1 # 2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 3 # 4 # CDDL HEADER START 5 # 6 # The contents of this file are subject to the terms of the 7 # Common Development and Distribution License (the "License"). 8 # You may not use this file except in compliance with the License. 9 # 10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 11 # or http://www.opensolaris.org/os/licensing. 12 # See the License for the specific language governing permissions 13 # and limitations under the License. 14 # 15 # When distributing Covered Code, include this CDDL HEADER in each 16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 17 # If applicable, add the following below this CDDL HEADER, with the 18 # fields enclosed by brackets "[]" replaced with your own identifying 19 # information: Portions Copyright [yyyy] [name of copyright owner] 20 # 21 # CDDL HEADER END 22 # 23 24 # DO NOT EDIT -- this file is generated by the Event Registry. 25 # 26 # 27 # General-purpose messages 28 # 29 msgid "syslog-msgs-message-template" 30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 31 # 32 # Fault-related messages 33 # 34 # 35 # 36 # code: FMD-8000-0W 37 # keys: defect.sunos.fmd.nosub 38 # 39 msgid "FMD-8000-0W.type" 40 msgstr "Defect" 41 msgid "FMD-8000-0W.severity" 42 msgstr "Minor" 43 msgid "FMD-8000-0W.description" 44 msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." 45 msgid "FMD-8000-0W.response" 46 msgstr "Error reports from the component will be logged for examination by your illumos distribution team." 47 msgid "FMD-8000-0W.impact" 48 msgstr "Automated diagnosis and response for these events will not occur." 49 msgid "FMD-8000-0W.action" 50 msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support." 51 # 52 # code: FMD-8000-11 53 # keys: defect.sunos.fmd.nodiagcode 54 # 55 msgid "FMD-8000-11.type" 56 msgstr "Defect" 57 msgid "FMD-8000-11.severity" 58 msgstr "Minor" 59 msgid "FMD-8000-11.description" 60 msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." 61 msgid "FMD-8000-11.response" 62 msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team." 63 msgid "FMD-8000-11.impact" 64 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 65 msgid "FMD-8000-11.action" 66 msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Ensure that fault management software is installed properly." 67 # 68 # code: FMD-8000-2K 69 # keys: defect.sunos.fmd.module 70 # 71 msgid "FMD-8000-2K.type" 72 msgstr "Defect" 73 msgid "FMD-8000-2K.severity" 74 msgstr "Minor" 75 msgid "FMD-8000-2K.description" 76 msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." 77 msgid "FMD-8000-2K.response" 78 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 79 msgid "FMD-8000-2K.impact" 80 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 81 msgid "FMD-8000-2K.action" 82 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." 83 # 84 # code: FMD-8000-3F 85 # keys: defect.sunos.fmd.config 86 # 87 msgid "FMD-8000-3F.type" 88 msgstr "Defect" 89 msgid "FMD-8000-3F.severity" 90 msgstr "Minor" 91 msgid "FMD-8000-3F.description" 92 msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." 93 msgid "FMD-8000-3F.response" 94 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 95 msgid "FMD-8000-3F.impact" 96 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 97 msgid "FMD-8000-3F.action" 98 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." 99 # 100 # code: FMD-8000-4M 101 # keys: list.repaired 102 # 103 msgid "FMD-8000-4M.type" 104 msgstr "Repair" 105 msgid "FMD-8000-4M.severity" 106 msgstr "Minor" 107 msgid "FMD-8000-4M.description" 108 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 109 msgid "FMD-8000-4M.response" 110 msgstr "Some system components offlined because of the original fault may have been brought back online." 111 msgid "FMD-8000-4M.impact" 112 msgstr "Performance degradation of the system due to the original fault may have been recovered." 113 msgid "FMD-8000-4M.action" 114 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." 115 # 116 # code: FMD-8000-58 117 # keys: list.updated 118 # 119 msgid "FMD-8000-58.type" 120 msgstr "Update" 121 msgid "FMD-8000-58.severity" 122 msgstr "Minor" 123 msgid "FMD-8000-58.description" 124 msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information." 125 msgid "FMD-8000-58.response" 126 msgstr "Some system components offlined because of the original fault may have been brought back online." 127 msgid "FMD-8000-58.impact" 128 msgstr "Performance degradation of the system due to the original fault may have been recovered." 129 msgid "FMD-8000-58.action" 130 msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired." 131 # 132 # code: FMD-8000-6U 133 # keys: list.resolved 134 # 135 msgid "FMD-8000-6U.type" 136 msgstr "Resolved" 137 msgid "FMD-8000-6U.severity" 138 msgstr "Minor" 139 msgid "FMD-8000-6U.description" 140 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 141 msgid "FMD-8000-6U.response" 142 msgstr "All system components offlined because of the original fault have been brought back online." 143 msgid "FMD-8000-6U.impact" 144 msgstr "Performance degradation of the system due to the original fault has been recovered." 145 msgid "FMD-8000-6U.action" 146 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."