8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>

Split Close
Expand all
Collapse all
          --- old/usr/src/cmd/fm/dicts/SCA1000.po
          +++ new/usr/src/cmd/fm/dicts/SCA1000.po
↓ open down ↓ 13 lines elided ↑ open up ↑
  14   14  # and limitations under the License.
  15   15  #
  16   16  # When distributing Covered Code, include this CDDL HEADER in each
  17   17  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18   18  # If applicable, add the following below this CDDL HEADER, with the
  19   19  # fields enclosed by brackets "[]" replaced with your own identifying
  20   20  # information: Portions Copyright [yyyy] [name of copyright owner]
  21   21  #
  22   22  # CDDL HEADER END
  23   23  #
  24      -#ident  "%Z%%M% %I%     %E% SMI"
  25      -#
  26   24  # DO NOT EDIT -- this file is generated by the Event Registry.
  27   25  #
  28   26  #
  29   27  # code: SCA1000-8000-0V
  30   28  # keys: fault.io.sca1000.hw
  31   29  #
  32   30  msgid "SCA1000-8000-0V.type"
  33   31  msgstr "Fault"
  34   32  msgid "SCA1000-8000-0V.severity"
  35   33  msgstr "Major"
  36   34  msgid "SCA1000-8000-0V.description"
  37      -msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card.  Refer to %s for more information."
       35 +msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card.  Refer to %s for more information."
  38   36  msgid "SCA1000-8000-0V.response"
  39      -msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework."
       37 +msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework."
  40   38  msgid "SCA1000-8000-0V.impact"
  41   39  msgstr "The card will no longer function as a cryptographic accelerator."
  42   40  msgid "SCA1000-8000-0V.action"
  43      -msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"
       41 +msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"
    