Print this page
    
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
    
      
        | Split | 
	Close | 
      
      | Expand all | 
      | Collapse all | 
    
    
          --- old/usr/src/cmd/fm/dicts/PCI.po
          +++ new/usr/src/cmd/fm/dicts/PCI.po
   1    1  #
   2    2  # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
   3    3  # Use is subject to license terms.
   4    4  #
   5    5  # CDDL HEADER START
   6    6  #
   7    7  # The contents of this file are subject to the terms of the
   8    8  # Common Development and Distribution License (the "License").
   9    9  # You may not use this file except in compliance with the License.
  10   10  #
  11   11  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12   12  # or http://www.opensolaris.org/os/licensing.
  13   13  # See the License for the specific language governing permissions
  14   14  # and limitations under the License.
  15   15  #
  16   16  # When distributing Covered Code, include this CDDL HEADER in each
  17   17  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18   18  # If applicable, add the following below this CDDL HEADER, with the
  19   19  # fields enclosed by brackets "[]" replaced with your own identifying
  20   20  # information: Portions Copyright [yyyy] [name of copyright owner]
  21   21  #
  22   22  # CDDL HEADER END
  23   23  #
  24   24  # DO NOT EDIT -- this file is generated by the Event Registry.
  25   25  #
  26   26  #
  27   27  # code: PCI-8000-0C
  28   28  # keys: defect.io.pci.driver
  29   29  #
  30   30  msgid "PCI-8000-0C.type"
  
    | 
      ↓ open down ↓ | 
    30 lines elided | 
    
      ↑ open up ↑ | 
  
  31   31  msgstr "Fault"
  32   32  msgid "PCI-8000-0C.severity"
  33   33  msgstr "Critical"
  34   34  msgid "PCI-8000-0C.description"
  35   35  msgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
  36   36  msgid "PCI-8000-0C.response"
  37   37  msgstr "One or more of device instances may be disabled."
  38   38  msgid "PCI-8000-0C.impact"
  39   39  msgstr "Loss of services provided by the device instances associated with this problem."
  40   40  msgid "PCI-8000-0C.action"
  41      -msgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
       41 +msgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
  42   42  #
  43   43  # code: PCI-8000-1Q
  44   44  # keys: fault.io.pci.bus
  45   45  #
  46   46  msgid "PCI-8000-1Q.type"
  47   47  msgstr "Fault"
  48   48  msgid "PCI-8000-1Q.severity"
  49   49  msgstr "Critical"
  50   50  msgid "PCI-8000-1Q.description"
  51   51  msgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
  52   52  msgid "PCI-8000-1Q.response"
  53   53  msgstr "One or more device instances may be disabled."
  54   54  msgid "PCI-8000-1Q.impact"
  55   55  msgstr "Loss of services provided by the device instances associated with this fault."
  56   56  msgid "PCI-8000-1Q.action"
  57      -msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
       57 +msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
  58   58  #
  59   59  # code: PCI-8000-24
  60   60  # keys: defect.io.pci.driver fault.io.pci.bus
  61   61  #
  62   62  msgid "PCI-8000-24.type"
  63   63  msgstr "Fault"
  64   64  msgid "PCI-8000-24.severity"
  65   65  msgstr "Critical"
  66   66  msgid "PCI-8000-24.description"
  67   67  msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
  68   68  msgid "PCI-8000-24.response"
  69   69  msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
  70   70  msgid "PCI-8000-24.impact"
  71   71  msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
  72   72  msgid "PCI-8000-24.action"
  73   73  msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
  74   74  #
  75   75  # code: PCI-8000-3R
  76   76  # keys: fault.io.pci.device
  77   77  #
  78   78  msgid "PCI-8000-3R.type"
  79   79  msgstr "Fault"
  80   80  msgid "PCI-8000-3R.severity"
  81   81  msgstr "Critical"
  82   82  msgid "PCI-8000-3R.description"
  83   83  msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
  84   84  msgid "PCI-8000-3R.response"
  85   85  msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
  86   86  msgid "PCI-8000-3R.impact"
  87   87  msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
  88   88  msgid "PCI-8000-3R.action"
  89   89  msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
  90   90  #
  91   91  # code: PCI-8000-42
  92   92  # keys: defect.io.pci.driver fault.io.pci.device
  93   93  #
  94   94  msgid "PCI-8000-42.type"
  95   95  msgstr "Fault"
  96   96  msgid "PCI-8000-42.severity"
  97   97  msgstr "Critical"
  98   98  msgid "PCI-8000-42.description"
  99   99  msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
 100  100  msgid "PCI-8000-42.response"
 101  101  msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
 102  102  msgid "PCI-8000-42.impact"
 103  103  msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
 104  104  msgid "PCI-8000-42.action"
 105  105  msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
 106  106  #
 107  107  # code: PCI-8000-5X
 108  108  # keys: fault.io.pci.bus fault.io.pci.device
 109  109  #
 110  110  msgid "PCI-8000-5X.type"
 111  111  msgstr "Fault"
 112  112  msgid "PCI-8000-5X.severity"
 113  113  msgstr "Critical"
 114  114  msgid "PCI-8000-5X.description"
 115  115  msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
 116  116  msgid "PCI-8000-5X.response"
 117  117  msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
 118  118  msgid "PCI-8000-5X.impact"
 119  119  msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
 120  120  msgid "PCI-8000-5X.action"
 121  121  msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
 122  122  #
 123  123  # code: PCI-8000-6E
 124  124  # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
 125  125  #
 126  126  msgid "PCI-8000-6E.type"
 127  127  msgstr "Fault"
 128  128  msgid "PCI-8000-6E.severity"
 129  129  msgstr "Critical"
 130  130  msgid "PCI-8000-6E.description"
 131  131  msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
 132  132  msgid "PCI-8000-6E.response"
 133  133  msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
 134  134  msgid "PCI-8000-6E.impact"
 135  135  msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
 136  136  msgid "PCI-8000-6E.action"
 137  137  msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
 138  138  #
 139  139  # code: PCI-8000-7J
 140  140  # keys: fault.io.pci.device-interr
 141  141  #
 142  142  msgid "PCI-8000-7J.type"
  
