Print this page
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
| Split |
Close |
| Expand all |
| Collapse all |
--- old/usr/src/cmd/fm/dicts/FMD.po
+++ new/usr/src/cmd/fm/dicts/FMD.po
1 1 #
2 2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
3 3 #
4 4 # CDDL HEADER START
5 5 #
6 6 # The contents of this file are subject to the terms of the
7 7 # Common Development and Distribution License (the "License").
8 8 # You may not use this file except in compliance with the License.
9 9 #
10 10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11 11 # or http://www.opensolaris.org/os/licensing.
12 12 # See the License for the specific language governing permissions
13 13 # and limitations under the License.
14 14 #
15 15 # When distributing Covered Code, include this CDDL HEADER in each
16 16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17 17 # If applicable, add the following below this CDDL HEADER, with the
18 18 # fields enclosed by brackets "[]" replaced with your own identifying
19 19 # information: Portions Copyright [yyyy] [name of copyright owner]
20 20 #
21 21 # CDDL HEADER END
22 22 #
23 23
24 24 # DO NOT EDIT -- this file is generated by the Event Registry.
25 25 #
26 26 #
27 27 # General-purpose messages
28 28 #
29 29 msgid "syslog-msgs-message-template"
30 30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
31 31 #
32 32 # Fault-related messages
33 33 #
|
↓ open down ↓ |
33 lines elided |
↑ open up ↑ |
34 34 #
35 35 #
36 36 # code: FMD-8000-0W
37 37 # keys: defect.sunos.fmd.nosub
38 38 #
39 39 msgid "FMD-8000-0W.type"
40 40 msgstr "Defect"
41 41 msgid "FMD-8000-0W.severity"
42 42 msgstr "Minor"
43 43 msgid "FMD-8000-0W.description"
44 -msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information."
44 +msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information."
45 45 msgid "FMD-8000-0W.response"
46 -msgstr "Error reports from the component will be logged for examination by Sun."
46 +msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
47 47 msgid "FMD-8000-0W.impact"
48 48 msgstr "Automated diagnosis and response for these events will not occur."
49 49 msgid "FMD-8000-0W.action"
50 -msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support."
50 +msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
51 51 #
52 52 # code: FMD-8000-11
53 53 # keys: defect.sunos.fmd.nodiagcode
54 54 #
55 55 msgid "FMD-8000-11.type"
56 56 msgstr "Defect"
57 57 msgid "FMD-8000-11.severity"
58 58 msgstr "Minor"
59 59 msgid "FMD-8000-11.description"
60 -msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information."
60 +msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information."
61 61 msgid "FMD-8000-11.response"
62 -msgstr "The diagnosis has been saved in the fault log for examination by Sun."
62 +msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team."
63 63 msgid "FMD-8000-11.impact"
64 64 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
65 65 msgid "FMD-8000-11.action"
66 -msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
66 +msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Ensure that fault management software is installed properly."
67 67 #
68 68 # code: FMD-8000-2K
69 69 # keys: defect.sunos.fmd.module
70 70 #
71 71 msgid "FMD-8000-2K.type"
72 72 msgstr "Defect"
73 73 msgid "FMD-8000-2K.severity"
74 74 msgstr "Minor"
75 75 msgid "FMD-8000-2K.description"
76 -msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information."
76 +msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information."
77 77 msgid "FMD-8000-2K.response"
78 78 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis."
79 79 msgid "FMD-8000-2K.impact"
80 80 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
81 81 msgid "FMD-8000-2K.action"
82 82 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module."
83 83 #
84 84 # code: FMD-8000-3F
85 85 # keys: defect.sunos.fmd.config
86 86 #
87 87 msgid "FMD-8000-3F.type"
88 88 msgstr "Defect"
89 89 msgid "FMD-8000-3F.severity"
90 90 msgstr "Minor"
91 91 msgid "FMD-8000-3F.description"
92 -msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information."
92 +msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information."
93 93 msgid "FMD-8000-3F.response"
94 94 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis."
95 95 msgid "FMD-8000-3F.impact"
96 96 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
97 97 msgid "FMD-8000-3F.action"
98 98 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration."
99 99 #
100 100 # code: FMD-8000-4M
101 101 # keys: list.repaired
102 102 #
103 103 msgid "FMD-8000-4M.type"
104 104 msgstr "Repair"
105 105 msgid "FMD-8000-4M.severity"
106 106 msgstr "Minor"
107 107 msgid "FMD-8000-4M.description"
108 108 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information."
109 109 msgid "FMD-8000-4M.response"
110 110 msgstr "Some system components offlined because of the original fault may have been brought back online."
111 111 msgid "FMD-8000-4M.impact"
112 112 msgstr "Performance degradation of the system due to the original fault may have been recovered."
113 113 msgid "FMD-8000-4M.action"
114 114 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
115 115 #
116 116 # code: FMD-8000-58
117 117 # keys: list.updated
118 118 #
119 119 msgid "FMD-8000-58.type"
120 120 msgstr "Update"
121 121 msgid "FMD-8000-58.severity"
122 122 msgstr "Minor"
123 123 msgid "FMD-8000-58.description"
124 124 msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information."
125 125 msgid "FMD-8000-58.response"
126 126 msgstr "Some system components offlined because of the original fault may have been brought back online."
127 127 msgid "FMD-8000-58.impact"
128 128 msgstr "Performance degradation of the system due to the original fault may have been recovered."
129 129 msgid "FMD-8000-58.action"
130 130 msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
131 131 #
132 132 # code: FMD-8000-6U
133 133 # keys: list.resolved
134 134 #
135 135 msgid "FMD-8000-6U.type"
136 136 msgstr "Resolved"
137 137 msgid "FMD-8000-6U.severity"
138 138 msgstr "Minor"
139 139 msgid "FMD-8000-6U.description"
140 140 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information."
141 141 msgid "FMD-8000-6U.response"
142 142 msgstr "All system components offlined because of the original fault have been brought back online."
143 143 msgid "FMD-8000-6U.impact"
144 144 msgstr "Performance degradation of the system due to the original fault has been recovered."
145 145 msgid "FMD-8000-6U.action"
146 146 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
|
↓ open down ↓ |
44 lines elided |
↑ open up ↑ |
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX