Print this page
8024 mdb_ctf_vread() needn't be so strict about unions
Reviewed by: Matthew Ahrens <mahrens@delphix.com>
Reviewed by: Pavel Zakharov <pavel.zakharov@delphix.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Approved by: Dan McDonald <danmcd@omniti.com>
NEX-6850 FMA messages need updating, badly
Reviewed by: Cynthia Eastham <cynthia.eastham@nexenta.com>

Split Close
Expand all
Collapse all
          --- old/usr/src/cmd/fm/dicts/NXGE.po
          +++ new/usr/src/cmd/fm/dicts/NXGE.po
   1    1  #
   2      -# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
   3      -# Use is subject to license terms.
   4      -#
   5    2  # CDDL HEADER START
   6    3  #
   7    4  # The contents of this file are subject to the terms of the
   8    5  # Common Development and Distribution License (the "License").
   9    6  # You may not use this file except in compliance with the License.
  10    7  #
  11    8  # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12    9  # or http://www.opensolaris.org/os/licensing.
  13   10  # See the License for the specific language governing permissions
  14   11  # and limitations under the License.
  15   12  #
  16   13  # When distributing Covered Code, include this CDDL HEADER in each
  17   14  # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18   15  # If applicable, add the following below this CDDL HEADER, with the
  19   16  # fields enclosed by brackets "[]" replaced with your own identifying
  20   17  # information: Portions Copyright [yyyy] [name of copyright owner]
  21   18  #
  22   19  # CDDL HEADER END
  23   20  #
  24      -#ident  "%Z%%M% %I%     %E% SMI"
       21 +
  25   22  #
  26      -# DO NOT EDIT -- this file is generated by the Event Registry.
       23 +# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
       24 +# Use is subject to license terms.
       25 +# Copyright 2017 Nexenta Systems, Inc.
  27   26  #
       27 +
  28   28  #
  29   29  # code: NXGE-8000-0U
  30   30  # keys: fault.io.n2.niu-xfp
  31   31  #
  32   32  msgid "NXGE-8000-0U.type"
  33   33  msgstr "Fault"
  34   34  msgid "NXGE-8000-0U.severity"
  35   35  msgstr "Critical"
  36   36  msgid "NXGE-8000-0U.description"
  37      -msgstr "The XFP optical transceiver is broken or missing.\n  Refer to %s for more information."
       37 +msgstr "The XFP optical transceiver is broken or missing."
  38   38  msgid "NXGE-8000-0U.response"
  39      -msgstr "The device instance will be disabled.\n"
       39 +msgstr "The device instance will be disabled."
  40   40  msgid "NXGE-8000-0U.impact"
  41      -msgstr "Loss of services provided by the device instances\nassociated with this fault.\n"
       41 +msgstr "Loss of services provided by the device instances associated with this fault."
  42   42  msgid "NXGE-8000-0U.action"
  43      -msgstr "Check and make sure that the XFP optical transceiver\nis properly installed. If problem persists, schedule a repair\nprocedure to replace the affected device, which can be determined\nusing fmdump -v -u <EVENT_ID>\n"
       43 +msgstr "Check and make sure that the XFP optical transceiver is properly installed.  If problem persists, schedule a repair procedure to replace the affected device."
  44   44  #
  45   45  # code: NXGE-8000-17
  46   46  # keys: fault.io.n2.niu-xaui
  47   47  #
  48   48  msgid "NXGE-8000-17.type"
  49   49  msgstr "Fault"
  50   50  msgid "NXGE-8000-17.severity"
  51   51  msgstr "Critical"
  52   52  msgid "NXGE-8000-17.description"
  53      -msgstr "A fault in the XAUI component used for 10GbE networking. \n  Refer to %s for more information."
       53 +msgstr "A fault in the XAUI component used for 10GbE networking."
  54   54  msgid "NXGE-8000-17.response"
  55      -msgstr "The device instance will be disabled.\n"
       55 +msgstr "The device instance will be disabled."
  56   56  msgid "NXGE-8000-17.impact"
  57      -msgstr "Loss of services provided by the device instances\nassociated with this fault.\n"
       57 +msgstr "Loss of services provided by the device instances associated with this fault."
  58   58  msgid "NXGE-8000-17.action"
  59      -msgstr "Schedule a repair procedure for the affected device, which\ncan be determined using fmdump -v -u <EVENT_ID>\n"
       59 +msgstr "Schedule a repair procedure for the affected device."
    
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX