1 #
   2 # Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #
  24 #ident  "%Z%%M% %I%     %E% SMI"
  25 #
  26 # DO NOT EDIT -- this file is generated by the Event Registry.
  27 #
  28 #
  29 # code: SUN4-8000-0Y
  30 # keys: fault.io.fire.asic
  31 #
  32 msgid "SUN4-8000-0Y.type"
  33 msgstr "Fault"
  34 msgid "SUN4-8000-0Y.severity"
  35 msgstr "Critical"
  36 msgid "SUN4-8000-0Y.description"
  37 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
  38 msgid "SUN4-8000-0Y.response"
  39 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
  40 msgid "SUN4-8000-0Y.impact"
  41 msgstr "Loss of services provided by the device instances associated with this fault"
  42 msgid "SUN4-8000-0Y.action"
  43 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
  44 #
  45 # code: SUN4-8000-13
  46 # keys: fault.io.ebus
  47 #
  48 msgid "SUN4-8000-13.type"
  49 msgstr "Fault"
  50 msgid "SUN4-8000-13.severity"
  51 msgstr "Critical"
  52 msgid "SUN4-8000-13.description"
  53 msgstr "A problem was detected in the Ebus.  Refer to %s for more information."
  54 msgid "SUN4-8000-13.response"
  55 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
  56 msgid "SUN4-8000-13.impact"
  57 msgstr "Loss of services provided by the device instances associated with this fault"
  58 msgid "SUN4-8000-13.action"
  59 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
  60 #
  61 # code: SUN4-8000-2H
  62 # keys: fault.io.datapath
  63 #
  64 msgid "SUN4-8000-2H.type"
  65 msgstr "Fault"
  66 msgid "SUN4-8000-2H.severity"
  67 msgstr "Critical"
  68 msgid "SUN4-8000-2H.description"
  69 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
  70 msgid "SUN4-8000-2H.response"
  71 msgstr "None"
  72 msgid "SUN4-8000-2H.impact"
  73 msgstr "None"
  74 msgid "SUN4-8000-2H.action"
  75 msgstr "None"
  76 #
  77 # code: SUN4-8000-3D
  78 # keys: fault.io.hbus
  79 #
  80 msgid "SUN4-8000-3D.type"
  81 msgstr "Fault"
  82 msgid "SUN4-8000-3D.severity"
  83 msgstr "Critical"
  84 msgid "SUN4-8000-3D.description"
  85 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
  86 msgid "SUN4-8000-3D.response"
  87 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
  88 msgid "SUN4-8000-3D.impact"
  89 msgstr "Loss of services provided by the device instances associated with this fault"
  90 msgid "SUN4-8000-3D.action"
  91 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
  92 #
  93 # code: SUN4-8000-4P
  94 # keys: fault.io.fire.pciex.device
  95 #
  96 msgid "SUN4-8000-4P.type"
  97 msgstr "Fault"
  98 msgid "SUN4-8000-4P.severity"
  99 msgstr "Critical"
 100 msgid "SUN4-8000-4P.description"
 101 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
 102 msgid "SUN4-8000-4P.response"
 103 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 104 msgid "SUN4-8000-4P.impact"
 105 msgstr "Loss of services provided by the device instances associated with this fault"
 106 msgid "SUN4-8000-4P.action"
 107 msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
 108 #
 109 # code: SUN4-8000-5A
 110 # keys: defect.io.fire.pciex.driver
 111 #
 112 msgid "SUN4-8000-5A.type"
 113 msgstr "Defect"
 114 msgid "SUN4-8000-5A.severity"
 115 msgstr "Critical"
 116 msgid "SUN4-8000-5A.description"
 117 msgstr "A problem was detected in the PCI-Express subsystem software.\n  Refer to %s for more information."
 118 msgid "SUN4-8000-5A.response"
 119 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 120 msgid "SUN4-8000-5A.impact"
 121 msgstr "Loss of services provided by the device instances associated with\nthis problem"
 122 msgid "SUN4-8000-5A.action"
 123 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
 124 #
 125 # code: SUN4-8000-6S
 126 # keys: fault.io.datapath fault.io.fire.asic
 127 #
 128 msgid "SUN4-8000-6S.type"
 129 msgstr "Fault"
 130 msgid "SUN4-8000-6S.severity"
 131 msgstr "Critical"
 132 msgid "SUN4-8000-6S.description"
 133 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
 134 msgid "SUN4-8000-6S.response"
 135 msgstr "None"
 136 msgid "SUN4-8000-6S.impact"
 137 msgstr "None"
 138 msgid "SUN4-8000-6S.action"
 139 msgstr "None"
 140 #
 141 # code: SUN4-8000-75
 142 # keys: fault.io.fire.asic fault.io.fire.pciex.device
 143 #
 144 msgid "SUN4-8000-75.type"
 145 msgstr "Fault"
 146 msgid "SUN4-8000-75.severity"
 147 msgstr "Critical"
 148 msgid "SUN4-8000-75.description"
 149 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
 150 msgid "SUN4-8000-75.response"
 151 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 152 msgid "SUN4-8000-75.impact"
 153 msgstr "Loss of services provided by the device instances associated with this fault"
 154 msgid "SUN4-8000-75.action"
 155 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
 156 #
 157 # code: SUN4-8000-8E
 158 # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
 159 #
 160 msgid "SUN4-8000-8E.type"
 161 msgstr "Defect"
 162 msgid "SUN4-8000-8E.severity"
 163 msgstr "Critical"
 164 msgid "SUN4-8000-8E.description"
 165 msgstr "A problem was detected in the PCI-Express subsystem software.  Refer to %s for more information."
 166 msgid "SUN4-8000-8E.response"
 167 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 168 msgid "SUN4-8000-8E.impact"
 169 msgstr "Loss of services provided by the device instances associated with this problem"
 170 msgid "SUN4-8000-8E.action"
 171 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
 172 #
 173 # code: SUN4-8000-9J
 174 # keys: fault.io.fire.pci.device fault.io.fire.pciex.device
 175 #
 176 msgid "SUN4-8000-9J.type"
 177 msgstr "Fault"
 178 msgid "SUN4-8000-9J.severity"
 179 msgstr "Critical"
 180 msgid "SUN4-8000-9J.description"
 181 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
 182 msgid "SUN4-8000-9J.response"
 183 msgstr "None"
 184 msgid "SUN4-8000-9J.impact"
 185 msgstr "None"
 186 msgid "SUN4-8000-9J.action"
 187 msgstr "None"
 188 #
 189 # code: SUN4-8000-A2
 190 # keys: fault.io.fire.pci.device
 191 #
 192 msgid "SUN4-8000-A2.type"
 193 msgstr "Fault"
 194 msgid "SUN4-8000-A2.severity"
 195 msgstr "Critical"
 196 msgid "SUN4-8000-A2.description"
 197 msgstr "A problem was detected in the PCI subsystem.\n  Refer to %s for more information."
 198 msgid "SUN4-8000-A2.response"
 199 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 200 msgid "SUN4-8000-A2.impact"
 201 msgstr "Loss of services provided by the device instances associated with this fault"
 202 msgid "SUN4-8000-A2.action"
 203 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
 204 #
 205 # code: SUN4-8000-CX
 206 # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
 207 #
 208 msgid "SUN4-8000-CX.type"
 209 msgstr "Fault"
 210 msgid "SUN4-8000-CX.severity"
 211 msgstr "Critical"
 212 msgid "SUN4-8000-CX.description"
 213 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
 214 msgid "SUN4-8000-CX.response"
 215 msgstr "None"
 216 msgid "SUN4-8000-CX.impact"
 217 msgstr "None"
 218 msgid "SUN4-8000-CX.action"
 219 msgstr "None"
 220 #
 221 # code: SUN4-8000-D4
 222 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
 223 #
 224 msgid "SUN4-8000-D4.type"
 225 msgstr "Fault"
 226 msgid "SUN4-8000-D4.severity"
 227 msgstr "Critical"
 228 msgid "SUN4-8000-D4.description"
 229 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
 230 msgid "SUN4-8000-D4.response"
 231 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 232 msgid "SUN4-8000-D4.impact"
 233 msgstr "Loss of services provided by the device instances associated with this fault"
 234 msgid "SUN4-8000-D4.action"
 235 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
 236 #
 237 # code: SUN4-8000-ER
 238 # keys: fault.io.fire.asic fault.io.fire.pci.device
 239 #
 240 msgid "SUN4-8000-ER.type"
 241 msgstr "Fault"
 242 msgid "SUN4-8000-ER.severity"
 243 msgstr "Critical"
 244 msgid "SUN4-8000-ER.description"
 245 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
 246 msgid "SUN4-8000-ER.response"
 247 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 248 msgid "SUN4-8000-ER.impact"
 249 msgstr "Loss of services provided by the device instances associated with this fault"
 250 msgid "SUN4-8000-ER.action"
 251 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
 252 #
 253 # code: SUN4-8000-FC
 254 # keys: fault.io.fire.hbus
 255 #
 256 msgid "SUN4-8000-FC.type"
 257 msgstr "Fault"
 258 msgid "SUN4-8000-FC.severity"
 259 msgstr "Major"
 260 msgid "SUN4-8000-FC.description"
 261 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
 262 msgid "SUN4-8000-FC.response"
 263 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
 264 msgid "SUN4-8000-FC.impact"
 265 msgstr "Loss of services provided by the device instances associated with this fault"
 266 msgid "SUN4-8000-FC.action"
 267 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
 268 #
 269 # code: SUN4-8000-GQ
 270 # keys: fault.io.fire.datapath fault.io.fire.hbus
 271 #
 272 msgid "SUN4-8000-GQ.type"
 273 msgstr "Fault"
 274 msgid "SUN4-8000-GQ.severity"
 275 msgstr "Critical"
 276 msgid "SUN4-8000-GQ.description"
 277 msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n  Refer to %s for more information."
 278 msgid "SUN4-8000-GQ.response"
 279 msgstr "One or more device instances may be disabled\n"
 280 msgid "SUN4-8000-GQ.impact"
 281 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 282 msgid "SUN4-8000-GQ.action"
 283 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 284 #
 285 # code: SUN4-8000-HD
 286 # keys: fault.io.fire.hb.sw-config
 287 #
 288 msgid "SUN4-8000-HD.type"
 289 msgstr "Fault"
 290 msgid "SUN4-8000-HD.severity"
 291 msgstr "Critical"
 292 msgid "SUN4-8000-HD.description"
 293 msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
 294 msgid "SUN4-8000-HD.response"
 295 msgstr "One or more device instances may be disabled\n"
 296 msgid "SUN4-8000-HD.impact"
 297 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 298 msgid "SUN4-8000-HD.action"
 299 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 300 #
 301 # code: SUN4-8000-JH
 302 # keys: fault.io.fire.dmc.sw-algorithm
 303 #
 304 msgid "SUN4-8000-JH.type"
 305 msgstr "Fault"
 306 msgid "SUN4-8000-JH.severity"
 307 msgstr "Critical"
 308 msgid "SUN4-8000-JH.description"
 309 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
 310 msgid "SUN4-8000-JH.response"
 311 msgstr "One or more device instances may be disabled\n"
 312 msgid "SUN4-8000-JH.impact"
 313 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 314 msgid "SUN4-8000-JH.action"
 315 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 316 #
 317 # code: SUN4-8000-K3
 318 # keys: fault.io.fire.dmc.sw-state
 319 #
 320 msgid "SUN4-8000-K3.type"
 321 msgstr "Fault"
 322 msgid "SUN4-8000-K3.severity"
 323 msgstr "Critical"
 324 msgid "SUN4-8000-K3.description"
 325 msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
 326 msgid "SUN4-8000-K3.response"
 327 msgstr "One or more device instances may be disabled\n"
 328 msgid "SUN4-8000-K3.impact"
 329 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 330 msgid "SUN4-8000-K3.action"
 331 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
 332 #
 333 # code: SUN4-8000-LY
 334 # keys: fault.io.fire.pec.sw-algorithm
 335 #
 336 msgid "SUN4-8000-LY.type"
 337 msgstr "Fault"
 338 msgid "SUN4-8000-LY.severity"
 339 msgstr "Critical"
 340 msgid "SUN4-8000-LY.description"
 341 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
 342 msgid "SUN4-8000-LY.response"
 343 msgstr "One or more device instances may be disabled\n"
 344 msgid "SUN4-8000-LY.impact"
 345 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
 346 msgid "SUN4-8000-LY.action"
 347 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"