    | 
      ↓ open down ↓ | 
    75 lines elided | 
    
      ↑ open up ↑ | 
  
 143  143  msgstr "Fault"
 144  144  msgid "PCI-8000-7J.severity"
 145  145  msgstr "Critical"
 146  146  msgid "PCI-8000-7J.description"
 147  147  msgstr "An unrecoverable problem was detected for a PCI device.\n  Refer to %s for more information."
 148  148  msgid "PCI-8000-7J.response"
 149  149  msgstr "One or more device instances may be disabled\n"
 150  150  msgid "PCI-8000-7J.impact"
 151  151  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 152  152  msgid "PCI-8000-7J.action"
 153      -msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
      153 +msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
 154  154  #
 155  155  # code: PCI-8000-8S
 156  156  # keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
 157  157  #
 158  158  msgid "PCI-8000-8S.type"
 159  159  msgstr "Fault"
 160  160  msgid "PCI-8000-8S.severity"
 161  161  msgstr "Critical"
 162  162  msgid "PCI-8000-8S.description"
 163  163  msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
 164  164  msgid "PCI-8000-8S.response"
 165  165  msgstr "One or more device instances may be disabled\n"
 166  166  msgid "PCI-8000-8S.impact"
 167  167  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 168  168  msgid "PCI-8000-8S.action"
 169      -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
      169 +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
 170  170  #
 171  171  # code: PCI-8000-95
 172  172  # keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
 173  173  #
 174  174  msgid "PCI-8000-95.type"
 175  175  msgstr "Fault"
 176  176  msgid "PCI-8000-95.severity"
 177  177  msgstr "Major"
 178  178  msgid "PCI-8000-95.description"
 179  179  msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
 180  180  msgid "PCI-8000-95.response"
 181  181  msgstr "One or more device instances may be disabled\n"
 182  182  msgid "PCI-8000-95.impact"
 183  183  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 184  184  msgid "PCI-8000-95.action"
 185      -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
      185 +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n"
 186  186  #
 187  187  # code: PCI-8000-AP
 188  188  # keys: fault.io.pci.device-interr fault.io.pci.device-invreq
 189  189  #
 190  190  msgid "PCI-8000-AP.type"
 191  191  msgstr "Fault"
 192  192  msgid "PCI-8000-AP.severity"
 193  193  msgstr "Major"
 194  194  msgid "PCI-8000-AP.description"
 195  195  msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
 196  196  msgid "PCI-8000-AP.response"
 197  197  msgstr "One or more device instances may be disabled\n"
 198  198  msgid "PCI-8000-AP.impact"
 199  199  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 200  200  msgid "PCI-8000-AP.action"
 201      -msgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
      201 +msgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n"
 202  202  #
 203  203  # code: PCI-8000-CA
 204  204  # keys: fault.io.pci.device-noresp
 205  205  #
 206  206  msgid "PCI-8000-CA.type"
 207  207  msgstr "Fault"
 208  208  msgid "PCI-8000-CA.severity"
 209  209  msgstr "Major"
 210  210  msgid "PCI-8000-CA.description"
 211  211  msgstr "A device is failing to respond\n  Refer to %s for more information."
 212  212  msgid "PCI-8000-CA.response"
 213  213  msgstr "One or more device instances may be disabled\n"
 214  214  msgid "PCI-8000-CA.impact"
 215  215  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 216  216  msgid "PCI-8000-CA.action"
 217      -msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
      217 +msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
 218  218  #
 219  219  # code: PCI-8000-DH
 220  220  # keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf
 221  221  #
 222  222  msgid "PCI-8000-DH.type"
 223  223  msgstr "Fault"
 224  224  msgid "PCI-8000-DH.severity"
 225  225  msgstr "Major"
 226  226  msgid "PCI-8000-DH.description"
 227  227  msgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n  Refer to %s for more information."
 228  228  msgid "PCI-8000-DH.response"
 229  229  msgstr "One or more device instances may be disabled\n"
 230  230  msgid "PCI-8000-DH.impact"
 231  231  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 232  232  msgid "PCI-8000-DH.action"
 233      -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
      233 +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
 234  234  #
 235  235  # code: PCI-8000-ED
 236  236  # keys: fault.io.pci.device-interr-corr
 237  237  #
 238  238  msgid "PCI-8000-ED.type"
 239  239  msgstr "Fault"
 240  240  msgid "PCI-8000-ED.severity"
 241  241  msgstr "Major"
 242  242  msgid "PCI-8000-ED.description"
 243  243  msgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n  Refer to %s for more information."
 244  244  msgid "PCI-8000-ED.response"
 245  245  msgstr "One or more device instances may be disabled\n"
 246  246  msgid "PCI-8000-ED.impact"
 247  247  msgstr "Possible loss of services provided by the device instances associated with this fault\n"
 248  248  msgid "PCI-8000-ED.action"
 249      -msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
      249 +msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
 250  250  #
 251  251  # code: PCI-8000-FY
 252  252  # keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg
 253  253  #
 254  254  msgid "PCI-8000-FY.type"
 255  255  msgstr "Fault"
 256  256  msgid "PCI-8000-FY.severity"
 257  257  msgstr "Major"
 258  258  msgid "PCI-8000-FY.description"
 259  259  msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
 260  260  msgid "PCI-8000-FY.response"
 261  261  msgstr "None\n"
 262  262  msgid "PCI-8000-FY.impact"
 263  263  msgstr "Degraded services provided by the device instances associated with this fault\n"
 264  264  msgid "PCI-8000-FY.action"
 265      -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
      265 +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
 266  266  #
 267  267  # code: PCI-8000-G3
 268  268  # keys: fault.io.pci.device-interr-deg
 269  269  #
 270  270  msgid "PCI-8000-G3.type"
 271  271  msgstr "Fault"
 272  272  msgid "PCI-8000-G3.severity"
 273  273  msgstr "Major"
 274  274  msgid "PCI-8000-G3.description"
 275  275  msgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
 276  276  msgid "PCI-8000-G3.response"
 277  277  msgstr "None\n"
 278  278  msgid "PCI-8000-G3.impact"
 279  279  msgstr "Degraded services provided by the device instances associated with this fault\n"
 280  280  msgid "PCI-8000-G3.action"
 281      -msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
      281 +msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
 282  282  #
 283  283  # code: PCI-8000-HR
 284  284  # keys: fault.io.pci.fw_corrupt
 285  285  #
 286  286  msgid "PCI-8000-HR.type"
 287  287  msgstr "Fault"
 288  288  msgid "PCI-8000-HR.severity"
 289  289  msgstr "Major"
 290  290  msgid "PCI-8000-HR.description"
 291  291  msgstr "A firmware corruption was detected for a PCI device.\n  Refer to %s for more information."
 292  292  msgid "PCI-8000-HR.response"
 293  293  msgstr "One or more device instances may be disabled.\n"
 294  294  msgid "PCI-8000-HR.impact"
 295  295  msgstr "Degraded services provided by the device instances associated with this fault.\n"
 296  296  msgid "PCI-8000-HR.action"
 297      -msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n"
      297 +msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact your illumos distribution team for further information.\n"
 298  298  #
 299  299  # code: PCI-8000-J4
 300  300  # keys: fault.io.pci.fw_mismatch
 301  301  #
 302  302  msgid "PCI-8000-J4.type"
 303  303  msgstr "Fault"
 304  304  msgid "PCI-8000-J4.severity"
 305  305  msgstr "Major"
 306  306  msgid "PCI-8000-J4.description"
 307  307  msgstr "A firmware version mismatch was detected for a PCI device.\n  Refer to %s for more information."
 308  308  msgid "PCI-8000-J4.response"
 309  309  msgstr "One or more device instances may be disabled.\n"
 310  310  msgid "PCI-8000-J4.impact"
 311  311  msgstr "Degraded services provided by the device instances associated with this fault.\n"
 312  312  msgid "PCI-8000-J4.action"
 313      -msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n"
      313 +msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact your illumos distribution team for further information.\n"
    
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX