Print this page
8024 mdb_ctf_vread() needn't be so strict about unions
Reviewed by: Matthew Ahrens <mahrens@delphix.com>
Reviewed by: Pavel Zakharov <pavel.zakharov@delphix.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Approved by: Dan McDonald <danmcd@omniti.com>
NEX-6850 FMA messages need updating, badly
Reviewed by: Cynthia Eastham <cynthia.eastham@nexenta.com>
8490 Remove Sun/Solaris references from FMA messages
Reviewed by: Jason King <jason.king@joyent.com>
Reviewed by: Elijah Zupancic <elijah.zupancic@joyent.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
Reviewed by: Eric Sproul <eric.sproul@circonus.com>
Reviewed by: Dale Ghent <daleg@elemental.org>
Approved by: Gordon Ross <gordon.w.ross@gmail.com>
NEX-8148 Alerts should be sent if cores are created on a system
Reviewed by: Roman Strashkin <roman.strashkin@nexenta.com>
Reviewed by: Yuri Pankov <yuri.pankov@nexenta.com>

Split Close
Expand all
Collapse all
          --- old/usr/src/cmd/fm/dicts/SUNOS.po
          +++ new/usr/src/cmd/fm/dicts/SUNOS.po
   1    1  #
   2      -# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
   3      -#
   4    2  # CDDL HEADER START
   5    3  #
   6    4  # The contents of this file are subject to the terms of the
   7    5  # Common Development and Distribution License (the "License").
   8    6  # You may not use this file except in compliance with the License.
   9    7  #
  10    8  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  11    9  # or http://www.opensolaris.org/os/licensing.
  12   10  # See the License for the specific language governing permissions
  13   11  # and limitations under the License.
  14   12  #
  15   13  # When distributing Covered Code, include this CDDL HEADER in each
  16   14  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  17   15  # If applicable, add the following below this CDDL HEADER, with the
  18   16  # fields enclosed by brackets "[]" replaced with your own identifying
  19   17  # information: Portions Copyright [yyyy] [name of copyright owner]
  20   18  #
  21   19  # CDDL HEADER END
  22   20  #
  23   21  
  24      -# DO NOT EDIT -- this file is generated by the Event Registry.
  25   22  #
       23 +# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
       24 +# Copyright 2017 Nexenta Systems, Inc.
  26   25  #
       26 +
       27 +#
  27   28  # code: SUNOS-8000-0G
  28   29  # keys: ereport.sunos.unix.fm_panic
  29   30  #
  30   31  msgid "SUNOS-8000-0G.type"
  31   32  msgstr "Error"
  32   33  msgid "SUNOS-8000-0G.severity"
  33   34  msgstr "Major"
  34   35  msgid "SUNOS-8000-0G.description"
  35      -msgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
       36 +msgstr "Errors have been detected that require a reboot to ensure system integrity."
  36   37  msgid "SUNOS-8000-0G.response"
  37      -msgstr "illumos will attempt to save and diagnose the error telemetry"
       38 +msgstr "illumos will attempt to save and diagnose the error telemetry."
  38   39  msgid "SUNOS-8000-0G.impact"
  39      -msgstr "The system will sync files, save a crash dump if needed, and reboot"
       40 +msgstr "The system will sync files, save a crash dump if needed, and reboot."
  40   41  msgid "SUNOS-8000-0G.action"
  41      -msgstr "Save the error summary below in case telemetry cannot be saved"
       42 +msgstr "Save the error summary below in case telemetry cannot be saved."
  42   43  #
  43   44  # code: SUNOS-8000-1L
  44   45  # keys: defect.sunos.eft.undiagnosable_problem
  45   46  #
  46   47  msgid "SUNOS-8000-1L.type"
  47   48  msgstr "Defect"
  48   49  msgid "SUNOS-8000-1L.severity"
  49   50  msgstr "Minor"
  50   51  msgid "SUNOS-8000-1L.description"
  51      -msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
       52 +msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis."
  52   53  msgid "SUNOS-8000-1L.response"
  53      -msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
       54 +msgstr "Error reports from the component will be logged for examination."
  54   55  msgid "SUNOS-8000-1L.impact"
  55   56  msgstr "Automated diagnosis and response for these events will not occur."
  56   57  msgid "SUNOS-8000-1L.action"
  57      -msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
       58 +msgstr "Ensure that fault management software is installed properly."
  58   59  #
  59      -# code: SUNOS-8000-20
  60      -# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
  61      -#
  62      -msgid "SUNOS-8000-20.type"
  63      -msgstr "Fault"
  64      -msgid "SUNOS-8000-20.severity"
  65      -msgstr "Critical"
  66      -msgid "SUNOS-8000-20.description"
  67      -msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
  68      -msgid "SUNOS-8000-20.response"
  69      -msgstr "One or more of device instances may be disabled"
  70      -msgid "SUNOS-8000-20.impact"
  71      -msgstr "Loss of services provided by the device instances associated with this fault"
  72      -msgid "SUNOS-8000-20.action"
  73      -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
  74      -#
  75      -# code: SUNOS-8000-3V
  76      -# keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
  77      -#
  78      -msgid "SUNOS-8000-3V.type"
  79      -msgstr "Fault"
  80      -msgid "SUNOS-8000-3V.severity"
  81      -msgstr "Critical"
  82      -msgid "SUNOS-8000-3V.description"
  83      -msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
  84      -msgid "SUNOS-8000-3V.response"
  85      -msgstr "One or more of device instances may be disabled"
  86      -msgid "SUNOS-8000-3V.impact"
  87      -msgstr "Loss of services provided by the device instances associated with this fault"
  88      -msgid "SUNOS-8000-3V.action"
  89      -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
  90      -#
  91      -# code: SUNOS-8000-46
  92      -# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
  93      -#
  94      -msgid "SUNOS-8000-46.type"
  95      -msgstr "Fault"
  96      -msgid "SUNOS-8000-46.severity"
  97      -msgstr "Critical"
  98      -msgid "SUNOS-8000-46.description"
  99      -msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
 100      -msgid "SUNOS-8000-46.response"
 101      -msgstr "One or more of device instances may be disabled"
 102      -msgid "SUNOS-8000-46.impact"
 103      -msgstr "Loss of services provided by the device instances associated with this fault"
 104      -msgid "SUNOS-8000-46.action"
 105      -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
 106      -#
 107      -# code: SUNOS-8000-5T
 108      -# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
 109      -#
 110      -msgid "SUNOS-8000-5T.type"
 111      -msgstr "Fault"
 112      -msgid "SUNOS-8000-5T.severity"
 113      -msgstr "Critical"
 114      -msgid "SUNOS-8000-5T.description"
 115      -msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
 116      -msgid "SUNOS-8000-5T.response"
 117      -msgstr "One or more of device instances may be disabled"
 118      -msgid "SUNOS-8000-5T.impact"
 119      -msgstr "Loss of services provided by the device instances associated with this fault"
 120      -msgid "SUNOS-8000-5T.action"
 121      -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
 122      -#
 123      -# code: SUNOS-8000-69
 124      -# keys: defect.Deprecated fault.io.pci.device
 125      -#
 126      -msgid "SUNOS-8000-69.type"
 127      -msgstr "Fault"
 128      -msgid "SUNOS-8000-69.severity"
 129      -msgstr "Critical"
 130      -msgid "SUNOS-8000-69.description"
 131      -msgstr "A problem was detected for a PCI controller  Refer to %s for more information."
 132      -msgid "SUNOS-8000-69.response"
 133      -msgstr "One or more of device instances may be disabled"
 134      -msgid "SUNOS-8000-69.impact"
 135      -msgstr "Loss of services provided by the device instances associated with this fault."
 136      -msgid "SUNOS-8000-69.action"
 137      -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
 138      -#
 139      -# code: SUNOS-8000-7N
 140      -# keys: defect.Deprecated fault.io.pci.bus
 141      -#
 142      -msgid "SUNOS-8000-7N.type"
 143      -msgstr "Fault"
 144      -msgid "SUNOS-8000-7N.severity"
 145      -msgstr "Critical"
 146      -msgid "SUNOS-8000-7N.description"
 147      -msgstr "A problem was detected for a PCI bus  Refer to %s for more information."
 148      -msgid "SUNOS-8000-7N.response"
 149      -msgstr "One or more of device instances may be disabled"
 150      -msgid "SUNOS-8000-7N.impact"
 151      -msgstr "Loss of services provided by the device instances associated with this fault."
 152      -msgid "SUNOS-8000-7N.action"
 153      -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
 154      -#
 155      -# code: SUNOS-8000-8W
 156      -# keys: defect.Deprecated defect.io.pci.driver
 157      -#
 158      -msgid "SUNOS-8000-8W.type"
 159      -msgstr "Fault"
 160      -msgid "SUNOS-8000-8W.severity"
 161      -msgstr "Critical"
 162      -msgid "SUNOS-8000-8W.description"
 163      -msgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
 164      -msgid "SUNOS-8000-8W.response"
 165      -msgstr "One or more of device instances may be disabled"
 166      -msgid "SUNOS-8000-8W.impact"
 167      -msgstr "Loss of services provided by the device instances associated with this fault."
 168      -msgid "SUNOS-8000-8W.action"
 169      -msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
 170      -#
 171      -# code: SUNOS-8000-91
 172      -# keys: defect.sunos.zones.upgrade
 173      -#
 174      -msgid "SUNOS-8000-91.type"
 175      -msgstr "Defect"
 176      -msgid "SUNOS-8000-91.severity"
 177      -msgstr "Minor"
 178      -msgid "SUNOS-8000-91.description"
 179      -msgstr "\n      The illumos system or boot environment that is being upgraded\n has non-global zones installed.  The current version of Live\n  Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n        Refer to %s for more information."
 180      -msgid "SUNOS-8000-91.response"
 181      -msgstr "The upgrade procedure has been terminated."
 182      -msgid "SUNOS-8000-91.impact"
 183      -msgstr "The illumos system or boot environment is not upgraded."
 184      -msgid "SUNOS-8000-91.action"
 185      -msgstr "\n      Evaluate each of the choices below and select the one that is\n best for your needs.  Contact your illumos distribution team for support.\n     "
 186      -#
 187      -# code: SUNOS-8000-AK
 188      -# keys: ereport.sunos.boot.upgrade.menu_lst
 189      -#
 190      -msgid "SUNOS-8000-AK.type"
 191      -msgstr "Error"
 192      -msgid "SUNOS-8000-AK.severity"
 193      -msgstr "Critical"
 194      -msgid "SUNOS-8000-AK.description"
 195      -msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
 196      -msgid "SUNOS-8000-AK.response"
 197      -msgstr "No automated response."
 198      -msgid "SUNOS-8000-AK.impact"
 199      -msgstr "Future reboots could fail until this problem is corrected."
 200      -msgid "SUNOS-8000-AK.action"
 201      -msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
 202      -#
 203      -# code: SUNOS-8000-CF
 204      -# keys: ereport.sunos.boot.upgrade.menu_lst_bfu
 205      -#
 206      -msgid "SUNOS-8000-CF.type"
 207      -msgstr "Error"
 208      -msgid "SUNOS-8000-CF.severity"
 209      -msgstr "Critical"
 210      -msgid "SUNOS-8000-CF.description"
 211      -msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
 212      -msgid "SUNOS-8000-CF.response"
 213      -msgstr "No automated response."
 214      -msgid "SUNOS-8000-CF.impact"
 215      -msgstr "Future reboots could fail until this problem is corrected."
 216      -msgid "SUNOS-8000-CF.action"
 217      -msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
 218      -#
 219   60  # code: SUNOS-8000-DM
 220   61  # keys: defect.sunos.smf.svc.maintenance
 221   62  #
 222   63  msgid "SUNOS-8000-DM.type"
 223   64  msgstr "Defect"
 224   65  msgid "SUNOS-8000-DM.severity"
 225   66  msgstr "Major"
 226   67  msgid "SUNOS-8000-DM.description"
 227      -msgstr "A service failed and could not be restarted.  Refer to %s for more information."
       68 +msgstr "A service failed and could not be restarted."
 228   69  msgid "SUNOS-8000-DM.response"
 229   70  msgstr "The service has been placed into the maintenance state."
 230   71  msgid "SUNOS-8000-DM.impact"
 231   72  msgstr "The service is unavailable."
 232   73  msgid "SUNOS-8000-DM.action"
 233   74  msgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any."
 234   75  #
 235   76  # code: SUNOS-8000-E8
 236   77  # keys: defect.sunos.eft.undiag.checkpoint
 237   78  #
 238   79  msgid "SUNOS-8000-E8.type"
 239   80  msgstr "Defect"
 240   81  msgid "SUNOS-8000-E8.severity"
 241   82  msgstr "Minor"
 242   83  msgid "SUNOS-8000-E8.description"
 243      -msgstr "The diagnosis engine encountered an error while resuming diagnosis.  Refer to %s for more information."
       84 +msgstr "The diagnosis engine encountered an error while resuming diagnosis."
 244   85  msgid "SUNOS-8000-E8.response"
 245      -msgstr "Error reports have been logged for examination by your illumos distribution team."
       86 +msgstr "Error reports have been logged for examination."
 246   87  msgid "SUNOS-8000-E8.impact"
 247   88  msgstr "Automated diagnosis and response for these events will not occur."
 248   89  msgid "SUNOS-8000-E8.action"
 249      -msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager."
       90 +msgstr "Repair this defect, and restart the fault manager."
 250   91  #
 251   92  # code: SUNOS-8000-FU
 252   93  # keys: defect.sunos.eft.undiag.fme
 253   94  #
 254   95  msgid "SUNOS-8000-FU.type"
 255   96  msgstr "Defect"
 256   97  msgid "SUNOS-8000-FU.severity"
 257   98  msgstr "Major"
 258   99  msgid "SUNOS-8000-FU.description"
 259      -msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
      100 +msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis."
 260  101  msgid "SUNOS-8000-FU.response"
 261      -msgstr "Error reports have been logged for examination by your illumos distribution team."
      102 +msgstr "Error reports have been logged for examination."
 262  103  msgid "SUNOS-8000-FU.impact"
 263  104  msgstr "Automated diagnosis and response for these events will not occur."
 264  105  msgid "SUNOS-8000-FU.action"
 265      -msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
      106 +msgstr "Ensure that the latest updates are installed."
 266  107  #
 267  108  # code: SUNOS-8000-G7
 268  109  # keys: defect.sunos.eft.undiag.limit
 269  110  #
 270  111  msgid "SUNOS-8000-G7.type"
 271  112  msgstr "Defect"
 272  113  msgid "SUNOS-8000-G7.severity"
 273  114  msgstr "Minor"
 274  115  msgid "SUNOS-8000-G7.description"
 275      -msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis.  Refer to %s for more information."
      116 +msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis."
 276  117  msgid "SUNOS-8000-G7.response"
 277      -msgstr "Error reports have been logged for examination by your illumos distribution team."
      118 +msgstr "Error reports have been logged for examination."
 278  119  msgid "SUNOS-8000-G7.impact"
 279  120  msgstr "Automated diagnosis and response for these events will not occur."
