Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>


   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #
  24 #ident  "%Z%%M% %I%     %E% SMI"
  25 #
  26 # DO NOT EDIT -- this file is generated by the Event Registry.
  27 #
  28 #
  29 # code: SCF-8000-1D
  30 # keys: fault.chassis.SPARC-Enterprise.if.fe-asic-clk
  31 #
  32 msgid "SCF-8000-1D.type"
  33 msgstr "Fault"
  34 msgid "SCF-8000-1D.severity"
  35 msgstr "Critical"
  36 msgid "SCF-8000-1D.description"
  37 msgstr "A fatal clock distribution error was detected by an ASIC or a CPU chip.\n  Refer to %s for more information."
  38 msgid "SCF-8000-1D.response"
  39 msgstr "An attempt will be made to deconfigure the faulty components after one or more domains are reset.\n"
  40 msgid "SCF-8000-1D.impact"
  41 msgstr "One or more domains will be reset. Please consult the detail section of the knowledge article for \nadditional information.\n"
  42 msgid "SCF-8000-1D.action"
  43 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
  44 #
  45 # code: SCF-8000-2Y


 465 msgstr "Fault"
 466 msgid "SCF-8001-AA.severity"
 467 msgstr "Major"
 468 msgid "SCF-8001-AA.description"
 469 msgstr "The number of correctable errors associated with a FLP chip has exceeded an\nacceptable threshold.\n  Refer to %s for more information."
 470 msgid "SCF-8001-AA.response"
 471 msgstr "The IO Channel associated with the FLP chip will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
 472 msgid "SCF-8001-AA.impact"
 473 msgstr "No immediate impact. The IO Channel associated with the FLP chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is \nperformed.\n"
 474 msgid "SCF-8001-AA.action"
 475 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
 476 #
 477 # code: SCF-8001-KC
 478 # keys: upset.chassis.SPARC-Enterprise.io.disk.boot
 479 #
 480 msgid "SCF-8001-KC.type"
 481 msgstr "upset"
 482 msgid "SCF-8001-KC.severity"
 483 msgstr "Critical"
 484 msgid "SCF-8001-KC.description"
 485 msgstr "Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.\n  Refer to %s for more information."
 486 msgid "SCF-8001-KC.response"
 487 msgstr "Nothing is deconfigured.\n"
 488 msgid "SCF-8001-KC.impact"
 489 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 490 msgid "SCF-8001-KC.action"
 491 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 492 #
 493 # code: SCF-8001-LQ
 494 # keys: fault.chassis.SPARC-Enterprise.if.fe-ioc-flp
 495 #
 496 msgid "SCF-8001-LQ.type"
 497 msgstr "Fault"
 498 msgid "SCF-8001-LQ.severity"
 499 msgstr "Critical"
 500 msgid "SCF-8001-LQ.description"
 501 msgstr "A fatal error occurred on the interface between an IOC chip and a FLP chip.\n  Refer to %s for more information."
 502 msgid "SCF-8001-LQ.response"
 503 msgstr "The IO Channel associated with the FLP chip will be deconfigured after the domain\nusing the IO Channel is reset.\n"
 504 msgid "SCF-8001-LQ.impact"
 505 msgstr "The domain using the IO Channel associated with the FLP chip is reset. The IO Channel will\ndeconfigured after the domain is reset.\n"


 833 msgstr "Fault"
 834 msgid "SCF-8002-8D.severity"
 835 msgstr "Major"
 836 msgid "SCF-8002-8D.description"
 837 msgstr "The number of correctable errors within a IOC Chip has exceeded an acceptable threshold. This fault\naffects a single IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
 838 msgid "SCF-8002-8D.response"
 839 msgstr "The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is power cycled or after \nthe domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
 840 msgid "SCF-8002-8D.impact"
 841 msgstr "No immediate impact. The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is \npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
 842 msgid "SCF-8002-8D.action"
 843 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
 844 #
 845 # code: SCF-8002-9H
 846 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.boot
 847 #
 848 msgid "SCF-8002-9H.type"
 849 msgstr "Upset"
 850 msgid "SCF-8002-9H.severity"
 851 msgstr "Critical"
 852 msgid "SCF-8002-9H.description"
 853 msgstr "Failure to boot Solaris on a domain using a device on an IO Channel.\n  Refer to %s for more information."
