24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # General-purpose messages
  28 #
  29 msgid "syslog-msgs-message-template"
  30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
  31 #
  32 # Fault-related messages
  33 #
  34 #
  35 #
  36 # code: FMD-8000-0W
  37 # keys: defect.sunos.fmd.nosub
  38 #
  39 msgid "FMD-8000-0W.type"
  40 msgstr "Defect"
  41 msgid "FMD-8000-0W.severity"
  42 msgstr "Minor"
  43 msgid "FMD-8000-0W.description"
  44 msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
  45 msgid "FMD-8000-0W.response"
  46 msgstr "Error reports from the component will be logged for examination by Sun."
  47 msgid "FMD-8000-0W.impact"
  48 msgstr "Automated diagnosis and response for these events will not occur."
  49 msgid "FMD-8000-0W.action"
  50 msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly.  Contact Sun for support."
  51 #
  52 # code: FMD-8000-11
  53 # keys: defect.sunos.fmd.nodiagcode
  54 #
  55 msgid "FMD-8000-11.type"
  56 msgstr "Defect"
  57 msgid "FMD-8000-11.severity"
  58 msgstr "Minor"
  59 msgid "FMD-8000-11.description"
  60 msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
  61 msgid "FMD-8000-11.response"
  62 msgstr "The diagnosis has been saved in the fault log for examination by Sun."
  63 msgid "FMD-8000-11.impact"
  64 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
  65 msgid "FMD-8000-11.action"
  66 msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
  67 #
  68 # code: FMD-8000-2K
  69 # keys: defect.sunos.fmd.module
  70 #
  71 msgid "FMD-8000-2K.type"
  72 msgstr "Defect"
  73 msgid "FMD-8000-2K.severity"
  74 msgstr "Minor"
  75 msgid "FMD-8000-2K.description"
  76 msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
  77 msgid "FMD-8000-2K.response"
  78 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  79 msgid "FMD-8000-2K.impact"
  80 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  81 msgid "FMD-8000-2K.action"
  82 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
  83 #
  84 # code: FMD-8000-3F
  85 # keys: defect.sunos.fmd.config
  86 #
  87 msgid "FMD-8000-3F.type"
  88 msgstr "Defect"
  89 msgid "FMD-8000-3F.severity"
  90 msgstr "Minor"
  91 msgid "FMD-8000-3F.description"
  92 msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
  93 msgid "FMD-8000-3F.response"
  94 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  95 msgid "FMD-8000-3F.impact"
  96 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  97 msgid "FMD-8000-3F.action"
  98 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
  99 #
 100 # code: FMD-8000-4M
 101 # keys: list.repaired
 102 #
 103 msgid "FMD-8000-4M.type"
 104 msgstr "Repair"
 105 msgid "FMD-8000-4M.severity"
 106 msgstr "Minor"
 107 msgid "FMD-8000-4M.description"
 108 msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
 109 msgid "FMD-8000-4M.response"
 110 msgstr "Some system components offlined because of the original fault may have been brought back online."
 111 msgid "FMD-8000-4M.impact"
 112 msgstr "Performance degradation of the system due to the original fault may have been recovered."
  
 | 
 
 
  24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # General-purpose messages
  28 #
  29 msgid "syslog-msgs-message-template"
  30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
  31 #
  32 # Fault-related messages
  33 #
  34 #
  35 #
  36 # code: FMD-8000-0W
  37 # keys: defect.sunos.fmd.nosub
  38 #
  39 msgid "FMD-8000-0W.type"
  40 msgstr "Defect"
  41 msgid "FMD-8000-0W.severity"
  42 msgstr "Minor"
  43 msgid "FMD-8000-0W.description"
  44 msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
  45 msgid "FMD-8000-0W.response"
  46 msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
  47 msgid "FMD-8000-0W.impact"
  48 msgstr "Automated diagnosis and response for these events will not occur."
  49 msgid "FMD-8000-0W.action"
  50 msgstr "Ensure that fault management software is installed properly.  Contact your illumos distribution team for support."
  51 #
  52 # code: FMD-8000-11
  53 # keys: defect.sunos.fmd.nodiagcode
  54 #
  55 msgid "FMD-8000-11.type"
  56 msgstr "Defect"
  57 msgid "FMD-8000-11.severity"
  58 msgstr "Minor"
  59 msgid "FMD-8000-11.description"
  60 msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
  61 msgid "FMD-8000-11.response"
  62 msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team."
  63 msgid "FMD-8000-11.impact"
  64 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
  65 msgid "FMD-8000-11.action"
  66 msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Ensure that fault management software is installed properly."
  67 #
  68 # code: FMD-8000-2K
  69 # keys: defect.sunos.fmd.module
  70 #
  71 msgid "FMD-8000-2K.type"
  72 msgstr "Defect"
  73 msgid "FMD-8000-2K.severity"
  74 msgstr "Minor"
  75 msgid "FMD-8000-2K.description"
  76 msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
  77 msgid "FMD-8000-2K.response"
  78 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  79 msgid "FMD-8000-2K.impact"
  80 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  81 msgid "FMD-8000-2K.action"
  82 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
  83 #
  84 # code: FMD-8000-3F
  85 # keys: defect.sunos.fmd.config
  86 #
  87 msgid "FMD-8000-3F.type"
  88 msgstr "Defect"
  89 msgid "FMD-8000-3F.severity"
  90 msgstr "Minor"
  91 msgid "FMD-8000-3F.description"
  92 msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
  93 msgid "FMD-8000-3F.response"
  94 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  95 msgid "FMD-8000-3F.impact"
  96 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  97 msgid "FMD-8000-3F.action"
  98 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
  99 #
 100 # code: FMD-8000-4M
 101 # keys: list.repaired
 102 #
 103 msgid "FMD-8000-4M.type"
 104 msgstr "Repair"
 105 msgid "FMD-8000-4M.severity"
 106 msgstr "Minor"
 107 msgid "FMD-8000-4M.description"
 108 msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
 109 msgid "FMD-8000-4M.response"
 110 msgstr "Some system components offlined because of the original fault may have been brought back online."
 111 msgid "FMD-8000-4M.impact"
 112 msgstr "Performance degradation of the system due to the original fault may have been recovered."
  
 |