "Fault"
1136 1136  msgid "SUN4V-8002-6E.severity"
1137 1137  msgstr "Major"
1138 1138  msgid "SUN4V-8002-6E.description"
1139 1139  msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n  Refer to %s for more information."
1140 1140  msgid "SUN4V-8002-6E.response"
1141 1141  msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1142 1142  msgid "SUN4V-8002-6E.impact"
1143 1143  msgstr "System performance may be affected. \n"
1144 1144  msgid "SUN4V-8002-6E.action"
1145 1145  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1146 1146  #
1147 1147  # code: SUN4V-8002-7J
1148 1148  # keys: fault.cpu.generic-sparc.strand-nr
1149 1149  #
1150 1150  msgid "SUN4V-8002-7J.type"
1151 1151  msgstr "Fault"
1152 1152  msgid "SUN4V-8002-7J.severity"
1153 1153  msgstr "Major"
1154 1154  msgid "SUN4V-8002-7J.description"
1155 1155  msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n  Refer to %s for more information."
1156 1156  msgid "SUN4V-8002-7J.response"
1157 1157  msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n"
1158 1158  msgid "SUN4V-8002-7J.impact"
1159 1159  msgstr "System performance may be affected. \n"
1160 1160  msgid "SUN4V-8002-7J.action"
1161 1161  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1162 1162  #
1163 1163  # code: SUN4V-8002-8S
1164 1164  # keys: fault.cpu.generic-sparc.strand-uc
1165 1165  #
1166 1166  msgid "SUN4V-8002-8S.type"
1167 1167  msgstr "Fault"
1168 1168  msgid "SUN4V-8002-8S.severity"
1169 1169  msgstr "Critical"
1170 1170  msgid "SUN4V-8002-8S.description"
1171 1171  msgstr "This strand has encountered an uncorrectable error.\n  Refer to %s for more information."
1172 1172  msgid "SUN4V-8002-8S.response"
1173 1173  msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1174 1174  msgid "SUN4V-8002-8S.impact"
1175 1175  msgstr "System performance may be affected. \n"
1176 1176  msgid "SUN4V-8002-8S.action"
1177 1177  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1178 1178  #
1179 1179  # code: SUN4V-8002-95
1180 1180  # keys: fault.cpu.generic-sparc.strand-uc-nr
1181 1181  #
1182 1182  msgid "SUN4V-8002-95.type"
1183 1183  msgstr "Fault"
1184 1184  msgid "SUN4V-8002-95.severity"
1185 1185  msgstr "Critical"
1186 1186  msgid "SUN4V-8002-95.description"
1187 1187  msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n  Refer to %s for more information."
1188 1188  msgid "SUN4V-8002-95.response"
1189 1189  msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n"
1190 1190  msgid "SUN4V-8002-95.impact"
1191 1191  msgstr "System performance may be affected. \n"
1192 1192  msgid "SUN4V-8002-95.action"
1193 1193  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1194 1194  #
1195 1195  # code: SUN4V-8002-AP
1196 1196  # keys: fault.cpu.generic-sparc.core
1197 1197  #
1198 1198  msgid "SUN4V-8002-AP.type"
1199 1199  msgstr "Fault"
1200 1200  msgid "SUN4V-8002-AP.severity"
1201 1201  msgstr "Major"
1202 1202  msgid "SUN4V-8002-AP.description"
1203 1203  msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n  Refer to %s for more information."
1204 1204  msgid "SUN4V-8002-AP.response"
1205 1205  msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1206 1206  msgid "SUN4V-8002-AP.impact"
1207 1207  msgstr "System performance may be affected. \n"
1208 1208  msgid "SUN4V-8002-AP.action"
1209 1209  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1210 1210  #
1211 1211  # code: SUN4V-8002-CA
1212 1212  # keys: fault.cpu.generic-sparc.core-nr
1213 1213  #
1214 1214  msgid "SUN4V-8002-CA.type"
1215 1215  msgstr "Fault"
1216 1216  msgid "SUN4V-8002-CA.severity"
1217 1217  msgstr "Major"
1218 1218  msgid "SUN4V-8002-CA.description"
1219 1219  msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n  Refer to %s for more information."
