Print this page
    
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
    
      
        | Split | 
	Close | 
      
      | Expand all | 
      | Collapse all | 
    
    
          --- old/usr/src/cmd/fm/dicts/FMD.po
          +++ new/usr/src/cmd/fm/dicts/FMD.po
   1    1  #
   2    2  # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
   3    3  #
   4    4  # CDDL HEADER START
   5    5  #
   6    6  # The contents of this file are subject to the terms of the
   7    7  # Common Development and Distribution License (the "License").
   8    8  # You may not use this file except in compliance with the License.
   9    9  #
  10   10  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  11   11  # or http://www.opensolaris.org/os/licensing.
  12   12  # See the License for the specific language governing permissions
  13   13  # and limitations under the License.
  14   14  #
  15   15  # When distributing Covered Code, include this CDDL HEADER in each
  16   16  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  17   17  # If applicable, add the following below this CDDL HEADER, with the
  18   18  # fields enclosed by brackets "[]" replaced with your own identifying
  19   19  # information: Portions Copyright [yyyy] [name of copyright owner]
  20   20  #
  21   21  # CDDL HEADER END
  22   22  #
  23   23  
  24   24  # DO NOT EDIT -- this file is generated by the Event Registry.
  25   25  #
  26   26  #
  27   27  # General-purpose messages
  28   28  #
  29   29  msgid "syslog-msgs-message-template"
  30   30  msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
  31   31  #
  32   32  # Fault-related messages
  33   33  #
  
    | 
      ↓ open down ↓ | 
    33 lines elided | 
    
      ↑ open up ↑ | 
  
  34   34  #
  35   35  #
  36   36  # code: FMD-8000-0W
  37   37  # keys: defect.sunos.fmd.nosub
  38   38  #
  39   39  msgid "FMD-8000-0W.type"
  40   40  msgstr "Defect"
  41   41  msgid "FMD-8000-0W.severity"
  42   42  msgstr "Minor"
  43   43  msgid "FMD-8000-0W.description"
  44      -msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
       44 +msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
  45   45  msgid "FMD-8000-0W.response"
  46      -msgstr "Error reports from the component will be logged for examination by Sun."
       46 +msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
  47   47  msgid "FMD-8000-0W.impact"
  48   48  msgstr "Automated diagnosis and response for these events will not occur."
  49   49  msgid "FMD-8000-0W.action"
  50      -msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly.  Contact Sun for support."
       50 +msgstr "Ensure that fault management software is installed properly.  Contact your illumos distribution team for support."
  51   51  #
  52   52  # code: FMD-8000-11
  53   53  # keys: defect.sunos.fmd.nodiagcode
  54   54  #
  55   55  msgid "FMD-8000-11.type"
  56   56  msgstr "Defect"
  57   57  msgid "FMD-8000-11.severity"
  58   58  msgstr "Minor"
  59   59  msgid "FMD-8000-11.description"
  60      -msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
       60 +msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
  61   61  msgid "FMD-8000-11.response"
  62      -msgstr "The diagnosis has been saved in the fault log for examination by Sun."
       62 +msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team."
  63   63  msgid "FMD-8000-11.impact"
  64   64  msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
  65   65  msgid "FMD-8000-11.action"
  66      -msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
       66 +msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Ensure that fault management software is installed properly."
  67   67  #
  68   68  # code: FMD-8000-2K
  69   69  # keys: defect.sunos.fmd.module
  70   70  #
  71   71  msgid "FMD-8000-2K.type"
  72   72  msgstr "Defect"
  73   73  msgid "FMD-8000-2K.severity"
  74   74  msgstr "Minor"
  75   75  msgid "FMD-8000-2K.description"
  76      -msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
       76 +msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
  77   77  msgid "FMD-8000-2K.response"
  78   78  msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  79   79  msgid "FMD-8000-2K.impact"
  80   80  msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  81   81  msgid "FMD-8000-2K.action"
  82   82  msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
  83   83  #
  84   84  # code: FMD-8000-3F
  85   85  # keys: defect.sunos.fmd.config
  86   86  #
  87   87  msgid "FMD-8000-3F.type"
  88   88  msgstr "Defect"
  89   89  msgid "FMD-8000-3F.severity"
  90   90  msgstr "Minor"
  91   91  msgid "FMD-8000-3F.description"
  92      -msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
       92 +msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
  93   93  msgid "FMD-8000-3F.response"
  94   94  msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  95   95  msgid "FMD-8000-3F.impact"
  96   96  msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  97   97  msgid "FMD-8000-3F.action"
  98   98  msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
  99   99  #
 100  100  # code: FMD-8000-4M
 101  101  # keys: list.repaired
 102  102  #
 103  103  msgid "FMD-8000-4M.type"
 104  104  msgstr "Repair"
 105  105  msgid "FMD-8000-4M.severity"
 106  106  msgstr "Minor"
 107  107  msgid "FMD-8000-4M.description"
 108  108  msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
 109  109  msgid "FMD-8000-4M.response"
 110  110  msgstr "Some system components offlined because of the original fault may have been brought back online."
 111  111  msgid "FMD-8000-4M.impact"
 112  112  msgstr "Performance degradation of the system due to the original fault may have been recovered."
 113  113  msgid "FMD-8000-4M.action"
 114  114  msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
 115  115  #
 116  116  # code: FMD-8000-58
 117  117  # keys: list.updated
 118  118  #
 119  119  msgid "FMD-8000-58.type"
 120  120  msgstr "Update"
 121  121  msgid "FMD-8000-58.severity"
 122  122  msgstr "Minor"
 123  123  msgid "FMD-8000-58.description"
 124  124  msgstr "Some faults associated with an event id have been addressed.\n  Refer to %s for more information."
 125  125  msgid "FMD-8000-58.response"
 126  126  msgstr "Some system components offlined because of the original fault may have been brought back online."
 127  127  msgid "FMD-8000-58.impact"
 128  128  msgstr "Performance degradation of the system due to the original fault may have been recovered."
 129  129  msgid "FMD-8000-58.action"
 130  130  msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
 131  131  #
 132  132  # code: FMD-8000-6U
 133  133  # keys: list.resolved
 134  134  #
 135  135  msgid "FMD-8000-6U.type"
 136  136  msgstr "Resolved"
 137  137  msgid "FMD-8000-6U.severity"
 138  138  msgstr "Minor"
 139  139  msgid "FMD-8000-6U.description"
 140  140  msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
 141  141  msgid "FMD-8000-6U.response"
 142  142  msgstr "All system components offlined because of the original fault have been brought back online."
 143  143  msgid "FMD-8000-6U.impact"
 144  144  msgstr "Performance degradation of the system due to the original fault has been recovered."
 145  145  msgid "FMD-8000-6U.action"
 146  146  msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
  
    | 
      ↓ open down ↓ | 
    44 lines elided | 
    
      ↑ open up ↑ | 
  
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX