Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
        
@@ -19,12 +19,10 @@
 # fields enclosed by brackets "[]" replaced with your own identifying
 # information: Portions Copyright [yyyy] [name of copyright owner]
 #
 # CDDL HEADER END
 #
-#ident  "%Z%%M% %I%     %E% SMI"
-#
 # DO NOT EDIT -- this file is generated by the Event Registry.
 #
 #
 # code: SCA500-8000-0D
 # keys: fault.io.sca500.hw
@@ -32,12 +30,12 @@
 msgid "SCA500-8000-0D.type"
 msgstr "Fault"
 msgid "SCA500-8000-0D.severity"
 msgstr "Major"
 msgid "SCA500-8000-0D.description"
-msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card.  Refer to %s for more information."
+msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card.  Refer to %s for more information."
 msgid "SCA500-8000-0D.response"
-msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework."
+msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework."
 msgid "SCA500-8000-0D.impact"
 msgstr "The card will no longer function as a cryptographic accelerator."
 msgid "SCA500-8000-0D.action"
-msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"
+msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 500 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"