1 #
   2 # Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #
  24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # code: SUN4-8000-0Y
  28 # keys: fault.io.fire.asic
  29 #
  30 msgid "SUN4-8000-0Y.type"
  31 msgstr "Fault"
  32 msgid "SUN4-8000-0Y.severity"
  33 msgstr "Critical"
  34 msgid "SUN4-8000-0Y.description"
  35 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
  36 msgid "SUN4-8000-0Y.response"
  37 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
  38 msgid "SUN4-8000-0Y.impact"
  39 msgstr "Loss of services provided by the device instances associated with this fault"
  40 msgid "SUN4-8000-0Y.action"
  41 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
  42 #
  43 # code: SUN4-8000-13
  44 # keys: fault.io.ebus
  45 #
  46 msgid "SUN4-8000-13.type"
  47 msgstr "Fault"
  48 msgid "SUN4-8000-13.severity"
  49 msgstr "Critical"
  50 msgid "SUN4-8000-13.description"
  51 msgstr "A problem was detected in the Ebus.  Refer to %s for more information."
  52 msgid "SUN4-8000-13.response"
  53 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
  54 msgid "SUN4-8000-13.impact"
  55 msgstr "Loss of services provided by the device instances associated with this fault"
  56 msgid "SUN4-8000-13.action"
  57 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help illumos personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
  58 #
  59 # code: SUN4-8000-2H
  60 # keys: fault.io.datapath
  61 #
  62 msgid "SUN4-8000-2H.type"
  63 msgstr "Fault"
  64 msgid "SUN4-8000-2H.severity"
  65 msgstr "Critical"
  66 msgid "SUN4-8000-2H.description"
  67 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
  68 msgid "SUN4-8000-2H.response"
  69 msgstr "None"
  70 msgid "SUN4-8000-2H.impact"
  71 msgstr "None"
  72 msgid "SUN4-8000-2H.action"
  73 msgstr "None"
  74 #
  75 # code: SUN4-8000-3D
  76 # keys: fault.io.hbus
  77 #
  78 msgid "SUN4-8000-3D.type"
  79 msgstr "Fault"
  80 msgid "SUN4-8000-3D.severity"
  81 msgstr "Critical"
  82 msgid "SUN4-8000-3D.description"
  83 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
  84 msgid "SUN4-8000-3D.response"
  85 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
  86 msgid "SUN4-8000-3D.impact"
  87 msgstr "Loss of services provided by the device instances associated with this fault"
  88 msgid "SUN4-8000-3D.action"
  89 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
  90 #
  91 # code: SUN4-8000-4P
  92 # keys: fault.io.fire.pciex.device
  93 #
  94 msgid "SUN4-8000-4P.type"
  95 msgstr "Fault"
  96 msgid "SUN4-8000-4P.severity"
  97 msgstr "Critical"
  98 msgid "SUN4-8000-4P.description"
  99 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
 100 msgid "SUN4-8000-4P.response"
 101 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 102 msgid "SUN4-8000-4P.impact"
 103 msgstr "Loss of services provided by the device instances associated with this fault"
 104 msgid "SUN4-8000-4P.action"
 105 msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
 106 #
 107 # code: SUN4-8000-5A
 108 # keys: defect.io.fire.pciex.driver
 109 #
 110 msgid "SUN4-8000-5A.type"
 111 msgstr "Defect"
 112 msgid "SUN4-8000-5A.severity"
 113 msgstr "Critical"
 114 msgid "SUN4-8000-5A.description"
 115 msgstr "A problem was detected in the PCI-Express subsystem software.\n  Refer to %s for more information."
 116 msgid "SUN4-8000-5A.response"
 117 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 118 msgid "SUN4-8000-5A.impact"
 119 msgstr "Loss of services provided by the device instances associated with\nthis problem"
 120 msgid "SUN4-8000-5A.action"
 121 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
 122 #
 123 # code: SUN4-8000-6S
 124 # keys: fault.io.datapath fault.io.fire.asic
 125 #
 126 msgid "SUN4-8000-6S.type"
 127 msgstr "Fault"
 128 msgid "SUN4-8000-6S.severity"
 129 msgstr "Critical"
 130 msgid "SUN4-8000-6S.description"
 131 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
 132 msgid "SUN4-8000-6S.response"
 133 msgstr "None"
 134 msgid "SUN4-8000-6S.impact"
 135 msgstr "None"
 136 msgid "SUN4-8000-6S.action"
 137 msgstr "None"
 138 #
 139 # code: SUN4-8000-75
 140 # keys: fault.io.fire.asic fault.io.fire.pciex.device
 141 #
 142 msgid "SUN4-8000-75.type"
 143 msgstr "Fault"
 144 msgid "SUN4-8000-75.severity"
 145 msgstr "Critical"
 146 msgid "SUN4-8000-75.description"
 147 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
 148 msgid "SUN4-8000-75.response"
 149 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 150 msgid "SUN4-8000-75.impact"
 151 msgstr "Loss of services provided by the device instances associated with this fault"
 152 msgid "SUN4-8000-75.action"
 153 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
 154 #
 155 # code: SUN4-8000-8E
 156 # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
 157 #
 158 msgid "SUN4-8000-8E.type"
 159 msgstr "Defect"
 160 msgid "SUN4-8000-8E.severity"
 161 msgstr "Critical"
 162 msgid "SUN4-8000-8E.description"
 163 msgstr "A problem was detected in the PCI-Express subsystem software.  Refer to %s for more information."
 164 msgid "SUN4-8000-8E.response"
 165 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 166 msgid "SUN4-8000-8E.impact"
 167 msgstr "Loss of services provided by the device instances associated with this problem"
 168 msgid "SUN4-8000-8E.action"
 169 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
 170 #
 171 # code: SUN4-8000-9J
 172 # keys: fault.io.fire.pci.device fault.io.fire.pciex.device
 173 #
 174 msgid "SUN4-8000-9J.type"
 175 msgstr "Fault"
 176 msgid "SUN4-8000-9J.severity"
 177 msgstr "Critical"
 178 msgid "SUN4-8000-9J.description"
 179 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
 180 msgid "SUN4-8000-9J.response"
 181 msgstr "None"
 182 msgid "SUN4-8000-9J.impact"
 183 msgstr "None"
 184 msgid "SUN4-8000-9J.action"
 185 msgstr "None"
 186 #
 187 # code: SUN4-8000-A2
 188 # keys: fault.io.fire.pci.device
 189 #
 190 msgid "SUN4-8000-A2.type"
 191 msgstr "Fault"
 192 msgid "SUN4-8000-A2.severity"
 193 msgstr "Critical"
 194 msgid "SUN4-8000-A2.description"
 195 msgstr "A problem was detected in the PCI subsystem.\n  Refer to %s for more information."
 196 msgid "SUN4-8000-A2.response"
 197 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 198 msgid "SUN4-8000-A2.impact"
 199 msgstr "Loss of services provided by the device instances associated with this fault"
 200 msgid "SUN4-8000-A2.action"
 201 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
 202 #
 203 # code: SUN4-8000-CX
 204 # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
 205 #
 206 msgid "SUN4-8000-CX.type"
 207 msgstr "Fault"
 208 msgid "SUN4-8000-CX.severity"
 209 msgstr "Critical"
 210 msgid "SUN4-8000-CX.description"
 211 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
 212 msgid "SUN4-8000-CX.response"
 213 msgstr "None"
 214 msgid "SUN4-8000-CX.impact"
 215 msgstr "None"
 216 msgid "SUN4-8000-CX.action"
 217 msgstr "None"
 218 #
 219 # code: SUN4-8000-D4
 220 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
 221 #
 222 msgid "SUN4-8000-D4.type"
 223 msgstr "Fault"
 224 msgid "SUN4-8000-D4.severity"
 225 msgstr "Critical"
 226 msgid "SUN4-8000-D4.description"
 227 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
 228 msgid "SUN4-8000-D4.response"
 229 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 230 msgid "SUN4-8000-D4.impact"
 231 msgstr "Loss of services provided by the device instances associated with this fault"
 232 msgid "SUN4-8000-D4.action"
 233 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
 234 #
 235 # code: SUN4-8000-ER
 236 # keys: fault.io.fire.asic fault.io.fire.pci.device
 237 #
 238 msgid "SUN4-8000-ER.type"
 239 msgstr "Fault"
 240 msgid "SUN4-8000-ER.severity"
 241 msgstr "Critical"
 242 msgid "SUN4-8000-ER.description"
 243 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
 244 msgid "SUN4-8000-ER.response"
 245 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 246 msgid "SUN4-8000-ER.impact"
 247 msgstr "Loss of services provided by the device instances associated with this fault"
 248 msgid "SUN4-8000-ER.action"
 249 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
 250 #
 251 # code: SUN4-8000-FC
 252 # keys: fault.io.fire.hbus
 253 #
 254 msgid "SUN4-8000-FC.type"
 255 msgstr "Fault"
 256 msgid "SUN4-8000-FC.severity"
 257 msgstr "Major"
 258 msgid "SUN4-8000-FC.description"
 259 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
 260 msgid "SUN4-8000-FC.response"
 261 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
 262 msgid "SUN4-8000-FC.impact"
 263 msgstr "Loss of services provided by the device instances associated with this fault"
 264 msgid "SUN4-8000-FC.action"
 265 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
 266 #
 267 # code: SUN4-8000-GQ
 268 # keys: fault.io.fire.datapath fault.io.fire.hbus
 269 #
 270 msgid "SUN4-8000-GQ.type"
 271 msgstr "Fault"
 272 msgid "SUN4-8000-GQ.severity"
 273 msgstr "Critical"
 274 msgid "SUN4-8000-GQ.description"
 275 msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n  Refer to %s for more information."
 276 msgid "SUN4-8000-GQ.response"
 277 msgstr "One or more device instances may be disabled\n"
 278 msgid "SUN4-8000-GQ.impact"
 279 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 280 msgid "SUN4-8000-GQ.action"
 281 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 282 #
 283 # code: SUN4-8000-HD
 284 # keys: fault.io.fire.hb.sw-config
 285 #
 286 msgid "SUN4-8000-HD.type"
 287 msgstr "Fault"
 288 msgid "SUN4-8000-HD.severity"
 289 msgstr "Critical"
 290 msgid "SUN4-8000-HD.description"
 291 msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
 292 msgid "SUN4-8000-HD.response"
 293 msgstr "One or more device instances may be disabled\n"
 294 msgid "SUN4-8000-HD.impact"
 295 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 296 msgid "SUN4-8000-HD.action"
 297 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 298 #
 299 # code: SUN4-8000-JH
 300 # keys: fault.io.fire.dmc.sw-algorithm
 301 #
 302 msgid "SUN4-8000-JH.type"
 303 msgstr "Fault"
 304 msgid "SUN4-8000-JH.severity"
 305 msgstr "Critical"
 306 msgid "SUN4-8000-JH.description"
 307 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
 308 msgid "SUN4-8000-JH.response"
 309 msgstr "One or more device instances may be disabled\n"
 310 msgid "SUN4-8000-JH.impact"
 311 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 312 msgid "SUN4-8000-JH.action"
 313 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 314 #
 315 # code: SUN4-8000-K3
 316 # keys: fault.io.fire.dmc.sw-state
 317 #
 318 msgid "SUN4-8000-K3.type"
 319 msgstr "Fault"
 320 msgid "SUN4-8000-K3.severity"
 321 msgstr "Critical"
 322 msgid "SUN4-8000-K3.description"
 323 msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
 324 msgid "SUN4-8000-K3.response"
 325 msgstr "One or more device instances may be disabled\n"
 326 msgid "SUN4-8000-K3.impact"
 327 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 328 msgid "SUN4-8000-K3.action"
 329 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
 330 #
 331 # code: SUN4-8000-LY
 332 # keys: fault.io.fire.pec.sw-algorithm
 333 #
 334 msgid "SUN4-8000-LY.type"
 335 msgstr "Fault"
 336 msgid "SUN4-8000-LY.severity"
 337 msgstr "Critical"
 338 msgid "SUN4-8000-LY.description"
 339 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
 340 msgid "SUN4-8000-LY.response"
 341 msgstr "One or more device instances may be disabled\n"
 342 msgid "SUN4-8000-LY.impact"
 343 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 344 msgid "SUN4-8000-LY.action"
 345 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"