 280  121  msgid "SUNOS-8000-G7.action"
 281      -msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
      122 +msgstr "Ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
 282  123  #
 283  124  # code: SUNOS-8000-HV
 284  125  # keys: defect.sunos.eft.undiag.unknown
 285  126  #
 286  127  msgid "SUNOS-8000-HV.type"
 287  128  msgstr "Defect"
 288  129  msgid "SUNOS-8000-HV.severity"
 289  130  msgstr "Minor"
 290  131  msgid "SUNOS-8000-HV.description"
 291      -msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
      132 +msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis."
 292  133  msgid "SUNOS-8000-HV.response"
 293      -msgstr "Error reports have been logged for examination by your illumos distribution team."
      134 +msgstr "Error reports have been logged for examination."
 294  135  msgid "SUNOS-8000-HV.impact"
 295  136  msgstr "Automated diagnosis and response for these events will not occur."
 296  137  msgid "SUNOS-8000-HV.action"
 297      -msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
      138 +msgstr "Ensure that the latest updates are installed."
 298  139  #
 299  140  # code: SUNOS-8000-J0
 300  141  # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry
 301  142  #
 302  143  msgid "SUNOS-8000-J0.type"
 303  144  msgstr "Fault"
 304  145  msgid "SUNOS-8000-J0.severity"
 305  146  msgstr "Major"
 306  147  msgid "SUNOS-8000-J0.description"
 307      -msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n  Refer to %s for more information.  Refer to %s for more information."
      148 +msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %."
 308  149  msgid "SUNOS-8000-J0.response"
 309      -msgstr "Error reports have been logged for examination by your illumos distribution team.\n"
      150 +msgstr "Error reports have been logged for examination."
 310  151  msgid "SUNOS-8000-J0.impact"
 311      -msgstr "Automated diagnosis and response for these events will not occur.\n"
      152 +msgstr "Automated diagnosis and response for these events will not occur."
 312  153  msgid "SUNOS-8000-J0.action"
 313      -msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n"
      154 +msgstr "Ensure that the latest updates are installed."
 314  155  #
 315  156  # code: SUNOS-8000-KL
 316  157  # keys: defect.sunos.kernel.panic
 317  158  #
 318  159  msgid "SUNOS-8000-KL.type"
 319  160  msgstr "Defect"
 320  161  msgid "SUNOS-8000-KL.severity"
 321  162  msgstr "Major"
 322  163  msgid "SUNOS-8000-KL.description"
 323      -msgstr "The system has rebooted after a kernel panic.  Refer to %s for more information."
      164 +msgstr "The system has rebooted after a kernel panic."
 324  165  msgid "SUNOS-8000-KL.response"
 325      -msgstr "The failed system image was dumped to the dump device.  If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>."
      166 +msgstr "The failed system image was dumped to the dump device."
 326  167  msgid "SUNOS-8000-KL.impact"
 327  168  msgstr "There may be some performance impact while the panic is copied to the savecore directory.  Disk space usage by panics can be substantial."
 328  169  msgid "SUNOS-8000-KL.action"
 329      -msgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail.  Please refer to the knowledge article for additional information."
      170 +msgstr "If savecore is not enabled then take steps to preserve the crash image."
      171 +#
      172 +# code: SUNOS-8000-LG
      173 +# keys: defect.sunos.system.core
      174 +#
      175 +msgid "SUNOS-8000-LG.type"
      176 +msgstr "Defect"
      177 +msgid "SUNOS-8000-LG.severity"
      178 +msgstr "Major"
      179 +msgid "SUNOS-8000-LG.description"
      180 +msgstr "A process was terminated by OS due to unexpected failure."
      181 +msgid "SUNOS-8000-LG.response"
      182 +msgstr "Core of the process has been generated for later analysis."
      183 +msgid "SUNOS-8000-LG.impact"
      184 +msgstr "Service provided by the process may be temporarily or permanently degraded."
      185 +msgid "SUNOS-8000-LG.action"
      186 +msgstr "Process core should be analysed to find a root cause of the problem."
    
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX