1 #
2 # Copyright 2008 Sun Microsystems, Inc. All rights reserved.
3 # Use is subject to license terms.
4 # Copyright 2016 Nexenta Systems, Inc. All rights reserved.
5 #
6 # CDDL HEADER START
7 #
8 # The contents of this file are subject to the terms of the
9 # Common Development and Distribution License (the "License").
10 # You may not use this file except in compliance with the License.
11 #
12 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
13 # or http://www.opensolaris.org/os/licensing.
14 # See the License for the specific language governing permissions
15 # and limitations under the License.
16 #
17 # When distributing Covered Code, include this CDDL HEADER in each
18 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
19 # If applicable, add the following below this CDDL HEADER, with the
20 # fields enclosed by brackets "[]" replaced with your own identifying
21 # information: Portions Copyright [yyyy] [name of copyright owner]
22 #
23 # CDDL HEADER END
24 #
25 #
26 # DO NOT EDIT -- this file is generated by the Event Registry.
27 #
28 #
29 # code: DISK-8000-0X
30 # keys: fault.io.disk.predictive-failure
31 #
32 msgid "DISK-8000-0X.type"
33 msgstr "Fault"
34 msgid "DISK-8000-0X.severity"
35 msgstr "Major"
36 msgid "DISK-8000-0X.description"
37 msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information."
38 msgid "DISK-8000-0X.response"
39 msgstr "None.\n"
40 msgid "DISK-8000-0X.impact"
41 msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
42 msgid "DISK-8000-0X.action"
43 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
44 #
45 # code: DISK-8000-12
46 # keys: fault.io.disk.over-temperature
47 #
48 msgid "DISK-8000-12.type"
49 msgstr "Fault"
50 msgid "DISK-8000-12.severity"
51 msgstr "Major"
52 msgid "DISK-8000-12.description"
53 msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information."
54 msgid "DISK-8000-12.response"
55 msgstr "None.\n"
56 msgid "DISK-8000-12.impact"
57 msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
58 msgid "DISK-8000-12.action"
59 msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
60 #
61 # code: DISK-8000-2J
62 # keys: fault.io.disk.self-test-failure
63 #
64 msgid "DISK-8000-2J.type"
65 msgstr "Fault"
66 msgid "DISK-8000-2J.severity"
67 msgstr "Critical"
68 msgid "DISK-8000-2J.description"
69 msgstr "One or more disk self tests failed.\n Refer to %s for more information."
70 msgid "DISK-8000-2J.response"
71 msgstr "None.\n"
72 msgid "DISK-8000-2J.impact"
73 msgstr "The disk has failed.\n"
74 msgid "DISK-8000-2J.action"
75 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
76 #
77 # code: DISK-8000-3E
78 # keys: fault.io.scsi.cmd.disk.dev.rqs.derr
79 #
80 msgid "DISK-8000-3E.type"
81 msgstr "Fault"
82 msgid "DISK-8000-3E.severity"
83 msgstr "Critical"
84 msgid "DISK-8000-3E.description"
85 msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information."
86 msgid "DISK-8000-3E.response"
87 msgstr "The device may be offlined or degraded.\n"
88 msgid "DISK-8000-3E.impact"
89 msgstr "The device has failed. The service may have been lost or degraded.\n"
90 msgid "DISK-8000-3E.action"
91 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
92 #
93 # code: DISK-8000-4Q
94 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr
95 #
96 msgid "DISK-8000-4Q.type"
97 msgstr "Fault"
98 msgid "DISK-8000-4Q.severity"
99 msgstr "Critical"
100 msgid "DISK-8000-4Q.description"
101 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information."
102 msgid "DISK-8000-4Q.response"
103 msgstr "The device may be offlined or degraded.\n"
104 msgid "DISK-8000-4Q.impact"
105 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
106 msgid "DISK-8000-4Q.action"
107 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
108 #
109 # code: DISK-8000-8D
110 # keys: fault.io.disk.ssm-wearout
111 #
112 msgid "DISK-8000-8D.type"
113 msgstr "Fault"
114 msgid "DISK-8000-8D.severity"
115 msgstr "Major"
116 msgid "DISK-8000-8D.description"
117 msgstr "A solid state media device is nearing end of life as projected by the manufacturer."
