229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
 230 msgid "SUN4V-8000-E2.impact"
 231 msgstr "Total system memory capacity will be reduced as pages are retired."
 232 msgid "SUN4V-8000-E2.action"
 233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
 234 #
 235 # code: SUN4V-8000-FJ
 236 # keys: fault.memory.link-c
 237 #
 238 msgid "SUN4V-8000-FJ.type"
 239 msgstr "Fault"
 240 msgid "SUN4V-8000-FJ.severity"
 241 msgstr "Major"
 242 msgid "SUN4V-8000-FJ.description"
 243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 244 msgid "SUN4V-8000-FJ.response"
 245 msgstr "No automated response.\n"
 246 msgid "SUN4V-8000-FJ.impact"
 247 msgstr "System performance may be impacted.\n"
 248 msgid "SUN4V-8000-FJ.action"
 249 msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
 250 #
 251 # code: SUN4V-8000-GE
 252 # keys: fault.cpu.ultraSPARC-T2.ireg
 253 #
 254 msgid "SUN4V-8000-GE.type"
 255 msgstr "Fault"
 256 msgid "SUN4V-8000-GE.severity"
 257 msgstr "Minor"
 258 msgid "SUN4V-8000-GE.description"
 259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 260 msgid "SUN4V-8000-GE.response"
 261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 262 msgid "SUN4V-8000-GE.impact"
 263 msgstr "System performance may be affected. \n"
 264 msgid "SUN4V-8000-GE.action"
 265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 266 #
 267 # code: SUN4V-8000-HP
 268 # keys: fault.cpu.ultraSPARC-T2.freg
 269 #
 
 
 421 msgstr "No automated response.\n"
 422 msgid "SUN4V-8000-SR.impact"
 423 msgstr "System performance is likely to be affected. System may be unstable.\n"
 424 msgid "SUN4V-8000-SR.action"
 425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 426 #
 427 # code: SUN4V-8000-TC
 428 # keys: fault.memory.link-u
 429 #
 430 msgid "SUN4V-8000-TC.type"
 431 msgstr "Fault"
 432 msgid "SUN4V-8000-TC.severity"
 433 msgstr "Critical"
 434 msgid "SUN4V-8000-TC.description"
 435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 436 msgid "SUN4V-8000-TC.response"
 437 msgstr "No automated response.\n"
 438 msgid "SUN4V-8000-TC.impact"
 439 msgstr "System performance may be impacted.\n"
 440 msgid "SUN4V-8000-TC.action"
 441 msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
 442 #
 443 # code: SUN4V-8000-UQ
 444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
 445 #
 446 msgid "SUN4V-8000-UQ.type"
 447 msgstr "Fault"
 448 msgid "SUN4V-8000-UQ.severity"
 449 msgstr "Critical"
 450 msgid "SUN4V-8000-UQ.description"
 451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 452 msgid "SUN4V-8000-UQ.response"
 453 msgstr "No automated response.\n"
 454 msgid "SUN4V-8000-UQ.impact"
 455 msgstr "System performance is likely to be affected. \n"
 456 msgid "SUN4V-8000-UQ.action"
 457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 458 #
 459 # code: SUN4V-8000-VE
 460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
 461 #
 
 
 481 msgstr "Critical"
 482 msgid "SUN4V-8000-WJ.description"
 483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 484 msgid "SUN4V-8000-WJ.response"
 485 msgstr "No automated response.\n"
 486 msgid "SUN4V-8000-WJ.impact"
 487 msgstr "System performance is likely to be affected. \n"
 488 msgid "SUN4V-8000-WJ.action"
 489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 490 #
 491 # code: SUN4V-8000-X2
 492 # keys: fault.memory.datapath
 493 #
 494 msgid "SUN4V-8000-X2.type"
 495 msgstr "Fault"
 496 msgid "SUN4V-8000-X2.severity"
 497 msgstr "Major"
 498 msgid "SUN4V-8000-X2.description"
 499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
 500 msgid "SUN4V-8000-X2.response"
 501 msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
 502 msgid "SUN4V-8000-X2.impact"
 503 msgstr "System performance and stability may be affected. \n"
 504 msgid "SUN4V-8000-X2.action"
 505 msgstr "Contact your service provider for further diagnosis.\n"
 506 #
 507 # code: SUN4V-8000-YX
 508 # keys: fault.io.n2.ncu
 509 #
 510 msgid "SUN4V-8000-YX.type"
 511 msgstr "Fault"
 512 msgid "SUN4V-8000-YX.severity"
 513 msgstr "Critical"
 514 msgid "SUN4V-8000-YX.description"
 515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
 516 msgid "SUN4V-8000-YX.response"
 517 msgstr "One or more device instances may be disabled\n"
 518 msgid "SUN4V-8000-YX.impact"
 519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 520 msgid "SUN4V-8000-YX.action"
 521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 522 #
 523 # code: SUN4V-8001-02
 524 # keys: fault.io.n2.dmu
 525 #
 526 msgid "SUN4V-8001-02.type"
 527 msgstr "Fault"
 528 msgid "SUN4V-8001-02.severity"
 529 msgstr "Critical"
 530 msgid "SUN4V-8001-02.description"
 531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
 532 msgid "SUN4V-8001-02.response"
 533 msgstr "One or more device instances may be disabled\n"
 534 msgid "SUN4V-8001-02.impact"
 535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 536 msgid "SUN4V-8001-02.action"
 537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 538 #
 539 # code: SUN4V-8001-1X
 540 # keys: fault.io.n2.niu
 541 #
 542 msgid "SUN4V-8001-1X.type"
 543 msgstr "Fault"
 544 msgid "SUN4V-8001-1X.severity"
 545 msgstr "Critical"
 546 msgid "SUN4V-8001-1X.description"
 547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
 548 msgid "SUN4V-8001-1X.response"
 549 msgstr "One or more device instances may be disabled\n"
 550 msgid "SUN4V-8001-1X.impact"
 551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 552 msgid "SUN4V-8001-1X.action"
 553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 554 #
 555 # code: SUN4V-8001-2E
 556 # keys: fault.io.n2.siu
 557 #
 558 msgid "SUN4V-8001-2E.type"
 559 msgstr "Fault"
 560 msgid "SUN4V-8001-2E.severity"
 561 msgstr "Critical"
 562 msgid "SUN4V-8001-2E.description"
 563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
 564 msgid "SUN4V-8001-2E.response"
 565 msgstr "One or more device instances may be disabled\n"
 566 msgid "SUN4V-8001-2E.impact"
 567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 568 msgid "SUN4V-8001-2E.action"
 569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 570 #
 571 # code: SUN4V-8001-3J
 572 # keys: fault.io.n2.soc
 573 #
 574 msgid "SUN4V-8001-3J.type"
 575 msgstr "Fault"
 576 msgid "SUN4V-8001-3J.severity"
 577 msgstr "Critical"
 578 msgid "SUN4V-8001-3J.description"
 579 msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
 580 msgid "SUN4V-8001-3J.response"
 581 msgstr "One or more device instances may be disabled\n"
 582 msgid "SUN4V-8001-3J.impact"
 583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 584 msgid "SUN4V-8001-3J.action"
 585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 586 #
 587 # code: SUN4V-8001-4C
 588 # keys: fault.io.n2.crossbar
 589 #
 590 msgid "SUN4V-8001-4C.type"
 591 msgstr "Fault"
 592 msgid "SUN4V-8001-4C.severity"
 593 msgstr "Critical"
 594 msgid "SUN4V-8001-4C.description"
 595 msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
 596 msgid "SUN4V-8001-4C.response"
 597 msgstr "One or more device instances may be disabled\n"
 598 msgid "SUN4V-8001-4C.impact"
 599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 600 msgid "SUN4V-8001-4C.action"
 601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 602 #
 603 # code: SUN4V-8001-5Q
 604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
 605 #
 606 msgid "SUN4V-8001-5Q.type"
 607 msgstr "Fault"
 608 msgid "SUN4V-8001-5Q.severity"
 609 msgstr "Critical"
 610 msgid "SUN4V-8001-5Q.description"
 611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
 612 msgid "SUN4V-8001-5Q.response"
 613 msgstr "One or more device instances may be disabled\n"
 614 msgid "SUN4V-8001-5Q.impact"
 615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 616 msgid "SUN4V-8001-5Q.action"
 617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 618 #
 619 # code: SUN4V-8001-64
 620 # keys: fault.io.vf.ncx
 621 #
 622 msgid "SUN4V-8001-64.type"
 623 msgstr "Fault"
 624 msgid "SUN4V-8001-64.severity"
 625 msgstr "Critical"
 626 msgid "SUN4V-8001-64.description"
 627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
 628 msgid "SUN4V-8001-64.response"
 629 msgstr "One or more device instances may be disabled\n"
 630 msgid "SUN4V-8001-64.impact"
 631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 632 msgid "SUN4V-8001-64.action"
