Print this page
    
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
    
      
        | Split | 
	Close | 
      
      | Expand all | 
      | Collapse all | 
    
    
          --- old/usr/src/cmd/fm/dicts/INTEL.po
          +++ new/usr/src/cmd/fm/dicts/INTEL.po
   1    1  #
   2    2  # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
   3    3  # Use is subject to license terms.
   4    4  #
   5    5  # CDDL HEADER START
   6    6  #
   7    7  # The contents of this file are subject to the terms of the
   8    8  # Common Development and Distribution License (the "License").
   9    9  # You may not use this file except in compliance with the License.
  10   10  #
  11   11  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12   12  # or http://www.opensolaris.org/os/licensing.
  13   13  # See the License for the specific language governing permissions
  14   14  # and limitations under the License.
  15   15  #
  16   16  # When distributing Covered Code, include this CDDL HEADER in each
  17   17  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18   18  # If applicable, add the following below this CDDL HEADER, with the
  19   19  # fields enclosed by brackets "[]" replaced with your own identifying
  20   20  # information: Portions Copyright [yyyy] [name of copyright owner]
  21   21  #
  22   22  # CDDL HEADER END
  23   23  #
  24   24  # DO NOT EDIT -- this file is generated by the Event Registry.
  25   25  #
  26   26  #
  27   27  # code: INTEL-8000-1J
  28   28  # keys: fault.cpu.intel.internal
  29   29  #
  30   30  msgid "INTEL-8000-1J.type"
  31   31  msgstr "Fault"
  32   32  msgid "INTEL-8000-1J.severity"
  33   33  msgstr "Major"
  34   34  msgid "INTEL-8000-1J.description"
  35   35  msgstr "An internal error has been encountered on this cpu.  Refer to %s for more information."
  36   36  msgid "INTEL-8000-1J.response"
  37   37  msgstr "The system will attempt to offline this cpu to remove it from service."
  38   38  msgid "INTEL-8000-1J.impact"
  39   39  msgstr "Performance of this system may be affected."
  40   40  msgid "INTEL-8000-1J.action"
  41   41  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
  42   42  #
  43   43  # code: INTEL-8000-22
  44   44  # keys: fault.cpu.intel.l0cache
  45   45  #
  46   46  msgid "INTEL-8000-22.type"
  47   47  msgstr "Fault"
  48   48  msgid "INTEL-8000-22.severity"
  49   49  msgstr "Major"
  50   50  msgid "INTEL-8000-22.description"
  51   51  msgstr "A level 0 cache on this cpu is faulty.  Refer to %s for more information."
  52   52  msgid "INTEL-8000-22.response"
  53   53  msgstr "The system will attempt to offline this cpu to remove it from service."
  54   54  msgid "INTEL-8000-22.impact"
  55   55  msgstr "Performance of this system may be affected."
  56   56  msgid "INTEL-8000-22.action"
  57   57  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
  58   58  #
  59   59  # code: INTEL-8000-3X
  60   60  # keys: fault.cpu.intel.l1cache
  61   61  #
  62   62  msgid "INTEL-8000-3X.type"
  63   63  msgstr "Fault"
  64   64  msgid "INTEL-8000-3X.severity"
  65   65  msgstr "Major"
  66   66  msgid "INTEL-8000-3X.description"
  67   67  msgstr "A level 1 cache on this cpu is faulty.  Refer to %s for more information."
  68   68  msgid "INTEL-8000-3X.response"
  69   69  msgstr "The system will attempt to offline this cpu to remove it from service."
  70   70  msgid "INTEL-8000-3X.impact"
  71   71  msgstr "Performance of this system may be affected."
  72   72  msgid "INTEL-8000-3X.action"
  73   73  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
  74   74  #
  75   75  # code: INTEL-8000-44
  76   76  # keys: fault.cpu.intel.l2cache
  77   77  #
  78   78  msgid "INTEL-8000-44.type"
  79   79  msgstr "Fault"
  80   80  msgid "INTEL-8000-44.severity"
  81   81  msgstr "Major"
  82   82  msgid "INTEL-8000-44.description"
  83   83  msgstr "A level 2 cache on this cpu is faulty.  Refer to %s for more information."
  84   84  msgid "INTEL-8000-44.response"
  85   85  msgstr "The system will attempt to offline this cpu to remove it from service."
  86   86  msgid "INTEL-8000-44.impact"
  87   87  msgstr "Performance of this system may be affected."
  88   88  msgid "INTEL-8000-44.action"
  89   89  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
  90   90  #
  91   91  # code: INTEL-8000-5R
  92   92  # keys: fault.cpu.intel.cache
  93   93  #
  94   94  msgid "INTEL-8000-5R.type"
  95   95  msgstr "Fault"
  96   96  msgid "INTEL-8000-5R.severity"
  97   97  msgstr "Major"
  98   98  msgid "INTEL-8000-5R.description"
  99   99  msgstr "A cache on this cpu is faulty.  Refer to %s for more information."
 100  100  msgid "INTEL-8000-5R.response"
 101  101  msgstr "The system will attempt to offline this cpu to remove it from service."
 102  102  msgid "INTEL-8000-5R.impact"
 103  103  msgstr "Performance of this system may be affected."
 104  104  msgid "INTEL-8000-5R.action"
 105  105  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 106  106  #
 107  107  # code: INTEL-8000-6C
 108  108  # keys: fault.cpu.intel.l0dtlb
 109  109  #
 110  110  msgid "INTEL-8000-6C.type"
 111  111  msgstr "Fault"
 112  112  msgid "INTEL-8000-6C.severity"
 113  113  msgstr "Major"
 114  114  msgid "INTEL-8000-6C.description"
 115  115  msgstr "A level 0 Data TLB on this cpu is faulty.  Refer to %s for more information."
 116  116  msgid "INTEL-8000-6C.response"
 117  117  msgstr "The system will attempt to offline this cpu to remove it from service."
 118  118  msgid "INTEL-8000-6C.impact"
 119  119  msgstr "Performance of this system may be affected."
 120  120  msgid "INTEL-8000-6C.action"
 121  121  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 122  122  #
 123  123  # code: INTEL-8000-7Q
 124  124  # keys: fault.cpu.intel.l1dtlb
 125  125  #
 126  126  msgid "INTEL-8000-7Q.type"
 127  127  msgstr "Fault"
 128  128  msgid "INTEL-8000-7Q.severity"
 129  129  msgstr "Major"
 130  130  msgid "INTEL-8000-7Q.description"
 131  131  msgstr "A level 1 Data TLB on this cpu is faulty.  Refer to %s for more information."
 132  132  msgid "INTEL-8000-7Q.response"
 133  133  msgstr "The system will attempt to offline this cpu to remove it from service."
