1 # 2 # Copyright 2007 Sun Microsystems, Inc. All rights reserved. 3 # Use is subject to license terms. 4 # 5 # CDDL HEADER START 6 # 7 # The contents of this file are subject to the terms of the 8 # Common Development and Distribution License (the "License"). 9 # You may not use this file except in compliance with the License. 10 # 11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12 # or http://www.opensolaris.org/os/licensing. 13 # See the License for the specific language governing permissions 14 # and limitations under the License. 15 # 16 # When distributing Covered Code, include this CDDL HEADER in each 17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18 # If applicable, add the following below this CDDL HEADER, with the 19 # fields enclosed by brackets "[]" replaced with your own identifying 20 # information: Portions Copyright [yyyy] [name of copyright owner] 21 # 22 # CDDL HEADER END 23 # 24 #ident "%Z%%M% %I% %E% SMI" 25 # 26 # DO NOT EDIT -- this file is generated by the Event Registry. 27 # 28 # 29 # code: SUN4-8000-0Y 30 # keys: fault.io.fire.asic 31 # 32 msgid "SUN4-8000-0Y.type" 33 msgstr "Fault" 34 msgid "SUN4-8000-0Y.severity" 35 msgstr "Critical" 36 msgid "SUN4-8000-0Y.description" 37 msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 38 msgid "SUN4-8000-0Y.response" 39 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 40 msgid "SUN4-8000-0Y.impact" 41 msgstr "Loss of services provided by the device instances associated with this fault" 42 msgid "SUN4-8000-0Y.action" 43 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 44 # 45 # code: SUN4-8000-13 46 # keys: fault.io.ebus 47 # 48 msgid "SUN4-8000-13.type" 49 msgstr "Fault" 50 msgid "SUN4-8000-13.severity" 51 msgstr "Critical" 52 msgid "SUN4-8000-13.description" 53 msgstr "A problem was detected in the Ebus. Refer to %s for more information." 54 msgid "SUN4-8000-13.response" 55 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 56 msgid "SUN4-8000-13.impact" 57 msgstr "Loss of services provided by the device instances associated with this fault" 58 msgid "SUN4-8000-13.action" 59 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n" 60 # 61 # code: SUN4-8000-2H 62 # keys: fault.io.datapath 63 # 64 msgid "SUN4-8000-2H.type" 65 msgstr "Fault" 66 msgid "SUN4-8000-2H.severity" 67 msgstr "Critical" 68 msgid "SUN4-8000-2H.description" 69 msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 70 msgid "SUN4-8000-2H.response" 71 msgstr "None" 72 msgid "SUN4-8000-2H.impact" 73 msgstr "None" 74 msgid "SUN4-8000-2H.action" 75 msgstr "None" 76 # 77 # code: SUN4-8000-3D 78 # keys: fault.io.hbus 79 # 80 msgid "SUN4-8000-3D.type" 81 msgstr "Fault" 82 msgid "SUN4-8000-3D.severity" 83 msgstr "Critical" 84 msgid "SUN4-8000-3D.description" 85 msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." 86 msgid "SUN4-8000-3D.response" 87 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 88 msgid "SUN4-8000-3D.impact" 89 msgstr "Loss of services provided by the device instances associated with this fault" 90 msgid "SUN4-8000-3D.action" 91 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 92 # 93 # code: SUN4-8000-4P 94 # keys: fault.io.fire.pciex.device 95 # 96 msgid "SUN4-8000-4P.type" 97 msgstr "Fault" 98 msgid "SUN4-8000-4P.severity" 99 msgstr "Critical" 100 msgid "SUN4-8000-4P.description" 101 msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 102 msgid "SUN4-8000-4P.response" 103 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 104 msgid "SUN4-8000-4P.impact" 105 msgstr "Loss of services provided by the device instances associated with this fault" 106 msgid "SUN4-8000-4P.action" 107 msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below." 108 # 109 # code: SUN4-8000-5A 110 # keys: defect.io.fire.pciex.driver 111 # 112 msgid "SUN4-8000-5A.type" 113 msgstr "Defect" 114 msgid "SUN4-8000-5A.severity" 115 msgstr "Critical" 116 msgid "SUN4-8000-5A.description" 117 msgstr "A problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." 118 msgid "SUN4-8000-5A.response" 119 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 120 msgid "SUN4-8000-5A.impact" 121 msgstr "Loss of services provided by the device instances associated with\nthis problem" 122 msgid "SUN4-8000-5A.action" 123 msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 124 # 125 # code: SUN4-8000-6S 126 # keys: fault.io.datapath fault.io.fire.asic 127 # 128 msgid "SUN4-8000-6S.type" 129 msgstr "Fault" 130 msgid "SUN4-8000-6S.severity" 131 msgstr "Critical" 132 msgid "SUN4-8000-6S.description" 133 msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 134 msgid "SUN4-8000-6S.response" 135 msgstr "None" 136 msgid "SUN4-8000-6S.impact" 137 msgstr "None" 138 msgid "SUN4-8000-6S.action" 139 msgstr "None" 140 # 141 # code: SUN4-8000-75 142 # keys: fault.io.fire.asic fault.io.fire.pciex.device 143 # 144 msgid "SUN4-8000-75.type" 145 msgstr "Fault" 146 msgid "SUN4-8000-75.severity" 147 msgstr "Critical" 148 msgid "SUN4-8000-75.description" 149 msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 150 msgid "SUN4-8000-75.response" 151 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 152 msgid "SUN4-8000-75.impact" 153 msgstr "Loss of services provided by the device instances associated with this fault" 154 msgid "SUN4-8000-75.action" 155 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 156 # 157 # code: SUN4-8000-8E 158 # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver 159 # 160 msgid "SUN4-8000-8E.type" 161 msgstr "Defect" 162 msgid "SUN4-8000-8E.severity" 163 msgstr "Critical" 164 msgid "SUN4-8000-8E.description" 165 msgstr "A problem was detected in the PCI-Express subsystem software. Refer to %s for more information." 166 msgid "SUN4-8000-8E.response" 167 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 168 msgid "SUN4-8000-8E.impact" 169 msgstr "Loss of services provided by the device instances associated with this problem" 170 msgid "SUN4-8000-8E.action" 171 msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 172 # 173 # code: SUN4-8000-9J 174 # keys: fault.io.fire.pci.device fault.io.fire.pciex.device 175 # 176 msgid "SUN4-8000-9J.type" 177 msgstr "Fault" 178 msgid "SUN4-8000-9J.severity" 179 msgstr "Critical" 180 msgid "SUN4-8000-9J.description" 181 msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 182 msgid "SUN4-8000-9J.response" 183 msgstr "None" 184 msgid "SUN4-8000-9J.impact" 185 msgstr "None" 186 msgid "SUN4-8000-9J.action" 187 msgstr "None" 188 # 189 # code: SUN4-8000-A2 190 # keys: fault.io.fire.pci.device 191 # 192 msgid "SUN4-8000-A2.type" 193 msgstr "Fault" 194 msgid "SUN4-8000-A2.severity" 195 msgstr "Critical" 196 msgid "SUN4-8000-A2.description" 197 msgstr "A problem was detected in the PCI subsystem.\n Refer to %s for more information." 198 msgid "SUN4-8000-A2.response" 199 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 200 msgid "SUN4-8000-A2.impact" 201 msgstr "Loss of services provided by the device instances associated with this fault" 202 msgid "SUN4-8000-A2.action" 203 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 204 # 205 # code: SUN4-8000-CX 206 # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic 207 # 208 msgid "SUN4-8000-CX.type" 209 msgstr "Fault" 210 msgid "SUN4-8000-CX.severity" 211 msgstr "Critical" 212 msgid "SUN4-8000-CX.description" 213 msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 214 msgid "SUN4-8000-CX.response" 215 msgstr "None" 216 msgid "SUN4-8000-CX.impact" 217 msgstr "None" 218 msgid "SUN4-8000-CX.action" 219 msgstr "None" 220 # 221 # code: SUN4-8000-D4 222 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device 223 # 224 msgid "SUN4-8000-D4.type" 225 msgstr "Fault" 226 msgid "SUN4-8000-D4.severity" 227 msgstr "Critical" 228 msgid "SUN4-8000-D4.description" 229 msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 230 msgid "SUN4-8000-D4.response" 231 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 232 msgid "SUN4-8000-D4.impact" 233 msgstr "Loss of services provided by the device instances associated with this fault" 234 msgid "SUN4-8000-D4.action" 235 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 236 # 237 # code: SUN4-8000-ER 238 # keys: fault.io.fire.asic fault.io.fire.pci.device 239 # 240 msgid "SUN4-8000-ER.type" 241 msgstr "Fault" 242 msgid "SUN4-8000-ER.severity" 243 msgstr "Critical" 244 msgid "SUN4-8000-ER.description" 245 msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 246 msgid "SUN4-8000-ER.response" 247 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 248 msgid "SUN4-8000-ER.impact" 249 msgstr "Loss of services provided by the device instances associated with this fault" 250 msgid "SUN4-8000-ER.action" 251 msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 252 # 253 # code: SUN4-8000-FC 254 # keys: fault.io.fire.hbus 255 # 256 msgid "SUN4-8000-FC.type" 257 msgstr "Fault" 258 msgid "SUN4-8000-FC.severity" 259 msgstr "Major" 260 msgid "SUN4-8000-FC.description" 261 msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." 262 msgid "SUN4-8000-FC.response" 263 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 264 msgid "SUN4-8000-FC.impact" 265 msgstr "Loss of services provided by the device instances associated with this fault" 266 msgid "SUN4-8000-FC.action" 267 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 268 # 269 # code: SUN4-8000-GQ 270 # keys: fault.io.fire.datapath fault.io.fire.hbus 271 # 272 msgid "SUN4-8000-GQ.type" 273 msgstr "Fault" 274 msgid "SUN4-8000-GQ.severity" 275 msgstr "Critical" 276 msgid "SUN4-8000-GQ.description" 277 msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n Refer to %s for more information." 278 msgid "SUN4-8000-GQ.response" 279 msgstr "One or more device instances may be disabled\n" 280 msgid "SUN4-8000-GQ.impact" 281 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 282 msgid "SUN4-8000-GQ.action" 283 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 284 # 285 # code: SUN4-8000-HD 286 # keys: fault.io.fire.hb.sw-config 287 # 288 msgid "SUN4-8000-HD.type" 289 msgstr "Fault" 290 msgid "SUN4-8000-HD.severity" 291 msgstr "Critical" 292 msgid "SUN4-8000-HD.description" 293 msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n Refer to %s for more information." 294 msgid "SUN4-8000-HD.response" 295 msgstr "One or more device instances may be disabled\n" 296 msgid "SUN4-8000-HD.impact" 297 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 298 msgid "SUN4-8000-HD.action" 299 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 300 # 301 # code: SUN4-8000-JH 302 # keys: fault.io.fire.dmc.sw-algorithm 303 # 304 msgid "SUN4-8000-JH.type" 305 msgstr "Fault" 306 msgid "SUN4-8000-JH.severity" 307 msgstr "Critical" 308 msgid "SUN4-8000-JH.description" 309 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information." 310 msgid "SUN4-8000-JH.response" 311 msgstr "One or more device instances may be disabled\n" 312 msgid "SUN4-8000-JH.impact" 313 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 314 msgid "SUN4-8000-JH.action" 315 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 316 # 317 # code: SUN4-8000-K3 318 # keys: fault.io.fire.dmc.sw-state 319 # 320 msgid "SUN4-8000-K3.type" 321 msgstr "Fault" 322 msgid "SUN4-8000-K3.severity" 323 msgstr "Critical" 324 msgid "SUN4-8000-K3.description" 325 msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n Refer to %s for more information." 326 msgid "SUN4-8000-K3.response" 327 msgstr "One or more device instances may be disabled\n" 328 msgid "SUN4-8000-K3.impact" 329 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 330 msgid "SUN4-8000-K3.action" 331 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 332 # 333 # code: SUN4-8000-LY 334 # keys: fault.io.fire.pec.sw-algorithm 335 # 336 msgid "SUN4-8000-LY.type" 337 msgstr "Fault" 338 msgid "SUN4-8000-LY.severity" 339 msgstr "Critical" 340 msgid "SUN4-8000-LY.description" 341 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information." 342 msgid "SUN4-8000-LY.response" 343 msgstr "One or more device instances may be disabled\n" 344 msgid "SUN4-8000-LY.impact" 345 msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 346 msgid "SUN4-8000-LY.action" 347 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"