1 #
   2 # CDDL HEADER START
   3 #
   4 # The contents of this file are subject to the terms of the
   5 # Common Development and Distribution License (the "License").
   6 # You may not use this file except in compliance with the License.
   7 #
   8 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
   9 # or http://www.opensolaris.org/os/licensing.
  10 # See the License for the specific language governing permissions
  11 # and limitations under the License.
  12 #
  13 # When distributing Covered Code, include this CDDL HEADER in each
  14 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  15 # If applicable, add the following below this CDDL HEADER, with the
  16 # fields enclosed by brackets "[]" replaced with your own identifying
  17 # information: Portions Copyright [yyyy] [name of copyright owner]
  18 #
  19 # CDDL HEADER END
  20 #
  21 
  22 #
  23 # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
  24 # Use is subject to license terms.
  25 # Copyright 2017 Nexenta Systems, Inc.
  26 #
  27 
  28 #
  29 # code: SENSOR-8000-09
  30 # keys: fault.sensor.fan.failed
  31 #
  32 msgid "SENSOR-8000-09.type"
  33 msgstr "Fault"
  34 msgid "SENSOR-8000-09.severity"
  35 msgstr "Minor"
  36 msgid "SENSOR-8000-09.description"
  37 msgstr "External sensors indicate that a fan is no longer operating correctly."
  38 msgid "SENSOR-8000-09.response"
  39 msgstr "None."
  40 msgid "SENSOR-8000-09.impact"
  41 msgstr "The enclosure may be getting inadequate cooling.  If the problem persists, the components may overheat and the enclosure may shutdown."
  42 msgid "SENSOR-8000-09.action"
  43 msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed."
  44 #
  45 # code: SENSOR-8000-1N
  46 # keys: fault.sensor.psu.failed
  47 #
  48 msgid "SENSOR-8000-1N.type"
  49 msgstr "Fault"
  50 msgid "SENSOR-8000-1N.severity"
  51 msgstr "Minor"
  52 msgid "SENSOR-8000-1N.description"
  53 msgstr "External sensors indicate that a power supply is no longer operating correctly."
  54 msgid "SENSOR-8000-1N.response"
  55 msgstr "None."
  56 msgid "SENSOR-8000-1N.impact"
  57 msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
  58 msgid "SENSOR-8000-1N.action"
  59 msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed."
  60 #
  61 # code: SENSOR-8000-26
  62 # keys: fault.fan.failed
  63 #
  64 msgid "SENSOR-8000-26.type"
  65 msgstr "Fault"
  66 msgid "SENSOR-8000-26.severity"
  67 msgstr "Minor"
  68 msgid "SENSOR-8000-26.description"
  69 msgstr "External sensors indicate that a fan is no longer operating correctly."
  70 msgid "SENSOR-8000-26.response"
  71 msgstr "None."
  72 msgid "SENSOR-8000-26.impact"
  73 msgstr "The enclosure may be getting inadequate cooling.  If the problem persists, the components may overheat and the enclosure may shutdown."
  74 msgid "SENSOR-8000-26.action"
  75 msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed."
  76 #
  77 # code: SENSOR-8000-3T
  78 # keys: fault.psu.failed
  79 #
  80 msgid "SENSOR-8000-3T.type"
  81 msgstr "Fault"
  82 msgid "SENSOR-8000-3T.severity"
  83 msgstr "Major"
  84 msgid "SENSOR-8000-3T.description"
  85 msgstr "External sensors indicate that a power supply is no longer operating correctly."
  86 msgid "SENSOR-8000-3T.response"
  87 msgstr "None."
  88 msgid "SENSOR-8000-3T.impact"
  89 msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
  90 msgid "SENSOR-8000-3T.action"
  91 msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed."
  92 #
  93 # code: SENSOR-8000-40
  94 # keys: fault.fan.failed-pred
  95 #
  96 msgid "SENSOR-8000-40.type"
  97 msgstr "Fault"
  98 msgid "SENSOR-8000-40.severity"
  99 msgstr "Minor"
 100 msgid "SENSOR-8000-40.description"
 101 msgstr "A preditive failure sensor indicates that this fan has either failed or that a failure is imminent."
 102 msgid "SENSOR-8000-40.response"
 103 msgstr "None."
 104 msgid "SENSOR-8000-40.impact"
 105 msgstr "The enclosure may be getting inadequate cooling.  If the problem persists, the components may overheat and the enclosure may shutdown."
 106 msgid "SENSOR-8000-40.action"
 107 msgstr "Check the fan to see if the fan has lost power or there is a physical obstruction.  Replace the fan if the internal mechanism has failed."
 108 #
 109 # code: SENSOR-8000-5V
 110 # keys: fault.psu.failed-pred
 111 #
 112 msgid "SENSOR-8000-5V.type"
 113 msgstr "Fault"
 114 msgid "SENSOR-8000-5V.severity"
 115 msgstr "Minor"
 116 msgid "SENSOR-8000-5V.description"
 117 msgstr "A preditive failure sensor indicates that this power supply has either failed or that a failure is imminent."
 118 msgid "SENSOR-8000-5V.response"
 119 msgstr "None."
 120 msgid "SENSOR-8000-5V.impact"
 121 msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
 122 msgid "SENSOR-8000-5V.action"
 123 msgstr "Check to see if the power cord is connected properly.  Replace the power supply if the internal mechanism has failed."
 124 #
 125 # code: SENSOR-8000-6G
 126 # keys: fault.psu.failed-int
 127 #
 128 msgid "SENSOR-8000-6G.type"
 129 msgstr "Fault"
 130 msgid "SENSOR-8000-6G.severity"
 131 msgstr "Major"
 132 msgid "SENSOR-8000-6G.description"
 133 msgstr "A sensor indicates that this power supply has failed."
 134 msgid "SENSOR-8000-6G.response"
 135 msgstr "None."
 136 msgid "SENSOR-8000-6G.impact"
 137 msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
 138 msgid "SENSOR-8000-6G.action"
 139 msgstr "Replace the indicated power supply."
 140 #
 141 # code: SENSOR-8000-7L
 142 # keys: fault.psu.failed-ext
 143 #
 144 msgid "SENSOR-8000-7L.type"
 145 msgstr "Fault"
 146 msgid "SENSOR-8000-7L.severity"
 147 msgstr "Major"
 148 msgid "SENSOR-8000-7L.description"
 149 msgstr "A sensor indicates that this power supply is not operating properly due to some external condition."
 150 msgid "SENSOR-8000-7L.response"
 151 msgstr "None."
 152 msgid "SENSOR-8000-7L.impact"
 153 msgstr "The enclosure may be getting inadequate power.  Subsequent loss of power supplies may force the enclosure to shutdown."
 154 msgid "SENSOR-8000-7L.action"
 155 msgstr "Check to see if the power cord is connected properly or if there are other conditions that may be causing inadequate power to be provided to the indicated power supply."