118 msgid "DISK-8000-8D.response"
119 msgstr "None."
120 msgid "DISK-8000-8D.impact"
121 msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss."
122 msgid "DISK-8000-8D.action"
123 msgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive."
|
1 #
2 # CDDL HEADER START
3 #
4 # The contents of this file are subject to the terms of the
5 # Common Development and Distribution License (the "License").
6 # You may not use this file except in compliance with the License.
7 #
8 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
9 # or http://www.opensolaris.org/os/licensing.
10 # See the License for the specific language governing permissions
11 # and limitations under the License.
12 #
13 # When distributing Covered Code, include this CDDL HEADER in each
14 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
15 # If applicable, add the following below this CDDL HEADER, with the
16 # fields enclosed by brackets "[]" replaced with your own identifying
17 # information: Portions Copyright [yyyy] [name of copyright owner]
18 #
19 # CDDL HEADER END
20 #
21
22 #
23 # Copyright 2008 Sun Microsystems, Inc. All rights reserved.
24 # Copyright 2017 Nexenta Systems, Inc.
25 #
26
27 #
28 #
29 # code: DISK-8000-0X
30 # keys: fault.io.disk.predictive-failure
31 #
32 msgid "DISK-8000-0X.type"
33 msgstr "Fault"
34 msgid "DISK-8000-0X.severity"
35 msgstr "Major"
36 msgid "DISK-8000-0X.description"
37 msgstr "SMART health-monitoring firmware reported that a disk failure is imminent."
38 msgid "DISK-8000-0X.response"
39 msgstr "None."
40 msgid "DISK-8000-0X.impact"
41 msgstr "It is likely that the continued operation of this disk will result in data loss."
42 msgid "DISK-8000-0X.action"
43 msgstr "Schedule a repair procedure to replace the affected disk."
44 #
45 # code: DISK-8000-12
46 # keys: fault.io.disk.over-temperature
47 #
48 msgid "DISK-8000-12.type"
49 msgstr "Fault"
50 msgid "DISK-8000-12.severity"
51 msgstr "Major"
52 msgid "DISK-8000-12.description"
53 msgstr "The disk temperature exceeded the limits established by its manufacturer."
54 msgid "DISK-8000-12.response"
55 msgstr "None."
56 msgid "DISK-8000-12.impact"
57 msgstr "Performance degradation is likely and continued disk operation beyond the temperature threshold can result in disk damage and potential data loss."
58 msgid "DISK-8000-12.action"
59 msgstr "Ensure that the system is properly cooled, that all fans are functional, and that there are no obstructions of airflow to the affected disk."
60 #
61 # code: DISK-8000-2J
62 # keys: fault.io.disk.self-test-failure
63 #
64 msgid "DISK-8000-2J.type"
65 msgstr "Fault"
66 msgid "DISK-8000-2J.severity"
67 msgstr "Critical"
68 msgid "DISK-8000-2J.description"
69 msgstr "One or more disk self tests failed."
70 msgid "DISK-8000-2J.response"
71 msgstr "None."
72 msgid "DISK-8000-2J.impact"
73 msgstr "The disk has failed."
74 msgid "DISK-8000-2J.action"
75 msgstr "Schedule a repair procedure to replace the affected disk."
76 #
77 # code: DISK-8000-3E
78 # keys: fault.io.scsi.cmd.disk.dev.rqs.derr
79 #
80 msgid "DISK-8000-3E.type"
81 msgstr "Fault"
82 msgid "DISK-8000-3E.severity"
83 msgstr "Critical"
84 msgid "DISK-8000-3E.description"
85 msgstr "A non-recoverable hardware failure was detected by the device while performing a command."
86 msgid "DISK-8000-3E.response"
87 msgstr "The device may be offlined or degraded."
88 msgid "DISK-8000-3E.impact"
89 msgstr "The device has failed. The service may have been lost or degraded."
90 msgid "DISK-8000-3E.action"
91 msgstr "Schedule a repair procedure to replace the affected device."
92 #
93 # code: DISK-8000-4Q
94 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr
95 #
96 msgid "DISK-8000-4Q.type"
97 msgstr "Fault"
98 msgid "DISK-8000-4Q.severity"
99 msgstr "Critical"
100 msgid "DISK-8000-4Q.description"
101 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data."
102 msgid "DISK-8000-4Q.response"
103 msgstr "The device may be offlined or degraded."
104 msgid "DISK-8000-4Q.impact"
105 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation."
106 msgid "DISK-8000-4Q.action"
107 msgstr "Schedule a repair procedure to replace the affected device."
108 #
109 # code: DISK-8000-5C
110 # keys: fault.io.disk.attach-failure
111 #
112 msgid "DISK-8000-5C.type"
113 msgstr "Fault"
114 msgid "DISK-8000-5C.severity"
115 msgstr "Critical"
116 msgid "DISK-8000-5C.description"
117 msgstr "A disk device failed to attach. Either the device is broken, or it is just taking unusually long to respond. The latter is often the case with battery-backed RAM disk devices when the battery needs to be charged."
118 msgid "DISK-8000-5C.response"
119 msgstr "None."
120 msgid "DISK-8000-5C.impact"
121 msgstr "The device will not be usable."
122 msgid "DISK-8000-5C.action"
123 msgstr "Schedule a repair procedure to replace the affected device. If this is a battery-backed RAM disk or similar device, you can also try to reactivate the device once the battery is charged."
124 #
125 # code: DISK-8000-6R
126 # keys: fault.io.disk.device-errors-exceeded
127 #
128 msgid "DISK-8000-6R.type"
129 msgstr "Fault"
130 msgid "DISK-8000-6R.severity"
131 msgstr "Critical"
132 msgid "DISK-8000-6R.description"
133 msgstr "A disk device has experienced too many device errors."
134 msgid "DISK-8000-6R.response"
135 msgstr "An attempt has been made to take the disk out of service. If the device is part of an active ZFS pool, the device still may be in service."
136 msgid "DISK-8000-6R.impact"
137 msgstr "Optionally degraded redundancy and performance."
138 msgid "DISK-8000-6R.action"
139 msgstr "Determine the cause of the fault and schedule a repair service."
140 #
141 # code: DISK-8000-74
142 # keys: fault.io.disk.slow-io
143 #
144 msgid "DISK-8000-74.type"
145 msgstr "Fault"
146 msgid "DISK-8000-74.severity"
147 msgstr "Critical"
148 msgid "DISK-8000-74.description"
149 msgstr "A disk device is experiencing too many slows IOs above its configured threshold."
150 msgid "DISK-8000-74.response"
151 msgstr "Depending on configuration the device may have been retired."
152 msgid "DISK-8000-74.impact"
153 msgstr "Optionally degraded performance and redundancy."
154 msgid "DISK-8000-74.action"
155 msgstr "Determine the cause of the fault and schedule a repair service."
156 #
157 # code: DISK-8000-8D
158 # keys: fault.io.disk.ssm-wearout
159 #
160 msgid "DISK-8000-8D.type"
161 msgstr "Fault"
162 msgid "DISK-8000-8D.severity"
163 msgstr "Major"
164 msgid "DISK-8000-8D.description"
165 msgstr "A solid state media device is nearing end of life as projected by the manufacturer."
166 msgid "DISK-8000-8D.response"
167 msgstr "None."
168 msgid "DISK-8000-8D.impact"
169 msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss."
170 msgid "DISK-8000-8D.action"
171 msgstr "Schedule a repair procedure to replace the affected drive."
|