Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
@@ -19,12 +19,10 @@
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
-#ident "%Z%%M% %I% %E% SMI"
-#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# code: SCA1000-8000-0V
# keys: fault.io.sca1000.hw
@@ -32,12 +30,12 @@
msgid "SCA1000-8000-0V.type"
msgstr "Fault"
msgid "SCA1000-8000-0V.severity"
msgstr "Major"
msgid "SCA1000-8000-0V.description"
-msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card. Refer to %s for more information."
+msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card. Refer to %s for more information."
msgid "SCA1000-8000-0V.response"
-msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework."
+msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework."
msgid "SCA1000-8000-0V.impact"
msgstr "The card will no longer function as a cryptographic accelerator."
msgid "SCA1000-8000-0V.action"
-msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"
+msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"