*** 559,571 **** msgid "SUN4U-8001-2X.type" msgstr "Defect" msgid "SUN4U-8001-2X.severity" msgstr "Minor" msgid "SUN4U-8001-2X.description" ! msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." msgid "SUN4U-8001-2X.response" ! msgstr "The error information has been saved for examination by Sun." msgid "SUN4U-8001-2X.impact" msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." msgid "SUN4U-8001-2X.action" msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors." # --- 559,571 ---- msgid "SUN4U-8001-2X.type" msgstr "Defect" msgid "SUN4U-8001-2X.severity" msgstr "Minor" msgid "SUN4U-8001-2X.description" ! msgstr "The illumos Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." msgid "SUN4U-8001-2X.response" ! msgstr "The error information has been saved for examination by your illumos distribution team." msgid "SUN4U-8001-2X.impact" msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." msgid "SUN4U-8001-2X.action" msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors." #
*** 577,587 **** msgid "SUN4U-8001-32.severity" msgstr "Major" msgid "SUN4U-8001-32.description" msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information." msgid "SUN4U-8001-32.response" ! msgstr "Error reports from the affected components will be logged for examination by Sun." msgid "SUN4U-8001-32.impact" msgstr "System performance and stability may be affected." msgid "SUN4U-8001-32.action" msgstr "Contact your service provider for further diagnosis." # --- 577,587 ---- msgid "SUN4U-8001-32.severity" msgstr "Major" msgid "SUN4U-8001-32.description" msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information." msgid "SUN4U-8001-32.response" ! msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team." msgid "SUN4U-8001-32.impact" msgstr "System performance and stability may be affected." msgid "SUN4U-8001-32.action" msgstr "Contact your service provider for further diagnosis." #
*** 597,607 **** msgid "SUN4U-8001-4R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-4R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-4R.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-54 # keys: defect.io.pci.driver fault.io.datapath # msgid "SUN4U-8001-54.type" --- 597,607 ---- msgid "SUN4U-8001-4R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-4R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-4R.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-54 # keys: defect.io.pci.driver fault.io.datapath # msgid "SUN4U-8001-54.type"
*** 613,623 **** msgid "SUN4U-8001-54.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-54.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-54.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-6Q # keys: fault.io.datapath fault.io.pci.bus # msgid "SUN4U-8001-6Q.type" --- 613,623 ---- msgid "SUN4U-8001-54.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-54.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-54.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-6Q # keys: fault.io.datapath fault.io.pci.bus # msgid "SUN4U-8001-6Q.type"
*** 629,639 **** msgid "SUN4U-8001-6Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-6Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-6Q.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-7C # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus # msgid "SUN4U-8001-7C.type" --- 629,639 ---- msgid "SUN4U-8001-6Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-6Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-6Q.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-7C # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus # msgid "SUN4U-8001-7C.type"
*** 645,655 **** msgid "SUN4U-8001-7C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-7C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-7C.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-83 # keys: fault.io.datapath fault.io.pci.device # msgid "SUN4U-8001-83.type" --- 645,655 ---- msgid "SUN4U-8001-7C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-7C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-7C.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-83 # keys: fault.io.datapath fault.io.pci.device # msgid "SUN4U-8001-83.type"
*** 661,671 **** msgid "SUN4U-8001-83.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-83.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-83.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-9Y # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device # msgid "SUN4U-8001-9Y.type" --- 661,671 ---- msgid "SUN4U-8001-83.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-83.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-83.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-9Y # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device # msgid "SUN4U-8001-9Y.type"
*** 677,687 **** msgid "SUN4U-8001-9Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-9Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-9Y.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-AD # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-AD.type" --- 677,687 ---- msgid "SUN4U-8001-9Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-9Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-9Y.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-AD # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-AD.type"
*** 693,703 **** msgid "SUN4U-8001-AD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-AD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-AD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-CH # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-CH.type" --- 693,703 ---- msgid "SUN4U-8001-AD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-AD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-AD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-CH # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-CH.type"
*** 709,719 **** msgid "SUN4U-8001-CH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-CH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-CH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-DA # keys: fault.io.hbus # msgid "SUN4U-8001-DA.type" --- 709,719 ---- msgid "SUN4U-8001-CH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-CH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-CH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-DA # keys: fault.io.hbus # msgid "SUN4U-8001-DA.type"
*** 725,735 **** msgid "SUN4U-8001-DA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-DA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-DA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-EP # keys: defect.io.pci.driver fault.io.hbus # msgid "SUN4U-8001-EP.type" --- 725,735 ---- msgid "SUN4U-8001-DA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-DA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-DA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-EP # keys: defect.io.pci.driver fault.io.hbus # msgid "SUN4U-8001-EP.type"
*** 741,751 **** msgid "SUN4U-8001-EP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-EP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-EP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-F5 # keys: fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-F5.type" --- 741,751 ---- msgid "SUN4U-8001-EP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-EP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-EP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-F5 # keys: fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-F5.type"
*** 757,767 **** msgid "SUN4U-8001-F5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-F5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-F5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-GS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-GS.type" --- 757,767 ---- msgid "SUN4U-8001-F5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-F5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-F5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-GS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-GS.type"
*** 773,783 **** msgid "SUN4U-8001-GS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-GS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-GS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-H2 # keys: fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-H2.type" --- 773,783 ---- msgid "SUN4U-8001-GS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-GS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-GS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-H2 # keys: fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-H2.type"
*** 789,799 **** msgid "SUN4U-8001-H2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-H2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-H2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-JX # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-JX.type" --- 789,799 ---- msgid "SUN4U-8001-H2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-H2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-H2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-JX # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-JX.type"
*** 805,815 **** msgid "SUN4U-8001-JX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-JX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-JX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-KE # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-KE.type" --- 805,815 ---- msgid "SUN4U-8001-JX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-JX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-JX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-KE # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-KE.type"
*** 821,831 **** msgid "SUN4U-8001-KE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-KE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-KE.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-LJ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-LJ.type" --- 821,831 ---- msgid "SUN4U-8001-KE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-KE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-KE.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-LJ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-LJ.type"
*** 837,847 **** msgid "SUN4U-8001-LJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-LJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-LJ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-MC # keys: fault.io.datapath fault.io.hbus # msgid "SUN4U-8001-MC.type" --- 837,847 ---- msgid "SUN4U-8001-LJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-LJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-LJ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-MC # keys: fault.io.datapath fault.io.hbus # msgid "SUN4U-8001-MC.type"
*** 853,863 **** msgid "SUN4U-8001-MC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-MC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-MC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-NQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus # msgid "SUN4U-8001-NQ.type" --- 853,863 ---- msgid "SUN4U-8001-MC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-MC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-MC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-NQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus # msgid "SUN4U-8001-NQ.type"
*** 869,879 **** msgid "SUN4U-8001-NQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-NQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-NQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-P4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-P4.type" --- 869,879 ---- msgid "SUN4U-8001-NQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-NQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-NQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-P4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-P4.type"
*** 885,895 **** msgid "SUN4U-8001-P4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-P4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-P4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-QR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-QR.type" --- 885,895 ---- msgid "SUN4U-8001-P4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-P4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-P4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-QR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-QR.type"
*** 901,911 **** msgid "SUN4U-8001-QR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-QR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-QR.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-RH # keys: fault.io.datapath fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-RH.type" --- 901,911 ---- msgid "SUN4U-8001-QR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-QR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-QR.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-RH # keys: fault.io.datapath fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-RH.type"
*** 917,927 **** msgid "SUN4U-8001-RH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-RH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-RH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-SD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-SD.type" --- 917,927 ---- msgid "SUN4U-8001-RH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-RH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-RH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-SD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-SD.type"
*** 933,943 **** msgid "SUN4U-8001-SD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-SD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-SD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-TY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-TY.type" --- 933,943 ---- msgid "SUN4U-8001-SD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-SD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-SD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-TY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-TY.type"
*** 949,959 **** msgid "SUN4U-8001-TY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-TY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-TY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-U3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-U3.type" --- 949,959 ---- msgid "SUN4U-8001-TY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-TY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-TY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-U3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-U3.type"
*** 965,975 **** msgid "SUN4U-8001-U3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-U3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-U3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-VS # keys: fault.io.schizo # msgid "SUN4U-8001-VS.type" --- 965,975 ---- msgid "SUN4U-8001-U3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-U3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-U3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-VS # keys: fault.io.schizo # msgid "SUN4U-8001-VS.type"
*** 981,991 **** msgid "SUN4U-8001-VS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-VS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-VS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-W5 # keys: defect.io.pci.driver fault.io.schizo # msgid "SUN4U-8001-W5.type" --- 981,991 ---- msgid "SUN4U-8001-VS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-VS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-VS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-W5 # keys: defect.io.pci.driver fault.io.schizo # msgid "SUN4U-8001-W5.type"
*** 997,1007 **** msgid "SUN4U-8001-W5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-W5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-W5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-XP # keys: fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8001-XP.type" --- 997,1007 ---- msgid "SUN4U-8001-W5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-W5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-W5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-XP # keys: fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8001-XP.type"
*** 1013,1023 **** msgid "SUN4U-8001-XP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-XP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-XP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-YA # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8001-YA.type" --- 1013,1023 ---- msgid "SUN4U-8001-XP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-XP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-XP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-YA # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8001-YA.type"
*** 1029,1039 **** msgid "SUN4U-8001-YA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-YA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-YA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-0R # keys: fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-0R.type" --- 1029,1039 ---- msgid "SUN4U-8001-YA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-YA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-YA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-0R # keys: fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-0R.type"
*** 1045,1055 **** msgid "SUN4U-8002-0R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-0R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-0R.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-14 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-14.type" --- 1045,1055 ---- msgid "SUN4U-8002-0R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-0R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-0R.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-14 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-14.type"
*** 1061,1071 **** msgid "SUN4U-8002-14.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-14.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-14.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-2Q # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-2Q.type" --- 1061,1071 ---- msgid "SUN4U-8002-14.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-14.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-14.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-2Q # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-2Q.type"
*** 1077,1087 **** msgid "SUN4U-8002-2Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-2Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-2Q.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-3C # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-3C.type" --- 1077,1087 ---- msgid "SUN4U-8002-2Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-2Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-2Q.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-3C # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-3C.type"
*** 1093,1103 **** msgid "SUN4U-8002-3C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-3C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-3C.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-4J # keys: fault.io.datapath fault.io.schizo # msgid "SUN4U-8002-4J.type" --- 1093,1103 ---- msgid "SUN4U-8002-3C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-3C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-3C.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-4J # keys: fault.io.datapath fault.io.schizo # msgid "SUN4U-8002-4J.type"
*** 1109,1119 **** msgid "SUN4U-8002-4J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-4J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-4J.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-5E # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo # msgid "SUN4U-8002-5E.type" --- 1109,1119 ---- msgid "SUN4U-8002-4J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-4J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-4J.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-5E # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo # msgid "SUN4U-8002-5E.type"
*** 1125,1135 **** msgid "SUN4U-8002-5E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-5E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-5E.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-6X # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-6X.type" --- 1125,1135 ---- msgid "SUN4U-8002-5E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-5E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-5E.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-6X # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-6X.type"
*** 1141,1151 **** msgid "SUN4U-8002-6X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-6X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-6X.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-72 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-72.type" --- 1141,1151 ---- msgid "SUN4U-8002-6X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-6X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-6X.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-72 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-72.type"
*** 1157,1167 **** msgid "SUN4U-8002-72.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-72.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-72.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-8A # keys: fault.io.datapath fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-8A.type" --- 1157,1167 ---- msgid "SUN4U-8002-72.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-72.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-72.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-8A # keys: fault.io.datapath fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-8A.type"
*** 1173,1183 **** msgid "SUN4U-8002-8A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-8A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-8A.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-9P # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-9P.type" --- 1173,1183 ---- msgid "SUN4U-8002-8A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-8A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-8A.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-9P # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-9P.type"
*** 1189,1199 **** msgid "SUN4U-8002-9P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-9P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-9P.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-A5 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-A5.type" --- 1189,1199 ---- msgid "SUN4U-8002-9P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-9P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-9P.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-A5 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-A5.type"
*** 1205,1215 **** msgid "SUN4U-8002-A5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-A5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-A5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-CS # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-CS.type" --- 1205,1215 ---- msgid "SUN4U-8002-A5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-A5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-A5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-CS # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-CS.type"
*** 1221,1231 **** msgid "SUN4U-8002-CS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-CS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-CS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-D3 # keys: fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-D3.type" --- 1221,1231 ---- msgid "SUN4U-8002-CS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-CS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-CS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-D3 # keys: fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-D3.type"
*** 1237,1247 **** msgid "SUN4U-8002-D3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-D3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-D3.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-EY # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-EY.type" --- 1237,1247 ---- msgid "SUN4U-8002-D3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-D3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-D3.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-EY # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-EY.type"
*** 1253,1263 **** msgid "SUN4U-8002-EY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-EY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-EY.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-FD # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-FD.type" --- 1253,1263 ---- msgid "SUN4U-8002-EY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-EY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-EY.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-FD # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-FD.type"
*** 1269,1279 **** msgid "SUN4U-8002-FD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-FD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-FD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-GH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-GH.type" --- 1269,1279 ---- msgid "SUN4U-8002-FD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-FD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-FD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-GH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-GH.type"
*** 1285,1295 **** msgid "SUN4U-8002-GH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-GH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-GH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-HC # keys: fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-HC.type" --- 1285,1295 ---- msgid "SUN4U-8002-GH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-GH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-GH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-HC # keys: fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-HC.type"
*** 1301,1311 **** msgid "SUN4U-8002-HC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-HC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-HC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-JQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-JQ.type" --- 1301,1311 ---- msgid "SUN4U-8002-HC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-HC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-HC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-JQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-JQ.type"
*** 1317,1327 **** msgid "SUN4U-8002-JQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-JQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-JQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-K4 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-K4.type" --- 1317,1327 ---- msgid "SUN4U-8002-JQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-JQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-JQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-K4 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-K4.type"
*** 1333,1343 **** msgid "SUN4U-8002-K4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-K4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-K4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-LR # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-LR.type" --- 1333,1343 ---- msgid "SUN4U-8002-K4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-K4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-K4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-LR # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-LR.type"
*** 1349,1359 **** msgid "SUN4U-8002-LR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-LR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-LR.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-M2 # keys: fault.io.datapath fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-M2.type" --- 1349,1359 ---- msgid "SUN4U-8002-LR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-LR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-LR.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-M2 # keys: fault.io.datapath fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-M2.type"
*** 1365,1375 **** msgid "SUN4U-8002-M2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-M2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-M2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-NX # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-NX.type" --- 1365,1375 ---- msgid "SUN4U-8002-M2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-M2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-M2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-NX # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-NX.type"
*** 1381,1391 **** msgid "SUN4U-8002-NX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-NX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-NX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-PE # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-PE.type" --- 1381,1391 ---- msgid "SUN4U-8002-NX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-NX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-NX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-PE # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-PE.type"
*** 1397,1407 **** msgid "SUN4U-8002-PE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-PE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-PE.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-QJ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-QJ.type" --- 1397,1407 ---- msgid "SUN4U-8002-PE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-PE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-PE.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-QJ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-QJ.type"
*** 1413,1423 **** msgid "SUN4U-8002-QJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-QJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-QJ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-RS # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-RS.type" --- 1413,1423 ---- msgid "SUN4U-8002-QJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-QJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-QJ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-RS # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-RS.type"
*** 1429,1439 **** msgid "SUN4U-8002-RS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-RS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-RS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-S5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-S5.type" --- 1429,1439 ---- msgid "SUN4U-8002-RS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-RS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-RS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-S5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-S5.type"
*** 1445,1455 **** msgid "SUN4U-8002-S5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-S5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-S5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-TP # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-TP.type" --- 1445,1455 ---- msgid "SUN4U-8002-S5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-S5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-S5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-TP # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-TP.type"
*** 1461,1471 **** msgid "SUN4U-8002-TP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-TP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-TP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-UA # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-UA.type" --- 1461,1471 ---- msgid "SUN4U-8002-TP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-TP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-TP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-UA # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-UA.type"
*** 1477,1487 **** msgid "SUN4U-8002-UA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-UA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-UA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-VH # keys: fault.io.xmits # msgid "SUN4U-8002-VH.type" --- 1477,1487 ---- msgid "SUN4U-8002-UA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-UA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-UA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-VH # keys: fault.io.xmits # msgid "SUN4U-8002-VH.type"
*** 1493,1503 **** msgid "SUN4U-8002-VH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-VH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-VH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-WD # keys: defect.io.pci.driver fault.io.xmits # msgid "SUN4U-8002-WD.type" --- 1493,1503 ---- msgid "SUN4U-8002-VH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-VH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-VH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-WD # keys: defect.io.pci.driver fault.io.xmits # msgid "SUN4U-8002-WD.type"
*** 1509,1519 **** msgid "SUN4U-8002-WD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-WD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-WD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-XY # keys: fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8002-XY.type" --- 1509,1519 ---- msgid "SUN4U-8002-WD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-WD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-WD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-XY # keys: fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8002-XY.type"
*** 1525,1535 **** msgid "SUN4U-8002-XY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-XY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-XY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-Y3 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8002-Y3.type" --- 1525,1535 ---- msgid "SUN4U-8002-XY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-XY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-XY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-Y3 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8002-Y3.type"
*** 1541,1551 **** msgid "SUN4U-8002-Y3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-Y3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-Y3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-0Y # keys: fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-0Y.type" --- 1541,1551 ---- msgid "SUN4U-8002-Y3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-Y3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-Y3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-0Y # keys: fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-0Y.type"
*** 1557,1567 **** msgid "SUN4U-8003-0Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-0Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-0Y.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-13 # keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-13.type" --- 1557,1567 ---- msgid "SUN4U-8003-0Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-0Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-0Y.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-13 # keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-13.type"
*** 1573,1583 **** msgid "SUN4U-8003-13.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-13.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-13.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-2H # keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-2H.type" --- 1573,1583 ---- msgid "SUN4U-8003-13.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-13.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-13.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-2H # keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-2H.type"
*** 1589,1599 **** msgid "SUN4U-8003-2H.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-2H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-2H.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-3D # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-3D.type" --- 1589,1599 ---- msgid "SUN4U-8003-2H.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-2H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-2H.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-3D # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-3D.type"
*** 1605,1615 **** msgid "SUN4U-8003-3D.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-3D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-3D.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-4P # keys: fault.io.datapath fault.io.xmits # msgid "SUN4U-8003-4P.type" --- 1605,1615 ---- msgid "SUN4U-8003-3D.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-3D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-3D.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-4P # keys: fault.io.datapath fault.io.xmits # msgid "SUN4U-8003-4P.type"
*** 1621,1631 **** msgid "SUN4U-8003-4P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-4P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-4P.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-5A # keys: defect.io.pci.driver fault.io.datapath fault.io.xmits # msgid "SUN4U-8003-5A.type" --- 1621,1631 ---- msgid "SUN4U-8003-4P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-4P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-4P.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-5A # keys: defect.io.pci.driver fault.io.datapath fault.io.xmits # msgid "SUN4U-8003-5A.type"
*** 1637,1647 **** msgid "SUN4U-8003-5A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-5A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-5A.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-6S # keys: fault.io.datapath fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-6S.type" --- 1637,1647 ---- msgid "SUN4U-8003-5A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-5A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-5A.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-6S # keys: fault.io.datapath fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-6S.type"
*** 1653,1663 **** msgid "SUN4U-8003-6S.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-6S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-6S.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-75 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-75.type" --- 1653,1663 ---- msgid "SUN4U-8003-6S.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-6S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-6S.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-75 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-75.type"
*** 1669,1679 **** msgid "SUN4U-8003-75.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-75.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-75.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-8E # keys: fault.io.datapath fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-8E.type" --- 1669,1679 ---- msgid "SUN4U-8003-75.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-75.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-75.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-8E # keys: fault.io.datapath fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-8E.type"
*** 1685,1695 **** msgid "SUN4U-8003-8E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-8E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-8E.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-9J # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-9J.type" --- 1685,1695 ---- msgid "SUN4U-8003-8E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-8E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-8E.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-9J # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-9J.type"
*** 1701,1711 **** msgid "SUN4U-8003-9J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-9J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-9J.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-A2 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-A2.type" --- 1701,1711 ---- msgid "SUN4U-8003-9J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-9J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-9J.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-A2 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-A2.type"
*** 1717,1727 **** msgid "SUN4U-8003-A2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-A2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-A2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-CX # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-CX.type" --- 1717,1727 ---- msgid "SUN4U-8003-A2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-A2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-A2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-CX # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-CX.type"
*** 1733,1743 **** msgid "SUN4U-8003-CX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-CX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-CX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-D4 # keys: fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-D4.type" --- 1733,1743 ---- msgid "SUN4U-8003-CX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-CX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-CX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-D4 # keys: fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-D4.type"
*** 1749,1759 **** msgid "SUN4U-8003-D4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-D4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-D4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-ER # keys: defect.io.pci.driver fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-ER.type" --- 1749,1759 ---- msgid "SUN4U-8003-D4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-D4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-D4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-ER # keys: defect.io.pci.driver fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-ER.type"
*** 1765,1775 **** msgid "SUN4U-8003-ER.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-ER.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-ER.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-FC # keys: fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-FC.type" --- 1765,1775 ---- msgid "SUN4U-8003-ER.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-ER.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-ER.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-FC # keys: fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-FC.type"
*** 1781,1791 **** msgid "SUN4U-8003-FC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-FC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-FC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-GQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-GQ.type" --- 1781,1791 ---- msgid "SUN4U-8003-FC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-FC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-FC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-GQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-GQ.type"
*** 1797,1807 **** msgid "SUN4U-8003-GQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-GQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-GQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-HD # keys: fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-HD.type" --- 1797,1807 ---- msgid "SUN4U-8003-GQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-GQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-GQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-HD # keys: fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-HD.type"
*** 1813,1823 **** msgid "SUN4U-8003-HD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-HD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-HD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-JH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-JH.type" --- 1813,1823 ---- msgid "SUN4U-8003-HD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-HD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-HD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-JH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-JH.type"
*** 1829,1839 **** msgid "SUN4U-8003-JH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-JH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-JH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-K3 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-K3.type" --- 1829,1839 ---- msgid "SUN4U-8003-JH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-JH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-JH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-K3 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-K3.type"
*** 1845,1855 **** msgid "SUN4U-8003-K3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-K3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-K3.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-LY # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-LY.type" --- 1845,1855 ---- msgid "SUN4U-8003-K3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-K3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-K3.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-LY # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-LY.type"
*** 1861,1871 **** msgid "SUN4U-8003-LY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-LY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-LY.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-M5 # keys: fault.io.datapath fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-M5.type" --- 1861,1871 ---- msgid "SUN4U-8003-LY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-LY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-LY.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-M5 # keys: fault.io.datapath fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-M5.type"
*** 1877,1887 **** msgid "SUN4U-8003-M5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-M5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-M5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-NS # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-NS.type" --- 1877,1887 ---- msgid "SUN4U-8003-M5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-M5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-M5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-NS # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-NS.type"
*** 1893,1903 **** msgid "SUN4U-8003-NS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-NS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-NS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-PA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-PA.type" --- 1893,1903 ---- msgid "SUN4U-8003-NS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-NS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-NS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-PA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-PA.type"
*** 1909,1919 **** msgid "SUN4U-8003-PA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-PA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-PA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-QP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-QP.type" --- 1909,1919 ---- msgid "SUN4U-8003-PA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-PA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-PA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-QP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-QP.type"
*** 1925,1935 **** msgid "SUN4U-8003-QP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-QP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-QP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-RX # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-RX.type" --- 1925,1935 ---- msgid "SUN4U-8003-QP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-QP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-QP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-RX # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-RX.type"
*** 1941,1951 **** msgid "SUN4U-8003-RX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-RX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-RX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-S2 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-S2.type" --- 1941,1951 ---- msgid "SUN4U-8003-RX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-RX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-RX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-S2 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-S2.type"
*** 1957,1967 **** msgid "SUN4U-8003-S2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-S2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-S2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-TJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-TJ.type" --- 1957,1967 ---- msgid "SUN4U-8003-S2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-S2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-S2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-TJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-TJ.type"
*** 1973,1983 **** msgid "SUN4U-8003-TJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-TJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-TJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-UE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-UE.type" --- 1973,1983 ---- msgid "SUN4U-8003-TJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-TJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-TJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-UE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-UE.type"
*** 1989,1999 **** msgid "SUN4U-8003-UE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-UE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-UE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-VQ # keys: fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-VQ.type" --- 1989,1999 ---- msgid "SUN4U-8003-UE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-UE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-UE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-VQ # keys: fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-VQ.type"
*** 2005,2015 **** msgid "SUN4U-8003-VQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-VQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-VQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-WC # keys: defect.io.pci.driver fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-WC.type" --- 2005,2015 ---- msgid "SUN4U-8003-VQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-VQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-VQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-WC # keys: defect.io.pci.driver fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-WC.type"
*** 2021,2031 **** msgid "SUN4U-8003-WC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-WC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-WC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-XR # keys: fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-XR.type" --- 2021,2031 ---- msgid "SUN4U-8003-WC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-WC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-WC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-XR # keys: fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-XR.type"
*** 2037,2047 **** msgid "SUN4U-8003-XR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-XR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-XR.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-Y4 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-Y4.type" --- 2037,2047 ---- msgid "SUN4U-8003-XR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-XR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-XR.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-Y4 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-Y4.type"
*** 2053,2063 **** msgid "SUN4U-8003-Y4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-Y4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-Y4.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-0A # keys: fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-0A.type" --- 2053,2063 ---- msgid "SUN4U-8003-Y4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-Y4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-Y4.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-0A # keys: fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-0A.type"
*** 2069,2079 **** msgid "SUN4U-8004-0A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-0A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-0A.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-1P # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-1P.type" --- 2069,2079 ---- msgid "SUN4U-8004-0A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-0A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-0A.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-1P # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-1P.type"
*** 2085,2095 **** msgid "SUN4U-8004-1P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-1P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-1P.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-25 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-25.type" --- 2085,2095 ---- msgid "SUN4U-8004-1P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-1P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-1P.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-25 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-25.type"
*** 2101,2111 **** msgid "SUN4U-8004-25.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-25.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-25.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-3S # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-3S.type" --- 2101,2111 ---- msgid "SUN4U-8004-25.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-25.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-25.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-3S # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-3S.type"
*** 2117,2127 **** msgid "SUN4U-8004-3S.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-3S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-3S.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-43 # keys: fault.io.datapath fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-43.type" --- 2117,2127 ---- msgid "SUN4U-8004-3S.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-3S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-3S.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-43 # keys: fault.io.datapath fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-43.type"
*** 2133,2143 **** msgid "SUN4U-8004-43.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-43.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-43.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-5Y # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-5Y.type" --- 2133,2143 ---- msgid "SUN4U-8004-43.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-43.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-43.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-5Y # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-5Y.type"
*** 2149,2159 **** msgid "SUN4U-8004-5Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-5Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-5Y.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-6D # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-6D.type" --- 2149,2159 ---- msgid "SUN4U-8004-5Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-5Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-5Y.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-6D # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-6D.type"
*** 2165,2175 **** msgid "SUN4U-8004-6D.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-6D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-6D.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-7H # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-7H.type" --- 2165,2175 ---- msgid "SUN4U-8004-6D.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-6D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-6D.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-7H # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-7H.type"
*** 2181,2191 **** msgid "SUN4U-8004-7H.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-7H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-7H.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-8R # keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-8R.type" --- 2181,2191 ---- msgid "SUN4U-8004-7H.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-7H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-7H.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-8R # keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-8R.type"
*** 2197,2207 **** msgid "SUN4U-8004-8R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-8R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-8R.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-94 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-94.type" --- 2197,2207 ---- msgid "SUN4U-8004-8R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-8R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-8R.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-94 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-94.type"
*** 2213,2223 **** msgid "SUN4U-8004-94.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-94.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-94.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-AQ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-AQ.type" --- 2213,2223 ---- msgid "SUN4U-8004-94.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-94.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-94.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-AQ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-AQ.type"
*** 2229,2239 **** msgid "SUN4U-8004-AQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-AQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-AQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-CC # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-CC.type" --- 2229,2239 ---- msgid "SUN4U-8004-AQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-AQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-AQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-CC # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-CC.type"
*** 2245,2255 **** msgid "SUN4U-8004-CC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-CC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-CC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-DJ # keys: fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-DJ.type" --- 2245,2255 ---- msgid "SUN4U-8004-CC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-CC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-CC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-DJ # keys: fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-DJ.type"
*** 2261,2271 **** msgid "SUN4U-8004-DJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-DJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-DJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-EE # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-EE.type" --- 2261,2271 ---- msgid "SUN4U-8004-DJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-DJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-DJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-EE # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-EE.type"
*** 2277,2287 **** msgid "SUN4U-8004-EE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-EE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-EE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-FX # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-FX.type" --- 2277,2287 ---- msgid "SUN4U-8004-EE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-EE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-EE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-FX # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-FX.type"
*** 2293,2303 **** msgid "SUN4U-8004-FX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-FX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-FX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-G2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-G2.type" --- 2293,2303 ---- msgid "SUN4U-8004-FX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-FX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-FX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-G2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-G2.type"
*** 2309,2319 **** msgid "SUN4U-8004-G2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-G2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-G2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-HS # keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-HS.type" --- 2309,2319 ---- msgid "SUN4U-8004-G2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-G2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-G2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-HS # keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-HS.type"
*** 2325,2335 **** msgid "SUN4U-8004-HS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-HS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-HS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-J5 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-J5.type" --- 2325,2335 ---- msgid "SUN4U-8004-HS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-HS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-HS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-J5 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-J5.type"
*** 2341,2351 **** msgid "SUN4U-8004-J5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-J5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-J5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-KP # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-KP.type" --- 2341,2351 ---- msgid "SUN4U-8004-J5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-J5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-J5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-KP # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-KP.type"
*** 2357,2367 **** msgid "SUN4U-8004-KP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-KP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-KP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-LA # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-LA.type" --- 2357,2367 ---- msgid "SUN4U-8004-KP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-KP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-KP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-LA # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-LA.type"
*** 2373,2383 **** msgid "SUN4U-8004-LA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-LA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-LA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-MH # keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-MH.type" --- 2373,2383 ---- msgid "SUN4U-8004-LA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-LA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-LA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-MH # keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-MH.type"
*** 2389,2399 **** msgid "SUN4U-8004-MH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-MH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-MH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-ND # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-ND.type" --- 2389,2399 ---- msgid "SUN4U-8004-MH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-MH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-MH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-ND # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-ND.type"
*** 2405,2415 **** msgid "SUN4U-8004-ND.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-ND.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-ND.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-PY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-PY.type" --- 2405,2415 ---- msgid "SUN4U-8004-ND.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-ND.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-ND.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-PY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-PY.type"
*** 2421,2431 **** msgid "SUN4U-8004-PY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-PY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-PY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-Q3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-Q3.type" --- 2421,2431 ---- msgid "SUN4U-8004-PY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-PY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-PY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-Q3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-Q3.type"
*** 2437,2447 **** msgid "SUN4U-8004-Q3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-Q3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-Q3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-RC # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-RC.type" --- 2437,2447 ---- msgid "SUN4U-8004-Q3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-Q3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-Q3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-RC # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-RC.type"
*** 2453,2463 **** msgid "SUN4U-8004-RC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-RC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-RC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-SQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-SQ.type" --- 2453,2463 ---- msgid "SUN4U-8004-RC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-RC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-RC.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-SQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-SQ.type"
*** 2469,2479 **** msgid "SUN4U-8004-SQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-SQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-SQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-T4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-T4.type" --- 2469,2479 ---- msgid "SUN4U-8004-SQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-SQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-SQ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-T4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-T4.type"
*** 2485,2495 **** msgid "SUN4U-8004-T4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-T4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-T4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-UR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-UR.type" --- 2485,2495 ---- msgid "SUN4U-8004-T4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-T4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-T4.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-UR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-UR.type"
*** 2501,2511 **** msgid "SUN4U-8004-UR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-UR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-UR.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-V2 # keys: fault.io.psycho # msgid "SUN4U-8004-V2.type" --- 2501,2511 ---- msgid "SUN4U-8004-UR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-UR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-UR.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-V2 # keys: fault.io.psycho # msgid "SUN4U-8004-V2.type"
*** 2517,2527 **** msgid "SUN4U-8004-V2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-V2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-V2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-WX # keys: defect.io.pci.driver fault.io.psycho # msgid "SUN4U-8004-WX.type" --- 2517,2527 ---- msgid "SUN4U-8004-V2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-V2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-V2.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-WX # keys: defect.io.pci.driver fault.io.psycho # msgid "SUN4U-8004-WX.type"
*** 2533,2543 **** msgid "SUN4U-8004-WX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-WX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-WX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-XE # keys: fault.io.datapath fault.io.psycho # msgid "SUN4U-8004-XE.type" --- 2533,2543 ---- msgid "SUN4U-8004-WX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-WX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-WX.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-XE # keys: fault.io.datapath fault.io.psycho # msgid "SUN4U-8004-XE.type"
*** 2549,2559 **** msgid "SUN4U-8004-XE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-XE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-XE.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-YJ # keys: defect.io.pci.driver fault.io.datapath fault.io.psycho # msgid "SUN4U-8004-YJ.type" --- 2549,2559 ---- msgid "SUN4U-8004-XE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-XE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-XE.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-YJ # keys: defect.io.pci.driver fault.io.datapath fault.io.psycho # msgid "SUN4U-8004-YJ.type"
*** 2565,2575 **** msgid "SUN4U-8004-YJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-YJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-YJ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-0E # keys: fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-0E.type" --- 2565,2575 ---- msgid "SUN4U-8004-YJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-YJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-YJ.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-0E # keys: fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-0E.type"
*** 2581,2591 **** msgid "SUN4U-8005-0E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-0E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-0E.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-1J # keys: defect.io.pci.driver fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-1J.type" --- 2581,2591 ---- msgid "SUN4U-8005-0E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-0E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-0E.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-1J # keys: defect.io.pci.driver fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-1J.type"
*** 2597,2607 **** msgid "SUN4U-8005-1J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-1J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-1J.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-22 # keys: fault.io.datapath fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-22.type" --- 2597,2607 ---- msgid "SUN4U-8005-1J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-1J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-1J.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-22 # keys: fault.io.datapath fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-22.type"
*** 2613,2623 **** msgid "SUN4U-8005-22.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-22.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-22.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-3X # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-3X.type" --- 2613,2623 ---- msgid "SUN4U-8005-22.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-22.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-22.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-3X # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-3X.type"
*** 2629,2639 **** msgid "SUN4U-8005-3X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-3X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-3X.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-44 # keys: fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-44.type" --- 2629,2639 ---- msgid "SUN4U-8005-3X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-3X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-3X.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-44 # keys: fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-44.type"
*** 2645,2655 **** msgid "SUN4U-8005-44.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-44.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-44.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-5R # keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-5R.type" --- 2645,2655 ---- msgid "SUN4U-8005-44.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-44.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-44.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-5R # keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-5R.type"
*** 2661,2671 **** msgid "SUN4U-8005-5R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-5R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-5R.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-6C # keys: fault.io.datapath fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-6C.type" --- 2661,2671 ---- msgid "SUN4U-8005-5R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-5R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-5R.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-6C # keys: fault.io.datapath fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-6C.type"
*** 2677,2687 **** msgid "SUN4U-8005-6C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-6C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-6C.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-7Q # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-7Q.type" --- 2677,2687 ---- msgid "SUN4U-8005-6C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-6C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-6C.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-7Q # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-7Q.type"
*** 2693,2703 **** msgid "SUN4U-8005-7Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-7Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-7Q.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-8Y # keys: fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-8Y.type" --- 2693,2703 ---- msgid "SUN4U-8005-7Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-7Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-7Q.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-8Y # keys: fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-8Y.type"
*** 2709,2719 **** msgid "SUN4U-8005-8Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-8Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-8Y.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-93 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-93.type" --- 2709,2719 ---- msgid "SUN4U-8005-8Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-8Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-8Y.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-93 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-93.type"
*** 2725,2735 **** msgid "SUN4U-8005-93.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-93.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-93.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-AH # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-AH.type" --- 2725,2735 ---- msgid "SUN4U-8005-93.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-93.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-93.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-AH # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-AH.type"
*** 2741,2751 **** msgid "SUN4U-8005-AH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-AH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-AH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-CD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-CD.type" --- 2741,2751 ---- msgid "SUN4U-8005-AH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-AH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-AH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-CD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-CD.type"
*** 2757,2767 **** msgid "SUN4U-8005-CD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-CD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-CD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-DP # keys: fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-DP.type" --- 2757,2767 ---- msgid "SUN4U-8005-CD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-CD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-CD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-DP # keys: fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-DP.type"
*** 2773,2783 **** msgid "SUN4U-8005-DP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-DP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-DP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-EA # keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-EA.type" --- 2773,2783 ---- msgid "SUN4U-8005-DP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-DP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-DP.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-EA # keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-EA.type"
*** 2789,2799 **** msgid "SUN4U-8005-EA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-EA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-EA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-FS # keys: fault.io.datapath fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-FS.type" --- 2789,2799 ---- msgid "SUN4U-8005-EA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-EA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-EA.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-FS # keys: fault.io.datapath fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-FS.type"
*** 2805,2815 **** msgid "SUN4U-8005-FS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-FS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-FS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-G5 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-G5.type" --- 2805,2815 ---- msgid "SUN4U-8005-FS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-FS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-FS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-G5 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-G5.type"
*** 2821,2831 **** msgid "SUN4U-8005-G5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-G5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-G5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-HX # keys: fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-HX.type" --- 2821,2831 ---- msgid "SUN4U-8005-G5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-G5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-G5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-HX # keys: fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-HX.type"
*** 2837,2847 **** msgid "SUN4U-8005-HX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-HX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-HX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-J2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-J2.type" --- 2837,2847 ---- msgid "SUN4U-8005-HX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-HX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-HX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-J2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-J2.type"
*** 2853,2863 **** msgid "SUN4U-8005-J2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-J2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-J2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-KJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-KJ.type" --- 2853,2863 ---- msgid "SUN4U-8005-J2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-J2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-J2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-KJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-KJ.type"
*** 2869,2879 **** msgid "SUN4U-8005-KJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-KJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-KJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-LE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-LE.type" --- 2869,2879 ---- msgid "SUN4U-8005-KJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-KJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-KJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-LE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-LE.type"
*** 2885,2895 **** msgid "SUN4U-8005-LE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-LE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-LE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-MQ # keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-MQ.type" --- 2885,2895 ---- msgid "SUN4U-8005-LE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-LE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-LE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-MQ # keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-MQ.type"
*** 2901,2911 **** msgid "SUN4U-8005-MQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-MQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-MQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-NC # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-NC.type" --- 2901,2911 ---- msgid "SUN4U-8005-MQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-MQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-MQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-NC # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-NC.type"
*** 2917,2927 **** msgid "SUN4U-8005-NC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-NC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-NC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-PR # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-PR.type" --- 2917,2927 ---- msgid "SUN4U-8005-NC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-NC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-NC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-PR # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-PR.type"
*** 2933,2943 **** msgid "SUN4U-8005-PR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-PR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-PR.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-Q4 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-Q4.type" --- 2933,2943 ---- msgid "SUN4U-8005-PR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-PR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-PR.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-Q4 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-Q4.type"
*** 2949,2959 **** msgid "SUN4U-8005-Q4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-Q4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-Q4.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-RD # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-RD.type" --- 2949,2959 ---- msgid "SUN4U-8005-Q4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-Q4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-Q4.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-RD # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-RD.type"
*** 2965,2975 **** msgid "SUN4U-8005-RD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-RD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-RD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-SH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-SH.type" --- 2965,2975 ---- msgid "SUN4U-8005-RD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-RD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-RD.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-SH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-SH.type"
*** 2981,2991 **** msgid "SUN4U-8005-SH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-SH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-SH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-T3 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-T3.type" --- 2981,2991 ---- msgid "SUN4U-8005-SH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-SH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-SH.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-T3 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-T3.type"
*** 2997,3007 **** msgid "SUN4U-8005-T3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-T3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-T3.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-UY # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-UY.type" --- 2997,3007 ---- msgid "SUN4U-8005-T3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-T3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-T3.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-UY # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-UY.type"
*** 3013,3023 **** msgid "SUN4U-8005-UY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-UY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-UY.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-V5 # keys: fault.io.tomatillo # msgid "SUN4U-8005-V5.type" --- 3013,3023 ---- msgid "SUN4U-8005-UY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-UY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-UY.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-V5 # keys: fault.io.tomatillo # msgid "SUN4U-8005-V5.type"
*** 3029,3039 **** msgid "SUN4U-8005-V5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-V5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-V5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-WS # keys: defect.io.pci.driver fault.io.tomatillo # msgid "SUN4U-8005-WS.type" --- 3029,3039 ---- msgid "SUN4U-8005-V5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-V5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-V5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-WS # keys: defect.io.pci.driver fault.io.tomatillo # msgid "SUN4U-8005-WS.type"
*** 3045,3055 **** msgid "SUN4U-8005-WS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-WS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-WS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-XA # keys: fault.io.datapath fault.io.tomatillo # msgid "SUN4U-8005-XA.type" --- 3045,3055 ---- msgid "SUN4U-8005-WS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-WS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-WS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-XA # keys: fault.io.datapath fault.io.tomatillo # msgid "SUN4U-8005-XA.type"
*** 3061,3071 **** msgid "SUN4U-8005-XA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-XA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-XA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-YP # keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo # msgid "SUN4U-8005-YP.type" --- 3061,3071 ---- msgid "SUN4U-8005-XA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-XA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-XA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-YP # keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo # msgid "SUN4U-8005-YP.type"
*** 3077,3087 **** msgid "SUN4U-8005-YP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-YP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-YP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-04 # keys: fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-04.type" --- 3077,3087 ---- msgid "SUN4U-8005-YP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-YP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-YP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-04 # keys: fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-04.type"
*** 3093,3103 **** msgid "SUN4U-8006-04.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-04.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-04.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-1R # keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-1R.type" --- 3093,3103 ---- msgid "SUN4U-8006-04.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-04.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-04.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-1R # keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-1R.type"
*** 3109,3119 **** msgid "SUN4U-8006-1R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-1R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-1R.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-2C # keys: fault.io.datapath fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-2C.type" --- 3109,3119 ---- msgid "SUN4U-8006-1R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-1R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-1R.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-2C # keys: fault.io.datapath fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-2C.type"
*** 3125,3135 **** msgid "SUN4U-8006-2C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-2C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-2C.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-3Q # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-3Q.type" --- 3125,3135 ---- msgid "SUN4U-8006-2C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-2C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-2C.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-3Q # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-3Q.type"
*** 3141,3151 **** msgid "SUN4U-8006-3Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-3Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-3Q.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-4E # keys: fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-4E.type" --- 3141,3151 ---- msgid "SUN4U-8006-3Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-3Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-3Q.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-4E # keys: fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-4E.type"
*** 3157,3167 **** msgid "SUN4U-8006-4E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-4E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-4E.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-5J # keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-5J.type" --- 3157,3167 ---- msgid "SUN4U-8006-4E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-4E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-4E.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-5J # keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-5J.type"
*** 3173,3183 **** msgid "SUN4U-8006-5J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-5J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-5J.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-62 # keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-62.type" --- 3173,3183 ---- msgid "SUN4U-8006-5J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-5J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-5J.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-62 # keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-62.type"
*** 3189,3199 **** msgid "SUN4U-8006-62.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-62.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-62.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-7X # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-7X.type" --- 3189,3199 ---- msgid "SUN4U-8006-62.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-62.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-62.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-7X # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-7X.type"
*** 3205,3215 **** msgid "SUN4U-8006-7X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-7X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-7X.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-8P # keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-8P.type" --- 3205,3215 ---- msgid "SUN4U-8006-7X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-7X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-7X.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-8P # keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-8P.type"
*** 3221,3231 **** msgid "SUN4U-8006-8P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-8P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-8P.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-9A # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-9A.type" --- 3221,3231 ---- msgid "SUN4U-8006-8P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-8P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-8P.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-9A # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-9A.type"
*** 3237,3247 **** msgid "SUN4U-8006-9A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-9A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-9A.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-AS # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-AS.type" --- 3237,3247 ---- msgid "SUN4U-8006-9A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-9A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-9A.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-AS # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-AS.type"
*** 3253,3263 **** msgid "SUN4U-8006-AS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-AS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-AS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-C5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-C5.type" --- 3253,3263 ---- msgid "SUN4U-8006-AS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-AS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-AS.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-C5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-C5.type"
*** 3269,3279 **** msgid "SUN4U-8006-C5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-C5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-C5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-DY # keys: fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-DY.type" --- 3269,3279 ---- msgid "SUN4U-8006-C5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-C5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-C5.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-DY # keys: fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-DY.type"
*** 3285,3295 **** msgid "SUN4U-8006-DY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-DY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-DY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-E3 # keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-E3.type" --- 3285,3295 ---- msgid "SUN4U-8006-DY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-DY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-DY.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-E3 # keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-E3.type"
*** 3301,3311 **** msgid "SUN4U-8006-E3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-E3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-E3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-FH # keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-FH.type" --- 3301,3311 ---- msgid "SUN4U-8006-E3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-E3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-E3.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-FH # keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-FH.type"
*** 3317,3327 **** msgid "SUN4U-8006-FH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-FH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-FH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-GD # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-GD.type" --- 3317,3327 ---- msgid "SUN4U-8006-FH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-FH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-FH.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-GD # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-GD.type"
*** 3333,3343 **** msgid "SUN4U-8006-GD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-GD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-GD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-HQ # keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-HQ.type" --- 3333,3343 ---- msgid "SUN4U-8006-GD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-GD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-GD.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-HQ # keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-HQ.type"
*** 3349,3359 **** msgid "SUN4U-8006-HQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-HQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-HQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-JC # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-JC.type" --- 3349,3359 ---- msgid "SUN4U-8006-HQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-HQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-HQ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-JC # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-JC.type"
*** 3365,3375 **** msgid "SUN4U-8006-JC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-JC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-JC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-KR # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-KR.type" --- 3365,3375 ---- msgid "SUN4U-8006-JC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-JC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-JC.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-KR # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-KR.type"
*** 3381,3391 **** msgid "SUN4U-8006-KR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-KR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-KR.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-L4 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-L4.type" --- 3381,3391 ---- msgid "SUN4U-8006-KR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-KR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-KR.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-L4 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-L4.type"
*** 3397,3407 **** msgid "SUN4U-8006-L4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-L4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-L4.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-MX # keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-MX.type" --- 3397,3407 ---- msgid "SUN4U-8006-L4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-L4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-L4.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-MX # keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-MX.type"
*** 3413,3423 **** msgid "SUN4U-8006-MX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-MX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-MX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-N2 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-N2.type" --- 3413,3423 ---- msgid "SUN4U-8006-MX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-MX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-MX.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-N2 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-N2.type"
*** 3429,3439 **** msgid "SUN4U-8006-N2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-N2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-N2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-PJ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-PJ.type" --- 3429,3439 ---- msgid "SUN4U-8006-N2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-N2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-N2.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-PJ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-PJ.type"
*** 3445,3455 **** msgid "SUN4U-8006-PJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-PJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-PJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-QE # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-QE.type" --- 3445,3455 ---- msgid "SUN4U-8006-PJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-PJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-PJ.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-QE # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-QE.type"
*** 3461,3471 **** msgid "SUN4U-8006-QE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-QE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-QE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-R5 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-R5.type" --- 3461,3471 ---- msgid "SUN4U-8006-QE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-QE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-QE.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-R5 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-R5.type"
*** 3477,3487 **** msgid "SUN4U-8006-R5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-R5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-R5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-SS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-SS.type" --- 3477,3487 ---- msgid "SUN4U-8006-R5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-R5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-R5.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-SS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-SS.type"
*** 3493,3503 **** msgid "SUN4U-8006-SS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-SS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-SS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-TA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-TA.type" --- 3493,3503 ---- msgid "SUN4U-8006-SS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-SS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-SS.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-TA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-TA.type"
*** 3509,3519 **** msgid "SUN4U-8006-TA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-TA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-TA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-UP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-UP.type" --- 3509,3519 ---- msgid "SUN4U-8006-TA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-TA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-TA.action" ! msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-UP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-UP.type"
*** 3525,3535 **** msgid "SUN4U-8006-UP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-UP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-UP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-VD # keys: fault.cpu.ultraSPARC-IIIiplus.dcache # msgid "SUN4U-8006-VD.type" --- 3525,3535 ---- msgid "SUN4U-8006-UP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-UP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-UP.action" ! msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-VD # keys: fault.cpu.ultraSPARC-IIIiplus.dcache # msgid "SUN4U-8006-VD.type"
*** 3701,3711 **** msgid "SUN4U-8007-65.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8007-65.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8007-65.action" ! msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUN4U-8007-7S # keys: fault.cpu.SPARC64-VI.chip # msgid "SUN4U-8007-7S.type" --- 3701,3711 ---- msgid "SUN4U-8007-65.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8007-65.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8007-65.action" ! msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." # # code: SUN4U-8007-7S # keys: fault.cpu.SPARC64-VI.chip # msgid "SUN4U-8007-7S.type"
*** 3765,3775 **** msgid "SUN4U-8007-AX.response" msgstr "One or more device instances may be disabled\n" msgid "SUN4U-8007-AX.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "SUN4U-8007-AX.action" ! msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for support.\n" # # code: SUN4U-8007-C2 # keys: fault.cpu.SPARC64-VII.chip # msgid "SUN4U-8007-C2.type" --- 3765,3775 ---- msgid "SUN4U-8007-AX.response" msgstr "One or more device instances may be disabled\n" msgid "SUN4U-8007-AX.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "SUN4U-8007-AX.action" ! msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact your illumos distribution team for support.\n" # # code: SUN4U-8007-C2 # keys: fault.cpu.SPARC64-VII.chip # msgid "SUN4U-8007-C2.type"
*** 3823,3833 **** msgid "SUN4U-8007-FQ.type" msgstr "Fault" msgid "SUN4U-8007-FQ.severity" msgstr "Minor" msgid "SUN4U-8007-FQ.description" ! msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-FQ.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-FQ.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-FQ.action" --- 3823,3833 ---- msgid "SUN4U-8007-FQ.type" msgstr "Fault" msgid "SUN4U-8007-FQ.severity" msgstr "Minor" msgid "SUN4U-8007-FQ.description" ! msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-FQ.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-FQ.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-FQ.action"
*** 3839,3849 **** msgid "SUN4U-8007-GC.type" msgstr "Fault" msgid "SUN4U-8007-GC.severity" msgstr "Minor" msgid "SUN4U-8007-GC.description" ! msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-GC.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-GC.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-GC.action" --- 3839,3849 ---- msgid "SUN4U-8007-GC.type" msgstr "Fault" msgid "SUN4U-8007-GC.severity" msgstr "Minor" msgid "SUN4U-8007-GC.description" ! msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-GC.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-GC.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-GC.action"
*** 3855,3865 **** msgid "SUN4U-8007-HH.type" msgstr "Fault" msgid "SUN4U-8007-HH.severity" msgstr "Minor" msgid "SUN4U-8007-HH.description" ! msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-HH.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-HH.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-HH.action" --- 3855,3865 ---- msgid "SUN4U-8007-HH.type" msgstr "Fault" msgid "SUN4U-8007-HH.severity" msgstr "Minor" msgid "SUN4U-8007-HH.description" ! msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-HH.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-HH.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-HH.action"
*** 3871,3881 **** msgid "SUN4U-8007-JD.type" msgstr "Fault" msgid "SUN4U-8007-JD.severity" msgstr "Minor" msgid "SUN4U-8007-JD.description" ! msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-JD.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-JD.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-JD.action" --- 3871,3881 ---- msgid "SUN4U-8007-JD.type" msgstr "Fault" msgid "SUN4U-8007-JD.severity" msgstr "Minor" msgid "SUN4U-8007-JD.description" ! msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-JD.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-JD.impact" msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n" msgid "SUN4U-8007-JD.action"