 134  134  msgid "INTEL-8000-7Q.impact"
 135  135  msgstr "Performance of this system may be affected."
 136  136  msgid "INTEL-8000-7Q.action"
 137  137  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 138  138  #
 139  139  # code: INTEL-8000-8Y
 140  140  # keys: fault.cpu.intel.l2dtlb
 141  141  #
 142  142  msgid "INTEL-8000-8Y.type"
 143  143  msgstr "Fault"
 144  144  msgid "INTEL-8000-8Y.severity"
 145  145  msgstr "Major"
 146  146  msgid "INTEL-8000-8Y.description"
 147  147  msgstr "A level 2 Data TLB on this cpu is faulty.  Refer to %s for more information."
 148  148  msgid "INTEL-8000-8Y.response"
 149  149  msgstr "The system will attempt to offline this cpu to remove it from service."
 150  150  msgid "INTEL-8000-8Y.impact"
 151  151  msgstr "Performance of this system may be affected."
 152  152  msgid "INTEL-8000-8Y.action"
 153  153  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 154  154  #
 155  155  # code: INTEL-8000-93
 156  156  # keys: fault.cpu.intel.dtlb
 157  157  #
 158  158  msgid "INTEL-8000-93.type"
 159  159  msgstr "Fault"
 160  160  msgid "INTEL-8000-93.severity"
 161  161  msgstr "Major"
 162  162  msgid "INTEL-8000-93.description"
 163  163  msgstr "A Data TLB on this cpu is faulty.  Refer to %s for more information."
 164  164  msgid "INTEL-8000-93.response"
 165  165  msgstr "The system will attempt to offline this cpu to remove it from service."
 166  166  msgid "INTEL-8000-93.impact"
 167  167  msgstr "Performance of this system may be affected."
 168  168  msgid "INTEL-8000-93.action"
 169  169  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 170  170  #
 171  171  # code: INTEL-8000-AH
 172  172  # keys: fault.cpu.intel.l0itlb
 173  173  #
 174  174  msgid "INTEL-8000-AH.type"
 175  175  msgstr "Fault"
 176  176  msgid "INTEL-8000-AH.severity"
 177  177  msgstr "Major"
 178  178  msgid "INTEL-8000-AH.description"
 179  179  msgstr "A level 0 Instruction TLB on this cpu is faulty.  Refer to %s for more information."
 180  180  msgid "INTEL-8000-AH.response"
 181  181  msgstr "The system will attempt to offline this cpu to remove it from service."
 182  182  msgid "INTEL-8000-AH.impact"
 183  183  msgstr "Performance of this system may be affected."
 184  184  msgid "INTEL-8000-AH.action"
 185  185  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 186  186  #
 187  187  # code: INTEL-8000-CD
 188  188  # keys: fault.cpu.intel.l1itlb
 189  189  #
 190  190  msgid "INTEL-8000-CD.type"
 191  191  msgstr "Fault"
 192  192  msgid "INTEL-8000-CD.severity"
 193  193  msgstr "Major"
 194  194  msgid "INTEL-8000-CD.description"
 195  195  msgstr "A level 1 Instruction TLB on this cpu is faulty.  Refer to %s for more information."
 196  196  msgid "INTEL-8000-CD.response"
 197  197  msgstr "The system will attempt to offline this cpu to remove it from service."
 198  198  msgid "INTEL-8000-CD.impact"
 199  199  msgstr "Performance of this system may be affected."
 200  200  msgid "INTEL-8000-CD.action"
 201  201  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 202  202  #
 203  203  # code: INTEL-8000-DP
 204  204  # keys: fault.cpu.intel.l2itlb
 205  205  #
 206  206  msgid "INTEL-8000-DP.type"
 207  207  msgstr "Fault"
 208  208  msgid "INTEL-8000-DP.severity"
 209  209  msgstr "Major"
 210  210  msgid "INTEL-8000-DP.description"
 211  211  msgstr "A level 2 Instruction TLB on this cpu is faulty.  Refer to %s for more information."
 212  212  msgid "INTEL-8000-DP.response"
 213  213  msgstr "The system will attempt to offline this cpu to remove it from service."
 214  214  msgid "INTEL-8000-DP.impact"
 215  215  msgstr "Performance of this system may be affected."
 216  216  msgid "INTEL-8000-DP.action"
 217  217  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 218  218  #
 219  219  # code: INTEL-8000-EA
 220  220  # keys: fault.cpu.intel.itlb
 221  221  #
 222  222  msgid "INTEL-8000-EA.type"
 223  223  msgstr "Fault"
 224  224  msgid "INTEL-8000-EA.severity"
 225  225  msgstr "Major"
 226  226  msgid "INTEL-8000-EA.description"
 227  227  msgstr "An Instruction TLB on this cpu is faulty.  Refer to %s for more information."
 228  228  msgid "INTEL-8000-EA.response"
 229  229  msgstr "The system will attempt to offline this cpu to remove it from service."
 230  230  msgid "INTEL-8000-EA.impact"
 231  231  msgstr "Performance of this system may be affected."
 232  232  msgid "INTEL-8000-EA.action"
 233  233  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 234  234  #
 235  235  # code: INTEL-8000-FS
 236  236  # keys: fault.cpu.intel.l0tlb
 237  237  #
 238  238  msgid "INTEL-8000-FS.type"
 239  239  msgstr "Fault"
 240  240  msgid "INTEL-8000-FS.severity"
 241  241  msgstr "Major"
 242  242  msgid "INTEL-8000-FS.description"
 243  243  msgstr "A level 0 TLB on this cpu is faulty.  Refer to %s for more information."
 244  244  msgid "INTEL-8000-FS.response"
 245  245  msgstr "The system will attempt to offline this cpu to remove it from service."
 246  246  msgid "INTEL-8000-FS.impact"
 247  247  msgstr "Performance of this system may be affected."
 248  248  msgid "INTEL-8000-FS.action"
 249  249  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 250  250  #
 251  251  # code: INTEL-8000-G5
 252  252  # keys: fault.cpu.intel.l1tlb
 253  253  #
 254  254  msgid "INTEL-8000-G5.type"
 255  255  msgstr "Fault"
 256  256  msgid "INTEL-8000-G5.severity"
 257  257  msgstr "Major"
 258  258  msgid "INTEL-8000-G5.description"
 259  259  msgstr "A level 1 TLB on this cpu is faulty.  Refer to %s for more information."
 260  260  msgid "INTEL-8000-G5.response"
 261  261  msgstr "The system will attempt to offline this cpu to remove it from service."
 262  262  msgid "INTEL-8000-G5.impact"
 263  263  msgstr "Performance of this system may be affected."
 264  264  msgid "INTEL-8000-G5.action"
 265  265  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 266  266  #
 267  267  # code: INTEL-8000-HX
 268  268  # keys: fault.cpu.intel.l2tlb
 269  269  #
 270  270  msgid "INTEL-8000-HX.type"
 271  271  msgstr "Fault"
 272  272  msgid "INTEL-8000-HX.severity"
 273  273  msgstr "Major"
 274  274  msgid "INTEL-8000-HX.description"
 275  275  msgstr "A level 2 TLB on this cpu is faulty.  Refer to %s for more information."
 276  276  msgid "INTEL-8000-HX.response"
 277  277  msgstr "The system will attempt to offline this cpu to remove it from service."
 278  278  msgid "INTEL-8000-HX.impact"
 279  279  msgstr "Performance of this system may be affected."
 280  280  msgid "INTEL-8000-HX.action"
 281  281  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 282  282  #
 283  283  # code: INTEL-8000-J2
 284  284  # keys: fault.cpu.intel.tlb
 285  285  #
 286  286  msgid "INTEL-8000-J2.type"
 287  287  msgstr "Fault"
 288  288  msgid "INTEL-8000-J2.severity"
 289  289  msgstr "Major"
 290  290  msgid "INTEL-8000-J2.description"
 291  291  msgstr "A TLB on this cpu is faulty.  Refer to %s for more information."
 292  292  msgid "INTEL-8000-J2.response"
 293  293  msgstr "The system will attempt to offline this cpu to remove it from service."
 294  294  msgid "INTEL-8000-J2.impact"
 295  295  msgstr "Performance of this system may be affected."
 296  296  msgid "INTEL-8000-J2.action"
 297  297  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 298  298  #
 299  299  # code: INTEL-8000-KJ
 300  300  # keys: fault.cpu.intel.l0dcache
 301  301  #
 302  302  msgid "INTEL-8000-KJ.type"
 303  303  msgstr "Fault"
 304  304  msgid "INTEL-8000-KJ.severity"
 305  305  msgstr "Major"
 306  306  msgid "INTEL-8000-KJ.description"
 307  307  msgstr "A level 0 Data Cache on this cpu is faulty.  Refer to %s for more information."
 308  308  msgid "INTEL-8000-KJ.response"
 309  309  msgstr "The system will attempt to offline this cpu to remove it from service."
 310  310  msgid "INTEL-8000-KJ.impact"
 311  311  msgstr "Performance of this system may be affected."
 312  312  msgid "INTEL-8000-KJ.action"
 313  313  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 314  314  #
 315  315  # code: INTEL-8000-LE
 316  316  # keys: fault.cpu.intel.l1dcache
 317  317  #
 318  318  msgid "INTEL-8000-LE.type"
 319  319  msgstr "Fault"
 320  320  msgid "INTEL-8000-LE.severity"
 321  321  msgstr "Major"
 322  322  msgid "INTEL-8000-LE.description"
 323  323  msgstr "A level 1 Data Cache on this cpu is faulty.  Refer to %s for more information."
 324  324  msgid "INTEL-8000-LE.response"
 325  325  msgstr "The system will attempt to offline this cpu to remove it from service."
 326  326  msgid "INTEL-8000-LE.impact"
 327  327  msgstr "Performance of this system may be affected."
 328  328  msgid "INTEL-8000-LE.action"
 329  329  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 330  330  #
 331  331  # code: INTEL-8000-MQ
 332  332  # keys: fault.cpu.intel.l2dcache
 333  333  #
 334  334  msgid "INTEL-8000-MQ.type"
 335  335  msgstr "Fault"
 336  336  msgid "INTEL-8000-MQ.severity"
 337  337  msgstr "Major"
 338  338  msgid "INTEL-8000-MQ.description"
 339  339  msgstr "A level 2 Data Cache on this cpu is faulty.  Refer to %s for more information."
 340  340  msgid "INTEL-8000-MQ.response"
 341  341  msgstr "The system will attempt to offline this cpu to remove it from service."
 342  342  msgid "INTEL-8000-MQ.impact"
 343  343  msgstr "Performance of this system may be affected."
 344  344  msgid "INTEL-8000-MQ.action"
 345  345  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 346  346  #
 347  347  # code: INTEL-8000-NC
 348  348  # keys: fault.cpu.intel.dcache
 349  349  #
 350  350  msgid "INTEL-8000-NC.type"
 351  351  msgstr "Fault"
 352  352  msgid "INTEL-8000-NC.severity"
 353  353  msgstr "Major"
 354  354  msgid "INTEL-8000-NC.description"
 355  355  msgstr "A Data Cache on this cpu is faulty.  Refer to %s for more information."
 356  356  msgid "INTEL-8000-NC.response"
 357  357  msgstr "The system will attempt to offline this cpu to remove it from service."
 358  358  msgid "INTEL-8000-NC.impact"
 359  359  msgstr "Performance of this system may be affected."
 360  360  msgid "INTEL-8000-NC.action"
 361  361  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 362  362  #
 363  363  # code: INTEL-8000-PR
 364  364  # keys: fault.cpu.intel.l0icache
 365  365  #
 366  366  msgid "INTEL-8000-PR.type"
 367  367  msgstr "Fault"
 368  368  msgid "INTEL-8000-PR.severity"
 369  369  msgstr "Major"
 370  370  msgid "INTEL-8000-PR.description"
 371  371  msgstr "A level 0 Instruction Cache on this cpu is faulty.  Refer to %s for more information."
 372  372  msgid "INTEL-8000-PR.response"
 373  373  msgstr "The system will attempt to offline this cpu to remove it from service."
 374  374  msgid "INTEL-8000-PR.impact"
 375  375  msgstr "Performance of this system may be affected."
 376  376  msgid "INTEL-8000-PR.action"
 377  377  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 378  378  #
 379  379  # code: INTEL-8000-Q4
 380  380  # keys: fault.cpu.intel.l1icache
 381  381  #
 382  382  msgid "INTEL-8000-Q4.type"
 383  383  msgstr "Fault"
 384  384  msgid "INTEL-8000-Q4.severity"
 385  385  msgstr "Major"
 386  386  msgid "INTEL-8000-Q4.description"
 387  387  msgstr "A level 1 Instruction Cache on this cpu is faulty.  Refer to %s for more information."
 388  388  msgid "INTEL-8000-Q4.response"
 389  389  msgstr "The system will attempt to offline this cpu to remove it from service."
 390  390  msgid "INTEL-8000-Q4.impact"
 391  391  msgstr "Performance of this system may be affected."
 392  392  msgid "INTEL-8000-Q4.action"
 393  393  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 394  394  #
 395  395  # code: INTEL-8000-RD
 396  396  # keys: fault.cpu.intel.l2icache
 397  397  #
 398  398  msgid "INTEL-8000-RD.type"
 399  399  msgstr "Fault"
 400  400  msgid "INTEL-8000-RD.severity"
 401  401  msgstr "Major"
 402  402  msgid "INTEL-8000-RD.description"
 403  403  msgstr "A level 2 Instruction Cache on this cpu is faulty.  Refer to %s for more information."
