Print this page
DLPX-25998 TCP congestion control is inadequate
Reviewed at: http://reviews.delphix.com/r/34808/
@@ -8,11 +8,11 @@
.\" source. A copy of the CDDL is also available via the Internet at
.\" http://www.illumos.org/license/CDDL.
.\"
.\"
.\" Copyright (c) 2012, Joyent, Inc. All Rights Reserved
-.\" Copyright (c) 2013 by Delphix. All rights reserved.
+.\" Copyright (c) 2013, 2017 by Delphix. All rights reserved.
.\" Copyright 2018 Nexenta Systems, Inc.
.\" Copyright (c) 2016-2017, Chris Fraire <cfraire@me.com>.
.\"
.Dd February 6, 2018
.Dt IPADM 1M
@@ -774,10 +774,13 @@
.Sy + Ns | Ns Sy -
syntax can be used to add/remove values from the current list of values on the
property.
The property name can be one of the following:
.Bl -tag -compact -width "smallest_nonpriv_port"
+.It Cm congestion_control
+The default congestion-control algorithm to be used for new connections
+.Pq TCP .
.It Cm ecn
Explicit congestion control
.Pq Cm never Ns / Ns Cm passive Ns / Ns Cm active
.Pq TCP .
.It Cm extra_priv_ports