1 #
   2 # Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #
  24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # code: SCA1000-8000-0V
  28 # keys: fault.io.sca1000.hw
  29 #
  30 msgid "SCA1000-8000-0V.type"
  31 msgstr "Fault"
  32 msgid "SCA1000-8000-0V.severity"
  33 msgstr "Major"
  34 msgid "SCA1000-8000-0V.description"
  35 msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card.  Refer to %s for more information."
  36 msgid "SCA1000-8000-0V.response"
  37 msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework."
  38 msgid "SCA1000-8000-0V.impact"
  39 msgstr "The card will no longer function as a cryptographic accelerator."
  40 msgid "SCA1000-8000-0V.action"
  41 msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"