Print this page
NEX-16536 SUN-IREPORT-MIB is broken
NEX-16537 enhance FM traps
NEX-16545 SMF dict should have obsolete entries removed
Reviewed by: Dan Fields <dan.fields@nexenta.com>
Reviewed by: Cynthia Eastham <cynthia.eastham@nexenta.com>
Reviewed by: Alexander Eremin <alexander.eremin@nexenta.com>
Reviewed by: Evan Layton <evan.layton@nexenta.com>
8024 mdb_ctf_vread() needn't be so strict about unions
Reviewed by: Matthew Ahrens <mahrens@delphix.com>
Reviewed by: Pavel Zakharov <pavel.zakharov@delphix.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Approved by: Dan McDonald <danmcd@omniti.com>
NEX-6850 FMA messages need updating, badly
Reviewed by: Cynthia Eastham <cynthia.eastham@nexenta.com>
| Split |
Close |
| Expand all |
| Collapse all |
--- old/usr/src/cmd/fm/dicts/SMF.po
+++ new/usr/src/cmd/fm/dicts/SMF.po
1 1 #
2 -# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
3 -#
4 2 # CDDL HEADER START
5 3 #
6 4 # The contents of this file are subject to the terms of the
7 5 # Common Development and Distribution License (the "License").
8 6 # You may not use this file except in compliance with the License.
9 7 #
10 8 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11 9 # or http://www.opensolaris.org/os/licensing.
12 10 # See the License for the specific language governing permissions
13 11 # and limitations under the License.
14 12 #
15 13 # When distributing Covered Code, include this CDDL HEADER in each
16 14 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17 15 # If applicable, add the following below this CDDL HEADER, with the
18 16 # fields enclosed by brackets "[]" replaced with your own identifying
19 17 # information: Portions Copyright [yyyy] [name of copyright owner]
20 18 #
21 19 # CDDL HEADER END
22 20 #
23 21
24 -# DO NOT EDIT -- this file is generated by the Event Registry.
25 22 #
23 +# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
24 +# Copyright 2018 Nexenta Systems, Inc.
26 25 #
27 -# code: SMF-8000-05
28 -# keys: defect.sunos.smf.svc.disabled
26 +
29 27 #
30 -msgid "SMF-8000-05.type"
31 -msgstr "XXX"
32 -msgid "SMF-8000-05.severity"
33 -msgstr "XXX"
34 -msgid "SMF-8000-05.description"
35 -msgstr "XXX Refer to %s for more information."
36 -msgid "SMF-8000-05.response"
37 -msgstr "XXX"
38 -msgid "SMF-8000-05.impact"
39 -msgstr "XXX"
40 -msgid "SMF-8000-05.action"
41 -msgstr "XXX"
42 -#
43 -# code: SMF-8000-1S
44 -# keys: defect.sunos.smf.svc.temporarily_disabled
45 -#
46 -msgid "SMF-8000-1S.type"
47 -msgstr "XXX"
48 -msgid "SMF-8000-1S.severity"
49 -msgstr "XXX"
50 -msgid "SMF-8000-1S.description"
51 -msgstr "XXX Refer to %s for more information."
52 -msgid "SMF-8000-1S.response"
53 -msgstr "XXX"
54 -msgid "SMF-8000-1S.impact"
55 -msgstr "XXX"
56 -msgid "SMF-8000-1S.action"
57 -msgstr "XXX"
58 -#
59 -# code: SMF-8000-2A
60 -# keys: defect.sunos.smf.svc.invalid_restarter
61 -#
62 -msgid "SMF-8000-2A.type"
63 -msgstr "XXX"
64 -msgid "SMF-8000-2A.severity"
65 -msgstr "XXX"
66 -msgid "SMF-8000-2A.description"
67 -msgstr "XXX Refer to %s for more information."
68 -msgid "SMF-8000-2A.response"
69 -msgstr "XXX"
70 -msgid "SMF-8000-2A.impact"
71 -msgstr "XXX"
72 -msgid "SMF-8000-2A.action"
73 -msgstr "XXX"
74 -#
75 -# code: SMF-8000-3P
76 -# keys: defect.sunos.smf.svc.restarter_absent
77 -#
78 -msgid "SMF-8000-3P.type"
79 -msgstr "XXX"
80 -msgid "SMF-8000-3P.severity"
81 -msgstr "XXX"
82 -msgid "SMF-8000-3P.description"
83 -msgstr "XXX Refer to %s for more information."
84 -msgid "SMF-8000-3P.response"
85 -msgstr "XXX"
86 -msgid "SMF-8000-3P.impact"
87 -msgstr "XXX"
88 -msgid "SMF-8000-3P.action"
89 -msgstr "XXX"
90 -#
91 -# code: SMF-8000-4D
92 -# keys: defect.sunos.smf.svc.uninitialized
93 -#
94 -msgid "SMF-8000-4D.type"
95 -msgstr "XXX"
96 -msgid "SMF-8000-4D.severity"
97 -msgstr "XXX"
98 -msgid "SMF-8000-4D.description"
99 -msgstr "XXX Refer to %s for more information."
100 -msgid "SMF-8000-4D.response"
101 -msgstr "XXX"
102 -msgid "SMF-8000-4D.impact"
103 -msgstr "XXX"
104 -msgid "SMF-8000-4D.action"
105 -msgstr "XXX"
106 -#
107 -# code: SMF-8000-5H
108 -# keys: defect.sunos.smf.svc.restarter_dead
109 -#
110 -msgid "SMF-8000-5H.type"
111 -msgstr "XXX"
112 -msgid "SMF-8000-5H.severity"
113 -msgstr "XXX"
114 -msgid "SMF-8000-5H.description"
115 -msgstr "XXX Refer to %s for more information."
116 -msgid "SMF-8000-5H.response"
117 -msgstr "XXX"
118 -msgid "SMF-8000-5H.impact"
119 -msgstr "XXX"
120 -msgid "SMF-8000-5H.action"
121 -msgstr "XXX"
122 -#
123 -# code: SMF-8000-63
124 -# keys: defect.sunos.smf.svc.administrative_request
125 -#
126 -msgid "SMF-8000-63.type"
127 -msgstr "XXX"
128 -msgid "SMF-8000-63.severity"
129 -msgstr "XXX"
130 -msgid "SMF-8000-63.description"
131 -msgstr "XXX Refer to %s for more information."
132 -msgid "SMF-8000-63.response"
133 -msgstr "XXX"
134 -msgid "SMF-8000-63.impact"
135 -msgstr "XXX"
136 -msgid "SMF-8000-63.action"
137 -msgstr "XXX"
138 -#
139 -# code: SMF-8000-7Y
140 -# keys: defect.sunos.smf.svc.fault_threshold_reached
141 -#
142 -msgid "SMF-8000-7Y.type"
143 -msgstr "XXX"
144 -msgid "SMF-8000-7Y.severity"
145 -msgstr "XXX"
146 -msgid "SMF-8000-7Y.description"
147 -msgstr "XXX Refer to %s for more information."
148 -msgid "SMF-8000-7Y.response"
149 -msgstr "XXX"
150 -msgid "SMF-8000-7Y.impact"
151 -msgstr "XXX"
152 -msgid "SMF-8000-7Y.action"
153 -msgstr "XXX"
154 -#
155 -# code: SMF-8000-8Q
156 -# keys: defect.sunos.smf.svc.method_fail
157 -#
158 -msgid "SMF-8000-8Q.type"
159 -msgstr "XXX"
160 -msgid "SMF-8000-8Q.severity"
161 -msgstr "XXX"
162 -msgid "SMF-8000-8Q.description"
163 -msgstr "XXX Refer to %s for more information."
164 -msgid "SMF-8000-8Q.response"
165 -msgstr "XXX"
166 -msgid "SMF-8000-8Q.impact"
167 -msgstr "XXX"
168 -msgid "SMF-8000-8Q.action"
169 -msgstr "XXX"
170 -#
171 -# code: SMF-8000-9C
172 -# keys: defect.sunos.smf.svc.none
173 -#
174 -msgid "SMF-8000-9C.type"
175 -msgstr "XXX"
176 -msgid "SMF-8000-9C.severity"
177 -msgstr "XXX"
178 -msgid "SMF-8000-9C.description"
179 -msgstr "XXX Refer to %s for more information."
180 -msgid "SMF-8000-9C.response"
181 -msgstr "XXX"
182 -msgid "SMF-8000-9C.impact"
183 -msgstr "XXX"
184 -msgid "SMF-8000-9C.action"
185 -msgstr "XXX"
186 -#
187 -# code: SMF-8000-AR
188 -# keys: defect.sunos.smf.svc.unknown
189 -#
190 -msgid "SMF-8000-AR.type"
191 -msgstr "XXX"
192 -msgid "SMF-8000-AR.severity"
193 -msgstr "XXX"
194 -msgid "SMF-8000-AR.description"
195 -msgstr "XXX Refer to %s for more information."
196 -msgid "SMF-8000-AR.response"
197 -msgstr "XXX"
198 -msgid "SMF-8000-AR.impact"
199 -msgstr "XXX"
200 -msgid "SMF-8000-AR.action"
201 -msgstr "XXX"
202 -#
203 -# code: SMF-8000-C4
204 -# keys: defect.sunos.smf.svc.starting
205 -#
206 -msgid "SMF-8000-C4.type"
207 -msgstr "XXX"
208 -msgid "SMF-8000-C4.severity"
209 -msgstr "XXX"
210 -msgid "SMF-8000-C4.description"
211 -msgstr "XXX Refer to %s for more information."
212 -msgid "SMF-8000-C4.response"
213 -msgstr "XXX"
214 -msgid "SMF-8000-C4.impact"
215 -msgstr "XXX"
216 -msgid "SMF-8000-C4.action"
217 -msgstr "XXX"
218 -#
219 -# code: SMF-8000-DX
220 -# keys: defect.sunos.smf.svc.administrative_degraded
221 -#
222 -msgid "SMF-8000-DX.type"
223 -msgstr "XXX"
224 -msgid "SMF-8000-DX.severity"
225 -msgstr "XXX"
226 -msgid "SMF-8000-DX.description"
227 -msgstr "XXX Refer to %s for more information."
228 -msgid "SMF-8000-DX.response"
229 -msgstr "XXX"
230 -msgid "SMF-8000-DX.impact"
231 -msgstr "XXX"
232 -msgid "SMF-8000-DX.action"
233 -msgstr "XXX"
234 -#
235 -# code: SMF-8000-E2
236 -# keys: defect.sunos.smf.svc.dependency_absent
237 -#
238 -msgid "SMF-8000-E2.type"
239 -msgstr "XXX"
240 -msgid "SMF-8000-E2.severity"
241 -msgstr "XXX"
242 -msgid "SMF-8000-E2.description"
243 -msgstr "XXX Refer to %s for more information."
244 -msgid "SMF-8000-E2.response"
245 -msgstr "XXX"
246 -msgid "SMF-8000-E2.impact"
247 -msgstr "XXX"
248 -msgid "SMF-8000-E2.action"
249 -msgstr "XXX"
250 -#
251 -# code: SMF-8000-FJ
252 -# keys: defect.sunos.smf.svc.dependency_running
253 -#
254 -msgid "SMF-8000-FJ.type"
255 -msgstr "XXX"
256 -msgid "SMF-8000-FJ.severity"
257 -msgstr "XXX"
258 -msgid "SMF-8000-FJ.description"
259 -msgstr "XXX Refer to %s for more information."
260 -msgid "SMF-8000-FJ.response"
261 -msgstr "XXX"
262 -msgid "SMF-8000-FJ.impact"
263 -msgstr "XXX"
264 -msgid "SMF-8000-FJ.action"
265 -msgstr "XXX"
266 -#
267 -# code: SMF-8000-GE
268 -# keys: defect.sunos.smf.svc.dependency_other
269 -#
270 -msgid "SMF-8000-GE.type"
271 -msgstr "XXX"
272 -msgid "SMF-8000-GE.severity"
273 -msgstr "XXX"
274 -msgid "SMF-8000-GE.description"
275 -msgstr "XXX Refer to %s for more information."
276 -msgid "SMF-8000-GE.response"
277 -msgstr "XXX"
278 -msgid "SMF-8000-GE.impact"
279 -msgstr "XXX"
280 -msgid "SMF-8000-GE.action"
281 -msgstr "XXX"
282 -#
283 -# code: SMF-8000-HP
284 -# keys: defect.sunos.smf.svc.dependency_cycle
285 -#
286 -msgid "SMF-8000-HP.type"
287 -msgstr "XXX"
288 -msgid "SMF-8000-HP.severity"
289 -msgstr "XXX"
290 -msgid "SMF-8000-HP.description"
291 -msgstr "XXX Refer to %s for more information."
292 -msgid "SMF-8000-HP.response"
293 -msgstr "XXX"
294 -msgid "SMF-8000-HP.impact"
295 -msgstr "XXX"
296 -msgid "SMF-8000-HP.action"
297 -msgstr "XXX"
298 -#
299 -# code: SMF-8000-JA
300 -# keys: defect.sunos.smf.svc.invalid_dependency
301 -#
302 -msgid "SMF-8000-JA.type"
303 -msgstr "XXX"
304 -msgid "SMF-8000-JA.severity"
305 -msgstr "XXX"
306 -msgid "SMF-8000-JA.description"
307 -msgstr "XXX Refer to %s for more information."
308 -msgid "SMF-8000-JA.response"
309 -msgstr "XXX"
310 -msgid "SMF-8000-JA.impact"
311 -msgstr "XXX"
312 -msgid "SMF-8000-JA.action"
313 -msgstr "XXX"
314 -#
315 -# code: SMF-8000-KS
316 -# keys: defect.sunos.smf.svc.start_method_fail
317 -#
318 -msgid "SMF-8000-KS.type"
319 -msgstr "XXX"
320 -msgid "SMF-8000-KS.severity"
321 -msgstr "XXX"
322 -msgid "SMF-8000-KS.description"
323 -msgstr "XXX Refer to %s for more information."
324 -msgid "SMF-8000-KS.response"
325 -msgstr "XXX"
326 -msgid "SMF-8000-KS.impact"
327 -msgstr "XXX"
328 -msgid "SMF-8000-KS.action"
329 -msgstr "XXX"
330 -#
331 -# code: SMF-8000-L5
332 -# keys: defect.sunos.smf.svc.restarting_too_quickly
333 -#
334 -msgid "SMF-8000-L5.type"
335 -msgstr "XXX"
336 -msgid "SMF-8000-L5.severity"
337 -msgstr "XXX"
338 -msgid "SMF-8000-L5.description"
339 -msgstr "XXX Refer to %s for more information."
340 -msgid "SMF-8000-L5.response"
341 -msgstr "XXX"
342 -msgid "SMF-8000-L5.impact"
343 -msgstr "XXX"
344 -msgid "SMF-8000-L5.action"
345 -msgstr "XXX"
346 -#
347 -# code: SMF-8000-MY
348 -# keys: defect.sunos.smf.db.verify
349 -#
350 -msgid "SMF-8000-MY.type"
351 -msgstr "XXX"
352 -msgid "SMF-8000-MY.severity"
353 -msgstr "XXX"
354 -msgid "SMF-8000-MY.description"
355 -msgstr "XXX Refer to %s for more information."
356 -msgid "SMF-8000-MY.response"
357 -msgstr "XXX"
358 -msgid "SMF-8000-MY.impact"
359 -msgstr "XXX"
360 -msgid "SMF-8000-MY.action"
361 -msgstr "XXX"
362 -#
363 -# code: SMF-8000-N3
364 -# keys: defect.sunos.smf.svc.bad_repo_state
365 -#
366 -msgid "SMF-8000-N3.type"
367 -msgstr "XXX"
368 -msgid "SMF-8000-N3.severity"
369 -msgstr "XXX"
370 -msgid "SMF-8000-N3.description"
371 -msgstr "XXX Refer to %s for more information."
372 -msgid "SMF-8000-N3.response"
373 -msgstr "XXX"
374 -msgid "SMF-8000-N3.impact"
375 -msgstr "XXX"
376 -msgid "SMF-8000-N3.action"
377 -msgstr "XXX"
378 -#
379 -# code: SMF-8000-PH
380 -# keys: defect.sunos.smf.svc.transitioning
381 -#
382 -msgid "SMF-8000-PH.type"
383 -msgstr "XXX"
384 -msgid "SMF-8000-PH.severity"
385 -msgstr "XXX"
386 -msgid "SMF-8000-PH.description"
387 -msgstr "XXX Refer to %s for more information."
388 -msgid "SMF-8000-PH.response"
389 -msgstr "XXX"
390 -msgid "SMF-8000-PH.impact"
391 -msgstr "XXX"
392 -msgid "SMF-8000-PH.action"
393 -msgstr "XXX"
394 -#
395 -# code: SMF-8000-QD
396 -# keys: defect.sunos.smf.info.recovery
397 -#
398 -msgid "SMF-8000-QD.type"
399 -msgstr "XXX"
400 -msgid "SMF-8000-QD.severity"
401 -msgstr "XXX"
402 -msgid "SMF-8000-QD.description"
403 -msgstr "XXX Refer to %s for more information."
404 -msgid "SMF-8000-QD.response"
405 -msgstr "XXX"
406 -msgid "SMF-8000-QD.impact"
407 -msgstr "XXX"
408 -msgid "SMF-8000-QD.action"
409 -msgstr "XXX"
410 -#
411 -# code: SMF-8000-R4
412 -# keys: defect.sunos.smf.svc.service_request
413 -#
414 -msgid "SMF-8000-R4.type"
415 -msgstr "XXX"
416 -msgid "SMF-8000-R4.severity"
417 -msgstr "XXX"
418 -msgid "SMF-8000-R4.description"
419 -msgstr "XXX Refer to %s for more information."
420 -msgid "SMF-8000-R4.response"
421 -msgstr "XXX"
422 -msgid "SMF-8000-R4.impact"
423 -msgstr "XXX"
424 -msgid "SMF-8000-R4.action"
425 -msgstr "XXX"
426 -#
427 28 # code: SMF-8000-SR
428 29 # keys: ireport.os.smf.state-transition.offline
429 30 #
430 31 msgid "SMF-8000-SR.type"
431 32 msgstr "XXX"
432 33 msgid "SMF-8000-SR.severity"
433 34 msgstr "minor"
434 35 msgid "SMF-8000-SR.description"
435 -msgstr "The indicated service has transitioned to the offline state\n Refer to %s for more information."
36 +msgstr "The indicated service has transitioned to the offline state."
436 37 msgid "SMF-8000-SR.response"
437 38 msgstr "XXX"
438 39 msgid "SMF-8000-SR.impact"
439 40 msgstr "Functionality provided by the offline service is unavailable."
440 41 msgid "SMF-8000-SR.action"
441 42 msgstr "XXX"
442 43 #
443 44 # code: SMF-8000-TC
444 45 # keys: ireport.os.smf.state-transition.online
445 46 #
446 47 msgid "SMF-8000-TC.type"
447 48 msgstr "XXX"
448 49 msgid "SMF-8000-TC.severity"
449 50 msgstr "minor"
450 51 msgid "SMF-8000-TC.description"
451 -msgstr "The indicated service has transitioned to the online state\n Refer to %s for more information."
52 +msgstr "The indicated service has transitioned to the online state."
452 53 msgid "SMF-8000-TC.response"
453 54 msgstr "XXX"
454 55 msgid "SMF-8000-TC.impact"
455 56 msgstr "Functionality provided by the service is now available."
456 57 msgid "SMF-8000-TC.action"
457 58 msgstr "XXX"
458 59 #
459 60 # code: SMF-8000-UQ
460 61 # keys: ireport.os.smf.state-transition.disabled
461 62 #
462 63 msgid "SMF-8000-UQ.type"
463 64 msgstr "XXX"
464 65 msgid "SMF-8000-UQ.severity"
465 66 msgstr "minor"
466 67 msgid "SMF-8000-UQ.description"
467 -msgstr "The indicated service has transitioned to the disabled state\n Refer to %s for more information."
68 +msgstr "The indicated service has transitioned to the disabled state."
468 69 msgid "SMF-8000-UQ.response"
469 70 msgstr "XXX"
470 71 msgid "SMF-8000-UQ.impact"
471 72 msgstr "Functionality provided by the service is unavailable."
472 73 msgid "SMF-8000-UQ.action"
473 74 msgstr "XXX"
474 75 #
475 76 # code: SMF-8000-VE
476 77 # keys: ireport.os.smf.state-transition.degraded
477 78 #
478 79 msgid "SMF-8000-VE.type"
479 80 msgstr "XXX"
480 81 msgid "SMF-8000-VE.severity"
481 82 msgstr "minor"
482 83 msgid "SMF-8000-VE.description"
483 -msgstr "The indicated service has transitioned to the degraded state\n Refer to %s for more information."
84 +msgstr "The indicated service has transitioned to the degraded state."
484 85 msgid "SMF-8000-VE.response"
485 86 msgstr "XXX"
486 87 msgid "SMF-8000-VE.impact"
487 88 msgstr "Some functionality provided by the service may be unavailable."
488 89 msgid "SMF-8000-VE.action"
489 90 msgstr "XXX"
490 91 #
491 92 # code: SMF-8000-WJ
492 93 # keys: ireport.os.smf.state-transition.uninitialized
493 94 #
494 95 msgid "SMF-8000-WJ.type"
495 96 msgstr "XXX"
496 97 msgid "SMF-8000-WJ.severity"
497 98 msgstr "minor"
498 99 msgid "SMF-8000-WJ.description"
499 -msgstr "The indicated service has transitioned to the uninitialized state\n Refer to %s for more information."
100 +msgstr "The indicated service has transitioned to the uninitialized state."
500 101 msgid "SMF-8000-WJ.response"
501 102 msgstr "XXX"
502 103 msgid "SMF-8000-WJ.impact"
503 104 msgstr "Functionality provided by the service is unavailable."
504 105 msgid "SMF-8000-WJ.action"
505 106 msgstr "XXX"
506 107 #
507 108 # code: SMF-8000-X2
508 109 # keys: ireport.os.smf.state-transition.maintenance
509 110 #
510 111 msgid "SMF-8000-X2.type"
511 112 msgstr "XXX"
512 113 msgid "SMF-8000-X2.severity"
513 114 msgstr "major"
514 115 msgid "SMF-8000-X2.description"
515 -msgstr "The indicated service has transitioned to the maintenance state\n Refer to %s for more information."
116 +msgstr "The indicated service has transitioned to the maintenance state."
516 117 msgid "SMF-8000-X2.response"
517 118 msgstr "XXX"
518 119 msgid "SMF-8000-X2.impact"
519 120 msgstr "Functionality provided by the service is unavailable."
520 121 msgid "SMF-8000-X2.action"
521 122 msgstr "XXX"
522 123 #
523 124 # code: SMF-8000-YX
524 125 # keys: defect.sunos.smf.svc.maintenance
525 126 #
526 127 msgid "SMF-8000-YX.type"
527 128 msgstr "defect"
528 129 msgid "SMF-8000-YX.severity"
529 130 msgstr "major"
530 131 msgid "SMF-8000-YX.description"
531 -msgstr "A service failed - %<fault-list[0].reason-long>.\n Refer to %s for more information."
132 +msgstr "A service failed."
532 133 msgid "SMF-8000-YX.response"
533 134 msgstr "The service has been placed into the maintenance state."
534 135 msgid "SMF-8000-YX.impact"
535 136 msgstr "%<fault-list[0].svc-string> is unavailable."
536 137 msgid "SMF-8000-YX.action"
537 -msgstr "Run 'svcs -xv %<fault-list[0].svc-string>' to determine the generic reason why the service failed, the location of any logfiles, and a list of other services impacted."
138 +msgstr "Determine the generic reason why the service failed, the location of any logfiles, and a list of other services impacted."
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX