1 # 2 # Copyright 2007 Sun Microsystems, Inc. All rights reserved. 3 # Use is subject to license terms. 4 # 5 # CDDL HEADER START 6 # 7 # The contents of this file are subject to the terms of the 8 # Common Development and Distribution License (the "License"). 9 # You may not use this file except in compliance with the License. 10 # 11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12 # or http://www.opensolaris.org/os/licensing. 13 # See the License for the specific language governing permissions 14 # and limitations under the License. 15 # 16 # When distributing Covered Code, include this CDDL HEADER in each 17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18 # If applicable, add the following below this CDDL HEADER, with the 19 # fields enclosed by brackets "[]" replaced with your own identifying 20 # information: Portions Copyright [yyyy] [name of copyright owner] 21 # 22 # CDDL HEADER END 23 # 24 # DO NOT EDIT -- this file is generated by the Event Registry. 25 # 26 # 27 # code: SUN4-8000-0Y 28 # keys: fault.io.fire.asic 29 # 30 msgid "SUN4-8000-0Y.type" 31 msgstr "Fault" 32 msgid "SUN4-8000-0Y.severity" 33 msgstr "Critical" 34 msgid "SUN4-8000-0Y.description" 35 msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 36 msgid "SUN4-8000-0Y.response" 37 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 38 msgid "SUN4-8000-0Y.impact" 39 msgstr "Loss of services provided by the device instances associated with this fault" 40 msgid "SUN4-8000-0Y.action" 41 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 42 # 43 # code: SUN4-8000-13 44 # keys: fault.io.ebus 45 # 46 msgid "SUN4-8000-13.type" 47 msgstr "Fault" 48 msgid "SUN4-8000-13.severity" 49 msgstr "Critical" 50 msgid "SUN4-8000-13.description" 51 msgstr "A problem was detected in the Ebus. Refer to %s for more information." 52 msgid "SUN4-8000-13.response" 53 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 54 msgid "SUN4-8000-13.impact" 55 msgstr "Loss of services provided by the device instances associated with this fault" 56 msgid "SUN4-8000-13.action" 57 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help illumos personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n" 58 # 59 # code: SUN4-8000-2H 60 # keys: fault.io.datapath 61 # 62 msgid "SUN4-8000-2H.type" 63 msgstr "Fault" 64 msgid "SUN4-8000-2H.severity" 65 msgstr "Critical" 66 msgid "SUN4-8000-2H.description" 67 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." 68 msgid "SUN4-8000-2H.response" 69 msgstr "None" 70 msgid "SUN4-8000-2H.impact" 71 msgstr "None" 72 msgid "SUN4-8000-2H.action" 73 msgstr "None" 74 # 75 # code: SUN4-8000-3D 76 # keys: fault.io.hbus 77 # 78 msgid "SUN4-8000-3D.type" 79 msgstr "Fault" 80 msgid "SUN4-8000-3D.severity" 81 msgstr "Critical" 82 msgid "SUN4-8000-3D.description" 83 msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." 84 msgid "SUN4-8000-3D.response" 85 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 86 msgid "SUN4-8000-3D.impact" 87 msgstr "Loss of services provided by the device instances associated with this fault" 88 msgid "SUN4-8000-3D.action" 89 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 90 # 91 # code: SUN4-8000-4P 92 # keys: fault.io.fire.pciex.device 93 # 94 msgid "SUN4-8000-4P.type" 95 msgstr "Fault" 96 msgid "SUN4-8000-4P.severity" 97 msgstr "Critical" 98 msgid "SUN4-8000-4P.description" 99 msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 100 msgid "SUN4-8000-4P.response" 101 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 102 msgid "SUN4-8000-4P.impact" 103 msgstr "Loss of services provided by the device instances associated with this fault" 104 msgid "SUN4-8000-4P.action" 105 msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below." 106 # 107 # code: SUN4-8000-5A 108 # keys: defect.io.fire.pciex.driver 109 # 110 msgid "SUN4-8000-5A.type" 111 msgstr "Defect" 112 msgid "SUN4-8000-5A.severity" 113 msgstr "Critical" 114 msgid "SUN4-8000-5A.description" 115 msgstr "A problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." 116 msgid "SUN4-8000-5A.response" 117 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 118 msgid "SUN4-8000-5A.impact" 119 msgstr "Loss of services provided by the device instances associated with\nthis problem" 120 msgid "SUN4-8000-5A.action" 121 msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." 122 # 123 # code: SUN4-8000-6S 124 # keys: fault.io.datapath fault.io.fire.asic 125 # 126 msgid "SUN4-8000-6S.type" 127 msgstr "Fault" 128 msgid "SUN4-8000-6S.severity" 129 msgstr "Critical" 130 msgid "SUN4-8000-6S.description" 131 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." 132 msgid "SUN4-8000-6S.response" 133 msgstr "None" 134 msgid "SUN4-8000-6S.impact" 135 msgstr "None" 136 msgid "SUN4-8000-6S.action" 137 msgstr "None" 138 # 139 # code: SUN4-8000-75 140 # keys: fault.io.fire.asic fault.io.fire.pciex.device 141 # 142 msgid "SUN4-8000-75.type" 143 msgstr "Fault" 144 msgid "SUN4-8000-75.severity" 145 msgstr "Critical" 146 msgid "SUN4-8000-75.description" 147 msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 148 msgid "SUN4-8000-75.response" 149 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 150 msgid "SUN4-8000-75.impact" 151 msgstr "Loss of services provided by the device instances associated with this fault" 152 msgid "SUN4-8000-75.action" 153 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 154 # 155 # code: SUN4-8000-8E 156 # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver 157 # 158 msgid "SUN4-8000-8E.type" 159 msgstr "Defect" 160 msgid "SUN4-8000-8E.severity" 161 msgstr "Critical" 162 msgid "SUN4-8000-8E.description" 163 msgstr "A problem was detected in the PCI-Express subsystem software. Refer to %s for more information." 164 msgid "SUN4-8000-8E.response" 165 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 166 msgid "SUN4-8000-8E.impact" 167 msgstr "Loss of services provided by the device instances associated with this problem" 168 msgid "SUN4-8000-8E.action" 169 msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." 170 # 171 # code: SUN4-8000-9J 172 # keys: fault.io.fire.pci.device fault.io.fire.pciex.device 173 # 174 msgid "SUN4-8000-9J.type" 175 msgstr "Fault" 176 msgid "SUN4-8000-9J.severity" 177 msgstr "Critical" 178 msgid "SUN4-8000-9J.description" 179 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." 180 msgid "SUN4-8000-9J.response" 181 msgstr "None" 182 msgid "SUN4-8000-9J.impact" 183 msgstr "None" 184 msgid "SUN4-8000-9J.action" 185 msgstr "None" 186 # 187 # code: SUN4-8000-A2 188 # keys: fault.io.fire.pci.device 189 # 190 msgid "SUN4-8000-A2.type" 191 msgstr "Fault" 192 msgid "SUN4-8000-A2.severity" 193 msgstr "Critical" 194 msgid "SUN4-8000-A2.description" 195 msgstr "A problem was detected in the PCI subsystem.\n Refer to %s for more information." 196 msgid "SUN4-8000-A2.response" 197 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 198 msgid "SUN4-8000-A2.impact" 199 msgstr "Loss of services provided by the device instances associated with this fault" 200 msgid "SUN4-8000-A2.action" 201 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" 202 # 203 # code: SUN4-8000-CX 204 # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic 205 # 206 msgid "SUN4-8000-CX.type" 207 msgstr "Fault" 208 msgid "SUN4-8000-CX.severity" 209 msgstr "Critical" 210 msgid "SUN4-8000-CX.description" 211 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." 212 msgid "SUN4-8000-CX.response" 213 msgstr "None" 214 msgid "SUN4-8000-CX.impact" 215 msgstr "None" 216 msgid "SUN4-8000-CX.action" 217 msgstr "None" 218 # 219 # code: SUN4-8000-D4 220 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device 221 # 222 msgid "SUN4-8000-D4.type" 223 msgstr "Fault" 224 msgid "SUN4-8000-D4.severity" 225 msgstr "Critical" 226 msgid "SUN4-8000-D4.description" 227 msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 228 msgid "SUN4-8000-D4.response" 229 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 230 msgid "SUN4-8000-D4.impact" 231 msgstr "Loss of services provided by the device instances associated with this fault" 232 msgid "SUN4-8000-D4.action" 233 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 234 # 235 # code: SUN4-8000-ER 236 # keys: fault.io.fire.asic fault.io.fire.pci.device 237 # 238 msgid "SUN4-8000-ER.type" 239 msgstr "Fault" 240 msgid "SUN4-8000-ER.severity" 241 msgstr "Critical" 242 msgid "SUN4-8000-ER.description" 243 msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 244 msgid "SUN4-8000-ER.response" 245 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 246 msgid "SUN4-8000-ER.impact" 247 msgstr "Loss of services provided by the device instances associated with this fault" 248 msgid "SUN4-8000-ER.action" 249 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 250 # 251 # code: SUN4-8000-FC 252 # keys: fault.io.fire.hbus 253 # 254 msgid "SUN4-8000-FC.type" 255 msgstr "Fault" 256 msgid "SUN4-8000-FC.severity" 257 msgstr "Major" 258 msgid "SUN4-8000-FC.description" 259 msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." 260 msgid "SUN4-8000-FC.response" 261 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." 262 msgid "SUN4-8000-FC.impact" 263 msgstr "Loss of services provided by the device instances associated with this fault" 264 msgid "SUN4-8000-FC.action" 265 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 266 # 267 # code: SUN4-8000-GQ 268 # keys: fault.io.fire.datapath fault.io.fire.hbus 269 # 270 msgid "SUN4-8000-GQ.type" 271 msgstr "Fault" 272 msgid "SUN4-8000-GQ.severity" 273 msgstr "Critical" 274 msgid "SUN4-8000-GQ.description" 275 msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n Refer to %s for more information." 276 msgid "SUN4-8000-GQ.response" 277 msgstr "One or more device instances may be disabled\n" 278 msgid "SUN4-8000-GQ.impact" 279 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 280 msgid "SUN4-8000-GQ.action" 281 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" 282 # 283 # code: SUN4-8000-HD 284 # keys: fault.io.fire.hb.sw-config 285 # 286 msgid "SUN4-8000-HD.type" 287 msgstr "Fault" 288 msgid "SUN4-8000-HD.severity" 289 msgstr "Critical" 290 msgid "SUN4-8000-HD.description" 291 msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n Refer to %s for more information." 292 msgid "SUN4-8000-HD.response" 293 msgstr "One or more device instances may be disabled\n" 294 msgid "SUN4-8000-HD.impact" 295 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 296 msgid "SUN4-8000-HD.action" 297 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" 298 # 299 # code: SUN4-8000-JH 300 # keys: fault.io.fire.dmc.sw-algorithm 301 # 302 msgid "SUN4-8000-JH.type" 303 msgstr "Fault" 304 msgid "SUN4-8000-JH.severity" 305 msgstr "Critical" 306 msgid "SUN4-8000-JH.description" 307 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information." 308 msgid "SUN4-8000-JH.response" 309 msgstr "One or more device instances may be disabled\n" 310 msgid "SUN4-8000-JH.impact" 311 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 312 msgid "SUN4-8000-JH.action" 313 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" 314 # 315 # code: SUN4-8000-K3 316 # keys: fault.io.fire.dmc.sw-state 317 # 318 msgid "SUN4-8000-K3.type" 319 msgstr "Fault" 320 msgid "SUN4-8000-K3.severity" 321 msgstr "Critical" 322 msgid "SUN4-8000-K3.description" 323 msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n Refer to %s for more information." 324 msgid "SUN4-8000-K3.response" 325 msgstr "One or more device instances may be disabled\n" 326 msgid "SUN4-8000-K3.impact" 327 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 328 msgid "SUN4-8000-K3.action" 329 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" 330 # 331 # code: SUN4-8000-LY 332 # keys: fault.io.fire.pec.sw-algorithm 333 # 334 msgid "SUN4-8000-LY.type" 335 msgstr "Fault" 336 msgid "SUN4-8000-LY.severity" 337 msgstr "Critical" 338 msgid "SUN4-8000-LY.description" 339 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information." 340 msgid "SUN4-8000-LY.response" 341 msgstr "One or more device instances may be disabled\n" 342 msgid "SUN4-8000-LY.impact" 343 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 344 msgid "SUN4-8000-LY.action" 345 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"