1220 1220  msgid "SUN4V-8002-CA.response"
1221 1221  msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1222 1222  msgid "SUN4V-8002-CA.impact"
1223 1223  msgstr "System performance may be affected. \n"
1224 1224  msgid "SUN4V-8002-CA.action"
1225 1225  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1226 1226  #
1227 1227  # code: SUN4V-8002-DH
1228 1228  # keys: fault.cpu.generic-sparc.core-uc
1229 1229  #
1230 1230  msgid "SUN4V-8002-DH.type"
1231 1231  msgstr "Fault"
1232 1232  msgid "SUN4V-8002-DH.severity"
1233 1233  msgstr "Critical"
1234 1234  msgid "SUN4V-8002-DH.description"
1235 1235  msgstr "This core has encountered an uncorrectable error.\n  Refer to %s for more information."
1236 1236  msgid "SUN4V-8002-DH.response"
1237 1237  msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1238 1238  msgid "SUN4V-8002-DH.impact"
1239 1239  msgstr "System performance may be affected. \n"
1240 1240  msgid "SUN4V-8002-DH.action"
1241 1241  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1242 1242  #
1243 1243  # code: SUN4V-8002-ED
1244 1244  # keys: fault.cpu.generic-sparc.core-uc-nr
1245 1245  #
1246 1246  msgid "SUN4V-8002-ED.type"
1247 1247  msgstr "Fault"
1248 1248  msgid "SUN4V-8002-ED.severity"
1249 1249  msgstr "Critical"
1250 1250  msgid "SUN4V-8002-ED.description"
1251 1251  msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n  Refer to %s for more information."
1252 1252  msgid "SUN4V-8002-ED.response"
1253 1253  msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1254 1254  msgid "SUN4V-8002-ED.impact"
1255 1255  msgstr "System performance may be affected. \n"
1256 1256  msgid "SUN4V-8002-ED.action"
1257 1257  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1258 1258  #
1259 1259  # code: SUN4V-8002-FY
1260 1260  # keys: fault.cpu.generic-sparc.chip
1261 1261  #
1262 1262  msgid "SUN4V-8002-FY.type"
1263 1263  msgstr "Fault"
1264 1264  msgid "SUN4V-8002-FY.severity"
1265 1265  msgstr "Critical"
1266 1266  msgid "SUN4V-8002-FY.description"
1267 1267  msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n  Refer to %s for more information."
1268 1268  msgid "SUN4V-8002-FY.response"
1269 1269  msgstr "No automated response.\n"
1270 1270  msgid "SUN4V-8002-FY.impact"
1271 1271  msgstr "System performance may be affected. \n"
1272 1272  msgid "SUN4V-8002-FY.action"
1273 1273  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1274 1274  #
1275 1275  # code: SUN4V-8002-G3
1276 1276  # keys: fault.cpu.generic-sparc.chip-nr
1277 1277  #
1278 1278  msgid "SUN4V-8002-G3.type"
1279 1279  msgstr "Fault"
1280 1280  msgid "SUN4V-8002-G3.severity"
1281 1281  msgstr "Critical"
1282 1282  msgid "SUN4V-8002-G3.description"
1283 1283  msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n  Refer to %s for more information."
1284 1284  msgid "SUN4V-8002-G3.response"
1285 1285  msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1286 1286  msgid "SUN4V-8002-G3.impact"
1287 1287  msgstr "System performance may be affected. \n"
1288 1288  msgid "SUN4V-8002-G3.action"
1289 1289  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1290 1290  #
1291 1291  # code: SUN4V-8002-HR
1292 1292  # keys: fault.cpu.generic-sparc.chip-uc
1293 1293  #
1294 1294  msgid "SUN4V-8002-HR.type"
1295 1295  msgstr "Fault"
1296 1296  msgid "SUN4V-8002-HR.severity"
1297 1297  msgstr "Critical"
1298 1298  msgid "SUN4V-8002-HR.description"
1299 1299  msgstr "This chip has encountered a chip-level uncorrectable error.\n  Refer to %s for more information."
1300 1300  msgid "SUN4V-8002-HR.response"
1301 1301  msgstr "The system will attempt to retire all strands in this chip.\n"
1302 1302  msgid "SUN4V-8002-HR.impact"
1303 1303  msgstr "System performance may be affected. \n"
1304 1304  msgid "SUN4V-8002-HR.action"
1305 1305  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1306 1306  #
1307 1307  # code: SUN4V-8002-J4
1308 1308  # keys: fault.cpu.generic-sparc.chip-uc-nr
1309 1309  #
1310 1310  msgid "SUN4V-8002-J4.type"
1311 1311  msgstr "Fault"
1312 1312  msgid "SUN4V-8002-J4.severity"
1313 1313  msgstr "Critical"
1314 1314  msgid "SUN4V-8002-J4.description"
1315 1315  msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n  Refer to %s for more information."
