1 # 2 # CDDL HEADER START 3 # 4 # The contents of this file are subject to the terms of the 5 # Common Development and Distribution License (the "License"). 6 # You may not use this file except in compliance with the License. 7 # 8 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 9 # or http://www.opensolaris.org/os/licensing. 10 # See the License for the specific language governing permissions 11 # and limitations under the License. 12 # 13 # When distributing Covered Code, include this CDDL HEADER in each 14 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 15 # If applicable, add the following below this CDDL HEADER, with the 16 # fields enclosed by brackets "[]" replaced with your own identifying 17 # information: Portions Copyright [yyyy] [name of copyright owner] 18 # 19 # CDDL HEADER END 20 # 21 22 # 23 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 24 # Copyright 2017 Nexenta Systems, Inc. 25 # 26 27 # 28 # General-purpose messages 29 # 30 msgid "syslog-msgs-message-template" 31 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 32 # 33 # Fault-related messages 34 # 35 # 36 # 37 # code: FMD-8000-0W 38 # keys: defect.sunos.fmd.nosub 39 # 40 msgid "FMD-8000-0W.type" 41 msgstr "Defect" 42 msgid "FMD-8000-0W.severity" 43 msgstr "Minor" 44 msgid "FMD-8000-0W.description" 45 msgstr "The Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed." 46 msgid "FMD-8000-0W.response" 47 msgstr "Error reports from the component will be logged for examination." 48 msgid "FMD-8000-0W.impact" 49 msgstr "Automated diagnosis and response for these events will not occur." 50 msgid "FMD-8000-0W.action" 51 msgstr "Ensure that fault management software is installed properly." 52 # 53 # code: FMD-8000-11 54 # keys: defect.sunos.fmd.nodiagcode 55 # 56 msgid "FMD-8000-11.type" 57 msgstr "Defect" 58 msgid "FMD-8000-11.severity" 59 msgstr "Minor" 60 msgid "FMD-8000-11.description" 61 msgstr "A Fault Manager component generated a diagnosis for which no message summary exists." 62 msgid "FMD-8000-11.response" 63 msgstr "The diagnosis has been saved in the fault log for examination." 64 msgid "FMD-8000-11.impact" 65 msgstr "The fault log will need to be manually examined to determine if any human response is required." 66 msgid "FMD-8000-11.action" 67 msgstr "Ensure that fault management software is installed properly." 68 # 69 # code: FMD-8000-2K 70 # keys: defect.sunos.fmd.module 71 # 72 msgid "FMD-8000-2K.type" 73 msgstr "Defect" 74 msgid "FMD-8000-2K.severity" 75 msgstr "Minor" 76 msgid "FMD-8000-2K.description" 77 msgstr "A Fault Manager component has experienced an error that required the module to be disabled." 78 msgid "FMD-8000-2K.response" 79 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 80 msgid "FMD-8000-2K.impact" 81 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 82 msgid "FMD-8000-2K.action" 83 msgstr "Reset the module." 84 # 85 # code: FMD-8000-3F 86 # keys: defect.sunos.fmd.config 87 # 88 msgid "FMD-8000-3F.type" 89 msgstr "Defect" 90 msgid "FMD-8000-3F.severity" 91 msgstr "Minor" 92 msgid "FMD-8000-3F.description" 93 msgstr "A Fault Manager component could not load due to an erroroneous configuration file." 94 msgid "FMD-8000-3F.response" 95 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 96 msgid "FMD-8000-3F.impact" 97 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 98 msgid "FMD-8000-3F.action" 99 msgstr "Load the module after repairing its configuration." 100 # 101 # code: FMD-8000-4M 102 # keys: list.repaired 103 # 104 msgid "FMD-8000-4M.type" 105 msgstr "Repair" 106 msgid "FMD-8000-4M.severity" 107 msgstr "Minor" 108 msgid "FMD-8000-4M.description" 109 msgstr "All faults associated with an event id have been addressed." 110 msgid "FMD-8000-4M.response" 111 msgstr "Some system components offlined because of the original fault may have been brought back online." 112 msgid "FMD-8000-4M.impact" 113 msgstr "Performance degradation of the system due to the original fault may have been recovered." 114 msgid "FMD-8000-4M.action" 115 msgstr "None." 116 # 117 # code: FMD-8000-58 118 # keys: list.updated 119 # 120 msgid "FMD-8000-58.type" 121 msgstr "Update" 122 msgid "FMD-8000-58.severity" 123 msgstr "Minor" 124 msgid "FMD-8000-58.description" 125 msgstr "Some faults associated with an event id have been addressed." 126 msgid "FMD-8000-58.response" 127 msgstr "Some system components offlined because of the original fault may have been brought back online." 128 msgid "FMD-8000-58.impact" 129 msgstr "Performance degradation of the system due to the original fault may have been recovered." 130 msgid "FMD-8000-58.action" 131 msgstr "Identify the repaired components, and any suspects that still need to be repaired." 132 # 133 # code: FMD-8000-6U 134 # keys: list.resolved 135 # 136 msgid "FMD-8000-6U.type" 137 msgstr "Resolved" 138 msgid "FMD-8000-6U.severity" 139 msgstr "Minor" 140 msgid "FMD-8000-6U.description" 141 msgstr "All faults associated with an event id have been addressed." 142 msgid "FMD-8000-6U.response" 143 msgstr "All system components offlined because of the original fault have been brought back online." 144 msgid "FMD-8000-6U.impact" 145 msgstr "Performance degradation of the system due to the original fault has been recovered." 146 msgid "FMD-8000-6U.action" 147 msgstr "None."