*** 640,650 ****
  msgid "INTEL-8001-7H.severity"
  msgstr "Minor"
  msgid "INTEL-8001-7H.description"
  msgstr "A page of memory has reported excessive correctable ECC errors.  Refer to %s for more information."
  msgid "INTEL-8001-7H.response"
! msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
  msgid "INTEL-8001-7H.impact"
  msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
  msgid "INTEL-8001-7H.action"
  msgstr "No repair action is recommended at this time."
  #
--- 640,650 ----
  msgid "INTEL-8001-7H.severity"
  msgstr "Minor"
  msgid "INTEL-8001-7H.description"
  msgstr "A page of memory has reported excessive correctable ECC errors.  Refer to %s for more information."
  msgid "INTEL-8001-7H.response"
! msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
  msgid "INTEL-8001-7H.impact"
  msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
  msgid "INTEL-8001-7H.action"
  msgstr "No repair action is recommended at this time."
  #
*** 656,666 ****
  msgid "INTEL-8001-8R.severity"
  msgstr "Major"
  msgid "INTEL-8001-8R.description"
  msgstr "A page of memory has encountered an uncorrectable multiple-bit error. This fault class is an internal implementation peculiarity and can be ignored by system administrators; action is only necessary if it is followed by a related dimm fault diagnosis (as should always be the case for uncorrectable errors).  Refer to %s for more information."
  msgid "INTEL-8001-8R.response"
! msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
  msgid "INTEL-8001-8R.impact"
  msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
  msgid "INTEL-8001-8R.action"
  msgstr "No repair action is recommended at this time."
  #
--- 656,666 ----
  msgid "INTEL-8001-8R.severity"
  msgstr "Major"
  msgid "INTEL-8001-8R.description"
  msgstr "A page of memory has encountered an uncorrectable multiple-bit error. This fault class is an internal implementation peculiarity and can be ignored by system administrators; action is only necessary if it is followed by a related dimm fault diagnosis (as should always be the case for uncorrectable errors).  Refer to %s for more information."
  msgid "INTEL-8001-8R.response"
! msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
  msgid "INTEL-8001-8R.impact"
  msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
  msgid "INTEL-8001-8R.action"
  msgstr "No repair action is recommended at this time."
  #
*** 688,698 ****
  msgid "INTEL-8001-AQ.severity"
  msgstr "Critical"
  msgid "INTEL-8001-AQ.description"
  msgstr "A memory module has experienced an uncorrectable multiple-bit error.  Refer to %s for more information."
  msgid "INTEL-8001-AQ.response"
! msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n"
  msgid "INTEL-8001-AQ.impact"
  msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n"
  msgid "INTEL-8001-AQ.action"
  msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm -u ' to identify the module."
  #
--- 688,698 ----
  msgid "INTEL-8001-AQ.severity"
  msgstr "Critical"
  msgid "INTEL-8001-AQ.description"
  msgstr "A memory module has experienced an uncorrectable multiple-bit error.  Refer to %s for more information."
  msgid "INTEL-8001-AQ.response"
! msgstr "\n\nIf illumos is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n"
  msgid "INTEL-8001-AQ.impact"
  msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n"
  msgid "INTEL-8001-AQ.action"
  msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm -u ' to identify the module."
  #