1 # 2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 3 # 4 # CDDL HEADER START 5 # 6 # The contents of this file are subject to the terms of the 7 # Common Development and Distribution License (the "License"). 8 # You may not use this file except in compliance with the License. 9 # 10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 11 # or http://www.opensolaris.org/os/licensing. 12 # See the License for the specific language governing permissions 13 # and limitations under the License. 14 # 15 # When distributing Covered Code, include this CDDL HEADER in each 16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 17 # If applicable, add the following below this CDDL HEADER, with the 18 # fields enclosed by brackets "[]" replaced with your own identifying 19 # information: Portions Copyright [yyyy] [name of copyright owner] 20 # 21 # CDDL HEADER END 22 # 23 24 # DO NOT EDIT -- this file is generated by the Event Registry. 25 # 26 # 27 # code: SUNOS-8000-0G 28 # keys: ereport.sunos.unix.fm_panic 29 # 30 msgid "SUNOS-8000-0G.type" 31 msgstr "Error" 32 msgid "SUNOS-8000-0G.severity" 33 msgstr "Major" 34 msgid "SUNOS-8000-0G.description" 35 msgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." 36 msgid "SUNOS-8000-0G.response" 37 msgstr "illumos will attempt to save and diagnose the error telemetry" 38 msgid "SUNOS-8000-0G.impact" 39 msgstr "The system will sync files, save a crash dump if needed, and reboot" 40 msgid "SUNOS-8000-0G.action" 41 msgstr "Save the error summary below in case telemetry cannot be saved" 42 # 43 # code: SUNOS-8000-1L 44 # keys: defect.sunos.eft.undiagnosable_problem 45 # 46 msgid "SUNOS-8000-1L.type" 47 msgstr "Defect" 48 msgid "SUNOS-8000-1L.severity" 49 msgstr "Minor" 50 msgid "SUNOS-8000-1L.description" 51 msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. Refer to %s for more information." 52 msgid "SUNOS-8000-1L.response" 53 msgstr "Error reports from the component will be logged for examination by your illumos distribution team." 54 msgid "SUNOS-8000-1L.impact" 55 msgstr "Automated diagnosis and response for these events will not occur." 56 msgid "SUNOS-8000-1L.action" 57 msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support." 58 # 59 # code: SUNOS-8000-20 60 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device 61 # 62 msgid "SUNOS-8000-20.type" 63 msgstr "Fault" 64 msgid "SUNOS-8000-20.severity" 65 msgstr "Critical" 66 msgid "SUNOS-8000-20.description" 67 msgstr "A problem was detected in the SUNOS subsystem or controlling software. Refer to %s for more information." 68 msgid "SUNOS-8000-20.response" 69 msgstr "One or more of device instances may be disabled" 70 msgid "SUNOS-8000-20.impact" 71 msgstr "Loss of services provided by the device instances associated with this fault" 72 msgid "SUNOS-8000-20.action" 73 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." 74 # 75 # code: SUNOS-8000-3V 76 # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device 77 # 78 msgid "SUNOS-8000-3V.type" 79 msgstr "Fault" 80 msgid "SUNOS-8000-3V.severity" 81 msgstr "Critical" 82 msgid "SUNOS-8000-3V.description" 83 msgstr "A problem was detected in the PCI subsystem. Refer to %s for more information." 84 msgid "SUNOS-8000-3V.response" 85 msgstr "One or more of device instances may be disabled" 86 msgid "SUNOS-8000-3V.impact" 87 msgstr "Loss of services provided by the device instances associated with this fault" 88 msgid "SUNOS-8000-3V.action" 89 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." 90 # 91 # code: SUNOS-8000-46 92 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device 93 # 94 msgid "SUNOS-8000-46.type" 95 msgstr "Fault" 96 msgid "SUNOS-8000-46.severity" 97 msgstr "Critical" 98 msgid "SUNOS-8000-46.description" 99 msgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." 100 msgid "SUNOS-8000-46.response" 101 msgstr "One or more of device instances may be disabled" 102 msgid "SUNOS-8000-46.impact" 103 msgstr "Loss of services provided by the device instances associated with this fault" 104 msgid "SUNOS-8000-46.action" 105 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." 106 # 107 # code: SUNOS-8000-5T 108 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus 109 # 110 msgid "SUNOS-8000-5T.type" 111 msgstr "Fault" 112 msgid "SUNOS-8000-5T.severity" 113 msgstr "Critical" 114 msgid "SUNOS-8000-5T.description" 115 msgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." 116 msgid "SUNOS-8000-5T.response" 117 msgstr "One or more of device instances may be disabled" 118 msgid "SUNOS-8000-5T.impact" 119 msgstr "Loss of services provided by the device instances associated with this fault" 120 msgid "SUNOS-8000-5T.action" 121 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." 122 # 123 # code: SUNOS-8000-69 124 # keys: defect.Deprecated fault.io.pci.device 125 # 126 msgid "SUNOS-8000-69.type" 127 msgstr "Fault" 128 msgid "SUNOS-8000-69.severity" 129 msgstr "Critical" 130 msgid "SUNOS-8000-69.description" 131 msgstr "A problem was detected for a PCI controller Refer to %s for more information." 132 msgid "SUNOS-8000-69.response" 133 msgstr "One or more of device instances may be disabled" 134 msgid "SUNOS-8000-69.impact" 135 msgstr "Loss of services provided by the device instances associated with this fault." 136 msgid "SUNOS-8000-69.action" 137 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." 138 # 139 # code: SUNOS-8000-7N 140 # keys: defect.Deprecated fault.io.pci.bus 141 # 142 msgid "SUNOS-8000-7N.type" 143 msgstr "Fault" 144 msgid "SUNOS-8000-7N.severity" 145 msgstr "Critical" 146 msgid "SUNOS-8000-7N.description" 147 msgstr "A problem was detected for a PCI bus Refer to %s for more information." 148 msgid "SUNOS-8000-7N.response" 149 msgstr "One or more of device instances may be disabled" 150 msgid "SUNOS-8000-7N.impact" 151 msgstr "Loss of services provided by the device instances associated with this fault." 152 msgid "SUNOS-8000-7N.action" 153 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." 154 # 155 # code: SUNOS-8000-8W 156 # keys: defect.Deprecated defect.io.pci.driver 157 # 158 msgid "SUNOS-8000-8W.type" 159 msgstr "Fault" 160 msgid "SUNOS-8000-8W.severity" 161 msgstr "Critical" 162 msgid "SUNOS-8000-8W.description" 163 msgstr "A problem was detected in the PCI controller software Refer to %s for more information." 164 msgid "SUNOS-8000-8W.response" 165 msgstr "One or more of device instances may be disabled" 166 msgid "SUNOS-8000-8W.impact" 167 msgstr "Loss of services provided by the device instances associated with this fault." 168 msgid "SUNOS-8000-8W.action" 169 msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." 170 # 171 # code: SUNOS-8000-91 172 # keys: defect.sunos.zones.upgrade 173 # 174 msgid "SUNOS-8000-91.type" 175 msgstr "Defect" 176 msgid "SUNOS-8000-91.severity" 177 msgstr "Minor" 178 msgid "SUNOS-8000-91.description" 179 msgstr "\n The illumos system or boot environment that is being upgraded\n has non-global zones installed. The current version of Live\n Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n Refer to %s for more information." 180 msgid "SUNOS-8000-91.response" 181 msgstr "The upgrade procedure has been terminated." 182 msgid "SUNOS-8000-91.impact" 183 msgstr "The illumos system or boot environment is not upgraded." 184 msgid "SUNOS-8000-91.action" 185 msgstr "\n Evaluate each of the choices below and select the one that is\n best for your needs. Contact your illumos distribution team for support.\n " 186 # 187 # code: SUNOS-8000-AK 188 # keys: ereport.sunos.boot.upgrade.menu_lst 189 # 190 msgid "SUNOS-8000-AK.type" 191 msgstr "Error" 192 msgid "SUNOS-8000-AK.severity" 193 msgstr "Critical" 194 msgid "SUNOS-8000-AK.description" 195 msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." 196 msgid "SUNOS-8000-AK.response" 197 msgstr "No automated response." 198 msgid "SUNOS-8000-AK.impact" 199 msgstr "Future reboots could fail until this problem is corrected." 200 msgid "SUNOS-8000-AK.action" 201 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details." 202 # 203 # code: SUNOS-8000-CF 204 # keys: ereport.sunos.boot.upgrade.menu_lst_bfu 205 # 206 msgid "SUNOS-8000-CF.type" 207 msgstr "Error" 208 msgid "SUNOS-8000-CF.severity" 209 msgstr "Critical" 210 msgid "SUNOS-8000-CF.description" 211 msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." 212 msgid "SUNOS-8000-CF.response" 213 msgstr "No automated response." 214 msgid "SUNOS-8000-CF.impact" 215 msgstr "Future reboots could fail until this problem is corrected." 216 msgid "SUNOS-8000-CF.action" 217 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details." 218 # 219 # code: SUNOS-8000-DM 220 # keys: defect.sunos.smf.svc.maintenance 221 # 222 msgid "SUNOS-8000-DM.type" 223 msgstr "Defect" 224 msgid "SUNOS-8000-DM.severity" 225 msgstr "Major" 226 msgid "SUNOS-8000-DM.description" 227 msgstr "A service failed and could not be restarted. Refer to %s for more information." 228 msgid "SUNOS-8000-DM.response" 229 msgstr "The service has been placed into the maintenance state." 230 msgid "SUNOS-8000-DM.impact" 231 msgstr "The service is unavailable." 232 msgid "SUNOS-8000-DM.action" 233 msgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any." 234 # 235 # code: SUNOS-8000-E8 236 # keys: defect.sunos.eft.undiag.checkpoint 237 # 238 msgid "SUNOS-8000-E8.type" 239 msgstr "Defect" 240 msgid "SUNOS-8000-E8.severity" 241 msgstr "Minor" 242 msgid "SUNOS-8000-E8.description" 243 msgstr "The diagnosis engine encountered an error while resuming diagnosis. Refer to %s for more information." 244 msgid "SUNOS-8000-E8.response" 245 msgstr "Error reports have been logged for examination by your illumos distribution team." 246 msgid "SUNOS-8000-E8.impact" 247 msgstr "Automated diagnosis and response for these events will not occur." 248 msgid "SUNOS-8000-E8.action" 249 msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager." 250 # 251 # code: SUNOS-8000-FU 252 # keys: defect.sunos.eft.undiag.fme 253 # 254 msgid "SUNOS-8000-FU.type" 255 msgstr "Defect" 256 msgid "SUNOS-8000-FU.severity" 257 msgstr "Major" 258 msgid "SUNOS-8000-FU.description" 259 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." 260 msgid "SUNOS-8000-FU.response" 261 msgstr "Error reports have been logged for examination by your illumos distribution team." 262 msgid "SUNOS-8000-FU.impact" 263 msgstr "Automated diagnosis and response for these events will not occur." 264 msgid "SUNOS-8000-FU.action" 265 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed." 266 # 267 # code: SUNOS-8000-G7 268 # keys: defect.sunos.eft.undiag.limit 269 # 270 msgid "SUNOS-8000-G7.type" 271 msgstr "Defect" 272 msgid "SUNOS-8000-G7.severity" 273 msgstr "Minor" 274 msgid "SUNOS-8000-G7.description" 275 msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis. Refer to %s for more information." 276 msgid "SUNOS-8000-G7.response" 277 msgstr "Error reports have been logged for examination by your illumos distribution team." 278 msgid "SUNOS-8000-G7.impact" 279 msgstr "Automated diagnosis and response for these events will not occur." 280 msgid "SUNOS-8000-G7.action" 281 msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager." 282 # 283 # code: SUNOS-8000-HV 284 # keys: defect.sunos.eft.undiag.unknown 285 # 286 msgid "SUNOS-8000-HV.type" 287 msgstr "Defect" 288 msgid "SUNOS-8000-HV.severity" 289 msgstr "Minor" 290 msgid "SUNOS-8000-HV.description" 291 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." 292 msgid "SUNOS-8000-HV.response" 293 msgstr "Error reports have been logged for examination by your illumos distribution team." 294 msgid "SUNOS-8000-HV.impact" 295 msgstr "Automated diagnosis and response for these events will not occur." 296 msgid "SUNOS-8000-HV.action" 297 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed." 298 # 299 # code: SUNOS-8000-J0 300 # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry 301 # 302 msgid "SUNOS-8000-J0.type" 303 msgstr "Fault" 304 msgid "SUNOS-8000-J0.severity" 305 msgstr "Major" 306 msgid "SUNOS-8000-J0.description" 307 msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n Refer to %s for more information. Refer to %s for more information." 308 msgid "SUNOS-8000-J0.response" 309 msgstr "Error reports have been logged for examination by your illumos distribution team.\n" 310 msgid "SUNOS-8000-J0.impact" 311 msgstr "Automated diagnosis and response for these events will not occur.\n" 312 msgid "SUNOS-8000-J0.action" 313 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n" 314 # 315 # code: SUNOS-8000-KL 316 # keys: defect.sunos.kernel.panic 317 # 318 msgid "SUNOS-8000-KL.type" 319 msgstr "Defect" 320 msgid "SUNOS-8000-KL.severity" 321 msgstr "Major" 322 msgid "SUNOS-8000-KL.description" 323 msgstr "The system has rebooted after a kernel panic. Refer to %s for more information." 324 msgid "SUNOS-8000-KL.response" 325 msgstr "The failed system image was dumped to the dump device. If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>." 326 msgid "SUNOS-8000-KL.impact" 327 msgstr "There may be some performance impact while the panic is copied to the savecore directory. Disk space usage by panics can be substantial." 328 msgid "SUNOS-8000-KL.action" 329 msgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail. Please refer to the knowledge article for additional information."