1 #
   2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
   3 #
   4 # CDDL HEADER START
   5 #
   6 # The contents of this file are subject to the terms of the
   7 # Common Development and Distribution License (the "License").
   8 # You may not use this file except in compliance with the License.
   9 #
  10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  11 # or http://www.opensolaris.org/os/licensing.
  12 # See the License for the specific language governing permissions
  13 # and limitations under the License.
  14 #
  15 # When distributing Covered Code, include this CDDL HEADER in each
  16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  17 # If applicable, add the following below this CDDL HEADER, with the
  18 # fields enclosed by brackets "[]" replaced with your own identifying
  19 # information: Portions Copyright [yyyy] [name of copyright owner]
  20 #
  21 # CDDL HEADER END
  22 #
  23 
  24 # DO NOT EDIT -- this file is generated by the Event Registry.
  25 #
  26 #
  27 # code: SUNOS-8000-0G
  28 # keys: ereport.sunos.unix.fm_panic
  29 #
  30 msgid "SUNOS-8000-0G.type"
  31 msgstr "Error"
  32 msgid "SUNOS-8000-0G.severity"
  33 msgstr "Major"
  34 msgid "SUNOS-8000-0G.description"
  35 msgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
  36 msgid "SUNOS-8000-0G.response"
  37 msgstr "illumos will attempt to save and diagnose the error telemetry"
  38 msgid "SUNOS-8000-0G.impact"
  39 msgstr "The system will sync files, save a crash dump if needed, and reboot"
  40 msgid "SUNOS-8000-0G.action"
  41 msgstr "Save the error summary below in case telemetry cannot be saved"
  42 #
  43 # code: SUNOS-8000-1L
  44 # keys: defect.sunos.eft.undiagnosable_problem
  45 #
  46 msgid "SUNOS-8000-1L.type"
  47 msgstr "Defect"
  48 msgid "SUNOS-8000-1L.severity"
  49 msgstr "Minor"
  50 msgid "SUNOS-8000-1L.description"
  51 msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
  52 msgid "SUNOS-8000-1L.response"
  53 msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
  54 msgid "SUNOS-8000-1L.impact"
  55 msgstr "Automated diagnosis and response for these events will not occur."
  56 msgid "SUNOS-8000-1L.action"
  57 msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
  58 #
  59 # code: SUNOS-8000-20
  60 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
  61 #
  62 msgid "SUNOS-8000-20.type"
  63 msgstr "Fault"
  64 msgid "SUNOS-8000-20.severity"
  65 msgstr "Critical"
  66 msgid "SUNOS-8000-20.description"
  67 msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
  68 msgid "SUNOS-8000-20.response"
  69 msgstr "One or more of device instances may be disabled"
  70 msgid "SUNOS-8000-20.impact"
  71 msgstr "Loss of services provided by the device instances associated with this fault"
  72 msgid "SUNOS-8000-20.action"
  73 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
  74 #
  75 # code: SUNOS-8000-3V
  76 # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
  77 #
  78 msgid "SUNOS-8000-3V.type"
  79 msgstr "Fault"
  80 msgid "SUNOS-8000-3V.severity"
  81 msgstr "Critical"
  82 msgid "SUNOS-8000-3V.description"
  83 msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
  84 msgid "SUNOS-8000-3V.response"
  85 msgstr "One or more of device instances may be disabled"
  86 msgid "SUNOS-8000-3V.impact"
  87 msgstr "Loss of services provided by the device instances associated with this fault"
  88 msgid "SUNOS-8000-3V.action"
  89 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
  90 #
  91 # code: SUNOS-8000-46
  92 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
  93 #
  94 msgid "SUNOS-8000-46.type"
  95 msgstr "Fault"
  96 msgid "SUNOS-8000-46.severity"
  97 msgstr "Critical"
  98 msgid "SUNOS-8000-46.description"
  99 msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
 100 msgid "SUNOS-8000-46.response"
 101 msgstr "One or more of device instances may be disabled"
 102 msgid "SUNOS-8000-46.impact"
 103 msgstr "Loss of services provided by the device instances associated with this fault"
 104 msgid "SUNOS-8000-46.action"
 105 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
 106 #
 107 # code: SUNOS-8000-5T
 108 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
 109 #
 110 msgid "SUNOS-8000-5T.type"
 111 msgstr "Fault"
 112 msgid "SUNOS-8000-5T.severity"
 113 msgstr "Critical"
 114 msgid "SUNOS-8000-5T.description"
 115 msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
 116 msgid "SUNOS-8000-5T.response"
 117 msgstr "One or more of device instances may be disabled"
 118 msgid "SUNOS-8000-5T.impact"
 119 msgstr "Loss of services provided by the device instances associated with this fault"
 120 msgid "SUNOS-8000-5T.action"
 121 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
 122 #
 123 # code: SUNOS-8000-69
 124 # keys: defect.Deprecated fault.io.pci.device
 125 #
 126 msgid "SUNOS-8000-69.type"
 127 msgstr "Fault"
 128 msgid "SUNOS-8000-69.severity"
 129 msgstr "Critical"
 130 msgid "SUNOS-8000-69.description"
 131 msgstr "A problem was detected for a PCI controller  Refer to %s for more information."
 132 msgid "SUNOS-8000-69.response"
 133 msgstr "One or more of device instances may be disabled"
 134 msgid "SUNOS-8000-69.impact"
 135 msgstr "Loss of services provided by the device instances associated with this fault."
 136 msgid "SUNOS-8000-69.action"
 137 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
 138 #
 139 # code: SUNOS-8000-7N
 140 # keys: defect.Deprecated fault.io.pci.bus
 141 #
 142 msgid "SUNOS-8000-7N.type"
 143 msgstr "Fault"
 144 msgid "SUNOS-8000-7N.severity"
 145 msgstr "Critical"
 146 msgid "SUNOS-8000-7N.description"
 147 msgstr "A problem was detected for a PCI bus  Refer to %s for more information."
 148 msgid "SUNOS-8000-7N.response"
 149 msgstr "One or more of device instances may be disabled"
 150 msgid "SUNOS-8000-7N.impact"
 151 msgstr "Loss of services provided by the device instances associated with this fault."
 152 msgid "SUNOS-8000-7N.action"
 153 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
 154 #
 155 # code: SUNOS-8000-8W
 156 # keys: defect.Deprecated defect.io.pci.driver
 157 #
 158 msgid "SUNOS-8000-8W.type"
 159 msgstr "Fault"
 160 msgid "SUNOS-8000-8W.severity"
 161 msgstr "Critical"
 162 msgid "SUNOS-8000-8W.description"
 163 msgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
 164 msgid "SUNOS-8000-8W.response"
 165 msgstr "One or more of device instances may be disabled"
 166 msgid "SUNOS-8000-8W.impact"
 167 msgstr "Loss of services provided by the device instances associated with this fault."
 168 msgid "SUNOS-8000-8W.action"
 169 msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
 170 #
 171 # code: SUNOS-8000-91
 172 # keys: defect.sunos.zones.upgrade
 173 #
 174 msgid "SUNOS-8000-91.type"
 175 msgstr "Defect"
 176 msgid "SUNOS-8000-91.severity"
 177 msgstr "Minor"
 178 msgid "SUNOS-8000-91.description"
 179 msgstr "\n      The illumos system or boot environment that is being upgraded\n has non-global zones installed.  The current version of Live\n  Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n        Refer to %s for more information."
 180 msgid "SUNOS-8000-91.response"
 181 msgstr "The upgrade procedure has been terminated."
 182 msgid "SUNOS-8000-91.impact"
 183 msgstr "The illumos system or boot environment is not upgraded."
 184 msgid "SUNOS-8000-91.action"
 185 msgstr "\n      Evaluate each of the choices below and select the one that is\n best for your needs.  Contact your illumos distribution team for support.\n     "
 186 #
 187 # code: SUNOS-8000-AK
 188 # keys: ereport.sunos.boot.upgrade.menu_lst
 189 #
 190 msgid "SUNOS-8000-AK.type"
 191 msgstr "Error"
 192 msgid "SUNOS-8000-AK.severity"
 193 msgstr "Critical"
 194 msgid "SUNOS-8000-AK.description"
 195 msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
 196 msgid "SUNOS-8000-AK.response"
 197 msgstr "No automated response."
 198 msgid "SUNOS-8000-AK.impact"
 199 msgstr "Future reboots could fail until this problem is corrected."
 200 msgid "SUNOS-8000-AK.action"
 201 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
 202 #
 203 # code: SUNOS-8000-CF
 204 # keys: ereport.sunos.boot.upgrade.menu_lst_bfu
 205 #
 206 msgid "SUNOS-8000-CF.type"
 207 msgstr "Error"
 208 msgid "SUNOS-8000-CF.severity"
 209 msgstr "Critical"
 210 msgid "SUNOS-8000-CF.description"
 211 msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
 212 msgid "SUNOS-8000-CF.response"
 213 msgstr "No automated response."
 214 msgid "SUNOS-8000-CF.impact"
 215 msgstr "Future reboots could fail until this problem is corrected."
 216 msgid "SUNOS-8000-CF.action"
 217 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
 218 #
 219 # code: SUNOS-8000-DM
 220 # keys: defect.sunos.smf.svc.maintenance
 221 #
 222 msgid "SUNOS-8000-DM.type"
 223 msgstr "Defect"
 224 msgid "SUNOS-8000-DM.severity"
 225 msgstr "Major"
 226 msgid "SUNOS-8000-DM.description"
 227 msgstr "A service failed and could not be restarted.  Refer to %s for more information."