 404  404  msgid "INTEL-8000-RD.response"
 405  405  msgstr "The system will attempt to offline this cpu to remove it from service."
 406  406  msgid "INTEL-8000-RD.impact"
 407  407  msgstr "Performance of this system may be affected."
 408  408  msgid "INTEL-8000-RD.action"
 409  409  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 410  410  #
 411  411  # code: INTEL-8000-SH
 412  412  # keys: fault.cpu.intel.icache
 413  413  #
 414  414  msgid "INTEL-8000-SH.type"
 415  415  msgstr "Fault"
 416  416  msgid "INTEL-8000-SH.severity"
 417  417  msgstr "Major"
 418  418  msgid "INTEL-8000-SH.description"
 419  419  msgstr "An Instruction Cache on this cpu is faulty.  Refer to %s for more information."
 420  420  msgid "INTEL-8000-SH.response"
 421  421  msgstr "The system will attempt to offline this cpu to remove it from service."
 422  422  msgid "INTEL-8000-SH.impact"
 423  423  msgstr "Performance of this system may be affected."
 424  424  msgid "INTEL-8000-SH.action"
 425  425  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 426  426  #
 427  427  # code: INTEL-8000-T3
 428  428  # keys: fault.cpu.intel.bus_interconnect
 429  429  #
 430  430  msgid "INTEL-8000-T3.type"
 431  431  msgstr "Fault"
 432  432  msgid "INTEL-8000-T3.severity"
 433  433  msgstr "Major"
 434  434  msgid "INTEL-8000-T3.description"
 435  435  msgstr "Excessive errors from a bus, memory or IO.  Refer to %s for more information."
 436  436  msgid "INTEL-8000-T3.response"
 437  437  msgstr "No automated response action is possible"
 438  438  msgid "INTEL-8000-T3.impact"
 439  439  msgstr "System may panic or be reset by BIOS"
 440  440  msgid "INTEL-8000-T3.action"
 441  441  msgstr "Schedule a repair procedure to check seating of memory dimms. Schedule a repair procedure to check seating of io cards"
 442  442  #
 443  443  # code: INTEL-8000-UY
 444  444  # keys: fault.cpu.intel.bus_interconnect_memory
 445  445  #
 446  446  msgid "INTEL-8000-UY.type"
 447  447  msgstr "Fault"
 448  448  msgid "INTEL-8000-UY.severity"
 449  449  msgstr "Major"
 450  450  msgid "INTEL-8000-UY.description"
 451  451  msgstr "Excessive errors from memory accesses.  Refer to %s for more information."
 452  452  msgid "INTEL-8000-UY.response"
 453  453  msgstr "No automated response action is possible"
 454  454  msgid "INTEL-8000-UY.impact"
 455  455  msgstr "System may panic or be reset by BIOS"
 456  456  msgid "INTEL-8000-UY.action"
 457  457  msgstr "Schedule a repair procedure to reseat or replace memory dimms"
 458  458  #
 459  459  # code: INTEL-8000-V5
 460  460  # keys: fault.cpu.intel.bus_interconnect_io
 461  461  #
 462  462  msgid "INTEL-8000-V5.type"
 463  463  msgstr "Fault"
 464  464  msgid "INTEL-8000-V5.severity"
 465  465  msgstr "Major"
 466  466  msgid "INTEL-8000-V5.description"
 467  467  msgstr "Excessive errors from IO accesses.  Refer to %s for more information."
 468  468  msgid "INTEL-8000-V5.response"
 469  469  msgstr "No automated response action is possible"
 470  470  msgid "INTEL-8000-V5.impact"
 471  471  msgstr "System may panic or be reset by BIOS"
 472  472  msgid "INTEL-8000-V5.action"
 473  473  msgstr "Schedule a repair procedure to check seating of io cards"
 474  474  #
 475  475  # code: INTEL-8000-WS
 476  476  # keys: fault.cpu.intel.nb.fsb
 477  477  #
 478  478  msgid "INTEL-8000-WS.type"
 479  479  msgstr "Fault"
 480  480  msgid "INTEL-8000-WS.severity"
 481  481  msgstr "Critical"
 482  482  msgid "INTEL-8000-WS.description"
 483  483  msgstr "Front Side bus between CPU and northbridge  Refer to %s for more information."
 484  484  msgid "INTEL-8000-WS.response"
 485  485  msgstr "System panic or reset by BIOS"
 486  486  msgid "INTEL-8000-WS.impact"
 487  487  msgstr "System may panic or be reset by BIOS"
 488  488  msgid "INTEL-8000-WS.action"
 489  489  msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
 490  490  #
 491  491  # code: INTEL-8000-XA
 492  492  # keys: fault.memory.intel.fbd.berr
 493  493  #
 494  494  msgid "INTEL-8000-XA.type"
 495  495  msgstr "Fault"
 496  496  msgid "INTEL-8000-XA.severity"
 497  497  msgstr "Major"
 498  498  msgid "INTEL-8000-XA.description"
 499  499  msgstr "A fault occurred on a memory dimm channel  Refer to %s for more information."
 500  500  msgid "INTEL-8000-XA.response"
 501  501  msgstr "System panic or reset by BIOS"
 502  502  msgid "INTEL-8000-XA.impact"
 503  503  msgstr "System may not boot"
 504  504  msgid "INTEL-8000-XA.action"
 505  505  msgstr "reseat or replace dimms on channel.  Use 'fmadm faulty' to identify the channel."
 506  506  #
 507  507  # code: INTEL-8000-YP
 508  508  # keys: fault.memory.intel.fbd.alert
 509  509  #
 510  510  msgid "INTEL-8000-YP.type"
 511  511  msgstr "Fault"
 512  512  msgid "INTEL-8000-YP.severity"
 513  513  msgstr "Critical"
 514  514  msgid "INTEL-8000-YP.description"
 515  515  msgstr "Memory Controller detected a corrupted acknowledgment on a retry of a non-redundant memory write or configuration write  Refer to %s for more information."
 516  516  msgid "INTEL-8000-YP.response"
 517  517  msgstr "System panic or reset by BIOS"
 518  518  msgid "INTEL-8000-YP.impact"
 519  519  msgstr "System may be unexpectedly reset"
 520  520  msgid "INTEL-8000-YP.action"
 521  521  msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimm."
 522  522  #
 523  523  # code: INTEL-8001-0A
 524  524  # keys: fault.memory.intel.fbd.crc
 525  525  #
 526  526  msgid "INTEL-8001-0A.type"
 527  527  msgstr "Fault"
 528  528  msgid "INTEL-8001-0A.severity"
 529  529  msgstr "Critical"
 530  530  msgid "INTEL-8001-0A.description"
 531  531  msgstr "Memory Controller detected a corrupted CRC error on a non-redundant retry of memory or dimm configuration read.  Refer to %s for more information."
 532  532  msgid "INTEL-8001-0A.response"
 533  533  msgstr "System panic or reset by BIOS"
 534  534  msgid "INTEL-8001-0A.impact"
 535  535  msgstr "System may not boot"
 536  536  msgid "INTEL-8001-0A.action"
 537  537  msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimm."
 538  538  #
 539  539  # code: INTEL-8001-1P
 540  540  # keys: fault.memory.intel.fbd.ch
 541  541  #
 542  542  msgid "INTEL-8001-1P.type"
 543  543  msgstr "Fault"
 544  544  msgid "INTEL-8001-1P.severity"
 545  545  msgstr "Major"
 546  546  msgid "INTEL-8001-1P.description"
 547  547  msgstr "Memory Controller detected a corrupted CRC error on a non-redundant retry of memory or dimm configuration read  Refer to %s for more information."
 548  548  msgid "INTEL-8001-1P.response"
 549  549  msgstr "Hardware redundancy or correction of memory errors may be lost"
 550  550  msgid "INTEL-8001-1P.impact"
 551  551  msgstr "There may be a loss of hardware redundancy or performance"
 552  552  msgid "INTEL-8001-1P.action"
 553  553  msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimm."
 554  554  #
 555  555  # code: INTEL-8001-25
 556  556  # keys: fault.memory.intel.fbd.reset_timeout
 557  557  #
 558  558  msgid "INTEL-8001-25.type"
 559  559  msgstr "Fault"
 560  560  msgid "INTEL-8001-25.severity"
 561  561  msgstr "Critical"
 562  562  msgid "INTEL-8001-25.description"
 563  563  msgstr "Memory Controller detected fast reset timeout while trying to recover from read or write  Refer to %s for more information."
 564  564  msgid "INTEL-8001-25.response"
 565  565  msgstr "System panic or reset by BIOS"
 566  566  msgid "INTEL-8001-25.impact"
 567  567  msgstr "System may not boot"
 568  568  msgid "INTEL-8001-25.action"
 569  569  msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimms."
 570  570  #
 571  571  # code: INTEL-8001-3S
 572  572  # keys: fault.memory.intel.fbd.otf
 573  573  #
 574  574  msgid "INTEL-8001-3S.type"
 575  575  msgstr "Fault"
 576  576  msgid "INTEL-8001-3S.severity"
 577  577  msgstr "Major"
 578  578  msgid "INTEL-8001-3S.description"
 579  579  msgstr "Intelligent throttling is disabled in the memory controller and the thermal sensor detected over temperature  Refer to %s for more information."
 580  580  msgid "INTEL-8001-3S.response"
 581  581  msgstr "System panic or reset by BIOS"
 582  582  msgid "INTEL-8001-3S.impact"
 583  583  msgstr "System may be unexpectedly reset"
 584  584  msgid "INTEL-8001-3S.action"
 585  585  msgstr "Enable intelligent throttling in BIOS or supply more cooling"
 586  586  #
 587  587  # code: INTEL-8001-43
 588  588  # keys: fault.cpu.intel.nb.ie
 589  589  #
 590  590  msgid "INTEL-8001-43.type"
 591  591  msgstr "Fault"
 592  592  msgid "INTEL-8001-43.severity"
 593  593  msgstr "Critical"
 594  594  msgid "INTEL-8001-43.description"
 595  595  msgstr "Northbridge has detected an internal error  Refer to %s for more information."
 596  596  msgid "INTEL-8001-43.response"
 597  597  msgstr "System panic or reset by BIOS"
 598  598  msgid "INTEL-8001-43.impact"
 599  599  msgstr "System may be unexpectedly reset"
 600  600  msgid "INTEL-8001-43.action"
 601  601  msgstr "Replace motherboard"
 602  602  #
 603  603  # code: INTEL-8001-5Y
 604  604  # keys: fault.cpu.intel.nb.dma
 605  605  #
 606  606  msgid "INTEL-8001-5Y.type"
 607  607  msgstr "Fault"
 608  608  msgid "INTEL-8001-5Y.severity"
 609  609  msgstr "Major"
 610  610  msgid "INTEL-8001-5Y.description"
 611  611  msgstr "Northbridge dma controller has detected an error  Refer to %s for more information."
 612  612  msgid "INTEL-8001-5Y.response"
 613  613  msgstr "System panic or reset by BIOS"
 614  614  msgid "INTEL-8001-5Y.impact"
 615  615  msgstr "System may be unexpectedly reset"
 616  616  msgid "INTEL-8001-5Y.action"
 617  617  msgstr "Replace motherboard"
 618  618  #
 619  619  # code: INTEL-8001-6D
 620  620  # keys: fault.memory.intel.fbd.mem_ds
 621  621  #
 622  622  msgid "INTEL-8001-6D.type"
 623  623  msgstr "Fault"
 624  624  msgid "INTEL-8001-6D.severity"
 625  625  msgstr "Major"
 626  626  msgid "INTEL-8001-6D.description"
 627  627  msgstr "The memory controller has deployed the spare dimm rank to replace a rank which has had too many errors  Refer to %s for more information."
 628  628  msgid "INTEL-8001-6D.response"
 629  629  msgstr "There is no spare rank for this memory controller"
 630  630  msgid "INTEL-8001-6D.impact"
 631  631  msgstr "There is a loss of hardware redundancy"
 632  632  msgid "INTEL-8001-6D.action"
 633  633  msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm."
 634  634  #
  
    | 
      ↓ open down ↓ | 
    634 lines elided | 
    
      ↑ open up ↑ | 
  
 635  635  # code: INTEL-8001-7H
 636  636  # keys: fault.memory.intel.page_ce
 637  637  #
 638  638  msgid "INTEL-8001-7H.type"
 639  639  msgstr "Fault"
 640  640  msgid "INTEL-8001-7H.severity"
 641  641  msgstr "Minor"
 642  642  msgid "INTEL-8001-7H.description"
 643  643  msgstr "A page of memory has reported excessive correctable ECC errors.  Refer to %s for more information."
 644  644  msgid "INTEL-8001-7H.response"
 645      -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
      645 +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
 646  646  msgid "INTEL-8001-7H.impact"
 647  647  msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
 648  648  msgid "INTEL-8001-7H.action"
 649  649  msgstr "No repair action is recommended at this time."
 650  650  #
 651  651  # code: INTEL-8001-8R
 652  652  # keys: fault.memory.intel.page_ue
 653  653  #
 654  654  msgid "INTEL-8001-8R.type"
 655  655  msgstr "Fault"
 656  656  msgid "INTEL-8001-8R.severity"
 657  657  msgstr "Major"
 658  658  msgid "INTEL-8001-8R.description"
 659  659  msgstr "A page of memory has encountered an uncorrectable multiple-bit error. This fault class is an internal implementation peculiarity and can be ignored by system administrators; action is only necessary if it is followed by a related dimm fault diagnosis (as should always be the case for uncorrectable errors).  Refer to %s for more information."
 660  660  msgid "INTEL-8001-8R.response"
 661      -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
      661 +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
 662  662  msgid "INTEL-8001-8R.impact"
 663  663  msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
 664  664  msgid "INTEL-8001-8R.action"
 665  665  msgstr "No repair action is recommended at this time."
 666  666  #
 667  667  # code: INTEL-8001-94
 668  668  # keys: fault.memory.intel.dimm_ce
 669  669  #
 670  670  msgid "INTEL-8001-94.type"
 671  671  msgstr "Fault"
 672  672  msgid "INTEL-8001-94.severity"
 673  673  msgstr "Major"
 674  674  msgid "INTEL-8001-94.description"
 675  675  msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
 676  676  msgid "INTEL-8001-94.response"
 677  677  msgstr "Pages of memory associated with this memory module may have been removed from service, up to a limit which has now been reached."
 678  678  msgid "INTEL-8001-94.impact"
 679  679  msgstr "Total system memory capacity has been reduced (where supported)."
 680  680  msgid "INTEL-8001-94.action"
 681  681  msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
 682  682  #
  
    | 
      ↓ open down ↓ | 
    11 lines elided | 
    
      ↑ open up ↑ | 
  
 683  683  # code: INTEL-8001-AQ
 684  684  # keys: fault.memory.intel.dimm_ue
 685  685  #
 686  686  msgid "INTEL-8001-AQ.type"
 687  687  msgstr "Fault"
 688  688  msgid "INTEL-8001-AQ.severity"
 689  689  msgstr "Critical"
 690  690  msgid "INTEL-8001-AQ.description"
 691  691  msgstr "A memory module has experienced an uncorrectable multiple-bit error.  Refer to %s for more information."
 692  692  msgid "INTEL-8001-AQ.response"
 693      -msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n"
      693 +msgstr "\n\nIf illumos is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n"
 694  694  msgid "INTEL-8001-AQ.impact"
 695  695  msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n"
 696  696  msgid "INTEL-8001-AQ.action"
 697  697  msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm -u ' to identify the module."
 698  698  #
 699  699  # code: INTEL-8001-CC
 700  700  # keys: fault.cpu.intel.nb.otf
 701  701  #
 702  702  msgid "INTEL-8001-CC.type"
 703  703  msgstr "Fault"
 704  704  msgid "INTEL-8001-CC.severity"
 705  705  msgstr "Major"
 706  706  msgid "INTEL-8001-CC.description"
 707  707  msgstr "Northbridge detected over temperature  Refer to %s for more information."
 708  708  msgid "INTEL-8001-CC.response"
 709  709  msgstr "System panic or reset by BIOS"
 710  710  msgid "INTEL-8001-CC.impact"
 711  711  msgstr "System may be unexpectedly reset"
 712  712  msgid "INTEL-8001-CC.action"
 713  713  msgstr "Supply more cooling"
 714  714  #
 715  715  # code: INTEL-8001-DJ
 716  716  # keys: fault.cpu.intel.quickpath.mem_parity
 717  717  #
 718  718  msgid "INTEL-8001-DJ.type"
 719  719  msgstr "Fault"
 720  720  msgid "INTEL-8001-DJ.severity"
 721  721  msgstr "Major"
 722  722  msgid "INTEL-8001-DJ.description"
 723  723  msgstr "Bad parity detected in memory write buffer or byte mask.  Refer to %s for more information."
 724  724  msgid "INTEL-8001-DJ.response"
 725  725  msgstr "System panic or reset by BIOS"
 726  726  msgid "INTEL-8001-DJ.impact"
 727  727  msgstr "System may panic or be reset by BIOS"
 728  728  msgid "INTEL-8001-DJ.action"
 729  729  msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
 730  730  #
 731  731  # code: INTEL-8001-EE
 732  732  # keys: fault.cpu.intel.quickpath.mem_addr_parity
 733  733  #
 734  734  msgid "INTEL-8001-EE.type"
 735  735  msgstr "Fault"
 736  736  msgid "INTEL-8001-EE.severity"
 737  737  msgstr "Major"
 738  738  msgid "INTEL-8001-EE.description"
 739  739  msgstr "Bad parity detected in memory address within controller.  Refer to %s for more information."
 740  740  msgid "INTEL-8001-EE.response"
 741  741  msgstr "System panic or reset by BIOS"
 742  742  msgid "INTEL-8001-EE.impact"
 743  743  msgstr "System may panic or be reset by BIOS"
 744  744  msgid "INTEL-8001-EE.action"
 745  745  msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
 746  746  #
 747  747  # code: INTEL-8001-FX
 748  748  # keys: fault.cpu.intel.quickpath.mem_bad_addr
 749  749  #
 750  750  msgid "INTEL-8001-FX.type"
 751  751  msgstr "Fault"
 752  752  msgid "INTEL-8001-FX.severity"
 753  753  msgstr "Major"
 754  754  msgid "INTEL-8001-FX.description"
 755  755  msgstr "Memory address is outside range mapped to memory dimms.  Refer to %s for more information."
 756  756  msgid "INTEL-8001-FX.response"
 757  757  msgstr "System panic or reset by BIOS"
 758  758  msgid "INTEL-8001-FX.impact"
 759  759  msgstr "System may panic or be reset by BIOS"
 760  760  msgid "INTEL-8001-FX.action"
 761  761  msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
 762  762  #
 763  763  # code: INTEL-8001-G2
 764  764  # keys: fault.cpu.intel.quickpath.mem_spare
 765  765  #
 766  766  msgid "INTEL-8001-G2.type"
 767  767  msgstr "Fault"
 768  768  msgid "INTEL-8001-G2.severity"
 769  769  msgstr "Major"
 770  770  msgid "INTEL-8001-G2.description"
 771  771  msgstr "A fatal error occured while trying to deploy spare memory.  Refer to %s for more information."
 772  772  msgid "INTEL-8001-G2.response"
 773  773  msgstr "System panic or reset by BIOS"
 774  774  msgid "INTEL-8001-G2.impact"
 775  775  msgstr "System may panic or be reset by BIOS"
 776  776  msgid "INTEL-8001-G2.action"
 777  777  msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm."
 778  778  #
 779  779  # code: INTEL-8001-HS
 780  780  # keys: fault.cpu.intel.quickpath.mem_bad_id
 781  781  #
 782  782  msgid "INTEL-8001-HS.type"
 783  783  msgstr "Fault"
 784  784  msgid "INTEL-8001-HS.severity"
 785  785  msgstr "Major"
 786  786  msgid "INTEL-8001-HS.description"
 787  787  msgstr "Memory controller received bad transaction tracker ID from interconnect.  Refer to %s for more information."
 788  788  msgid "INTEL-8001-HS.response"
 789  789  msgstr "System panic or reset by BIOS"
 790  790  msgid "INTEL-8001-HS.impact"
 791  791  msgstr "System may panic or be reset by BIOS"
 792  792  msgid "INTEL-8001-HS.action"
 793  793  msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
 794  794  #
 795  795  # code: INTEL-8001-J5
 796  796  # keys: fault.cpu.intel.quickpath.mem_redundant
 797  797  #
 798  798  msgid "INTEL-8001-J5.type"
 799  799  msgstr "Fault"
 800  800  msgid "INTEL-8001-J5.severity"
 801  801  msgstr "Minor"
 802  802  msgid "INTEL-8001-J5.description"
 803  803  msgstr "Memory Mirroring lost due to error.  Refer to %s for more information."
 804  804  msgid "INTEL-8001-J5.response"
 805  805  msgstr "There is no spare copy of memory"
 806  806  msgid "INTEL-8001-J5.impact"
 807  807  msgstr "There is a loss of hardware redundancy"
 808  808  msgid "INTEL-8001-J5.action"
 809  809  msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm."
 810  810  #
 811  811  # code: INTEL-8001-KP
 812  812  # keys: fault.cpu.intel.quickpath.interconnect
 813  813  #
 814  814  msgid "INTEL-8001-KP.type"
 815  815  msgstr "Fault"
 816  816  msgid "INTEL-8001-KP.severity"
 817  817  msgstr "Major"
 818  818  msgid "INTEL-8001-KP.description"
 819  819  msgstr "Quickpath Deteced Error.  Refer to %s for more information."
 820  820  msgid "INTEL-8001-KP.response"
 821  821  msgstr "System panic or reset by BIOS"
 822  822  msgid "INTEL-8001-KP.impact"
 823  823  msgstr "System may panic or be reset by BIOS"
 824  824  msgid "INTEL-8001-KP.action"
 825  825  msgstr "Schedule a repair procedure to check seating of proccessors"
 826  826  #
 827  827  # code: INTEL-8001-LA
 828  828  # keys: fault.cpu.intel.quickpath.mem_controller_ce
 829  829  #
 830  830  msgid "INTEL-8001-LA.type"
 831  831  msgstr "Fault"
 832  832  msgid "INTEL-8001-LA.severity"
 833  833  msgstr "Major"
 834  834  msgid "INTEL-8001-LA.description"
 835  835  msgstr "A quickpath memory controller correctable error was detected.  Refer to %s for more information."
 836  836  msgid "INTEL-8001-LA.response"
 837  837  msgstr "Processor is not off-lined, as the memory controller on the CPU chip is still accessible by other processors"
 838  838  msgid "INTEL-8001-LA.impact"
 839  839  msgstr "No impact to the system in the presence of this fault."
 840  840  msgid "INTEL-8001-LA.action"
 841  841  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 842  842  #
 843  843  # code: INTEL-8001-MH
 844  844  # keys: fault.cpu.intel.quickpath.mem_controller_ue
 845  845  #
 846  846  msgid "INTEL-8001-MH.type"
 847  847  msgstr "Fault"
 848  848  msgid "INTEL-8001-MH.severity"
 849  849  msgstr "Critical"
 850  850  msgid "INTEL-8001-MH.description"
 851  851  msgstr "A quickpath memory controller uncorrectable error was detected.  Refer to %s for more information."
 852  852  msgid "INTEL-8001-MH.response"
 853  853  msgstr "Processor is not off-lined, as the memory controller on the CPU chip is still accessible by other processors"
 854  854  msgid "INTEL-8001-MH.impact"
 855  855  msgstr "System may panic or be reset by BIOS."
 856  856  msgid "INTEL-8001-MH.action"
 857  857  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 858  858  #
 859  859  # code: INTEL-8001-ND
 860  860  # keys: fault.cpu.intel.quickpath.mem_link_ce
 861  861  #
 862  862  msgid "INTEL-8001-ND.type"
 863  863  msgstr "Fault"
 864  864  msgid "INTEL-8001-ND.severity"
 865  865  msgstr "Major"
 866  866  msgid "INTEL-8001-ND.description"
 867  867  msgstr "A quickpath memory link correctable error was detected.  Refer to %s for more information."
 868  868  msgid "INTEL-8001-ND.response"
 869  869  msgstr "Processor is not off-lined, as the memory controller on the CPU chip is still accessible by other processors"
 870  870  msgid "INTEL-8001-ND.impact"
 871  871  msgstr "No impact to the system in the presence of this fault."
 872  872  msgid "INTEL-8001-ND.action"
 873  873  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 874  874  #
 875  875  # code: INTEL-8001-PY
 876  876  # keys: fault.cpu.intel.quickpath.mem_link_ue
 877  877  #
 878  878  msgid "INTEL-8001-PY.type"
 879  879  msgstr "Fault"
 880  880  msgid "INTEL-8001-PY.severity"
 881  881  msgstr "Critical"
 882  882  msgid "INTEL-8001-PY.description"
 883  883  msgstr "A quickpath memory link uncorrectable error was detected.  Refer to %s for more information."
 884  884  msgid "INTEL-8001-PY.response"
 885  885  msgstr "Processor is not off-lined, as the memory controller on the CPU chip is still accessible by other processors"
 886  886  msgid "INTEL-8001-PY.impact"
 887  887  msgstr "System may panic or be reset by BIOS."
 888  888  msgid "INTEL-8001-PY.action"
 889  889  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 890  890  #
 891  891  # code: INTEL-8001-Q3
 892  892  # keys: fault.cpu.intel.quickpath.mem_failover_mir
 893  893  #
 894  894  msgid "INTEL-8001-Q3.type"
 895  895  msgstr "Fault"
 896  896  msgid "INTEL-8001-Q3.severity"
 897  897  msgstr "Major"
 898  898  msgid "INTEL-8001-Q3.description"
 899  899  msgstr "Uncorrectable error on the memory controller.  Refer to %s for more information."
 900  900  msgid "INTEL-8001-Q3.response"
 901  901  msgstr "None"
 902  902  msgid "INTEL-8001-Q3.impact"
 903  903  msgstr "System will continue to run, but a loss of memory mirror capability."
 904  904  msgid "INTEL-8001-Q3.action"
 905  905  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 906  906  #
 907  907  # code: INTEL-8001-RC
 908  908  # keys: fault.cpu.intel.quickpath.mem_scrubbing
 909  909  #
 910  910  msgid "INTEL-8001-RC.type"
 911  911  msgstr "Fault"
 912  912  msgid "INTEL-8001-RC.severity"
 913  913  msgstr "Minor"
 914  914  msgid "INTEL-8001-RC.description"
 915  915  msgstr "An uncorrectable software recoverable memory scrubbing error has occurred.  Refer to %s for more information."
 916  916  msgid "INTEL-8001-RC.response"
 917  917  msgstr "A pair of pages on two different DIMM's will be retired."
 918  918  msgid "INTEL-8001-RC.impact"
 919  919  msgstr "No impact to the system in the presence of this fault."
 920  920  msgid "INTEL-8001-RC.action"
 921  921  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 922  922  #
 923  923  # code: INTEL-8001-SQ
 924  924  # keys: fault.cpu.intel.quickpath.llc_ewb
 925  925  #
 926  926  msgid "INTEL-8001-SQ.type"
 927  927  msgstr "Fault"
 928  928  msgid "INTEL-8001-SQ.severity"
 929  929  msgstr "Minor"
 930  930  msgid "INTEL-8001-SQ.description"
 931  931  msgstr "An uncorrectable LLC explicit writeback error has occurred.  Refer to %s for more information."
 932  932  msgid "INTEL-8001-SQ.response"
 933  933  msgstr "Page is retired, however the page will be unretired upon next reboot."
 934  934  msgid "INTEL-8001-SQ.impact"
 935  935  msgstr "No impact to the system in the presence of this fault."
 936  936  msgid "INTEL-8001-SQ.action"
 937  937  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 938  938  #
 939  939  # code: INTEL-8001-T4
 940  940  # keys: fault.cpu.intel.quickpath.home_agent
 941  941  #
 942  942  msgid "INTEL-8001-T4.type"
 943  943  msgstr "Fault"
 944  944  msgid "INTEL-8001-T4.severity"
 945  945  msgstr "Critical"
 946  946  msgid "INTEL-8001-T4.description"
 947  947  msgstr "A home agent and global coherence engine error has occurred.  Refer to %s for more information."
 948  948  msgid "INTEL-8001-T4.response"
 949  949  msgstr "None"
 950  950  msgid "INTEL-8001-T4.impact"
 951  951  msgstr "System will be reset upon fatal event or may continue to run when an uncorrectable event."
 952  952  msgid "INTEL-8001-T4.action"
 953  953  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 954  954  #
 955  955  # code: INTEL-8001-UR
 956  956  # keys: fault.cpu.intel.quickpath.sys_cfg
 957  957  #
 958  958  msgid "INTEL-8001-UR.type"
 959  959  msgstr "Fault"
 960  960  msgid "INTEL-8001-UR.severity"
 961  961  msgstr "Critical"
 962  962  msgid "INTEL-8001-UR.description"
 963  963  msgstr "A system configuration controller error has occurred.  Refer to %s for more information."
 964  964  msgid "INTEL-8001-UR.response"
 965  965  msgstr "None"
 966  966  msgid "INTEL-8001-UR.impact"
 967  967  msgstr "System will be reset upon fatal event or may continue to run when an uncorrectable event."
 968  968  msgid "INTEL-8001-UR.action"
 969  969  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 970  970  #
 971  971  # code: INTEL-8001-V2
 972  972  # keys: fault.cpu.intel.quickpath.system_cache
 973  973  #
 974  974  msgid "INTEL-8001-V2.type"
 975  975  msgstr "Fault"
 976  976  msgid "INTEL-8001-V2.severity"
 977  977  msgstr "Critical"
 978  978  msgid "INTEL-8001-V2.description"
 979  979  msgstr "A system caching agent error has occurred.  Refer to %s for more information."
 980  980  msgid "INTEL-8001-V2.response"
 981  981  msgstr "None"
 982  982  msgid "INTEL-8001-V2.impact"
 983  983  msgstr "System will be reset upon fatal event or may continue to run when an uncorrectable event."
 984  984  msgid "INTEL-8001-V2.action"
 985  985  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
 986  986  #
 987  987  # code: INTEL-8001-WX
 988  988  # keys: fault.cpu.intel.quickpath.bus_interconnect
 989  989  #
 990  990  msgid "INTEL-8001-WX.type"
 991  991  msgstr "Fault"
 992  992  msgid "INTEL-8001-WX.severity"
 993  993  msgstr "Critical"
 994  994  msgid "INTEL-8001-WX.description"
 995  995  msgstr "A quickpath internal port error was detected.  Refer to %s for more information."
 996  996  msgid "INTEL-8001-WX.response"
 997  997  msgstr "None"
 998  998  msgid "INTEL-8001-WX.impact"
 999  999  msgstr "System may panic, maybe reset by the BIOS, or may continue to run."
1000 1000  msgid "INTEL-8001-WX.action"
1001 1001  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
1002 1002  #
1003 1003  # code: INTEL-8001-XE
1004 1004  # keys: fault.cpu.intel.has_poison
1005 1005  #
1006 1006  msgid "INTEL-8001-XE.type"
1007 1007  msgstr "Fault"
1008 1008  msgid "INTEL-8001-XE.severity"
1009 1009  msgstr "Minor"
1010 1010  msgid "INTEL-8001-XE.description"
1011 1011  msgstr "Cache line has been poisoned to protect integrity.  Refer to %s for more information."
1012 1012  msgid "INTEL-8001-XE.response"
1013 1013  msgstr "None"
1014 1014  msgid "INTEL-8001-XE.impact"
1015 1015  msgstr "No impact to the system in the presence of this fault."
1016 1016  msgid "INTEL-8001-XE.action"
1017 1017  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
1018 1018  #
1019 1019  # code: INTEL-8001-YJ
1020 1020  # keys: fault.cpu.intel.discard_fatal
1021 1021  #
1022 1022  msgid "INTEL-8001-YJ.type"
1023 1023  msgstr "Fault"
1024 1024  msgid "INTEL-8001-YJ.severity"
1025 1025  msgstr "Minor"
1026 1026  msgid "INTEL-8001-YJ.description"
1027 1027  msgstr "Discarding cache line to protect data integrity.  Refer to %s for more information."
1028 1028  msgid "INTEL-8001-YJ.response"
1029 1029  msgstr "None"
1030 1030  msgid "INTEL-8001-YJ.impact"
1031 1031  msgstr "No impact to the system in the presence of this fault."
1032 1032  msgid "INTEL-8001-YJ.action"
1033 1033  msgstr "Please refer to the 'Details' section of the knowledge article for the latest service procedures and policies for resolving this issue."
  
    | 
      ↓ open down ↓ | 
    330 lines elided | 
    
      ↑ open up ↑ | 
  