Print this page
8024 mdb_ctf_vread() needn't be so strict about unions
Reviewed by: Matthew Ahrens <mahrens@delphix.com>
Reviewed by: Pavel Zakharov <pavel.zakharov@delphix.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Approved by: Dan McDonald <danmcd@omniti.com>
NEX-6850 FMA messages need updating, badly
Reviewed by: Cynthia Eastham <cynthia.eastham@nexenta.com>

Split Close
Expand all
Collapse all
          --- old/usr/src/cmd/fm/dicts/SENSOR.po
          +++ new/usr/src/cmd/fm/dicts/SENSOR.po
   1    1  #
   2      -# Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
   3      -# Use is subject to license terms.
   4      -#
   5    2  # CDDL HEADER START
   6    3  #
   7    4  # The contents of this file are subject to the terms of the
   8    5  # Common Development and Distribution License (the "License").
   9    6  # You may not use this file except in compliance with the License.
  10    7  #
  11    8  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12    9  # or http://www.opensolaris.org/os/licensing.
  13   10  # See the License for the specific language governing permissions
  14   11  # and limitations under the License.
  15   12  #
  16   13  # When distributing Covered Code, include this CDDL HEADER in each
  17   14  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18   15  # If applicable, add the following below this CDDL HEADER, with the
  19   16  # fields enclosed by brackets "[]" replaced with your own identifying
  20   17  # information: Portions Copyright [yyyy] [name of copyright owner]
  21   18  #
  22   19  # CDDL HEADER END
  23   20  #
  24      -# DO NOT EDIT -- this file is generated by the Event Registry.
       21 +
  25   22  #
       23 +# Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
       24 +# Use is subject to license terms.
       25 +# Copyright 2017 Nexenta Systems, Inc.
  26   26  #
       27 +
       28 +#
  27   29  # code: SENSOR-8000-09
  28   30  # keys: fault.sensor.fan.failed
  29   31  #
  30   32  msgid "SENSOR-8000-09.type"
  31   33  msgstr "Fault"
  32   34  msgid "SENSOR-8000-09.severity"
  33   35  msgstr "Minor"
  34   36  msgid "SENSOR-8000-09.description"
  35      -msgstr "External sensors indicate that a fan is no longer operating\ncorrectly.  Refer to %s for more information."
       37 +msgstr "External sensors indicate that a fan is no longer operating correctly."
  36   38  msgid "SENSOR-8000-09.response"
  37   39  msgstr "None."
  38   40  msgid "SENSOR-8000-09.impact"
  39      -msgstr "The enclosure may be getting inadequate cooling.  If the problem\npersists, the components may overheat and the enclosure may shutdown."
       41 +msgstr "The enclosure may be getting inadequate cooling.  If the problem persists, the components may overheat and the enclosure may shutdown."
  40   42  msgid "SENSOR-8000-09.action"
  41      -msgstr "Check the fan to see if the fan has lost power or there is a\nphysical obstruction.  Replace the fan if the internal mechanism has failed.\n"
       43 +msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed."
  42   44  #
  43   45  # code: SENSOR-8000-1N
  44   46  # keys: fault.sensor.psu.failed
  45   47  #
  46   48  msgid "SENSOR-8000-1N.type"
  47   49  msgstr "Fault"
  48   50  msgid "SENSOR-8000-1N.severity"
  49   51  msgstr "Minor"
  50   52  msgid "SENSOR-8000-1N.description"
  51      -msgstr "External sensors indicate that a power supply is no longer operating correctly.  Refer to %s for more information."
       53 +msgstr "External sensors indicate that a power supply is no longer operating correctly."
  52   54  msgid "SENSOR-8000-1N.response"
  53   55  msgstr "None."
  54   56  msgid "SENSOR-8000-1N.impact"
  55   57  msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
  56   58  msgid "SENSOR-8000-1N.action"
  57      -msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed.\n"
       59 +msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed."
  58   60  #
  59   61  # code: SENSOR-8000-26
  60   62  # keys: fault.fan.failed
  61   63  #
  62   64  msgid "SENSOR-8000-26.type"
  63   65  msgstr "Fault"
  64   66  msgid "SENSOR-8000-26.severity"
  65   67  msgstr "Minor"
  66   68  msgid "SENSOR-8000-26.description"
  67      -msgstr "External sensors indicate that a fan is no longer operating correctly.  Refer to %s for more information."
       69 +msgstr "External sensors indicate that a fan is no longer operating correctly."
  68   70  msgid "SENSOR-8000-26.response"
  69   71  msgstr "None."
  70   72  msgid "SENSOR-8000-26.impact"
  71   73  msgstr "The enclosure may be getting inadequate cooling.  If the problem persists, the components may overheat and the enclosure may shutdown."
  72   74  msgid "SENSOR-8000-26.action"
  73      -msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed.\n"
       75 +msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed."
  74   76  #
  75   77  # code: SENSOR-8000-3T
  76   78  # keys: fault.psu.failed
  77   79  #
  78   80  msgid "SENSOR-8000-3T.type"
  79   81  msgstr "Fault"
  80   82  msgid "SENSOR-8000-3T.severity"
  81   83  msgstr "Major"
  82   84  msgid "SENSOR-8000-3T.description"
  83      -msgstr "External sensors indicate that a power supply is no longer operating correctly.  Refer to %s for more information."
       85 +msgstr "External sensors indicate that a power supply is no longer operating correctly."
  84   86  msgid "SENSOR-8000-3T.response"
  85   87  msgstr "None."
  86   88  msgid "SENSOR-8000-3T.impact"
  87   89  msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
  88   90  msgid "SENSOR-8000-3T.action"
  89      -msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed.\n"
       91 +msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed."
  90   92  #
  91   93  # code: SENSOR-8000-40
  92   94  # keys: fault.fan.failed-pred
  93   95  #
  94   96  msgid "SENSOR-8000-40.type"
  95   97  msgstr "Fault"
  96   98  msgid "SENSOR-8000-40.severity"
  97   99  msgstr "Minor"
  98  100  msgid "SENSOR-8000-40.description"
  99      -msgstr "A preditive failure sensor indicates that this fan has either failed or that a failure is imminent.\n     Refer to %s for more information."
      101 +msgstr "A preditive failure sensor indicates that this fan has either failed or that a failure is imminent."
 100  102  msgid "SENSOR-8000-40.response"
 101  103  msgstr "None."
 102  104  msgid "SENSOR-8000-40.impact"
 103  105  msgstr "The enclosure may be getting inadequate cooling.  If the problem persists, the components may overheat and the enclosure may shutdown."
 104  106  msgid "SENSOR-8000-40.action"
 105      -msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed.\n"
      107 +msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed."
 106  108  #
 107  109  # code: SENSOR-8000-5V
 108  110  # keys: fault.psu.failed-pred
 109  111  #
 110  112  msgid "SENSOR-8000-5V.type"
 111  113  msgstr "Fault"
 112  114  msgid "SENSOR-8000-5V.severity"
 113  115  msgstr "Minor"
 114  116  msgid "SENSOR-8000-5V.description"
 115      -msgstr "A preditive failure sensor indicates that this power supply has either failed or that a failure is imminent.  Refer to %s for more information."
      117 +msgstr "A preditive failure sensor indicates that this power supply has either failed or that a failure is imminent."
 116  118  msgid "SENSOR-8000-5V.response"
 117  119  msgstr "None."
 118  120  msgid "SENSOR-8000-5V.impact"
 119  121  msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
 120  122  msgid "SENSOR-8000-5V.action"
 121      -msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed.\n"
      123 +msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed."
 122  124  #
 123  125  # code: SENSOR-8000-6G
 124  126  # keys: fault.psu.failed-int
 125  127  #
 126  128  msgid "SENSOR-8000-6G.type"
 127  129  msgstr "Fault"
 128  130  msgid "SENSOR-8000-6G.severity"
 129  131  msgstr "Major"
 130  132  msgid "SENSOR-8000-6G.description"
 131      -msgstr "A sensor indicates that this power supply has failed.  Refer to %s for more information."
      133 +msgstr "A sensor indicates that this power supply has failed."
 132  134  msgid "SENSOR-8000-6G.response"
 133  135  msgstr "None."
 134  136  msgid "SENSOR-8000-6G.impact"
 135  137  msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
 136  138  msgid "SENSOR-8000-6G.action"
 137      -msgstr "Replace the indicated power supply"
      139 +msgstr "Replace the indicated power supply."
 138  140  #
 139  141  # code: SENSOR-8000-7L
 140  142  # keys: fault.psu.failed-ext
 141  143  #
 142  144  msgid "SENSOR-8000-7L.type"
 143  145  msgstr "Fault"
 144  146  msgid "SENSOR-8000-7L.severity"
 145  147  msgstr "Major"
 146  148  msgid "SENSOR-8000-7L.description"
 147      -msgstr "A sensor indicates that this power supply is not operating properly due to some external condition  Refer to %s for more information."
      149 +msgstr "A sensor indicates that this power supply is not operating properly due to some external condition."
 148  150  msgid "SENSOR-8000-7L.response"
 149  151  msgstr "None."
 150  152  msgid "SENSOR-8000-7L.impact"
 151  153  msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
 152  154  msgid "SENSOR-8000-7L.action"
 153      -msgstr "Check to see if the power cord is connected properly or if there are other conditions that may be causing inadequate power to be provided to the indicated power supply.\n"
      155 +msgstr "Check to see if the power cord is connected properly or if there are other conditions that may be causing inadequate power to be provided to the indicated power supply."
    