 228 msgid "SUNOS-8000-DM.response"
 229 msgstr "The service has been placed into the maintenance state."
 230 msgid "SUNOS-8000-DM.impact"
 231 msgstr "The service is unavailable."
 232 msgid "SUNOS-8000-DM.action"
 233 msgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any."
 234 #
 235 # code: SUNOS-8000-E8
 236 # keys: defect.sunos.eft.undiag.checkpoint
 237 #
 238 msgid "SUNOS-8000-E8.type"
 239 msgstr "Defect"
 240 msgid "SUNOS-8000-E8.severity"
 241 msgstr "Minor"
 242 msgid "SUNOS-8000-E8.description"
 243 msgstr "The diagnosis engine encountered an error while resuming diagnosis.  Refer to %s for more information."
 244 msgid "SUNOS-8000-E8.response"
 245 msgstr "Error reports have been logged for examination by your illumos distribution team."
 246 msgid "SUNOS-8000-E8.impact"
 247 msgstr "Automated diagnosis and response for these events will not occur."
 248 msgid "SUNOS-8000-E8.action"
 249 msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager."
 250 #
 251 # code: SUNOS-8000-FU
 252 # keys: defect.sunos.eft.undiag.fme
 253 #
 254 msgid "SUNOS-8000-FU.type"
 255 msgstr "Defect"
 256 msgid "SUNOS-8000-FU.severity"
 257 msgstr "Major"
 258 msgid "SUNOS-8000-FU.description"
 259 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
 260 msgid "SUNOS-8000-FU.response"
 261 msgstr "Error reports have been logged for examination by your illumos distribution team."
 262 msgid "SUNOS-8000-FU.impact"
 263 msgstr "Automated diagnosis and response for these events will not occur."
 264 msgid "SUNOS-8000-FU.action"
 265 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
 266 #
 267 # code: SUNOS-8000-G7
 268 # keys: defect.sunos.eft.undiag.limit
 269 #
 270 msgid "SUNOS-8000-G7.type"
 271 msgstr "Defect"
 272 msgid "SUNOS-8000-G7.severity"
 273 msgstr "Minor"
 274 msgid "SUNOS-8000-G7.description"
 275 msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis.  Refer to %s for more information."
 276 msgid "SUNOS-8000-G7.response"
 277 msgstr "Error reports have been logged for examination by your illumos distribution team."
 278 msgid "SUNOS-8000-G7.impact"
 279 msgstr "Automated diagnosis and response for these events will not occur."
 280 msgid "SUNOS-8000-G7.action"
 281 msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
 282 #
 283 # code: SUNOS-8000-HV
 284 # keys: defect.sunos.eft.undiag.unknown
 285 #
 286 msgid "SUNOS-8000-HV.type"
 287 msgstr "Defect"
 288 msgid "SUNOS-8000-HV.severity"
 289 msgstr "Minor"
 290 msgid "SUNOS-8000-HV.description"
 291 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
 292 msgid "SUNOS-8000-HV.response"
 293 msgstr "Error reports have been logged for examination by your illumos distribution team."
 294 msgid "SUNOS-8000-HV.impact"
 295 msgstr "Automated diagnosis and response for these events will not occur."
 296 msgid "SUNOS-8000-HV.action"
 297 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
 298 #
 299 # code: SUNOS-8000-J0
 300 # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry
 301 #
 302 msgid "SUNOS-8000-J0.type"
 303 msgstr "Fault"
 304 msgid "SUNOS-8000-J0.severity"
 305 msgstr "Major"
 306 msgid "SUNOS-8000-J0.description"
 307 msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n  Refer to %s for more information.  Refer to %s for more information."
 308 msgid "SUNOS-8000-J0.response"
 309 msgstr "Error reports have been logged for examination by your illumos distribution team.\n"
 310 msgid "SUNOS-8000-J0.impact"
 311 msgstr "Automated diagnosis and response for these events will not occur.\n"
 312 msgid "SUNOS-8000-J0.action"
 313 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n"
 314 #
 315 # code: SUNOS-8000-KL
 316 # keys: defect.sunos.kernel.panic
 317 #
 318 msgid "SUNOS-8000-KL.type"
 319 msgstr "Defect"
 320 msgid "SUNOS-8000-KL.severity"
 321 msgstr "Major"
 322 msgid "SUNOS-8000-KL.description"
 323 msgstr "The system has rebooted after a kernel panic.  Refer to %s for more information."
 324 msgid "SUNOS-8000-KL.response"
 325 msgstr "The failed system image was dumped to the dump device.  If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>."
 326 msgid "SUNOS-8000-KL.impact"
 327 msgstr "There may be some performance impact while the panic is copied to the savecore directory.  Disk space usage by panics can be substantial."
 328 msgid "SUNOS-8000-KL.action"
 329 msgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail.  Please refer to the knowledge article for additional information."