 854 msgid "SCF-8002-9H.response"
 855 msgstr "Nothing is deconfigured.\n"
 856 msgid "SCF-8002-9H.impact"
 857 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 858 msgid "SCF-8002-9H.action"
 859 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
 860 #
 861 # code: SCF-8002-A3
 862 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.boot
 863 #
 864 msgid "SCF-8002-A3.type"
 865 msgstr "Upset"
 866 msgid "SCF-8002-A3.severity"
 867 msgstr "Critical"
 868 msgid "SCF-8002-A3.description"
 869 msgstr "Failure to boot Solaris on a domain using a device on IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
 870 msgid "SCF-8002-A3.response"
 871 msgstr "Nothing is deconfigured.\n"
 872 msgid "SCF-8002-A3.impact"
 873 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 874 msgid "SCF-8002-A3.action"
 875 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
 876 #
 877 # code: SCF-8002-CY
 878 # keys: upset.chassis.SPARC-Enterprise.io.pci.gbe.boot
 879 #
 880 msgid "SCF-8002-CY.type"
 881 msgstr "Upset"
 882 msgid "SCF-8002-CY.severity"
 883 msgstr "Critical"
 884 msgid "SCF-8002-CY.description"
 885 msgstr "Failure to boot Solaris on a domain via GbE.\n  Refer to %s for more information."
 886 msgid "SCF-8002-CY.response"
 887 msgstr "Nothing is deconfigured.\n"
 888 msgid "SCF-8002-CY.impact"
 889 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 890 msgid "SCF-8002-CY.action"
 891 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 892 #
 893 # code: SCF-8002-D5
 894 # keys: upset.chassis.SPARC-Enterprise.io.pci.card.boot
 895 #
 896 msgid "SCF-8002-D5.type"
 897 msgstr "Upset"
 898 msgid "SCF-8002-D5.severity"
 899 msgstr "Critical"
 900 msgid "SCF-8002-D5.description"
 901 msgstr "Failure to boot Solaris on a domain using a device in a PCI-X slot.\n  Refer to %s for more information."
 902 msgid "SCF-8002-D5.response"
 903 msgstr "Nothing is deconfigured.\n"
 904 msgid "SCF-8002-D5.impact"
 905 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt\n"
 906 msgid "SCF-8002-D5.action"
 907 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 908 #
 909 # code: SCF-8002-ES
 910 # keys: upset.chassis.SPARC-Enterprise.io.pciex.card.boot
 911 #
 912 msgid "SCF-8002-ES.type"
 913 msgstr "Upset"
 914 msgid "SCF-8002-ES.severity"
 915 msgstr "Critical"
 916 msgid "SCF-8002-ES.description"
 917 msgstr "Failure to boot Solaris on a domain using a device in a PCI-Express slot.\n  Refer to %s for more information."
 918 msgid "SCF-8002-ES.response"
 919 msgstr "Nothing is deconfigured.\n"
 920 msgid "SCF-8002-ES.impact"
 921 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 922 msgid "SCF-8002-ES.action"
 923 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 924 #
 925 # code: SCF-8002-FA
 926 # keys: upset.chassis.SPARC-Enterprise.io.pciex.bridge.boot
 927 #
 928 msgid "SCF-8002-FA.type"
 929 msgstr "Upset"
 930 msgid "SCF-8002-FA.severity"
 931 msgstr "Critical"
 932 msgid "SCF-8002-FA.description"
 933 msgstr "Failure to boot Solaris on a domain using a device behind a PCI-Express/PCI-X \nbridge chip. This includes the PCI-X slot and internal I/O on an IOU (if the\nPCI-Express/PCI-X bridge is located on an IOU or IOUA) and the PCI-X slots of\nan I/O Boat (if the PCI-Express/PCI-X bridge is located on an I/O Boat).\n  Refer to %s for more information."
 934 msgid "SCF-8002-FA.response"
 935 msgstr "Nothing is deconfigured.\n"
 936 msgid "SCF-8002-FA.impact"
 937 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 938 msgid "SCF-8002-FA.action"
 939 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 940 #
 941 # code: SCF-8002-GP
 942 # keys: upset.chassis.SPARC-Enterprise.io.pciex.switch.boot
 943 #
 944 msgid "SCF-8002-GP.type"
 945 msgstr "upset"
 946 msgid "SCF-8002-GP.severity"
 947 msgstr "Critical"
 948 msgid "SCF-8002-GP.description"
 949 msgstr "Failure to boot Solaris on a domain using a device behind a PCI-Express switch chip.\nThis includes PCI-X slot and internal I/O devices (if the PCI-Express switch chip \nis located on an IOU), and the PCI-Express slots and PCI-X slots on an I/O Boat\n(if the PCI-Express switch chip is located on an I/O Boat).\n  Refer to %s for more information."
 950 msgid "SCF-8002-GP.response"
 951 msgstr "Nothing is deconfigured.\n"
 952 msgid "SCF-8002-GP.impact"
 953 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 954 msgid "SCF-8002-GP.action"
 955 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 956 #
 957 # code: SCF-8002-HE
 958 # keys: upset.chassis.SPARC-Enterprise.io.pci.sas.boot
 959 #
 960 msgid "SCF-8002-HE.type"
 961 msgstr "Upset"
 962 msgid "SCF-8002-HE.severity"
 963 msgstr "Critical"
 964 msgid "SCF-8002-HE.description"
 965 msgstr "Failure to boot Solaris on a domain using an internal SAS (Serial Attached\nSCSI) device. This includes the internal hard drives and the internal DVD drives\nand the internal tape drives.\n  Refer to %s for more information."
 966 msgid "SCF-8002-HE.response"
 967 msgstr "Nothing is deconfigured.\n"
 968 msgid "SCF-8002-HE.impact"
 969 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 970 msgid "SCF-8002-HE.action"
 971 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 972 #
 973 # code: SCF-8002-JJ
 974 # keys: fault.chassis.jtag.device
 975 #
 976 msgid "SCF-8002-JJ.type"
 977 msgstr "Fault"
 978 msgid "SCF-8002-JJ.severity"
 979 msgstr "Critical"
 980 msgid "SCF-8002-JJ.description"
 981 msgstr "JTAG read or write failure to a specific chip.\n  Refer to %s for more information."
 982 msgid "SCF-8002-JJ.response"
 983 msgstr "The resources associated with the chip will be deconfigured. Please consult the detail section \nof the knowledge article for additional information.\n"
 984 msgid "SCF-8002-JJ.impact"
 985 msgstr "The platform may be reset or a domain may be reset. The platform may be unable to restart.\nPlease consult the detail section of the knowledge article for additional information.\n"


1985 msgstr "Defect"
1986 msgid "SCF-8005-NE.severity"
1987 msgstr "Major"
1988 msgid "SCF-8005-NE.description"
1989 msgstr "An XSCF firmware process has unexpectedly terminated. \n  Refer to %s for more information."
1990 msgid "SCF-8005-NE.response"
1991 msgstr "The XSCF firmware will be rebooted.\n"
1992 msgid "SCF-8005-NE.impact"
1993 msgstr "XSCF functionality will be unavailable until the XSCF has restarted.\n"
1994 msgid "SCF-8005-NE.action"
1995 msgstr "Schedule a repair action to upgrade the XCP firmware. Please consult the detail section \nof the knowledge article for additional information.\n"
1996 #
1997 # code: SCF-8005-PX
1998 # keys: upset.chassis.domain.panic
1999 #
2000 msgid "SCF-8005-PX.type"
2001 msgstr "Upset"
2002 msgid "SCF-8005-PX.severity"
2003 msgstr "Major"
2004 msgid "SCF-8005-PX.description"
2005 msgstr "The XSCF has detected that a Solaris domain has panic'ed.\n  Refer to %s for more information."
2006 msgid "SCF-8005-PX.response"
2007 msgstr "No action is taken due to this fault.\n"
2008 msgid "SCF-8005-PX.impact"
2009 msgstr "The Solaris domain has panic'ed.\n"
2010 msgid "SCF-8005-PX.action"
2011 msgstr "The administrator should look at the domain's console to identify the cause of the panic.\nPlease consult the detail section of the knowledge article for additional information.\n"
2012 #
2013 # code: SCF-8005-Q2
2014 # keys: upset.chassis.domain.config
2015 #
2016 msgid "SCF-8005-Q2.type"
2017 msgstr "Upset"
2018 msgid "SCF-8005-Q2.severity"
2019 msgstr "Major"
2020 msgid "SCF-8005-Q2.description"
2021 msgstr "The XSB could not be successfully configured into a domain.\n  Refer to %s for more information."
2022 msgid "SCF-8005-Q2.response"
2023 msgstr "Nothing is deconfigured.\n"
2024 msgid "SCF-8005-Q2.impact"
2025 msgstr "XSB is not successfully configured into a domain.\n"
2026 msgid "SCF-8005-Q2.action"
2027 msgstr "The platform administrator should investigate why the XSB could not be configured \ninto the domain. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2028 #
2029 # code: SCF-8005-RA




   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #


  24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # code: SCF-8000-1D
  28 # keys: fault.chassis.SPARC-Enterprise.if.fe-asic-clk
  29 #
  30 msgid "SCF-8000-1D.type"
  31 msgstr "Fault"
  32 msgid "SCF-8000-1D.severity"
  33 msgstr "Critical"
  34 msgid "SCF-8000-1D.description"
  35 msgstr "A fatal clock distribution error was detected by an ASIC or a CPU chip.\n  Refer to %s for more information."
  36 msgid "SCF-8000-1D.response"
  37 msgstr "An attempt will be made to deconfigure the faulty components after one or more domains are reset.\n"
  38 msgid "SCF-8000-1D.impact"
  39 msgstr "One or more domains will be reset. Please consult the detail section of the knowledge article for \nadditional information.\n"
  40 msgid "SCF-8000-1D.action"
  41 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
  42 #
  43 # code: SCF-8000-2Y


 463 msgstr "Fault"
 464 msgid "SCF-8001-AA.severity"
 465 msgstr "Major"
 466 msgid "SCF-8001-AA.description"
 467 msgstr "The number of correctable errors associated with a FLP chip has exceeded an\nacceptable threshold.\n  Refer to %s for more information."
 468 msgid "SCF-8001-AA.response"
 469 msgstr "The IO Channel associated with the FLP chip will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
 470 msgid "SCF-8001-AA.impact"
 471 msgstr "No immediate impact. The IO Channel associated with the FLP chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is \nperformed.\n"
 472 msgid "SCF-8001-AA.action"
 473 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
 474 #
 475 # code: SCF-8001-KC
 476 # keys: upset.chassis.SPARC-Enterprise.io.disk.boot
 477 #
 478 msgid "SCF-8001-KC.type"
 479 msgstr "upset"
 480 msgid "SCF-8001-KC.severity"
 481 msgstr "Critical"
 482 msgid "SCF-8001-KC.description"
 483 msgstr "Failure to boot illumos on a domain via an internal disk drive on the SAS controller.\n  Refer to %s for more information."
 484 msgid "SCF-8001-KC.response"
 485 msgstr "Nothing is deconfigured.\n"
 486 msgid "SCF-8001-KC.impact"
 487 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 488 msgid "SCF-8001-KC.action"
 489 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 490 #
 491 # code: SCF-8001-LQ
 492 # keys: fault.chassis.SPARC-Enterprise.if.fe-ioc-flp
 493 #
 494 msgid "SCF-8001-LQ.type"
 495 msgstr "Fault"
 496 msgid "SCF-8001-LQ.severity"
 497 msgstr "Critical"
 498 msgid "SCF-8001-LQ.description"
 499 msgstr "A fatal error occurred on the interface between an IOC chip and a FLP chip.\n  Refer to %s for more information."
 500 msgid "SCF-8001-LQ.response"
 501 msgstr "The IO Channel associated with the FLP chip will be deconfigured after the domain\nusing the IO Channel is reset.\n"
 502 msgid "SCF-8001-LQ.impact"
 503 msgstr "The domain using the IO Channel associated with the FLP chip is reset. The IO Channel will\ndeconfigured after the domain is reset.\n"


 831 msgstr "Fault"
 832 msgid "SCF-8002-8D.severity"
 833 msgstr "Major"
 834 msgid "SCF-8002-8D.description"
 835 msgstr "The number of correctable errors within a IOC Chip has exceeded an acceptable threshold. This fault\naffects a single IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
 836 msgid "SCF-8002-8D.response"
 837 msgstr "The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is power cycled or after \nthe domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
 838 msgid "SCF-8002-8D.impact"
 839 msgstr "No immediate impact. The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is \npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
 840 msgid "SCF-8002-8D.action"
 841 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
 842 #
 843 # code: SCF-8002-9H
 844 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.boot
 845 #
 846 msgid "SCF-8002-9H.type"
 847 msgstr "Upset"
 848 msgid "SCF-8002-9H.severity"
 849 msgstr "Critical"
 850 msgid "SCF-8002-9H.description"
 851 msgstr "Failure to boot illumos on a domain using a device on an IO Channel.\n  Refer to %s for more information."
 852 msgid "SCF-8002-9H.response"
 853 msgstr "Nothing is deconfigured.\n"
 854 msgid "SCF-8002-9H.impact"
 855 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 856 msgid "SCF-8002-9H.action"
 857 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
 858 #
 859 # code: SCF-8002-A3
 860 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.boot
 861 #
 862 msgid "SCF-8002-A3.type"
 863 msgstr "Upset"
 864 msgid "SCF-8002-A3.severity"
 865 msgstr "Critical"
 866 msgid "SCF-8002-A3.description"
 867 msgstr "Failure to boot illumos on a domain using a device on IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
 868 msgid "SCF-8002-A3.response"
 869 msgstr "Nothing is deconfigured.\n"
 870 msgid "SCF-8002-A3.impact"
 871 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 872 msgid "SCF-8002-A3.action"
 873 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
 874 #
 875 # code: SCF-8002-CY
 876 # keys: upset.chassis.SPARC-Enterprise.io.pci.gbe.boot
 877 #
 878 msgid "SCF-8002-CY.type"
 879 msgstr "Upset"
 880 msgid "SCF-8002-CY.severity"
 881 msgstr "Critical"
 882 msgid "SCF-8002-CY.description"
 883 msgstr "Failure to boot illumos on a domain via GbE.\n  Refer to %s for more information."
 884 msgid "SCF-8002-CY.response"
 885 msgstr "Nothing is deconfigured.\n"
 886 msgid "SCF-8002-CY.impact"
 887 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 888 msgid "SCF-8002-CY.action"
 889 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 890 #
 891 # code: SCF-8002-D5
 892 # keys: upset.chassis.SPARC-Enterprise.io.pci.card.boot
 893 #
 894 msgid "SCF-8002-D5.type"
 895 msgstr "Upset"
 896 msgid "SCF-8002-D5.severity"
 897 msgstr "Critical"
 898 msgid "SCF-8002-D5.description"
 899 msgstr "Failure to boot illumos on a domain using a device in a PCI-X slot.\n  Refer to %s for more information."
 900 msgid "SCF-8002-D5.response"
 901 msgstr "Nothing is deconfigured.\n"
 902 msgid "SCF-8002-D5.impact"
 903 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt\n"
 904 msgid "SCF-8002-D5.action"
 905 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 906 #
 907 # code: SCF-8002-ES
 908 # keys: upset.chassis.SPARC-Enterprise.io.pciex.card.boot
 909 #
 910 msgid "SCF-8002-ES.type"
 911 msgstr "Upset"
 912 msgid "SCF-8002-ES.severity"
 913 msgstr "Critical"
 914 msgid "SCF-8002-ES.description"
 915 msgstr "Failure to boot illumos on a domain using a device in a PCI-Express slot.\n  Refer to %s for more information."
 916 msgid "SCF-8002-ES.response"
 917 msgstr "Nothing is deconfigured.\n"
 918 msgid "SCF-8002-ES.impact"
 919 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 920 msgid "SCF-8002-ES.action"
 921 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 922 #
 923 # code: SCF-8002-FA
 924 # keys: upset.chassis.SPARC-Enterprise.io.pciex.bridge.boot
 925 #
 926 msgid "SCF-8002-FA.type"
 927 msgstr "Upset"
 928 msgid "SCF-8002-FA.severity"
 929 msgstr "Critical"
 930 msgid "SCF-8002-FA.description"
 931 msgstr "Failure to boot illumos on a domain using a device behind a PCI-Express/PCI-X \nbridge chip. This includes the PCI-X slot and internal I/O on an IOU (if the\nPCI-Express/PCI-X bridge is located on an IOU or IOUA) and the PCI-X slots of\nan I/O Boat (if the PCI-Express/PCI-X bridge is located on an I/O Boat).\n  Refer to %s for more information."
 932 msgid "SCF-8002-FA.response"
 933 msgstr "Nothing is deconfigured.\n"
 934 msgid "SCF-8002-FA.impact"
 935 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 936 msgid "SCF-8002-FA.action"
 937 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 938 #
 939 # code: SCF-8002-GP
 940 # keys: upset.chassis.SPARC-Enterprise.io.pciex.switch.boot
 941 #
 942 msgid "SCF-8002-GP.type"
 943 msgstr "upset"
 944 msgid "SCF-8002-GP.severity"
 945 msgstr "Critical"
 946 msgid "SCF-8002-GP.description"
 947 msgstr "Failure to boot illumos on a domain using a device behind a PCI-Express switch chip.\nThis includes PCI-X slot and internal I/O devices (if the PCI-Express switch chip \nis located on an IOU), and the PCI-Express slots and PCI-X slots on an I/O Boat\n(if the PCI-Express switch chip is located on an I/O Boat).\n  Refer to %s for more information."
 948 msgid "SCF-8002-GP.response"
 949 msgstr "Nothing is deconfigured.\n"
 950 msgid "SCF-8002-GP.impact"
 951 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 952 msgid "SCF-8002-GP.action"
 953 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 954 #
 955 # code: SCF-8002-HE
 956 # keys: upset.chassis.SPARC-Enterprise.io.pci.sas.boot
 957 #
 958 msgid "SCF-8002-HE.type"
 959 msgstr "Upset"
 960 msgid "SCF-8002-HE.severity"
 961 msgstr "Critical"
 962 msgid "SCF-8002-HE.description"
 963 msgstr "Failure to boot illumos on a domain using an internal SAS (Serial Attached\nSCSI) device. This includes the internal hard drives and the internal DVD drives\nand the internal tape drives.\n  Refer to %s for more information."
 964 msgid "SCF-8002-HE.response"
 965 msgstr "Nothing is deconfigured.\n"
 966 msgid "SCF-8002-HE.impact"
 967 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
 968 msgid "SCF-8002-HE.action"
 969 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
 970 #
 971 # code: SCF-8002-JJ
 972 # keys: fault.chassis.jtag.device
 973 #
 974 msgid "SCF-8002-JJ.type"
 975 msgstr "Fault"
 976 msgid "SCF-8002-JJ.severity"
 977 msgstr "Critical"
 978 msgid "SCF-8002-JJ.description"
 979 msgstr "JTAG read or write failure to a specific chip.\n  Refer to %s for more information."
 980 msgid "SCF-8002-JJ.response"
 981 msgstr "The resources associated with the chip will be deconfigured. Please consult the detail section \nof the knowledge article for additional information.\n"
 982 msgid "SCF-8002-JJ.impact"
 983 msgstr "The platform may be reset or a domain may be reset. The platform may be unable to restart.\nPlease consult the detail section of the knowledge article for additional information.\n"


1983 msgstr "Defect"
1984 msgid "SCF-8005-NE.severity"
1985 msgstr "Major"
1986 msgid "SCF-8005-NE.description"
1987 msgstr "An XSCF firmware process has unexpectedly terminated. \n  Refer to %s for more information."
1988 msgid "SCF-8005-NE.response"
1989 msgstr "The XSCF firmware will be rebooted.\n"
1990 msgid "SCF-8005-NE.impact"
1991 msgstr "XSCF functionality will be unavailable until the XSCF has restarted.\n"
1992 msgid "SCF-8005-NE.action"
1993 msgstr "Schedule a repair action to upgrade the XCP firmware. Please consult the detail section \nof the knowledge article for additional information.\n"
1994 #
1995 # code: SCF-8005-PX
1996 # keys: upset.chassis.domain.panic
1997 #
1998 msgid "SCF-8005-PX.type"
1999 msgstr "Upset"
2000 msgid "SCF-8005-PX.severity"
2001 msgstr "Major"
2002 msgid "SCF-8005-PX.description"
2003 msgstr "The XSCF has detected that an illumos domain has panic'ed.\n  Refer to %s for more information."
2004 msgid "SCF-8005-PX.response"
2005 msgstr "No action is taken due to this fault.\n"
2006 msgid "SCF-8005-PX.impact"
2007 msgstr "The illumos domain has panic'ed.\n"
2008 msgid "SCF-8005-PX.action"
2009 msgstr "The administrator should look at the domain's console to identify the cause of the panic.\nPlease consult the detail section of the knowledge article for additional information.\n"
2010 #
2011 # code: SCF-8005-Q2
2012 # keys: upset.chassis.domain.config
2013 #
2014 msgid "SCF-8005-Q2.type"
2015 msgstr "Upset"
2016 msgid "SCF-8005-Q2.severity"
2017 msgstr "Major"
2018 msgid "SCF-8005-Q2.description"
2019 msgstr "The XSB could not be successfully configured into a domain.\n  Refer to %s for more information."
2020 msgid "SCF-8005-Q2.response"
2021 msgstr "Nothing is deconfigured.\n"
2022 msgid "SCF-8005-Q2.impact"
2023 msgstr "XSB is not successfully configured into a domain.\n"
2024 msgid "SCF-8005-Q2.action"
2025 msgstr "The platform administrator should investigate why the XSB could not be configured \ninto the domain. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2026 #
2027 # code: SCF-8005-RA