 633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 634 #
 635 # code: SUN4V-8001-7R
 636 # keys: fault.memory.link-f
 637 #
 638 msgid "SUN4V-8001-7R.type"
 639 msgstr "Fault"
 640 msgid "SUN4V-8001-7R.severity"
 641 msgstr "Major"
 642 msgid "SUN4V-8001-7R.description"
 643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
 644 msgid "SUN4V-8001-7R.response"
 645 msgstr "No automated response.\n"
 646 msgid "SUN4V-8001-7R.impact"
 647 msgstr "System performance may be impacted.\n"
 648 msgid "SUN4V-8001-7R.action"
 649 msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
 650 #
 651 # code: SUN4V-8001-8H
 652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
 653 #
 654 msgid "SUN4V-8001-8H.type"
 655 msgstr "Fault"
 656 msgid "SUN4V-8001-8H.severity"
 657 msgstr "Minor"
 658 msgid "SUN4V-8001-8H.description"
 659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 660 msgid "SUN4V-8001-8H.response"
 661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 662 msgid "SUN4V-8001-8H.impact"
 663 msgstr "System performance may be affected. \n"
 664 msgid "SUN4V-8001-8H.action"
 665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 666 #
 667 # code: SUN4V-8001-9D
 668 # keys: fault.cpu.ultraSPARC-T2plus.freg
 669 #
 
 
1461 msgstr "No automated response.\n"
1462 msgid "SUN4V-8002-T5.impact"
1463 msgstr "The system's integrity is seriously compromised.  Processor chip(s)\nmay be unavailable.\n"
1464 msgid "SUN4V-8002-T5.action"
1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 #
1467 # code: SUN4V-8002-US
1468 # keys: fault.sp.failed
1469 #
1470 msgid "SUN4V-8002-US.type"
1471 msgstr "Fault"
1472 msgid "SUN4V-8002-US.severity"
1473 msgstr "Critical"
1474 msgid "SUN4V-8002-US.description"
1475 msgstr "The Service Processor failed.\n  Refer to %s for more information."
1476 msgid "SUN4V-8002-US.response"
1477 msgstr "No automated response.\n"
1478 msgid "SUN4V-8002-US.impact"
1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 msgid "SUN4V-8002-US.action"
1481 msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"
  | 
 
 
 229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
 230 msgid "SUN4V-8000-E2.impact"
 231 msgstr "Total system memory capacity will be reduced as pages are retired."
 232 msgid "SUN4V-8000-E2.action"
 233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
 234 #
 235 # code: SUN4V-8000-FJ
 236 # keys: fault.memory.link-c
 237 #
 238 msgid "SUN4V-8000-FJ.type"
 239 msgstr "Fault"
 240 msgid "SUN4V-8000-FJ.severity"
 241 msgstr "Major"
 242 msgid "SUN4V-8000-FJ.description"
 243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 244 msgid "SUN4V-8000-FJ.response"
 245 msgstr "No automated response.\n"
 246 msgid "SUN4V-8000-FJ.impact"
 247 msgstr "System performance may be impacted.\n"
 248 msgid "SUN4V-8000-FJ.action"
 249 msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 250 #
 251 # code: SUN4V-8000-GE
 252 # keys: fault.cpu.ultraSPARC-T2.ireg
 253 #
 254 msgid "SUN4V-8000-GE.type"
 255 msgstr "Fault"
 256 msgid "SUN4V-8000-GE.severity"
 257 msgstr "Minor"
 258 msgid "SUN4V-8000-GE.description"
 259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 260 msgid "SUN4V-8000-GE.response"
 261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 262 msgid "SUN4V-8000-GE.impact"
 263 msgstr "System performance may be affected. \n"
 264 msgid "SUN4V-8000-GE.action"
 265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 266 #
 267 # code: SUN4V-8000-HP
 268 # keys: fault.cpu.ultraSPARC-T2.freg
 269 #
 
 
 421 msgstr "No automated response.\n"
 422 msgid "SUN4V-8000-SR.impact"
 423 msgstr "System performance is likely to be affected. System may be unstable.\n"
 424 msgid "SUN4V-8000-SR.action"
 425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 426 #
 427 # code: SUN4V-8000-TC
 428 # keys: fault.memory.link-u
 429 #
 430 msgid "SUN4V-8000-TC.type"
 431 msgstr "Fault"
 432 msgid "SUN4V-8000-TC.severity"
 433 msgstr "Critical"
 434 msgid "SUN4V-8000-TC.description"
 435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 436 msgid "SUN4V-8000-TC.response"
 437 msgstr "No automated response.\n"
 438 msgid "SUN4V-8000-TC.impact"
 439 msgstr "System performance may be impacted.\n"
 440 msgid "SUN4V-8000-TC.action"
 441 msgstr "At a convenient time, try reseating the memory module.  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 442 #
 443 # code: SUN4V-8000-UQ
 444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
 445 #
 446 msgid "SUN4V-8000-UQ.type"
 447 msgstr "Fault"
 448 msgid "SUN4V-8000-UQ.severity"
 449 msgstr "Critical"
 450 msgid "SUN4V-8000-UQ.description"
 451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 452 msgid "SUN4V-8000-UQ.response"
 453 msgstr "No automated response.\n"
 454 msgid "SUN4V-8000-UQ.impact"
 455 msgstr "System performance is likely to be affected. \n"
 456 msgid "SUN4V-8000-UQ.action"
 457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 458 #
 459 # code: SUN4V-8000-VE
 460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
 461 #
 
 
 481 msgstr "Critical"
 482 msgid "SUN4V-8000-WJ.description"
 483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 484 msgid "SUN4V-8000-WJ.response"
 485 msgstr "No automated response.\n"
 486 msgid "SUN4V-8000-WJ.impact"
 487 msgstr "System performance is likely to be affected. \n"
 488 msgid "SUN4V-8000-WJ.action"
 489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 490 #
 491 # code: SUN4V-8000-X2
 492 # keys: fault.memory.datapath
 493 #
 494 msgid "SUN4V-8000-X2.type"
 495 msgstr "Fault"
 496 msgid "SUN4V-8000-X2.severity"
 497 msgstr "Major"
 498 msgid "SUN4V-8000-X2.description"
 499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
 500 msgid "SUN4V-8000-X2.response"
 501 msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n"
 502 msgid "SUN4V-8000-X2.impact"
 503 msgstr "System performance and stability may be affected. \n"
 504 msgid "SUN4V-8000-X2.action"
 505 msgstr "Contact your service provider for further diagnosis.\n"
 506 #
 507 # code: SUN4V-8000-YX
 508 # keys: fault.io.n2.ncu
 509 #
 510 msgid "SUN4V-8000-YX.type"
 511 msgstr "Fault"
 512 msgid "SUN4V-8000-YX.severity"
 513 msgstr "Critical"
 514 msgid "SUN4V-8000-YX.description"
 515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
 516 msgid "SUN4V-8000-YX.response"
 517 msgstr "One or more device instances may be disabled\n"
 518 msgid "SUN4V-8000-YX.impact"
 519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 520 msgid "SUN4V-8000-YX.action"
 521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n"
 522 #
 523 # code: SUN4V-8001-02
 524 # keys: fault.io.n2.dmu
 525 #
 526 msgid "SUN4V-8001-02.type"
 527 msgstr "Fault"
 528 msgid "SUN4V-8001-02.severity"
 529 msgstr "Critical"
 530 msgid "SUN4V-8001-02.description"
 531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
 532 msgid "SUN4V-8001-02.response"
 533 msgstr "One or more device instances may be disabled\n"
 534 msgid "SUN4V-8001-02.impact"
 535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 536 msgid "SUN4V-8001-02.action"
 537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 538 #
 539 # code: SUN4V-8001-1X
 540 # keys: fault.io.n2.niu
 541 #
 542 msgid "SUN4V-8001-1X.type"
 543 msgstr "Fault"
 544 msgid "SUN4V-8001-1X.severity"
 545 msgstr "Critical"
 546 msgid "SUN4V-8001-1X.description"
 547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
 548 msgid "SUN4V-8001-1X.response"
 549 msgstr "One or more device instances may be disabled\n"
 550 msgid "SUN4V-8001-1X.impact"
 551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 552 msgid "SUN4V-8001-1X.action"
 553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 554 #
 555 # code: SUN4V-8001-2E
 556 # keys: fault.io.n2.siu
 557 #
 558 msgid "SUN4V-8001-2E.type"
 559 msgstr "Fault"
 560 msgid "SUN4V-8001-2E.severity"
 561 msgstr "Critical"
 562 msgid "SUN4V-8001-2E.description"
 563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
 564 msgid "SUN4V-8001-2E.response"
 565 msgstr "One or more device instances may be disabled\n"
 566 msgid "SUN4V-8001-2E.impact"
 567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 568 msgid "SUN4V-8001-2E.action"
 569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 570 #
 571 # code: SUN4V-8001-3J
 572 # keys: fault.io.n2.soc
 573 #
 574 msgid "SUN4V-8001-3J.type"
 575 msgstr "Fault"
 576 msgid "SUN4V-8001-3J.severity"
 577 msgstr "Critical"
 578 msgid "SUN4V-8001-3J.description"
 579 msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
 580 msgid "SUN4V-8001-3J.response"
 581 msgstr "One or more device instances may be disabled\n"
 582 msgid "SUN4V-8001-3J.impact"
 583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 584 msgid "SUN4V-8001-3J.action"
 585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 586 #
 587 # code: SUN4V-8001-4C
 588 # keys: fault.io.n2.crossbar
 589 #
 590 msgid "SUN4V-8001-4C.type"
 591 msgstr "Fault"
 592 msgid "SUN4V-8001-4C.severity"
 593 msgstr "Critical"
 594 msgid "SUN4V-8001-4C.description"
 595 msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
 596 msgid "SUN4V-8001-4C.response"
 597 msgstr "One or more device instances may be disabled\n"
 598 msgid "SUN4V-8001-4C.impact"
 599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 600 msgid "SUN4V-8001-4C.action"
 601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 602 #
 603 # code: SUN4V-8001-5Q
 604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
 605 #
 606 msgid "SUN4V-8001-5Q.type"
 607 msgstr "Fault"
 608 msgid "SUN4V-8001-5Q.severity"
 609 msgstr "Critical"
 610 msgid "SUN4V-8001-5Q.description"
 611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
 612 msgid "SUN4V-8001-5Q.response"
 613 msgstr "One or more device instances may be disabled\n"
 614 msgid "SUN4V-8001-5Q.impact"
 615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 616 msgid "SUN4V-8001-5Q.action"
 617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 618 #
 619 # code: SUN4V-8001-64
 620 # keys: fault.io.vf.ncx
 621 #
 622 msgid "SUN4V-8001-64.type"
 623 msgstr "Fault"
 624 msgid "SUN4V-8001-64.severity"
 625 msgstr "Critical"
 626 msgid "SUN4V-8001-64.description"
 627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
 628 msgid "SUN4V-8001-64.response"
 629 msgstr "One or more device instances may be disabled\n"
 630 msgid "SUN4V-8001-64.impact"
 631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 632 msgid "SUN4V-8001-64.action"
 633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 634 #
 635 # code: SUN4V-8001-7R
 636 # keys: fault.memory.link-f
 637 #
 638 msgid "SUN4V-8001-7R.type"
 639 msgstr "Fault"
 640 msgid "SUN4V-8001-7R.severity"
 641 msgstr "Major"
 642 msgid "SUN4V-8001-7R.description"
 643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
 644 msgid "SUN4V-8001-7R.response"
 645 msgstr "No automated response.\n"
 646 msgid "SUN4V-8001-7R.impact"
 647 msgstr "System performance may be impacted.\n"
 648 msgid "SUN4V-8001-7R.action"
 649 msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 650 #
 651 # code: SUN4V-8001-8H
 652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
 653 #
 654 msgid "SUN4V-8001-8H.type"
 655 msgstr "Fault"
 656 msgid "SUN4V-8001-8H.severity"
 657 msgstr "Minor"
 658 msgid "SUN4V-8001-8H.description"
 659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 660 msgid "SUN4V-8001-8H.response"
 661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 662 msgid "SUN4V-8001-8H.impact"
 663 msgstr "System performance may be affected. \n"
 664 msgid "SUN4V-8001-8H.action"
 665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 666 #
 667 # code: SUN4V-8001-9D
 668 # keys: fault.cpu.ultraSPARC-T2plus.freg
 669 #
 
 
1461 msgstr "No automated response.\n"
1462 msgid "SUN4V-8002-T5.impact"
1463 msgstr "The system's integrity is seriously compromised.  Processor chip(s)\nmay be unavailable.\n"
1464 msgid "SUN4V-8002-T5.action"
1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 #
1467 # code: SUN4V-8002-US
1468 # keys: fault.sp.failed
1469 #
1470 msgid "SUN4V-8002-US.type"
1471 msgstr "Fault"
1472 msgid "SUN4V-8002-US.severity"
1473 msgstr "Critical"
1474 msgid "SUN4V-8002-US.description"
1475 msgstr "The Service Processor failed.\n  Refer to %s for more information."
1476 msgid "SUN4V-8002-US.response"
1477 msgstr "No automated response.\n"
1478 msgid "SUN4V-8002-US.impact"