1316 1316  msgid "SUN4V-8002-J4.response"
1317 1317  msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1318 1318  msgid "SUN4V-8002-J4.impact"
1319 1319  msgstr "System performance may be affected. \n"
1320 1320  msgid "SUN4V-8002-J4.action"
1321 1321  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1322 1322  #
1323 1323  # code: SUN4V-8002-KQ
1324 1324  # keys: fault.cpu.generic-sparc.c2c
1325 1325  #
1326 1326  msgid "SUN4V-8002-KQ.type"
1327 1327  msgstr "Fault"
1328 1328  msgid "SUN4V-8002-KQ.severity"
1329 1329  msgstr "Major"
1330 1330  msgid "SUN4V-8002-KQ.description"
1331 1331  msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n  Refer to %s for more information."
1332 1332  msgid "SUN4V-8002-KQ.response"
1333 1333  msgstr "No automated response.\n"
1334 1334  msgid "SUN4V-8002-KQ.impact"
1335 1335  msgstr "System performance may be affected.\n"
1336 1336  msgid "SUN4V-8002-KQ.action"
1337 1337  msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1338 1338  #
1339 1339  # code: SUN4V-8002-LC
1340 1340  # keys: fault.cpu.generic-sparc.c2c-failover
1341 1341  #
1342 1342  msgid "SUN4V-8002-LC.type"
1343 1343  msgstr "Fault"
1344 1344  msgid "SUN4V-8002-LC.severity"
1345 1345  msgstr "Major"
1346 1346  msgid "SUN4V-8002-LC.description"
1347 1347  msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n  Refer to %s for more information."
1348 1348  msgid "SUN4V-8002-LC.response"
1349 1349  msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1350 1350  msgid "SUN4V-8002-LC.impact"
1351 1351  msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n"
1352 1352  msgid "SUN4V-8002-LC.action"
1353 1353  msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1354 1354  #
1355 1355  # code: SUN4V-8002-MJ
1356 1356  # keys: fault.cpu.generic-sparc.c2c-uc
1357 1357  #
1358 1358  msgid "SUN4V-8002-MJ.type"
1359 1359  msgstr "Fault"
1360 1360  msgid "SUN4V-8002-MJ.severity"
1361 1361  msgstr "Critical"
1362 1362  msgid "SUN4V-8002-MJ.description"
1363 1363  msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n  Refer to %s for more information."
1364 1364  msgid "SUN4V-8002-MJ.response"
1365 1365  msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n"
1366 1366  msgid "SUN4V-8002-MJ.impact"
1367 1367  msgstr "The system halts and must be restarted.  The integrity of this system has\nbeen compromised.\n"
1368 1368  msgid "SUN4V-8002-MJ.action"
1369 1369  msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1370 1370  #
1371 1371  # code: SUN4V-8002-NE
1372 1372  # keys: fault.memory.memlink
1373 1373  #
1374 1374  msgid "SUN4V-8002-NE.type"
1375 1375  msgstr "Fault"
1376 1376  msgid "SUN4V-8002-NE.severity"
1377 1377  msgstr "Major"
1378 1378  msgid "SUN4V-8002-NE.description"
1379 1379  msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller.  No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n  Refer to %s for more information."
1380 1380  msgid "SUN4V-8002-NE.response"
1381 1381  msgstr "The system has recovered from the CRC errors.\n"
1382 1382  msgid "SUN4V-8002-NE.impact"
1383 1383  msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n"
1384 1384  msgid "SUN4V-8002-NE.action"
1385 1385  msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1386 1386  #
1387 1387  # code: SUN4V-8002-PX
1388 1388  # keys: fault.memory.memlink-failover
1389 1389  #
1390 1390  msgid "SUN4V-8002-PX.type"
1391 1391  msgstr "Fault"
1392 1392  msgid "SUN4V-8002-PX.severity"
1393 1393  msgstr "Major"
1394 1394  msgid "SUN4V-8002-PX.description"
1395 1395  msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller.  While no data has been lost, a lane failover\nhas taken place.\n  Refer to %s for more information."
1396 1396  msgid "SUN4V-8002-PX.response"
1397 1397  msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1398 1398  msgid "SUN4V-8002-PX.impact"
1399 1399  msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n"
1400 1400  msgid "SUN4V-8002-PX.action"
1401 1401  msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n"
1402 1402  #
1403 1403  # code: SUN4V-8002-Q2
1404 1404  # keys: fault.memory.memlink-uc
1405 1405  #
1406 1406  msgid "SUN4V-8002-Q2.type"
1407 1407  msgstr "Fault"
1408 1408  msgid "SUN4V-8002-Q2.severity"
1409 1409  msgstr "Critical"
1410 1410  msgid "SUN4V-8002-Q2.description"
1411 1411  msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n  Refer to %s for more information."
1412 1412  msgid "SUN4V-8002-Q2.response"
1413 1413  msgstr "The system crashed to prevent data corruption.  Memory in the affected\npartition may have been deconfigured.  (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n"
1414 1414  msgid "SUN4V-8002-Q2.impact"
1415 1415  msgstr "If memory has been deconfigured, system performance may be impacted. \n"
1416 1416  msgid "SUN4V-8002-Q2.action"
1417 1417  msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n"
1418 1418  #
1419 1419  # code: SUN4V-8002-RA
1420 1420  # keys: defect.fw.generic-sparc.addr-oob
1421 1421  #
1422 1422  msgid "SUN4V-8002-RA.type"
1423 1423  msgstr "Fault"
1424 1424  msgid "SUN4V-8002-RA.severity"
1425 1425  msgstr "Critical"
1426 1426  msgid "SUN4V-8002-RA.description"
1427 1427  msgstr "An address-out-of-bounds error has occurred.\n  Refer to %s for more information."
1428 1428  msgid "SUN4V-8002-RA.response"
1429 1429  msgstr "No automated response.\n"
1430 1430  msgid "SUN4V-8002-RA.impact"
1431 1431  msgstr "The system may have taken a fatal reset.\n"
1432 1432  msgid "SUN4V-8002-RA.action"
1433 1433  msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n"
1434 1434  #
1435 1435  # code: SUN4V-8002-SP
1436 1436  # keys: defect.fw.generic-sparc.erpt-gen
1437 1437  #
1438 1438  msgid "SUN4V-8002-SP.type"
1439 1439  msgstr "Fault"
1440 1440  msgid "SUN4V-8002-SP.severity"
1441 1441  msgstr "Major"
1442 1442  msgid "SUN4V-8002-SP.description"
1443 1443  msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n  Refer to %s for more information."
1444 1444  msgid "SUN4V-8002-SP.response"
1445 1445  msgstr "No automated response.\n"
1446 1446  msgid "SUN4V-8002-SP.impact"
1447 1447  msgstr "This error does not affect system operation.  The error which\ncould not be reported may have more serious impact which cannot be determined.\n"
1448 1448  msgid "SUN4V-8002-SP.action"
1449 1449  msgstr "Call your service provider to determine if your system requires a firmware\nupgrade.  Please retain the error log file.\n"
1450 1450  #
1451 1451  # code: SUN4V-8002-T5
1452 1452  # keys: fault.cpu.generic-sparc.bootbus
1453 1453  #
1454 1454  msgid "SUN4V-8002-T5.type"
1455 1455  msgstr "Fault"
1456 1456  msgid "SUN4V-8002-T5.severity"
1457 1457  msgstr "Critical"
1458 1458  msgid "SUN4V-8002-T5.description"
1459 1459  msgstr "A system boot bus error has occurred.\n  Refer to %s for more information."
1460 1460  msgid "SUN4V-8002-T5.response"
1461 1461  msgstr "No automated response.\n"
1462 1462  msgid "SUN4V-8002-T5.impact"
1463 1463  msgstr "The system's integrity is seriously compromised.  Processor chip(s)\nmay be unavailable.\n"
1464 1464  msgid "SUN4V-8002-T5.action"
1465 1465  msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 1466  #
1467 1467  # code: SUN4V-8002-US
1468 1468  # keys: fault.sp.failed
1469 1469  #
1470 1470  msgid "SUN4V-8002-US.type"
  
    | 
      ↓ open down ↓ | 
    811 lines elided | 
    
      ↑ open up ↑ | 
  
1471 1471  msgstr "Fault"
1472 1472  msgid "SUN4V-8002-US.severity"
1473 1473  msgstr "Critical"
1474 1474  msgid "SUN4V-8002-US.description"
1475 1475  msgstr "The Service Processor failed.\n  Refer to %s for more information."
1476 1476  msgid "SUN4V-8002-US.response"
1477 1477  msgstr "No automated response.\n"
1478 1478  msgid "SUN4V-8002-US.impact"
1479 1479  msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 1480  msgid "SUN4V-8002-US.action"
1481      -msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"
     1481 +msgstr "Schedule a repair procedure for the Service Processor, or contact your illumos distribution team for support.\n"
    
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX