229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
230 msgid "SUN4V-8000-E2.impact"
231 msgstr "Total system memory capacity will be reduced as pages are retired."
232 msgid "SUN4V-8000-E2.action"
233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
234 #
235 # code: SUN4V-8000-FJ
236 # keys: fault.memory.link-c
237 #
238 msgid "SUN4V-8000-FJ.type"
239 msgstr "Fault"
240 msgid "SUN4V-8000-FJ.severity"
241 msgstr "Major"
242 msgid "SUN4V-8000-FJ.description"
243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
244 msgid "SUN4V-8000-FJ.response"
245 msgstr "No automated response.\n"
246 msgid "SUN4V-8000-FJ.impact"
247 msgstr "System performance may be impacted.\n"
248 msgid "SUN4V-8000-FJ.action"
249 msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n"
250 #
251 # code: SUN4V-8000-GE
252 # keys: fault.cpu.ultraSPARC-T2.ireg
253 #
254 msgid "SUN4V-8000-GE.type"
255 msgstr "Fault"
256 msgid "SUN4V-8000-GE.severity"
257 msgstr "Minor"
258 msgid "SUN4V-8000-GE.description"
259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
260 msgid "SUN4V-8000-GE.response"
261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
262 msgid "SUN4V-8000-GE.impact"
263 msgstr "System performance may be affected. \n"
264 msgid "SUN4V-8000-GE.action"
265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
266 #
267 # code: SUN4V-8000-HP
268 # keys: fault.cpu.ultraSPARC-T2.freg
269 #
421 msgstr "No automated response.\n"
422 msgid "SUN4V-8000-SR.impact"
423 msgstr "System performance is likely to be affected. System may be unstable.\n"
424 msgid "SUN4V-8000-SR.action"
425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
426 #
427 # code: SUN4V-8000-TC
428 # keys: fault.memory.link-u
429 #
430 msgid "SUN4V-8000-TC.type"
431 msgstr "Fault"
432 msgid "SUN4V-8000-TC.severity"
433 msgstr "Critical"
434 msgid "SUN4V-8000-TC.description"
435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
436 msgid "SUN4V-8000-TC.response"
437 msgstr "No automated response.\n"
438 msgid "SUN4V-8000-TC.impact"
439 msgstr "System performance may be impacted.\n"
440 msgid "SUN4V-8000-TC.action"
441 msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n"
442 #
443 # code: SUN4V-8000-UQ
444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
445 #
446 msgid "SUN4V-8000-UQ.type"
447 msgstr "Fault"
448 msgid "SUN4V-8000-UQ.severity"
449 msgstr "Critical"
450 msgid "SUN4V-8000-UQ.description"
451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
452 msgid "SUN4V-8000-UQ.response"
453 msgstr "No automated response.\n"
454 msgid "SUN4V-8000-UQ.impact"
455 msgstr "System performance is likely to be affected. \n"
456 msgid "SUN4V-8000-UQ.action"
457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
458 #
459 # code: SUN4V-8000-VE
460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
461 #
481 msgstr "Critical"
482 msgid "SUN4V-8000-WJ.description"
483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
484 msgid "SUN4V-8000-WJ.response"
485 msgstr "No automated response.\n"
486 msgid "SUN4V-8000-WJ.impact"
487 msgstr "System performance is likely to be affected. \n"
488 msgid "SUN4V-8000-WJ.action"
489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
490 #
491 # code: SUN4V-8000-X2
492 # keys: fault.memory.datapath
493 #
494 msgid "SUN4V-8000-X2.type"
495 msgstr "Fault"
496 msgid "SUN4V-8000-X2.severity"
497 msgstr "Major"
498 msgid "SUN4V-8000-X2.description"
499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information."
500 msgid "SUN4V-8000-X2.response"
501 msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
502 msgid "SUN4V-8000-X2.impact"
503 msgstr "System performance and stability may be affected. \n"
504 msgid "SUN4V-8000-X2.action"
505 msgstr "Contact your service provider for further diagnosis.\n"
506 #
507 # code: SUN4V-8000-YX
508 # keys: fault.io.n2.ncu
509 #
510 msgid "SUN4V-8000-YX.type"
511 msgstr "Fault"
512 msgid "SUN4V-8000-YX.severity"
513 msgstr "Critical"
514 msgid "SUN4V-8000-YX.description"
515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information."
516 msgid "SUN4V-8000-YX.response"
517 msgstr "One or more device instances may be disabled\n"
518 msgid "SUN4V-8000-YX.impact"
519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
520 msgid "SUN4V-8000-YX.action"
521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
522 #
523 # code: SUN4V-8001-02
524 # keys: fault.io.n2.dmu
525 #
526 msgid "SUN4V-8001-02.type"
527 msgstr "Fault"
528 msgid "SUN4V-8001-02.severity"
529 msgstr "Critical"
530 msgid "SUN4V-8001-02.description"
531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information."
532 msgid "SUN4V-8001-02.response"
533 msgstr "One or more device instances may be disabled\n"
534 msgid "SUN4V-8001-02.impact"
535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
536 msgid "SUN4V-8001-02.action"
537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
538 #
539 # code: SUN4V-8001-1X
540 # keys: fault.io.n2.niu
541 #
542 msgid "SUN4V-8001-1X.type"
543 msgstr "Fault"
544 msgid "SUN4V-8001-1X.severity"
545 msgstr "Critical"
546 msgid "SUN4V-8001-1X.description"
547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information."
548 msgid "SUN4V-8001-1X.response"
549 msgstr "One or more device instances may be disabled\n"
550 msgid "SUN4V-8001-1X.impact"
551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
552 msgid "SUN4V-8001-1X.action"
553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
554 #
555 # code: SUN4V-8001-2E
556 # keys: fault.io.n2.siu
557 #
558 msgid "SUN4V-8001-2E.type"
559 msgstr "Fault"
560 msgid "SUN4V-8001-2E.severity"
561 msgstr "Critical"
562 msgid "SUN4V-8001-2E.description"
563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information."
564 msgid "SUN4V-8001-2E.response"
565 msgstr "One or more device instances may be disabled\n"
566 msgid "SUN4V-8001-2E.impact"
567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
568 msgid "SUN4V-8001-2E.action"
569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
570 #
571 # code: SUN4V-8001-3J
572 # keys: fault.io.n2.soc
573 #
574 msgid "SUN4V-8001-3J.type"
575 msgstr "Fault"
576 msgid "SUN4V-8001-3J.severity"
577 msgstr "Critical"
578 msgid "SUN4V-8001-3J.description"
579 msgstr "A problem was detected in N2's SOC\n Refer to %s for more information."
580 msgid "SUN4V-8001-3J.response"
581 msgstr "One or more device instances may be disabled\n"
582 msgid "SUN4V-8001-3J.impact"
583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
584 msgid "SUN4V-8001-3J.action"
585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
586 #
587 # code: SUN4V-8001-4C
588 # keys: fault.io.n2.crossbar
589 #
590 msgid "SUN4V-8001-4C.type"
591 msgstr "Fault"
592 msgid "SUN4V-8001-4C.severity"
593 msgstr "Critical"
594 msgid "SUN4V-8001-4C.description"
595 msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information."
596 msgid "SUN4V-8001-4C.response"
597 msgstr "One or more device instances may be disabled\n"
598 msgid "SUN4V-8001-4C.impact"
599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
600 msgid "SUN4V-8001-4C.action"
601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
602 #
603 # code: SUN4V-8001-5Q
604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
605 #
606 msgid "SUN4V-8001-5Q.type"
607 msgstr "Fault"
608 msgid "SUN4V-8001-5Q.severity"
609 msgstr "Critical"
610 msgid "SUN4V-8001-5Q.description"
611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n Refer to %s for more information."
612 msgid "SUN4V-8001-5Q.response"
613 msgstr "One or more device instances may be disabled\n"
614 msgid "SUN4V-8001-5Q.impact"
615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
616 msgid "SUN4V-8001-5Q.action"
617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
618 #
619 # code: SUN4V-8001-64
620 # keys: fault.io.vf.ncx
621 #
622 msgid "SUN4V-8001-64.type"
623 msgstr "Fault"
624 msgid "SUN4V-8001-64.severity"
625 msgstr "Critical"
626 msgid "SUN4V-8001-64.description"
627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n Refer to %s for more information."
628 msgid "SUN4V-8001-64.response"
629 msgstr "One or more device instances may be disabled\n"
630 msgid "SUN4V-8001-64.impact"
631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
632 msgid "SUN4V-8001-64.action"
633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
634 #
635 # code: SUN4V-8001-7R
636 # keys: fault.memory.link-f
637 #
638 msgid "SUN4V-8001-7R.type"
639 msgstr "Fault"
640 msgid "SUN4V-8001-7R.severity"
641 msgstr "Major"
642 msgid "SUN4V-8001-7R.description"
643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. A lane failover has taken place.\n Refer to %s for more information."
644 msgid "SUN4V-8001-7R.response"
645 msgstr "No automated response.\n"
646 msgid "SUN4V-8001-7R.impact"
647 msgstr "System performance may be impacted.\n"
648 msgid "SUN4V-8001-7R.action"
649 msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n"
650 #
651 # code: SUN4V-8001-8H
652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
653 #
654 msgid "SUN4V-8001-8H.type"
655 msgstr "Fault"
656 msgid "SUN4V-8001-8H.severity"
657 msgstr "Minor"
658 msgid "SUN4V-8001-8H.description"
659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
660 msgid "SUN4V-8001-8H.response"
661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
662 msgid "SUN4V-8001-8H.impact"
663 msgstr "System performance may be affected. \n"
664 msgid "SUN4V-8001-8H.action"
665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
666 #
667 # code: SUN4V-8001-9D
668 # keys: fault.cpu.ultraSPARC-T2plus.freg
669 #
1461 msgstr "No automated response.\n"
1462 msgid "SUN4V-8002-T5.impact"
1463 msgstr "The system's integrity is seriously compromised. Processor chip(s)\nmay be unavailable.\n"
1464 msgid "SUN4V-8002-T5.action"
1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 #
1467 # code: SUN4V-8002-US
1468 # keys: fault.sp.failed
1469 #
1470 msgid "SUN4V-8002-US.type"
1471 msgstr "Fault"
1472 msgid "SUN4V-8002-US.severity"
1473 msgstr "Critical"
1474 msgid "SUN4V-8002-US.description"
1475 msgstr "The Service Processor failed.\n Refer to %s for more information."
1476 msgid "SUN4V-8002-US.response"
1477 msgstr "No automated response.\n"
1478 msgid "SUN4V-8002-US.impact"
1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 msgid "SUN4V-8002-US.action"
1481 msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"
|
229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
230 msgid "SUN4V-8000-E2.impact"
231 msgstr "Total system memory capacity will be reduced as pages are retired."
232 msgid "SUN4V-8000-E2.action"
233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
234 #
235 # code: SUN4V-8000-FJ
236 # keys: fault.memory.link-c
237 #
238 msgid "SUN4V-8000-FJ.type"
239 msgstr "Fault"
240 msgid "SUN4V-8000-FJ.severity"
241 msgstr "Major"
242 msgid "SUN4V-8000-FJ.description"
243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
244 msgid "SUN4V-8000-FJ.response"
245 msgstr "No automated response.\n"
246 msgid "SUN4V-8000-FJ.impact"
247 msgstr "System performance may be impacted.\n"
248 msgid "SUN4V-8000-FJ.action"
249 msgstr "At a convenient time, try reseating the memory module(s). If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
250 #
251 # code: SUN4V-8000-GE
252 # keys: fault.cpu.ultraSPARC-T2.ireg
253 #
254 msgid "SUN4V-8000-GE.type"
255 msgstr "Fault"
256 msgid "SUN4V-8000-GE.severity"
257 msgstr "Minor"
258 msgid "SUN4V-8000-GE.description"
259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
260 msgid "SUN4V-8000-GE.response"
261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
262 msgid "SUN4V-8000-GE.impact"
263 msgstr "System performance may be affected. \n"
264 msgid "SUN4V-8000-GE.action"
265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
266 #
267 # code: SUN4V-8000-HP
268 # keys: fault.cpu.ultraSPARC-T2.freg
269 #
421 msgstr "No automated response.\n"
422 msgid "SUN4V-8000-SR.impact"
423 msgstr "System performance is likely to be affected. System may be unstable.\n"
424 msgid "SUN4V-8000-SR.action"
425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
426 #
427 # code: SUN4V-8000-TC
428 # keys: fault.memory.link-u
429 #
430 msgid "SUN4V-8000-TC.type"
431 msgstr "Fault"
432 msgid "SUN4V-8000-TC.severity"
433 msgstr "Critical"
434 msgid "SUN4V-8000-TC.description"
435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
436 msgid "SUN4V-8000-TC.response"
437 msgstr "No automated response.\n"
438 msgid "SUN4V-8000-TC.impact"
439 msgstr "System performance may be impacted.\n"
440 msgid "SUN4V-8000-TC.action"
441 msgstr "At a convenient time, try reseating the memory module. If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
442 #
443 # code: SUN4V-8000-UQ
444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
445 #
446 msgid "SUN4V-8000-UQ.type"
447 msgstr "Fault"
448 msgid "SUN4V-8000-UQ.severity"
449 msgstr "Critical"
450 msgid "SUN4V-8000-UQ.description"
451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
452 msgid "SUN4V-8000-UQ.response"
453 msgstr "No automated response.\n"
454 msgid "SUN4V-8000-UQ.impact"
455 msgstr "System performance is likely to be affected. \n"
456 msgid "SUN4V-8000-UQ.action"
457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
458 #
459 # code: SUN4V-8000-VE
460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
461 #
481 msgstr "Critical"
482 msgid "SUN4V-8000-WJ.description"
483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
484 msgid "SUN4V-8000-WJ.response"
485 msgstr "No automated response.\n"
486 msgid "SUN4V-8000-WJ.impact"
487 msgstr "System performance is likely to be affected. \n"
488 msgid "SUN4V-8000-WJ.action"
489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
490 #
491 # code: SUN4V-8000-X2
492 # keys: fault.memory.datapath
493 #
494 msgid "SUN4V-8000-X2.type"
495 msgstr "Fault"
496 msgid "SUN4V-8000-X2.severity"
497 msgstr "Major"
498 msgid "SUN4V-8000-X2.description"
499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information."
500 msgid "SUN4V-8000-X2.response"
501 msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n"
502 msgid "SUN4V-8000-X2.impact"
503 msgstr "System performance and stability may be affected. \n"
504 msgid "SUN4V-8000-X2.action"
505 msgstr "Contact your service provider for further diagnosis.\n"
506 #
507 # code: SUN4V-8000-YX
508 # keys: fault.io.n2.ncu
509 #
510 msgid "SUN4V-8000-YX.type"
511 msgstr "Fault"
512 msgid "SUN4V-8000-YX.severity"
513 msgstr "Critical"
514 msgid "SUN4V-8000-YX.description"
515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information."
516 msgid "SUN4V-8000-YX.response"
517 msgstr "One or more device instances may be disabled\n"
518 msgid "SUN4V-8000-YX.impact"
519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
520 msgid "SUN4V-8000-YX.action"
521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n"
522 #
523 # code: SUN4V-8001-02
524 # keys: fault.io.n2.dmu
525 #
526 msgid "SUN4V-8001-02.type"
527 msgstr "Fault"
528 msgid "SUN4V-8001-02.severity"
529 msgstr "Critical"
530 msgid "SUN4V-8001-02.description"
531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information."
532 msgid "SUN4V-8001-02.response"
533 msgstr "One or more device instances may be disabled\n"
534 msgid "SUN4V-8001-02.impact"
535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
536 msgid "SUN4V-8001-02.action"
537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
538 #
539 # code: SUN4V-8001-1X
540 # keys: fault.io.n2.niu
541 #
542 msgid "SUN4V-8001-1X.type"
543 msgstr "Fault"
544 msgid "SUN4V-8001-1X.severity"
545 msgstr "Critical"
546 msgid "SUN4V-8001-1X.description"
547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information."
548 msgid "SUN4V-8001-1X.response"
549 msgstr "One or more device instances may be disabled\n"
550 msgid "SUN4V-8001-1X.impact"
551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
552 msgid "SUN4V-8001-1X.action"
553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
554 #
555 # code: SUN4V-8001-2E
556 # keys: fault.io.n2.siu
557 #
558 msgid "SUN4V-8001-2E.type"
559 msgstr "Fault"
560 msgid "SUN4V-8001-2E.severity"
561 msgstr "Critical"
562 msgid "SUN4V-8001-2E.description"
563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information."
564 msgid "SUN4V-8001-2E.response"
565 msgstr "One or more device instances may be disabled\n"
566 msgid "SUN4V-8001-2E.impact"
567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
568 msgid "SUN4V-8001-2E.action"
569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
570 #
571 # code: SUN4V-8001-3J
572 # keys: fault.io.n2.soc
573 #
574 msgid "SUN4V-8001-3J.type"
575 msgstr "Fault"
576 msgid "SUN4V-8001-3J.severity"
577 msgstr "Critical"
578 msgid "SUN4V-8001-3J.description"
579 msgstr "A problem was detected in N2's SOC\n Refer to %s for more information."
580 msgid "SUN4V-8001-3J.response"
581 msgstr "One or more device instances may be disabled\n"
582 msgid "SUN4V-8001-3J.impact"
583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
584 msgid "SUN4V-8001-3J.action"
585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
586 #
587 # code: SUN4V-8001-4C
588 # keys: fault.io.n2.crossbar
589 #
590 msgid "SUN4V-8001-4C.type"
591 msgstr "Fault"
592 msgid "SUN4V-8001-4C.severity"
593 msgstr "Critical"
594 msgid "SUN4V-8001-4C.description"
595 msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information."
596 msgid "SUN4V-8001-4C.response"
597 msgstr "One or more device instances may be disabled\n"
598 msgid "SUN4V-8001-4C.impact"
599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
600 msgid "SUN4V-8001-4C.action"
601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
602 #
603 # code: SUN4V-8001-5Q
604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
605 #
606 msgid "SUN4V-8001-5Q.type"
607 msgstr "Fault"
608 msgid "SUN4V-8001-5Q.severity"
609 msgstr "Critical"
610 msgid "SUN4V-8001-5Q.description"
611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n Refer to %s for more information."
612 msgid "SUN4V-8001-5Q.response"
613 msgstr "One or more device instances may be disabled\n"
614 msgid "SUN4V-8001-5Q.impact"
615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
616 msgid "SUN4V-8001-5Q.action"
617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
618 #
619 # code: SUN4V-8001-64
620 # keys: fault.io.vf.ncx
621 #
622 msgid "SUN4V-8001-64.type"
623 msgstr "Fault"
624 msgid "SUN4V-8001-64.severity"
625 msgstr "Critical"
626 msgid "SUN4V-8001-64.description"
627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n Refer to %s for more information."
628 msgid "SUN4V-8001-64.response"
629 msgstr "One or more device instances may be disabled\n"
630 msgid "SUN4V-8001-64.impact"
631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
632 msgid "SUN4V-8001-64.action"
633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
634 #
635 # code: SUN4V-8001-7R
636 # keys: fault.memory.link-f
637 #
638 msgid "SUN4V-8001-7R.type"
639 msgstr "Fault"
640 msgid "SUN4V-8001-7R.severity"
641 msgstr "Major"
642 msgid "SUN4V-8001-7R.description"
643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. A lane failover has taken place.\n Refer to %s for more information."
644 msgid "SUN4V-8001-7R.response"
645 msgstr "No automated response.\n"
646 msgid "SUN4V-8001-7R.impact"
647 msgstr "System performance may be impacted.\n"
648 msgid "SUN4V-8001-7R.action"
649 msgstr "At a convenient time, try reseating the memory module(s). If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
650 #
651 # code: SUN4V-8001-8H
652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
653 #
654 msgid "SUN4V-8001-8H.type"
655 msgstr "Fault"
656 msgid "SUN4V-8001-8H.severity"
657 msgstr "Minor"
658 msgid "SUN4V-8001-8H.description"
659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
660 msgid "SUN4V-8001-8H.response"
661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
662 msgid "SUN4V-8001-8H.impact"
663 msgstr "System performance may be affected. \n"
664 msgid "SUN4V-8001-8H.action"
665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
666 #
667 # code: SUN4V-8001-9D
668 # keys: fault.cpu.ultraSPARC-T2plus.freg
669 #
1461 msgstr "No automated response.\n"
1462 msgid "SUN4V-8002-T5.impact"
1463 msgstr "The system's integrity is seriously compromised. Processor chip(s)\nmay be unavailable.\n"
1464 msgid "SUN4V-8002-T5.action"
1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 #
1467 # code: SUN4V-8002-US
1468 # keys: fault.sp.failed
1469 #
1470 msgid "SUN4V-8002-US.type"
1471 msgstr "Fault"
1472 msgid "SUN4V-8002-US.severity"
1473 msgstr "Critical"
1474 msgid "SUN4V-8002-US.description"
1475 msgstr "The Service Processor failed.\n Refer to %s for more information."
1476 msgid "SUN4V-8002-US.response"
1477 msgstr "No automated response.\n"
1478 msgid "SUN4V-8002-US.impact"
1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 msgid "SUN4V-8002-US.action"
1481 msgstr "Schedule a repair procedure for the Service Processor, or contact your illumos distribution team for support.\n"
|