Print this page
8024 mdb_ctf_vread() needn't be so strict about unions
Reviewed by: Matthew Ahrens <mahrens@delphix.com>
Reviewed by: Pavel Zakharov <pavel.zakharov@delphix.com>
Reviewed by: Robert Mustacchi <rm@joyent.com>
Approved by: Dan McDonald <danmcd@omniti.com>
NEX-6850 FMA messages need updating, badly
Reviewed by: Cynthia Eastham <cynthia.eastham@nexenta.com>

@@ -1,9 +1,6 @@
 #
-# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
-# Use is subject to license terms.
-#
 # CDDL HEADER START
 #
 # The contents of this file are subject to the terms of the
 # Common Development and Distribution License (the "License").
 # You may not use this file except in compliance with the License.

@@ -19,41 +16,44 @@
 # fields enclosed by brackets "[]" replaced with your own identifying
 # information: Portions Copyright [yyyy] [name of copyright owner]
 #
 # CDDL HEADER END
 #
-#ident  "%Z%%M% %I%     %E% SMI"
+
 #
-# DO NOT EDIT -- this file is generated by the Event Registry.
+# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
+# Use is subject to license terms.
+# Copyright 2017 Nexenta Systems, Inc.
 #
+
 #
 # code: NXGE-8000-0U
 # keys: fault.io.n2.niu-xfp
 #
 msgid "NXGE-8000-0U.type"
 msgstr "Fault"
 msgid "NXGE-8000-0U.severity"
 msgstr "Critical"
 msgid "NXGE-8000-0U.description"
-msgstr "The XFP optical transceiver is broken or missing.\n  Refer to %s for more information."
+msgstr "The XFP optical transceiver is broken or missing."
 msgid "NXGE-8000-0U.response"
-msgstr "The device instance will be disabled.\n"
+msgstr "The device instance will be disabled."
 msgid "NXGE-8000-0U.impact"
-msgstr "Loss of services provided by the device instances\nassociated with this fault.\n"
+msgstr "Loss of services provided by the device instances associated with this fault."
 msgid "NXGE-8000-0U.action"
-msgstr "Check and make sure that the XFP optical transceiver\nis properly installed. If problem persists, schedule a repair\nprocedure to replace the affected device, which can be determined\nusing fmdump -v -u <EVENT_ID>\n"
+msgstr "Check and make sure that the XFP optical transceiver is properly installed.  If problem persists, schedule a repair procedure to replace the affected device."
 #
 # code: NXGE-8000-17
 # keys: fault.io.n2.niu-xaui
 #
 msgid "NXGE-8000-17.type"
 msgstr "Fault"
 msgid "NXGE-8000-17.severity"
 msgstr "Critical"
 msgid "NXGE-8000-17.description"
-msgstr "A fault in the XAUI component used for 10GbE networking. \n  Refer to %s for more information."
+msgstr "A fault in the XAUI component used for 10GbE networking."
 msgid "NXGE-8000-17.response"
-msgstr "The device instance will be disabled.\n"
+msgstr "The device instance will be disabled."
 msgid "NXGE-8000-17.impact"
-msgstr "Loss of services provided by the device instances\nassociated with this fault.\n"
+msgstr "Loss of services provided by the device instances associated with this fault."
 msgid "NXGE-8000-17.action"
-msgstr "Schedule a repair procedure for the affected device, which\ncan be determined using fmdump -v -u <EVENT_ID>\n"
+msgstr "Schedule a repair procedure for the affected device."