1 #
   2 # CDDL HEADER START
   3 #
   4 # The contents of this file are subject to the terms of the
   5 # Common Development and Distribution License (the "License").
   6 # You may not use this file except in compliance with the License.
   7 #
   8 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
   9 # or http://www.opensolaris.org/os/licensing.
  10 # See the License for the specific language governing permissions
  11 # and limitations under the License.
  12 #
  13 # When distributing Covered Code, include this CDDL HEADER in each
  14 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  15 # If applicable, add the following below this CDDL HEADER, with the
  16 # fields enclosed by brackets "[]" replaced with your own identifying
  17 # information: Portions Copyright [yyyy] [name of copyright owner]
  18 #
  19 # CDDL HEADER END
  20 #
  21 
  22 #
  23 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
  24 # Copyright 2017 Nexenta Systems, Inc.
  25 #
  26 
  27 #
  28 # General-purpose messages
  29 #
  30 msgid "syslog-msgs-message-template"
  31 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
  32 #
  33 # Fault-related messages
  34 #
  35 #
  36 #
  37 # code: FMD-8000-0W
  38 # keys: defect.sunos.fmd.nosub
  39 #
  40 msgid "FMD-8000-0W.type"
  41 msgstr "Defect"
  42 msgid "FMD-8000-0W.severity"
  43 msgstr "Minor"
  44 msgid "FMD-8000-0W.description"
  45 msgstr "The Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed."
  46 msgid "FMD-8000-0W.response"
  47 msgstr "Error reports from the component will be logged for examination."
  48 msgid "FMD-8000-0W.impact"
  49 msgstr "Automated diagnosis and response for these events will not occur."
  50 msgid "FMD-8000-0W.action"
  51 msgstr "Ensure that fault management software is installed properly."
  52 #
  53 # code: FMD-8000-11
  54 # keys: defect.sunos.fmd.nodiagcode
  55 #
  56 msgid "FMD-8000-11.type"
  57 msgstr "Defect"
  58 msgid "FMD-8000-11.severity"
  59 msgstr "Minor"
  60 msgid "FMD-8000-11.description"
  61 msgstr "A Fault Manager component generated a diagnosis for which no message summary exists."
  62 msgid "FMD-8000-11.response"
  63 msgstr "The diagnosis has been saved in the fault log for examination."
  64 msgid "FMD-8000-11.impact"
  65 msgstr "The fault log will need to be manually examined to determine if any human response is required."
  66 msgid "FMD-8000-11.action"
  67 msgstr "Ensure that fault management software is installed properly."
  68 #
  69 # code: FMD-8000-2K
  70 # keys: defect.sunos.fmd.module
  71 #
  72 msgid "FMD-8000-2K.type"
  73 msgstr "Defect"
  74 msgid "FMD-8000-2K.severity"
  75 msgstr "Minor"
  76 msgid "FMD-8000-2K.description"
  77 msgstr "A Fault Manager component has experienced an error that required the module to be disabled."
  78 msgid "FMD-8000-2K.response"
  79 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  80 msgid "FMD-8000-2K.impact"
  81 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  82 msgid "FMD-8000-2K.action"
  83 msgstr "Reset the module."
  84 #
  85 # code: FMD-8000-3F
  86 # keys: defect.sunos.fmd.config
  87 #
  88 msgid "FMD-8000-3F.type"
  89 msgstr "Defect"
  90 msgid "FMD-8000-3F.severity"
  91 msgstr "Minor"
  92 msgid "FMD-8000-3F.description"
  93 msgstr "A Fault Manager component could not load due to an erroroneous configuration file."
  94 msgid "FMD-8000-3F.response"
  95 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
  96 msgid "FMD-8000-3F.impact"
  97 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
  98 msgid "FMD-8000-3F.action"
  99 msgstr "Load the module after repairing its configuration."
 100 #
 101 # code: FMD-8000-4M
 102 # keys: list.repaired
 103 #
 104 msgid "FMD-8000-4M.type"
 105 msgstr "Repair"
 106 msgid "FMD-8000-4M.severity"
 107 msgstr "Minor"
 108 msgid "FMD-8000-4M.description"
 109 msgstr "All faults associated with an event id have been addressed."
 110 msgid "FMD-8000-4M.response"
 111 msgstr "Some system components offlined because of the original fault may have been brought back online."
 112 msgid "FMD-8000-4M.impact"
 113 msgstr "Performance degradation of the system due to the original fault may have been recovered."
 114 msgid "FMD-8000-4M.action"
 115 msgstr "None."
 116 #
 117 # code: FMD-8000-58
 118 # keys: list.updated
 119 #
 120 msgid "FMD-8000-58.type"
 121 msgstr "Update"
 122 msgid "FMD-8000-58.severity"
 123 msgstr "Minor"
 124 msgid "FMD-8000-58.description"
 125 msgstr "Some faults associated with an event id have been addressed."
 126 msgid "FMD-8000-58.response"
 127 msgstr "Some system components offlined because of the original fault may have been brought back online."
 128 msgid "FMD-8000-58.impact"
 129 msgstr "Performance degradation of the system due to the original fault may have been recovered."
 130 msgid "FMD-8000-58.action"
 131 msgstr "Identify the repaired components, and any suspects that still need to be repaired."
 132 #
 133 # code: FMD-8000-6U
 134 # keys: list.resolved
 135 #
 136 msgid "FMD-8000-6U.type"
 137 msgstr "Resolved"
 138 msgid "FMD-8000-6U.severity"
 139 msgstr "Minor"
 140 msgid "FMD-8000-6U.description"
 141 msgstr "All faults associated with an event id have been addressed."
 142 msgid "FMD-8000-6U.response"
 143 msgstr "All system components offlined because of the original fault have been brought back online."
 144 msgid "FMD-8000-6U.impact"
 145 msgstr "Performance degradation of the system due to the original fault has been recovered."
 146 msgid "FMD-8000-6U.action"
 147 msgstr "None."