1 #
   2 # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #
  24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # code: SUN4V-8000-1S
  28 # keys: fault.cpu.ultraSPARC-T1.ireg
  29 #
  30 msgid "SUN4V-8000-1S.type"
  31 msgstr "Fault"
  32 msgid "SUN4V-8000-1S.severity"
  33 msgstr "Minor"
  34 msgid "SUN4V-8000-1S.description"
  35 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  36 msgid "SUN4V-8000-1S.response"
  37 msgstr "The fault manager will attempt to remove the affected CPU from service."
  38 msgid "SUN4V-8000-1S.impact"
  39 msgstr "System performance may be affected."
  40 msgid "SUN4V-8000-1S.action"
  41 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  42 #
  43 # code: SUN4V-8000-2A
  44 # keys: fault.cpu.ultraSPARC-T1.freg
  45 #
  46 msgid "SUN4V-8000-2A.type"
  47 msgstr "Fault"
  48 msgid "SUN4V-8000-2A.severity"
  49 msgstr "Major"
  50 msgid "SUN4V-8000-2A.description"
  51 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  52 msgid "SUN4V-8000-2A.response"
  53 msgstr "None"
  54 msgid "SUN4V-8000-2A.impact"
  55 msgstr "System performance may be affected."
  56 msgid "SUN4V-8000-2A.action"
  57 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  58 #
  59 # code: SUN4V-8000-3P
  60 # keys: fault.cpu.ultraSPARC-T1.itlb
  61 #
  62 msgid "SUN4V-8000-3P.type"
  63 msgstr "Fault"
  64 msgid "SUN4V-8000-3P.severity"
  65 msgstr "Minor"
  66 msgid "SUN4V-8000-3P.description"
  67 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  68 msgid "SUN4V-8000-3P.response"
  69 msgstr "The fault manager will attempt to remove the affected CPU from service."
  70 msgid "SUN4V-8000-3P.impact"
  71 msgstr "System performance may be affected.\n"
  72 msgid "SUN4V-8000-3P.action"
  73 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  74 #
  75 # code: SUN4V-8000-4D
  76 # keys: fault.cpu.ultraSPARC-T1.dtlb
  77 #
  78 msgid "SUN4V-8000-4D.type"
  79 msgstr "Fault"
  80 msgid "SUN4V-8000-4D.severity"
  81 msgstr "Minor"
  82 msgid "SUN4V-8000-4D.description"
  83 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
  84 msgid "SUN4V-8000-4D.response"
  85 msgstr "The fault manager will attempt to remove the affected CPU from service."
  86 msgid "SUN4V-8000-4D.impact"
  87 msgstr "System performance may be affected.\n"
  88 msgid "SUN4V-8000-4D.action"
  89 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
  90 #
  91 # code: SUN4V-8000-5H
  92 # keys: fault.cpu.ultraSPARC-T1.icache
  93 #
  94 msgid "SUN4V-8000-5H.type"
  95 msgstr "Fault"
  96 msgid "SUN4V-8000-5H.severity"
  97 msgstr "Minor"
  98 msgid "SUN4V-8000-5H.description"
  99 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 100 msgid "SUN4V-8000-5H.response"
 101 msgstr "The fault manager will attempt to remove the affected CPU from service."
 102 msgid "SUN4V-8000-5H.impact"
 103 msgstr "System performance may be affected.\n"
 104 msgid "SUN4V-8000-5H.action"
 105 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 106 #
 107 # code: SUN4V-8000-63
 108 # keys: fault.cpu.ultraSPARC-T1.dcache
 109 #
 110 msgid "SUN4V-8000-63.type"
 111 msgstr "Fault"
 112 msgid "SUN4V-8000-63.severity"
 113 msgstr "Minor"
 114 msgid "SUN4V-8000-63.description"
 115 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 116 msgid "SUN4V-8000-63.response"
 117 msgstr "The fault manager will attempt to remove the affected CPU from service."
 118 msgid "SUN4V-8000-63.impact"
 119 msgstr "System performance may be affected.\n"
 120 msgid "SUN4V-8000-63.action"
 121 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 122 #
 123 # code: SUN4V-8000-7Y
 124 # keys: fault.cpu.ultraSPARC-T1.mau
 125 #
 126 msgid "SUN4V-8000-7Y.type"
 127 msgstr "Fault"
 128 msgid "SUN4V-8000-7Y.severity"
 129 msgstr "Major"
 130 msgid "SUN4V-8000-7Y.description"
 131 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 132 msgid "SUN4V-8000-7Y.response"
 133 msgstr "None"
 134 msgid "SUN4V-8000-7Y.impact"
 135 msgstr "System performance may be affected.\n"
 136 msgid "SUN4V-8000-7Y.action"
 137 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 138 #
 139 # code: SUN4V-8000-8Q
 140 # keys: fault.cpu.ultraSPARC-T1.l2cachedata
 141 #
 142 msgid "SUN4V-8000-8Q.type"
 143 msgstr "Fault"
 144 msgid "SUN4V-8000-8Q.severity"
 145 msgstr "Critical"
 146 msgid "SUN4V-8000-8Q.description"
 147 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 148 msgid "SUN4V-8000-8Q.response"
 149 msgstr "None"
 150 msgid "SUN4V-8000-8Q.impact"
 151 msgstr "System performance may be affected.\n"
 152 msgid "SUN4V-8000-8Q.action"
 153 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 154 #
 155 # code: SUN4V-8000-9C
 156 # keys: fault.cpu.ultraSPARC-T1.l2cachetag
 157 #
 158 msgid "SUN4V-8000-9C.type"
 159 msgstr "Fault"
 160 msgid "SUN4V-8000-9C.severity"
 161 msgstr "Critical"
 162 msgid "SUN4V-8000-9C.description"
 163 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 164 msgid "SUN4V-8000-9C.response"
 165 msgstr "None"
 166 msgid "SUN4V-8000-9C.impact"
 167 msgstr "System performance may be affected.\n"
 168 msgid "SUN4V-8000-9C.action"
 169 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 170 #
 171 # code: SUN4V-8000-AR
 172 # keys: fault.cpu.ultraSPARC-T1.l2cachectl
 173 #
 174 msgid "SUN4V-8000-AR.type"
 175 msgstr "Fault"
 176 msgid "SUN4V-8000-AR.severity"
 177 msgstr "Critical"
 178 msgid "SUN4V-8000-AR.description"
 179 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
 180 msgid "SUN4V-8000-AR.response"
 181 msgstr "None"
 182 msgid "SUN4V-8000-AR.impact"
 183 msgstr "System performance may be affected.\n"
 184 msgid "SUN4V-8000-AR.action"
 185 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
 186 #
 187 # code: SUN4V-8000-C4
 188 # keys: fault.memory.page
 189 #
 190 msgid "SUN4V-8000-C4.type"
 191 msgstr "Fault"
 192 msgid "SUN4V-8000-C4.severity"
 193 msgstr "Minor"
 194 msgid "SUN4V-8000-C4.description"
 195 msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
 196 msgid "SUN4V-8000-C4.response"
 197 msgstr "An attempt will be made to remove this memory page from service."
 198 msgid "SUN4V-8000-C4.impact"
 199 msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
 200 msgid "SUN4V-8000-C4.action"
 201 msgstr "No repair action is recommended at this time."
 202 #
 203 # code: SUN4V-8000-DX
 204 # keys: fault.memory.dimm
 205 #
 206 msgid "SUN4V-8000-DX.type"
 207 msgstr "Fault"
 208 msgid "SUN4V-8000-DX.severity"
 209 msgstr "Major"
 210 msgid "SUN4V-8000-DX.description"
 211 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
 212 msgid "SUN4V-8000-DX.response"
 213 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
 214 msgid "SUN4V-8000-DX.impact"
 215 msgstr "Total system memory capacity has been reduced."
 216 msgid "SUN4V-8000-DX.action"
 217 msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
 218 #
 219 # code: SUN4V-8000-E2
 220 # keys: fault.memory.bank
 221 #
 222 msgid "SUN4V-8000-E2.type"
 223 msgstr "Fault"
 224 msgid "SUN4V-8000-E2.severity"
 225 msgstr "Critical"
 226 msgid "SUN4V-8000-E2.description"
 227 msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
 228 msgid "SUN4V-8000-E2.response"
 229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
 230 msgid "SUN4V-8000-E2.impact"
 231 msgstr "Total system memory capacity will be reduced as pages are retired."
 232 msgid "SUN4V-8000-E2.action"
 233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
 234 #
 235 # code: SUN4V-8000-FJ
 236 # keys: fault.memory.link-c
 237 #
 238 msgid "SUN4V-8000-FJ.type"
 239 msgstr "Fault"
 240 msgid "SUN4V-8000-FJ.severity"
 241 msgstr "Major"
 242 msgid "SUN4V-8000-FJ.description"
 243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 244 msgid "SUN4V-8000-FJ.response"
 245 msgstr "No automated response.\n"
 246 msgid "SUN4V-8000-FJ.impact"
 247 msgstr "System performance may be impacted.\n"
 248 msgid "SUN4V-8000-FJ.action"
 249 msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 250 #
 251 # code: SUN4V-8000-GE
 252 # keys: fault.cpu.ultraSPARC-T2.ireg
 253 #
 254 msgid "SUN4V-8000-GE.type"
 255 msgstr "Fault"
 256 msgid "SUN4V-8000-GE.severity"
 257 msgstr "Minor"
 258 msgid "SUN4V-8000-GE.description"
 259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 260 msgid "SUN4V-8000-GE.response"
 261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 262 msgid "SUN4V-8000-GE.impact"
 263 msgstr "System performance may be affected. \n"
 264 msgid "SUN4V-8000-GE.action"
 265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 266 #
 267 # code: SUN4V-8000-HP
 268 # keys: fault.cpu.ultraSPARC-T2.freg
 269 #
 270 msgid "SUN4V-8000-HP.type"
 271 msgstr "Fault"
 272 msgid "SUN4V-8000-HP.severity"
 273 msgstr "Minor"
 274 msgid "SUN4V-8000-HP.description"
 275 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 276 msgid "SUN4V-8000-HP.response"
 277 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 278 msgid "SUN4V-8000-HP.impact"
 279 msgstr "System performance may be affected. \n"
 280 msgid "SUN4V-8000-HP.action"
 281 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 282 #
 283 # code: SUN4V-8000-JA
 284 # keys: fault.cpu.ultraSPARC-T2.misc_reg
 285 #
 286 msgid "SUN4V-8000-JA.type"
 287 msgstr "Fault"
 288 msgid "SUN4V-8000-JA.severity"
 289 msgstr "Minor"
 290 msgid "SUN4V-8000-JA.description"
 291 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 292 msgid "SUN4V-8000-JA.response"
 293 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 294 msgid "SUN4V-8000-JA.impact"
 295 msgstr "System performance may be affected. \n"
 296 msgid "SUN4V-8000-JA.action"
 297 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 298 #
 299 # code: SUN4V-8000-KS
 300 # keys: fault.cpu.ultraSPARC-T2.itlb
 301 #
 302 msgid "SUN4V-8000-KS.type"
 303 msgstr "Fault"
 304 msgid "SUN4V-8000-KS.severity"
 305 msgstr "Major"
 306 msgid "SUN4V-8000-KS.description"
 307 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 308 msgid "SUN4V-8000-KS.response"
 309 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 310 msgid "SUN4V-8000-KS.impact"
 311 msgstr "System performance is likely to be affected. \n"
 312 msgid "SUN4V-8000-KS.action"
 313 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 314 #
 315 # code: SUN4V-8000-L5
 316 # keys: fault.cpu.ultraSPARC-T2.dtlb
 317 #
 318 msgid "SUN4V-8000-L5.type"
 319 msgstr "Fault"
 320 msgid "SUN4V-8000-L5.severity"
 321 msgstr "Major"
 322 msgid "SUN4V-8000-L5.description"
 323 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 324 msgid "SUN4V-8000-L5.response"
 325 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 326 msgid "SUN4V-8000-L5.impact"
 327 msgstr "System performance is likely to be affected. \n"
 328 msgid "SUN4V-8000-L5.action"
 329 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 330 #
 331 # code: SUN4V-8000-MY
 332 # keys: fault.cpu.ultraSPARC-T2.icache
 333 #
 334 msgid "SUN4V-8000-MY.type"
 335 msgstr "Fault"
 336 msgid "SUN4V-8000-MY.severity"
 337 msgstr "Major"
 338 msgid "SUN4V-8000-MY.description"
 339 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 340 msgid "SUN4V-8000-MY.response"
 341 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 342 msgid "SUN4V-8000-MY.impact"
 343 msgstr "System performance is likely to be affected. \n"
 344 msgid "SUN4V-8000-MY.action"
 345 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 346 #
 347 # code: SUN4V-8000-N3
 348 # keys: fault.cpu.ultraSPARC-T2.dcache
 349 #
 350 msgid "SUN4V-8000-N3.type"
 351 msgstr "Fault"
 352 msgid "SUN4V-8000-N3.severity"
 353 msgstr "Major"
 354 msgid "SUN4V-8000-N3.description"
 355 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 356 msgid "SUN4V-8000-N3.response"
 357 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 358 msgid "SUN4V-8000-N3.impact"
 359 msgstr "System performance is likely to be affected. \n"
 360 msgid "SUN4V-8000-N3.action"
 361 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 362 #
 363 # code: SUN4V-8000-PH
 364 # keys: fault.cpu.ultraSPARC-T2.mau
 365 #
 366 msgid "SUN4V-8000-PH.type"
 367 msgstr "Fault"
 368 msgid "SUN4V-8000-PH.severity"
 369 msgstr "Major"
 370 msgid "SUN4V-8000-PH.description"
 371 msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n  Refer to %s for more information."
 372 msgid "SUN4V-8000-PH.response"
 373 msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
 374 msgid "SUN4V-8000-PH.impact"
 375 msgstr "System performance is likely to be affected. \n"
 376 msgid "SUN4V-8000-PH.action"
 377 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 378 #
 379 # code: SUN4V-8000-QD
 380 # keys: fault.cpu.ultraSPARC-T2.l2data-c
 381 #
 382 msgid "SUN4V-8000-QD.type"
 383 msgstr "Fault"
 384 msgid "SUN4V-8000-QD.severity"
 385 msgstr "Critical"
 386 msgid "SUN4V-8000-QD.description"
 387 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 388 msgid "SUN4V-8000-QD.response"
 389 msgstr "No automated response.\n"
 390 msgid "SUN4V-8000-QD.impact"
 391 msgstr "System performance is likely to be affected. \n"
 392 msgid "SUN4V-8000-QD.action"
 393 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 394 #
 395 # code: SUN4V-8000-R4
 396 # keys: fault.cpu.ultraSPARC-T2.l2cachetag
 397 #
 398 msgid "SUN4V-8000-R4.type"
 399 msgstr "Fault"
 400 msgid "SUN4V-8000-R4.severity"
 401 msgstr "Critical"
 402 msgid "SUN4V-8000-R4.description"
 403 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
 404 msgid "SUN4V-8000-R4.response"
 405 msgstr "No automated response.\n"
 406 msgid "SUN4V-8000-R4.impact"
 407 msgstr "System performance is likely to be affected. \n"
 408 msgid "SUN4V-8000-R4.action"
 409 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 410 #
 411 # code: SUN4V-8000-SR
 412 # keys: fault.cpu.ultraSPARC-T2.l2cachectl
 413 #
 414 msgid "SUN4V-8000-SR.type"
 415 msgstr "Fault"
 416 msgid "SUN4V-8000-SR.severity"
 417 msgstr "Critical"
 418 msgid "SUN4V-8000-SR.description"
 419 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
 420 msgid "SUN4V-8000-SR.response"
 421 msgstr "No automated response.\n"
 422 msgid "SUN4V-8000-SR.impact"
 423 msgstr "System performance is likely to be affected. System may be unstable.\n"
 424 msgid "SUN4V-8000-SR.action"
 425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 426 #
 427 # code: SUN4V-8000-TC
 428 # keys: fault.memory.link-u
 429 #
 430 msgid "SUN4V-8000-TC.type"
 431 msgstr "Fault"
 432 msgid "SUN4V-8000-TC.severity"
 433 msgstr "Critical"
 434 msgid "SUN4V-8000-TC.description"
 435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
 436 msgid "SUN4V-8000-TC.response"
 437 msgstr "No automated response.\n"
 438 msgid "SUN4V-8000-TC.impact"
 439 msgstr "System performance may be impacted.\n"
 440 msgid "SUN4V-8000-TC.action"
 441 msgstr "At a convenient time, try reseating the memory module.  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 442 #
 443 # code: SUN4V-8000-UQ
 444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
 445 #
 446 msgid "SUN4V-8000-UQ.type"
 447 msgstr "Fault"
 448 msgid "SUN4V-8000-UQ.severity"
 449 msgstr "Critical"
 450 msgid "SUN4V-8000-UQ.description"
 451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 452 msgid "SUN4V-8000-UQ.response"
 453 msgstr "No automated response.\n"
 454 msgid "SUN4V-8000-UQ.impact"
 455 msgstr "System performance is likely to be affected. \n"
 456 msgid "SUN4V-8000-UQ.action"
 457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 458 #
 459 # code: SUN4V-8000-VE
 460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
 461 #
 462 msgid "SUN4V-8000-VE.type"
 463 msgstr "Fault"
 464 msgid "SUN4V-8000-VE.severity"
 465 msgstr "Critical"
 466 msgid "SUN4V-8000-VE.description"
 467 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 468 msgid "SUN4V-8000-VE.response"
 469 msgstr "No automated response.\n"
 470 msgid "SUN4V-8000-VE.impact"
 471 msgstr "System performance is likely to be affected. \n"
 472 msgid "SUN4V-8000-VE.action"
 473 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 474 #
 475 # code: SUN4V-8000-WJ
 476 # keys: fault.cpu.ultraSPARC-T1.l2data-u
 477 #
 478 msgid "SUN4V-8000-WJ.type"
 479 msgstr "Fault"
 480 msgid "SUN4V-8000-WJ.severity"
 481 msgstr "Critical"
 482 msgid "SUN4V-8000-WJ.description"
 483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 484 msgid "SUN4V-8000-WJ.response"
 485 msgstr "No automated response.\n"
 486 msgid "SUN4V-8000-WJ.impact"
 487 msgstr "System performance is likely to be affected. \n"
 488 msgid "SUN4V-8000-WJ.action"
 489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 490 #
 491 # code: SUN4V-8000-X2
 492 # keys: fault.memory.datapath
 493 #
 494 msgid "SUN4V-8000-X2.type"
 495 msgstr "Fault"
 496 msgid "SUN4V-8000-X2.severity"
 497 msgstr "Major"
 498 msgid "SUN4V-8000-X2.description"
 499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
 500 msgid "SUN4V-8000-X2.response"
 501 msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n"
 502 msgid "SUN4V-8000-X2.impact"
 503 msgstr "System performance and stability may be affected. \n"
 504 msgid "SUN4V-8000-X2.action"
 505 msgstr "Contact your service provider for further diagnosis.\n"
 506 #
 507 # code: SUN4V-8000-YX
 508 # keys: fault.io.n2.ncu
 509 #
 510 msgid "SUN4V-8000-YX.type"
 511 msgstr "Fault"
 512 msgid "SUN4V-8000-YX.severity"
 513 msgstr "Critical"
 514 msgid "SUN4V-8000-YX.description"
 515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
 516 msgid "SUN4V-8000-YX.response"
 517 msgstr "One or more device instances may be disabled\n"
 518 msgid "SUN4V-8000-YX.impact"
 519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 520 msgid "SUN4V-8000-YX.action"
 521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n"
 522 #
 523 # code: SUN4V-8001-02
 524 # keys: fault.io.n2.dmu
 525 #
 526 msgid "SUN4V-8001-02.type"
 527 msgstr "Fault"
 528 msgid "SUN4V-8001-02.severity"
 529 msgstr "Critical"
 530 msgid "SUN4V-8001-02.description"
 531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
 532 msgid "SUN4V-8001-02.response"
 533 msgstr "One or more device instances may be disabled\n"
 534 msgid "SUN4V-8001-02.impact"
 535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 536 msgid "SUN4V-8001-02.action"
 537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 538 #
 539 # code: SUN4V-8001-1X
 540 # keys: fault.io.n2.niu
 541 #
 542 msgid "SUN4V-8001-1X.type"
 543 msgstr "Fault"
 544 msgid "SUN4V-8001-1X.severity"
 545 msgstr "Critical"
 546 msgid "SUN4V-8001-1X.description"
 547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
 548 msgid "SUN4V-8001-1X.response"
 549 msgstr "One or more device instances may be disabled\n"
 550 msgid "SUN4V-8001-1X.impact"
 551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 552 msgid "SUN4V-8001-1X.action"
 553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 554 #
 555 # code: SUN4V-8001-2E
 556 # keys: fault.io.n2.siu
 557 #
 558 msgid "SUN4V-8001-2E.type"
 559 msgstr "Fault"
 560 msgid "SUN4V-8001-2E.severity"
 561 msgstr "Critical"
 562 msgid "SUN4V-8001-2E.description"
 563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
 564 msgid "SUN4V-8001-2E.response"
 565 msgstr "One or more device instances may be disabled\n"
 566 msgid "SUN4V-8001-2E.impact"
 567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 568 msgid "SUN4V-8001-2E.action"
 569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 570 #
 571 # code: SUN4V-8001-3J
 572 # keys: fault.io.n2.soc
 573 #
 574 msgid "SUN4V-8001-3J.type"
 575 msgstr "Fault"
 576 msgid "SUN4V-8001-3J.severity"
 577 msgstr "Critical"
 578 msgid "SUN4V-8001-3J.description"
 579 msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
 580 msgid "SUN4V-8001-3J.response"
 581 msgstr "One or more device instances may be disabled\n"
 582 msgid "SUN4V-8001-3J.impact"
 583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 584 msgid "SUN4V-8001-3J.action"
 585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 586 #
 587 # code: SUN4V-8001-4C
 588 # keys: fault.io.n2.crossbar
 589 #
 590 msgid "SUN4V-8001-4C.type"
 591 msgstr "Fault"
 592 msgid "SUN4V-8001-4C.severity"
 593 msgstr "Critical"
 594 msgid "SUN4V-8001-4C.description"
 595 msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
 596 msgid "SUN4V-8001-4C.response"
 597 msgstr "One or more device instances may be disabled\n"
 598 msgid "SUN4V-8001-4C.impact"
 599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 600 msgid "SUN4V-8001-4C.action"
 601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 602 #
 603 # code: SUN4V-8001-5Q
 604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
 605 #
 606 msgid "SUN4V-8001-5Q.type"
 607 msgstr "Fault"
 608 msgid "SUN4V-8001-5Q.severity"
 609 msgstr "Critical"
 610 msgid "SUN4V-8001-5Q.description"
 611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
 612 msgid "SUN4V-8001-5Q.response"
 613 msgstr "One or more device instances may be disabled\n"
 614 msgid "SUN4V-8001-5Q.impact"
 615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 616 msgid "SUN4V-8001-5Q.action"
 617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 618 #
 619 # code: SUN4V-8001-64
 620 # keys: fault.io.vf.ncx
 621 #
 622 msgid "SUN4V-8001-64.type"
 623 msgstr "Fault"
 624 msgid "SUN4V-8001-64.severity"
 625 msgstr "Critical"
 626 msgid "SUN4V-8001-64.description"
 627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
 628 msgid "SUN4V-8001-64.response"
 629 msgstr "One or more device instances may be disabled\n"
 630 msgid "SUN4V-8001-64.impact"
 631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 632 msgid "SUN4V-8001-64.action"
 633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 634 #
 635 # code: SUN4V-8001-7R
 636 # keys: fault.memory.link-f
 637 #
 638 msgid "SUN4V-8001-7R.type"
 639 msgstr "Fault"
 640 msgid "SUN4V-8001-7R.severity"
 641 msgstr "Major"
 642 msgid "SUN4V-8001-7R.description"
 643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
 644 msgid "SUN4V-8001-7R.response"
 645 msgstr "No automated response.\n"
 646 msgid "SUN4V-8001-7R.impact"
 647 msgstr "System performance may be impacted.\n"
 648 msgid "SUN4V-8001-7R.action"
 649 msgstr "At a convenient time, try reseating the memory module(s).  If the problem persists,\ncontact your hardware support team to schedule part replacement.\n"
 650 #
 651 # code: SUN4V-8001-8H
 652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
 653 #
 654 msgid "SUN4V-8001-8H.type"
 655 msgstr "Fault"
 656 msgid "SUN4V-8001-8H.severity"
 657 msgstr "Minor"
 658 msgid "SUN4V-8001-8H.description"
 659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 660 msgid "SUN4V-8001-8H.response"
 661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 662 msgid "SUN4V-8001-8H.impact"
 663 msgstr "System performance may be affected. \n"
 664 msgid "SUN4V-8001-8H.action"
 665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 666 #
 667 # code: SUN4V-8001-9D
 668 # keys: fault.cpu.ultraSPARC-T2plus.freg
 669 #
 670 msgid "SUN4V-8001-9D.type"
 671 msgstr "Fault"
 672 msgid "SUN4V-8001-9D.severity"
 673 msgstr "Minor"
 674 msgid "SUN4V-8001-9D.description"
 675 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 676 msgid "SUN4V-8001-9D.response"
 677 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 678 msgid "SUN4V-8001-9D.impact"
 679 msgstr "System performance may be affected. \n"
 680 msgid "SUN4V-8001-9D.action"
 681 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 682 #
 683 # code: SUN4V-8001-AY
 684 # keys: fault.cpu.ultraSPARC-T2plus.misc_reg
 685 #
 686 msgid "SUN4V-8001-AY.type"
 687 msgstr "Fault"
 688 msgid "SUN4V-8001-AY.severity"
 689 msgstr "Minor"
 690 msgid "SUN4V-8001-AY.description"
 691 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 692 msgid "SUN4V-8001-AY.response"
 693 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
 694 msgid "SUN4V-8001-AY.impact"
 695 msgstr "System performance may be affected. \n"
 696 msgid "SUN4V-8001-AY.action"
 697 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 698 #
 699 # code: SUN4V-8001-C3
 700 # keys: fault.cpu.ultraSPARC-T2plus.itlb
 701 #
 702 msgid "SUN4V-8001-C3.type"
 703 msgstr "Fault"
 704 msgid "SUN4V-8001-C3.severity"
 705 msgstr "Major"
 706 msgid "SUN4V-8001-C3.description"
 707 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 708 msgid "SUN4V-8001-C3.response"
 709 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 710 msgid "SUN4V-8001-C3.impact"
 711 msgstr "System performance is likely to be affected. \n"
 712 msgid "SUN4V-8001-C3.action"
 713 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 714 #
 715 # code: SUN4V-8001-DS
 716 # keys: fault.cpu.ultraSPARC-T2plus.dtlb
 717 #
 718 msgid "SUN4V-8001-DS.type"
 719 msgstr "Fault"
 720 msgid "SUN4V-8001-DS.severity"
 721 msgstr "Major"
 722 msgid "SUN4V-8001-DS.description"
 723 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 724 msgid "SUN4V-8001-DS.response"
 725 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 726 msgid "SUN4V-8001-DS.impact"
 727 msgstr "System performance is likely to be affected. \n"
 728 msgid "SUN4V-8001-DS.action"
 729 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 730 #
 731 # code: SUN4V-8001-E5
 732 # keys: fault.cpu.ultraSPARC-T2plus.icache
 733 #
 734 msgid "SUN4V-8001-E5.type"
 735 msgstr "Fault"
 736 msgid "SUN4V-8001-E5.severity"
 737 msgstr "Major"
 738 msgid "SUN4V-8001-E5.description"
 739 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 740 msgid "SUN4V-8001-E5.response"
 741 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 742 msgid "SUN4V-8001-E5.impact"
 743 msgstr "System performance is likely to be affected. \n"
 744 msgid "SUN4V-8001-E5.action"
 745 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 746 #
 747 # code: SUN4V-8001-FP
 748 # keys: fault.cpu.ultraSPARC-T2plus.dcache
 749 #
 750 msgid "SUN4V-8001-FP.type"
 751 msgstr "Fault"
 752 msgid "SUN4V-8001-FP.severity"
 753 msgstr "Major"
 754 msgid "SUN4V-8001-FP.description"
 755 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 756 msgid "SUN4V-8001-FP.response"
 757 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
 758 msgid "SUN4V-8001-FP.impact"
 759 msgstr "System performance is likely to be affected. \n"
 760 msgid "SUN4V-8001-FP.action"
 761 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 762 #
 763 # code: SUN4V-8001-GA
 764 # keys: fault.cpu.ultraSPARC-T2plus.mau
 765 #
 766 msgid "SUN4V-8001-GA.type"
 767 msgstr "Fault"
 768 msgid "SUN4V-8001-GA.severity"
 769 msgstr "Major"
 770 msgid "SUN4V-8001-GA.description"
 771 msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
 772 msgid "SUN4V-8001-GA.response"
 773 msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
 774 msgid "SUN4V-8001-GA.impact"
 775 msgstr "System performance is likely to be affected. \n"
 776 msgid "SUN4V-8001-GA.action"
 777 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 778 #
 779 # code: SUN4V-8001-HJ
 780 # keys: fault.cpu.ultraSPARC-T2plus.l2data-c
 781 #
 782 msgid "SUN4V-8001-HJ.type"
 783 msgstr "Fault"
 784 msgid "SUN4V-8001-HJ.severity"
 785 msgstr "Critical"
 786 msgid "SUN4V-8001-HJ.description"
 787 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 788 msgid "SUN4V-8001-HJ.response"
 789 msgstr "No automated response.\n"
 790 msgid "SUN4V-8001-HJ.impact"
 791 msgstr "System performance is likely to be affected. \n"
 792 msgid "SUN4V-8001-HJ.action"
 793 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 794 #
 795 # code: SUN4V-8001-JE
 796 # keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
 797 #
 798 msgid "SUN4V-8001-JE.type"
 799 msgstr "Fault"
 800 msgid "SUN4V-8001-JE.severity"
 801 msgstr "Critical"
 802 msgid "SUN4V-8001-JE.description"
 803 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
 804 msgid "SUN4V-8001-JE.response"
 805 msgstr "No automated response.\n"
 806 msgid "SUN4V-8001-JE.impact"
 807 msgstr "System performance is likely to be affected. \n"
 808 msgid "SUN4V-8001-JE.action"
 809 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 810 #
 811 # code: SUN4V-8001-KX
 812 # keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
 813 #
 814 msgid "SUN4V-8001-KX.type"
 815 msgstr "Fault"
 816 msgid "SUN4V-8001-KX.severity"
 817 msgstr "Critical"
 818 msgid "SUN4V-8001-KX.description"
 819 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
 820 msgid "SUN4V-8001-KX.response"
 821 msgstr "No automated response.\n"
 822 msgid "SUN4V-8001-KX.impact"
 823 msgstr "System performance is likely to be affected. System may be unstable.\n"
 824 msgid "SUN4V-8001-KX.action"
 825 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 826 #
 827 # code: SUN4V-8001-L2
 828 # keys: fault.cpu.ultraSPARC-T2plus.l2data-u
 829 #
 830 msgid "SUN4V-8001-L2.type"
 831 msgstr "Fault"
 832 msgid "SUN4V-8001-L2.severity"
 833 msgstr "Critical"
 834 msgid "SUN4V-8001-L2.description"
 835 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
 836 msgid "SUN4V-8001-L2.response"
 837 msgstr "No automated response.\n"
 838 msgid "SUN4V-8001-L2.impact"
 839 msgstr "System performance is likely to be affected. \n"
 840 msgid "SUN4V-8001-L2.action"
 841 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 842 #
 843 # code: SUN4V-8001-MR
 844 # keys: fault.cpu.ultraSPARC-T2plus.lfu-f
 845 #
 846 msgid "SUN4V-8001-MR.type"
 847 msgstr "Fault"
 848 msgid "SUN4V-8001-MR.severity"
 849 msgstr "Major"
 850 msgid "SUN4V-8001-MR.description"
 851 msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n  Refer to %s for more information."
 852 msgid "SUN4V-8001-MR.response"
 853 msgstr "No other automated response.\n"
 854 msgid "SUN4V-8001-MR.impact"
 855 msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
 856 msgid "SUN4V-8001-MR.action"
 857 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 858 #
 859 # code: SUN4V-8001-N4
 860 # keys: fault.cpu.ultraSPARC-T2plus.lfu-p
 861 #
 862 msgid "SUN4V-8001-N4.type"
 863 msgstr "Fault"
 864 msgid "SUN4V-8001-N4.severity"
 865 msgstr "Major"
 866 msgid "SUN4V-8001-N4.description"
 867 msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n  Refer to %s for more information."
 868 msgid "SUN4V-8001-N4.response"
 869 msgstr "No automated response.\n"
 870 msgid "SUN4V-8001-N4.impact"
 871 msgstr "The system has most likely taken a fatal reset.\n"
 872 msgid "SUN4V-8001-N4.action"
 873 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 874 #
 875 # code: SUN4V-8001-PQ
 876 # keys: fault.cpu.ultraSPARC-T2plus.lfu-u
 877 #
 878 msgid "SUN4V-8001-PQ.type"
 879 msgstr "Fault"
 880 msgid "SUN4V-8001-PQ.severity"
 881 msgstr "Major"
 882 msgid "SUN4V-8001-PQ.description"
 883 msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n  Refer to %s for more information."
 884 msgid "SUN4V-8001-PQ.response"
 885 msgstr "No automated response.\n"
 886 msgid "SUN4V-8001-PQ.impact"
 887 msgstr "The system's integrity is seriously compromised.\n"
 888 msgid "SUN4V-8001-PQ.action"
 889 msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
 890 #
 891 # code: SUN4V-8001-QC
 892 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
 893 #
 894 msgid "SUN4V-8001-QC.type"
 895 msgstr "Fault"
 896 msgid "SUN4V-8001-QC.severity"
 897 msgstr "Critical"
 898 msgid "SUN4V-8001-QC.description"
 899 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n  Refer to %s for more information."
 900 msgid "SUN4V-8001-QC.response"
 901 msgstr "No automated reponse.\n"
 902 msgid "SUN4V-8001-QC.impact"
 903 msgstr "The system's integrity is compromised.\n"
 904 msgid "SUN4V-8001-QC.action"
 905 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 906 #
 907 # code: SUN4V-8001-R3
 908 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
 909 #
 910 msgid "SUN4V-8001-R3.type"
 911 msgstr "Fault"
 912 msgid "SUN4V-8001-R3.severity"
 913 msgstr "Major"
 914 msgid "SUN4V-8001-R3.description"
 915 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n  Refer to %s for more information."
 916 msgid "SUN4V-8001-R3.response"
 917 msgstr "No automated reponse.\n"
 918 msgid "SUN4V-8001-R3.impact"
 919 msgstr "The system's integrity is compromised.\n"
 920 msgid "SUN4V-8001-R3.action"
 921 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 922 #
 923 # code: SUN4V-8001-SY
 924 # keys: fault.cpu.ultraSPARC-T2plus.chip
 925 #
 926 msgid "SUN4V-8001-SY.type"
 927 msgstr "Fault"
 928 msgid "SUN4V-8001-SY.severity"
 929 msgstr "Critical"
 930 msgid "SUN4V-8001-SY.description"
 931 msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n  Refer to %s for more information."
 932 msgid "SUN4V-8001-SY.response"
 933 msgstr "No automated reponse.\n"
 934 msgid "SUN4V-8001-SY.impact"
 935 msgstr "The system's integrity is seriously compromised.\n"
 936 msgid "SUN4V-8001-SY.action"
 937 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 938 #
 939 # code: SUN4V-8001-TD
 940 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
 941 #
 942 msgid "SUN4V-8001-TD.type"
 943 msgstr "Fault"
 944 msgid "SUN4V-8001-TD.severity"
 945 msgstr "Minor"
 946 msgid "SUN4V-8001-TD.description"
 947 msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n  Refer to %s for more information."
 948 msgid "SUN4V-8001-TD.response"
 949 msgstr "No automated reponse.\n"
 950 msgid "SUN4V-8001-TD.impact"
 951 msgstr "The system's integrity is seriously compromised.\n"
 952 msgid "SUN4V-8001-TD.action"
 953 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 954 #
 955 # code: SUN4V-8001-UH
 956 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
 957 #
 958 msgid "SUN4V-8001-UH.type"
 959 msgstr "Fault"
 960 msgid "SUN4V-8001-UH.severity"
 961 msgstr "Major"
 962 msgid "SUN4V-8001-UH.description"
 963 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n  Refer to %s for more information."
 964 msgid "SUN4V-8001-UH.response"
 965 msgstr "No automated reponse.\n"
 966 msgid "SUN4V-8001-UH.impact"
 967 msgstr "The system's performance may be impacted.\n"
 968 msgid "SUN4V-8001-UH.action"
 969 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 970 #
 971 # code: SUN4V-8001-VA
 972 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
 973 #
 974 msgid "SUN4V-8001-VA.type"
 975 msgstr "Fault"
 976 msgid "SUN4V-8001-VA.severity"
 977 msgstr "Critical"
 978 msgid "SUN4V-8001-VA.description"
 979 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n  Refer to %s for more information."
 980 msgid "SUN4V-8001-VA.response"
 981 msgstr "No automated reponse.\n"
 982 msgid "SUN4V-8001-VA.impact"
 983 msgstr "The system's integrity is seriously compromised.\n"
 984 msgid "SUN4V-8001-VA.action"
 985 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
 986 #
 987 # code: SUN4V-8001-WP
 988 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
 989 #
 990 msgid "SUN4V-8001-WP.type"
 991 msgstr "Fault"
 992 msgid "SUN4V-8001-WP.severity"
 993 msgstr "Critical"
 994 msgid "SUN4V-8001-WP.description"
 995 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n  Refer to %s for more information."
 996 msgid "SUN4V-8001-WP.response"
 997 msgstr "No automated reponse.\n"
 998 msgid "SUN4V-8001-WP.impact"
 999 msgstr "The system's integrity is seriously compromised.\n"
1000 msgid "SUN4V-8001-WP.action"
1001 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1002 #
1003 # code: SUN4V-8001-X5
1004 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
1005 #
1006 msgid "SUN4V-8001-X5.type"
1007 msgstr "Fault"
1008 msgid "SUN4V-8001-X5.severity"
1009 msgstr "Critical"
1010 msgid "SUN4V-8001-X5.description"
1011 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n  Refer to %s for more information."
1012 msgid "SUN4V-8001-X5.response"
1013 msgstr "No automated reponse.\n"
1014 msgid "SUN4V-8001-X5.impact"
1015 msgstr "The system's performance may be compromised.\n"
1016 msgid "SUN4V-8001-X5.action"
1017 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1018 #
1019 # code: SUN4V-8001-YS
1020 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
1021 #
1022 msgid "SUN4V-8001-YS.type"
1023 msgstr "Fault"
1024 msgid "SUN4V-8001-YS.severity"
1025 msgstr "Major"
1026 msgid "SUN4V-8001-YS.description"
1027 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n  Refer to %s for more information."
1028 msgid "SUN4V-8001-YS.response"
1029 msgstr "No automated reponse.\n"
1030 msgid "SUN4V-8001-YS.impact"
1031 msgstr "The system's integrity may be seriously compromised.\n"
1032 msgid "SUN4V-8001-YS.action"
1033 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1034 #
1035 # code: SUN4V-8002-0C
1036 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1037 #
1038 msgid "SUN4V-8002-0C.type"
1039 msgstr "Fault"
1040 msgid "SUN4V-8002-0C.severity"
1041 msgstr "Major"
1042 msgid "SUN4V-8002-0C.description"
1043 msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n  Refer to %s for more information."
1044 msgid "SUN4V-8002-0C.response"
1045 msgstr "No automated reponse.\n"
1046 msgid "SUN4V-8002-0C.impact"
1047 msgstr "The system's performance may be impacted.\n"
1048 msgid "SUN4V-8002-0C.action"
1049 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1050 #
1051 # code: SUN4V-8002-1Q
1052 # keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1053 #
1054 msgid "SUN4V-8002-1Q.type"
1055 msgstr "Fault"
1056 msgid "SUN4V-8002-1Q.severity"
1057 msgstr "Major"
1058 msgid "SUN4V-8002-1Q.description"
1059 msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n  Refer to %s for more information."
1060 msgid "SUN4V-8002-1Q.response"
1061 msgstr "No automated reponse.\n"
1062 msgid "SUN4V-8002-1Q.impact"
1063 msgstr "The system's performance may be impacted.\n"
1064 msgid "SUN4V-8002-1Q.action"
1065 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1066 #
1067 # code: SUN4V-8002-24
1068 # keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
1069 #
1070 msgid "SUN4V-8002-24.type"
1071 msgstr "Fault"
1072 msgid "SUN4V-8002-24.severity"
1073 msgstr "Critical"
1074 msgid "SUN4V-8002-24.description"
1075 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n  Refer to %s for more information."
1076 msgid "SUN4V-8002-24.response"
1077 msgstr "No automated reponse.\n"
1078 msgid "SUN4V-8002-24.impact"
1079 msgstr "The system's integrity is seriously compromised.\n"
1080 msgid "SUN4V-8002-24.action"
1081 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1082 #
1083 # code: SUN4V-8002-3R
1084 # keys: fault.memory.dimm-page-retires-excessive
1085 #
1086 msgid "SUN4V-8002-3R.type"
1087 msgstr "Fault"
1088 msgid "SUN4V-8002-3R.severity"
1089 msgstr "Major"
1090 msgid "SUN4V-8002-3R.description"
1091 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n  Refer to %s for more information."
1092 msgid "SUN4V-8002-3R.response"
1093 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
1094 msgid "SUN4V-8002-3R.impact"
1095 msgstr "Total system memory capacity has been reduced.\n"
1096 msgid "SUN4V-8002-3R.action"
1097 msgstr "Schedule a repair procedure to replace the DIMM.  Use fmadm faulty to identify the DIMM to replace.\n"
1098 #
1099 # code: SUN4V-8002-42
1100 # keys: fault.memory.dimm-ue-imminent
1101 #
1102 msgid "SUN4V-8002-42.type"
1103 msgstr "Fault"
1104 msgid "SUN4V-8002-42.severity"
1105 msgstr "Critical"
1106 msgid "SUN4V-8002-42.description"
1107 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1108 msgid "SUN4V-8002-42.response"
1109 msgstr "None at this time.\n"
1110 msgid "SUN4V-8002-42.impact"
1111 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1112 msgid "SUN4V-8002-42.action"
1113 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1114 #
1115 # code: SUN4V-8002-5X
1116 # keys: fault.memory.dram-ue-imminent
1117 #
1118 msgid "SUN4V-8002-5X.type"
1119 msgstr "Fault"
1120 msgid "SUN4V-8002-5X.severity"
1121 msgstr "Critical"
1122 msgid "SUN4V-8002-5X.description"
1123 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1124 msgid "SUN4V-8002-5X.response"
1125 msgstr "None at this time.\n"
1126 msgid "SUN4V-8002-5X.impact"
1127 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1128 msgid "SUN4V-8002-5X.action"
1129 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1130 #
1131 # code: SUN4V-8002-6E
1132 # keys: fault.cpu.generic-sparc.strand
1133 #
1134 msgid "SUN4V-8002-6E.type"
1135 msgstr "Fault"
1136 msgid "SUN4V-8002-6E.severity"
1137 msgstr "Major"
1138 msgid "SUN4V-8002-6E.description"
1139 msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n  Refer to %s for more information."
1140 msgid "SUN4V-8002-6E.response"
1141 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1142 msgid "SUN4V-8002-6E.impact"
1143 msgstr "System performance may be affected. \n"
1144 msgid "SUN4V-8002-6E.action"
1145 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1146 #
1147 # code: SUN4V-8002-7J
1148 # keys: fault.cpu.generic-sparc.strand-nr
1149 #
1150 msgid "SUN4V-8002-7J.type"
1151 msgstr "Fault"
1152 msgid "SUN4V-8002-7J.severity"
1153 msgstr "Major"
1154 msgid "SUN4V-8002-7J.description"
1155 msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n  Refer to %s for more information."
1156 msgid "SUN4V-8002-7J.response"
1157 msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n"
1158 msgid "SUN4V-8002-7J.impact"
1159 msgstr "System performance may be affected. \n"
1160 msgid "SUN4V-8002-7J.action"
1161 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1162 #
1163 # code: SUN4V-8002-8S
1164 # keys: fault.cpu.generic-sparc.strand-uc
1165 #
1166 msgid "SUN4V-8002-8S.type"
1167 msgstr "Fault"
1168 msgid "SUN4V-8002-8S.severity"
1169 msgstr "Critical"
1170 msgid "SUN4V-8002-8S.description"
1171 msgstr "This strand has encountered an uncorrectable error.\n  Refer to %s for more information."
1172 msgid "SUN4V-8002-8S.response"
1173 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1174 msgid "SUN4V-8002-8S.impact"
1175 msgstr "System performance may be affected. \n"
1176 msgid "SUN4V-8002-8S.action"
1177 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1178 #
1179 # code: SUN4V-8002-95
1180 # keys: fault.cpu.generic-sparc.strand-uc-nr
1181 #
1182 msgid "SUN4V-8002-95.type"
1183 msgstr "Fault"
1184 msgid "SUN4V-8002-95.severity"
1185 msgstr "Critical"
1186 msgid "SUN4V-8002-95.description"
1187 msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n  Refer to %s for more information."
1188 msgid "SUN4V-8002-95.response"
1189 msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n"
1190 msgid "SUN4V-8002-95.impact"
1191 msgstr "System performance may be affected. \n"
1192 msgid "SUN4V-8002-95.action"
1193 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1194 #
1195 # code: SUN4V-8002-AP
1196 # keys: fault.cpu.generic-sparc.core
1197 #
1198 msgid "SUN4V-8002-AP.type"
1199 msgstr "Fault"
1200 msgid "SUN4V-8002-AP.severity"
1201 msgstr "Major"
1202 msgid "SUN4V-8002-AP.description"
1203 msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n  Refer to %s for more information."
1204 msgid "SUN4V-8002-AP.response"
1205 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1206 msgid "SUN4V-8002-AP.impact"
1207 msgstr "System performance may be affected. \n"
1208 msgid "SUN4V-8002-AP.action"
1209 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1210 #
1211 # code: SUN4V-8002-CA
1212 # keys: fault.cpu.generic-sparc.core-nr
1213 #
1214 msgid "SUN4V-8002-CA.type"
1215 msgstr "Fault"
1216 msgid "SUN4V-8002-CA.severity"
1217 msgstr "Major"
1218 msgid "SUN4V-8002-CA.description"
1219 msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n  Refer to %s for more information."
1220 msgid "SUN4V-8002-CA.response"
1221 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1222 msgid "SUN4V-8002-CA.impact"
1223 msgstr "System performance may be affected. \n"
1224 msgid "SUN4V-8002-CA.action"
1225 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1226 #
1227 # code: SUN4V-8002-DH
1228 # keys: fault.cpu.generic-sparc.core-uc
1229 #
1230 msgid "SUN4V-8002-DH.type"
1231 msgstr "Fault"
1232 msgid "SUN4V-8002-DH.severity"
1233 msgstr "Critical"
1234 msgid "SUN4V-8002-DH.description"
1235 msgstr "This core has encountered an uncorrectable error.\n  Refer to %s for more information."
1236 msgid "SUN4V-8002-DH.response"
1237 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1238 msgid "SUN4V-8002-DH.impact"
1239 msgstr "System performance may be affected. \n"
1240 msgid "SUN4V-8002-DH.action"
1241 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1242 #
1243 # code: SUN4V-8002-ED
1244 # keys: fault.cpu.generic-sparc.core-uc-nr
1245 #
1246 msgid "SUN4V-8002-ED.type"
1247 msgstr "Fault"
1248 msgid "SUN4V-8002-ED.severity"
1249 msgstr "Critical"
1250 msgid "SUN4V-8002-ED.description"
1251 msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n  Refer to %s for more information."
1252 msgid "SUN4V-8002-ED.response"
1253 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1254 msgid "SUN4V-8002-ED.impact"
1255 msgstr "System performance may be affected. \n"
1256 msgid "SUN4V-8002-ED.action"
1257 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1258 #
1259 # code: SUN4V-8002-FY
1260 # keys: fault.cpu.generic-sparc.chip
1261 #
1262 msgid "SUN4V-8002-FY.type"
1263 msgstr "Fault"
1264 msgid "SUN4V-8002-FY.severity"
1265 msgstr "Critical"
1266 msgid "SUN4V-8002-FY.description"
1267 msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n  Refer to %s for more information."
1268 msgid "SUN4V-8002-FY.response"
1269 msgstr "No automated response.\n"
1270 msgid "SUN4V-8002-FY.impact"
1271 msgstr "System performance may be affected. \n"
1272 msgid "SUN4V-8002-FY.action"
1273 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1274 #
1275 # code: SUN4V-8002-G3
1276 # keys: fault.cpu.generic-sparc.chip-nr
1277 #
1278 msgid "SUN4V-8002-G3.type"
1279 msgstr "Fault"
1280 msgid "SUN4V-8002-G3.severity"
1281 msgstr "Critical"
1282 msgid "SUN4V-8002-G3.description"
1283 msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n  Refer to %s for more information."
1284 msgid "SUN4V-8002-G3.response"
1285 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1286 msgid "SUN4V-8002-G3.impact"
1287 msgstr "System performance may be affected. \n"
1288 msgid "SUN4V-8002-G3.action"
1289 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1290 #
1291 # code: SUN4V-8002-HR
1292 # keys: fault.cpu.generic-sparc.chip-uc
1293 #
1294 msgid "SUN4V-8002-HR.type"
1295 msgstr "Fault"
1296 msgid "SUN4V-8002-HR.severity"
1297 msgstr "Critical"
1298 msgid "SUN4V-8002-HR.description"
1299 msgstr "This chip has encountered a chip-level uncorrectable error.\n  Refer to %s for more information."
1300 msgid "SUN4V-8002-HR.response"
1301 msgstr "The system will attempt to retire all strands in this chip.\n"
1302 msgid "SUN4V-8002-HR.impact"
1303 msgstr "System performance may be affected. \n"
1304 msgid "SUN4V-8002-HR.action"
1305 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1306 #
1307 # code: SUN4V-8002-J4
1308 # keys: fault.cpu.generic-sparc.chip-uc-nr
1309 #
1310 msgid "SUN4V-8002-J4.type"
1311 msgstr "Fault"
1312 msgid "SUN4V-8002-J4.severity"
1313 msgstr "Critical"
1314 msgid "SUN4V-8002-J4.description"
1315 msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n  Refer to %s for more information."
1316 msgid "SUN4V-8002-J4.response"
1317 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1318 msgid "SUN4V-8002-J4.impact"
1319 msgstr "System performance may be affected. \n"
1320 msgid "SUN4V-8002-J4.action"
1321 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1322 #
1323 # code: SUN4V-8002-KQ
1324 # keys: fault.cpu.generic-sparc.c2c
1325 #
1326 msgid "SUN4V-8002-KQ.type"
1327 msgstr "Fault"
1328 msgid "SUN4V-8002-KQ.severity"
1329 msgstr "Major"
1330 msgid "SUN4V-8002-KQ.description"
1331 msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n  Refer to %s for more information."
1332 msgid "SUN4V-8002-KQ.response"
1333 msgstr "No automated response.\n"
1334 msgid "SUN4V-8002-KQ.impact"
1335 msgstr "System performance may be affected.\n"
1336 msgid "SUN4V-8002-KQ.action"
1337 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1338 #
1339 # code: SUN4V-8002-LC
1340 # keys: fault.cpu.generic-sparc.c2c-failover
1341 #
1342 msgid "SUN4V-8002-LC.type"
1343 msgstr "Fault"
1344 msgid "SUN4V-8002-LC.severity"
1345 msgstr "Major"
1346 msgid "SUN4V-8002-LC.description"
1347 msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n  Refer to %s for more information."
1348 msgid "SUN4V-8002-LC.response"
1349 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1350 msgid "SUN4V-8002-LC.impact"
1351 msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n"
1352 msgid "SUN4V-8002-LC.action"
1353 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1354 #
1355 # code: SUN4V-8002-MJ
1356 # keys: fault.cpu.generic-sparc.c2c-uc
1357 #
1358 msgid "SUN4V-8002-MJ.type"
1359 msgstr "Fault"
1360 msgid "SUN4V-8002-MJ.severity"
1361 msgstr "Critical"
1362 msgid "SUN4V-8002-MJ.description"
1363 msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n  Refer to %s for more information."
1364 msgid "SUN4V-8002-MJ.response"
1365 msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n"
1366 msgid "SUN4V-8002-MJ.impact"
1367 msgstr "The system halts and must be restarted.  The integrity of this system has\nbeen compromised.\n"
1368 msgid "SUN4V-8002-MJ.action"
1369 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1370 #
1371 # code: SUN4V-8002-NE
1372 # keys: fault.memory.memlink
1373 #
1374 msgid "SUN4V-8002-NE.type"
1375 msgstr "Fault"
1376 msgid "SUN4V-8002-NE.severity"
1377 msgstr "Major"
1378 msgid "SUN4V-8002-NE.description"
1379 msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller.  No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n  Refer to %s for more information."
1380 msgid "SUN4V-8002-NE.response"
1381 msgstr "The system has recovered from the CRC errors.\n"
1382 msgid "SUN4V-8002-NE.impact"
1383 msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n"
1384 msgid "SUN4V-8002-NE.action"
1385 msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1386 #
1387 # code: SUN4V-8002-PX
1388 # keys: fault.memory.memlink-failover
1389 #
1390 msgid "SUN4V-8002-PX.type"
1391 msgstr "Fault"
1392 msgid "SUN4V-8002-PX.severity"
1393 msgstr "Major"
1394 msgid "SUN4V-8002-PX.description"
1395 msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller.  While no data has been lost, a lane failover\nhas taken place.\n  Refer to %s for more information."
1396 msgid "SUN4V-8002-PX.response"
1397 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1398 msgid "SUN4V-8002-PX.impact"
1399 msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n"
1400 msgid "SUN4V-8002-PX.action"
1401 msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n"
1402 #
1403 # code: SUN4V-8002-Q2
1404 # keys: fault.memory.memlink-uc
1405 #
1406 msgid "SUN4V-8002-Q2.type"
1407 msgstr "Fault"
1408 msgid "SUN4V-8002-Q2.severity"
1409 msgstr "Critical"
1410 msgid "SUN4V-8002-Q2.description"
1411 msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n  Refer to %s for more information."
1412 msgid "SUN4V-8002-Q2.response"
1413 msgstr "The system crashed to prevent data corruption.  Memory in the affected\npartition may have been deconfigured.  (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n"
1414 msgid "SUN4V-8002-Q2.impact"
1415 msgstr "If memory has been deconfigured, system performance may be impacted. \n"
1416 msgid "SUN4V-8002-Q2.action"
1417 msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n"
1418 #
1419 # code: SUN4V-8002-RA
1420 # keys: defect.fw.generic-sparc.addr-oob
1421 #
1422 msgid "SUN4V-8002-RA.type"
1423 msgstr "Fault"
1424 msgid "SUN4V-8002-RA.severity"
1425 msgstr "Critical"
1426 msgid "SUN4V-8002-RA.description"
1427 msgstr "An address-out-of-bounds error has occurred.\n  Refer to %s for more information."
1428 msgid "SUN4V-8002-RA.response"
1429 msgstr "No automated response.\n"
1430 msgid "SUN4V-8002-RA.impact"
1431 msgstr "The system may have taken a fatal reset.\n"
1432 msgid "SUN4V-8002-RA.action"
1433 msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n"
1434 #
1435 # code: SUN4V-8002-SP
1436 # keys: defect.fw.generic-sparc.erpt-gen
1437 #
1438 msgid "SUN4V-8002-SP.type"
1439 msgstr "Fault"
1440 msgid "SUN4V-8002-SP.severity"
1441 msgstr "Major"
1442 msgid "SUN4V-8002-SP.description"
1443 msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n  Refer to %s for more information."
1444 msgid "SUN4V-8002-SP.response"
1445 msgstr "No automated response.\n"
1446 msgid "SUN4V-8002-SP.impact"
1447 msgstr "This error does not affect system operation.  The error which\ncould not be reported may have more serious impact which cannot be determined.\n"
1448 msgid "SUN4V-8002-SP.action"
1449 msgstr "Call your service provider to determine if your system requires a firmware\nupgrade.  Please retain the error log file.\n"
1450 #
1451 # code: SUN4V-8002-T5
1452 # keys: fault.cpu.generic-sparc.bootbus
1453 #
1454 msgid "SUN4V-8002-T5.type"
1455 msgstr "Fault"
1456 msgid "SUN4V-8002-T5.severity"
1457 msgstr "Critical"
1458 msgid "SUN4V-8002-T5.description"
1459 msgstr "A system boot bus error has occurred.\n  Refer to %s for more information."
1460 msgid "SUN4V-8002-T5.response"
1461 msgstr "No automated response.\n"
1462 msgid "SUN4V-8002-T5.impact"
1463 msgstr "The system's integrity is seriously compromised.  Processor chip(s)\nmay be unavailable.\n"
1464 msgid "SUN4V-8002-T5.action"
1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466 #
1467 # code: SUN4V-8002-US
1468 # keys: fault.sp.failed
1469 #
1470 msgid "SUN4V-8002-US.type"
1471 msgstr "Fault"
1472 msgid "SUN4V-8002-US.severity"
1473 msgstr "Critical"
1474 msgid "SUN4V-8002-US.description"
1475 msgstr "The Service Processor failed.\n  Refer to %s for more information."
1476 msgid "SUN4V-8002-US.response"
1477 msgstr "No automated response.\n"
1478 msgid "SUN4V-8002-US.impact"
1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 msgid "SUN4V-8002-US.action"
1481 msgstr "Schedule a repair procedure for the Service Processor, or contact your illumos distribution team for support.\n"